Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 642-653, 2006.
Article in Korean | WPRIM | ID: wpr-27829

ABSTRACT

PURPOSE: The purpose of this study was to investigate the effect of the output energy(voltage) of laser welding on the strength and properties of joint of cast titanium(CP Gr II) and titanium alloy(Ti-6Al-4V). MATERIAL AND METHOD: Cast titanium and its alloy rods(ISO6871) were prepared and perpendicularly cut at the center of the rod. After the cut halves were fixed in a jig, and the joints welded with a laser-welding machine at several levels of output voltage of 200V.280V. Uncut specimens served as the non-welded control specimens. The pulse duration and pulse spot size employed in this study were 10ms and 1.0mm respectively. Tensile testing was conducted at a crosshead speed of 0.5mm/min. The ultimate tensile strength(MPa) was recorded, and the data(n=6) were statistically analyzed by one-way analysis of variance(ANOVA) and Scheffe's test at alpha=0.05. The fracture surface of specimens investigated by scanning electron microscope(SEM). Vickers microhardness was measured under 500g load of 15seconds with the optimal condition of output voltage 280V. RESULTS: The results of this study were obtained as follows, 1. When the pulse duration and spot size were fixed at 10ms and 1.0mm respectively, increasing the output energy(voltage) increased UTS values and penetration depth of laser welded to titanium and titanium alloy. 2. For the commercial titanium grade II, ultimate tensile strength(665.3MPa) of the specimens laser-welded at voltage of 280V were not statistically(p>0.05) different from the non-welded control specimens(680.2MPa). 3. For the titanium alloy(Ti-6Al-4V), ultimate tensile strength(988.3MPa) of the specimens laser-welded at voltage of 280V were statistically(p<0.05) different from the nonwelded control specimens(665.0MPa). 4. The commercial titanium grade II and titanium alloy(Ti-6Al-4V) were Vickers microhardness values were increased in the fusion zone and there were no significant differences in base metal, heat-affected zone.


Subject(s)
Alloys , Joints , Titanium , Welding
2.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 170-172, 2005.
Article in Chinese | WPRIM | ID: wpr-977996

ABSTRACT

@# Objective Due to the problem of individual matching, exclusivity and loose with pure mechanical fixation for artificial hemi-knee joints made by traditional method, a new manufacturing process based on rapid prototyping technique and custom-made concept is presented.MethodsRapid prototyping was processed to rapidly and accurately shape the prototype of an artificial implant almost with the same shape as the hemi-knee joint of the patient, and the process based on Titanium alloy centrifugal casting technology and biomaterial sintering molding technology was used to fabricate the artificial hemi-knee joint and bioactive proximal tibia artificial bone, respectively.Results and ConclusionThe custom-made knee joint prosthesis has been fabricated and put into clinical use successfully. In comparison with the traditional implants, this system can realize the well matching movement between the artificial hemi-knee joint and its opposite. Meanwhile,the design of functional holes and tibial nails realizes the combination of biological fixation with mechanical fixation for the artificial implant,and the use of bioactive artificial bone promotes bone growth and minimizes the exclusive reaction.

SELECTION OF CITATIONS
SEARCH DETAIL