Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Hip & Pelvis ; : 95-101, 2013.
Article in Korean | WPRIM | ID: wpr-67385

ABSTRACT

PURPOSE: The purpose of this study was to analyze the results for clinical outcome and radiologic assessment of ceramic on ceramic cementless total hip arthroplasty using a 36 mm diameter femoral head. MATERIALS AND METHODS: This study included a group of 40 patients of 43 cases who underwent ceramic on ceramic cementless total hip arthroplasty using a 36 mm diameter femoral head. The age range of this group was 28 to 82(mean 56); we monitored them over a period of 5.3 years(3-7.5 years). This clinical evaluation process included monitoring the degree of pain, range of motion, and the Harris hip score after three years since the surgery was performed. Radiographic evaluation and complication were confirmed as well. RESULTS: The preoperative Harris hip score increased from 43.4(21-57) to 88.1(81-95) after the surgery. The average motion range of hip was 113degrees flexion, 30degrees abduction, 24degrees adduction, 36degrees external rotation, and 12degrees internal rotation. Subjective pain was zero or minimal in all cases. Among the complications, dislocation occurred in only one case by a fall from a height and was reduced by closed reduction. There was no occurrence of ceramic fracture, even though infection occurred in one hip. CONCLUSION: The clinical outcome and radiologic assessment of the ceramic on ceramic cementless total hip arthroplasty using a 36 mm diameter femoral head showed a satisfactory result at three-year follow-up. Longer-term follow up is needed for further assessment.


Subject(s)
Humans , Arthroplasty , Ceramics , Joint Dislocations , Follow-Up Studies , Head , Hip , Range of Motion, Articular
2.
Hip & Pelvis ; : 194-199, 2012.
Article in Korean | WPRIM | ID: wpr-221114

ABSTRACT

PURPOSE: The purpose of this study is to report clinical and radiographic results over a period of two 2 years after cementless total hip arthroplasty (THA) with fourth generation ceramic-on-ceramic articulation. MATERIALS AND METHODS: We studied 22 patients, 23 cases which were followed up for two years among 25 patients, 26 patients who underwent cementless THA with the fourth generation ceramic between April 2009 and December 2009. The average age of the patients was 55.9 years old(22 to 72 years old), and the average follow-up duration was 28 months(24 to 32 months). A clinical evaluation was performed using the Harris hip score (HHS), and radiologic evaluation was based on acetabular cups and osteolysis of the femoral stems, instability, distance, angle, and so on. RESULTS: HHS showed an increase, from 54 for before-surgical treatment, to 91 at the last follow-up. Inguinal pain was observed in one case, and femoral pain was observed in two cases. Stable fixation was achieved in all cases, and no instability, osteolysis, or movement of acetabular cups and femoral stems was observed. CONCLUSION: Clinical and radiological short-term results for use ofthe fourth generation ceramic-on-ceramic cementless THA have favorable so far. Further follow-up study should be performed for evaluation of the long-term results.


Subject(s)
Humans , Arthroplasty , Ceramics , Follow-Up Studies , Hip , Osteolysis , Tacrine
3.
Journal of the Korean Hip Society ; : 268-274, 2011.
Article in Korean | WPRIM | ID: wpr-727060

ABSTRACT

PURPOSE: We believe that cemented femoral stems will relieve the stiffness of ceramic-based bearings, resulting in reduced complication of ceramic-on-ceramic bearing total hip arthroplasty (THA). The purpose of this study was to evaluate the midterm effect of ceramic-on-ceramic bearing THA using cemented femoral stems. MATERIALS AND METHODS: We studied 32cases (30 patients) of THA using ceramic-on-ceramic bearing cemented femoral stems and 33 cases (31 patients) of THA using ceramic-on-ceramic bearing cementless femoral stems. All total hip arthroplasties were performed between January 2004 and December 2005 and were followed up for more than 5 years. The clinical results and radiographic results were evaluated. RESULTS: The mean HHS improved from points pre-operatively to points at the last follow-up in both the cemented and cementless stem groups (P<0.05). The mean WOMAC score also improved from points pre-operatively to points at the last follow-up in both the cemented and cementless stem groups (P<0.05). But no statistically significant difference was noted between the cemented and cementless stem groups in HHS and WOMAC scores (P=0.304, P=0.769). There were 3 patients with a sense of discomfort on ambulation and 5 patients with thigh pain in the cementless stem group and no cases in the cemented stem group. There was no instance of acetabular loosening in either group. Subsidenc of the cemented femoral stem was less than 1mm in 30 cases and less than 2 mm in 2 cases. All cementless femoral stems acquired firm bony union. CONCLUSION: Midterm results showed no statistical links between ceramicon-ceramic-bearing THA using cemented femoral stems or cementless femoral stems.


Subject(s)
Humans , Arthroplasty , Follow-Up Studies , Hip , Tacrine , Thigh , Ursidae , Walking
4.
Journal of the Korean Hip Society ; : 183-188, 2010.
Article in Korean | WPRIM | ID: wpr-727082

ABSTRACT

PURPOSE: We wanted to evaluate the clinical and radiological results of total hip arthroplasty using a ceramic-on-ceramic articulation. MATERIALS AND METHODS: From March 2004 to February 2006, total hip arthroplasty was performed in 21 patients and 31 hips. The mean follow up period was 56 months (range: 48~72 months). The causes for the AVN were alcohol in 12 cases, idiopathic in 10 cases, steroid in 6 cases and post-traumatic in 3 cases. The clinical results were evaluated using the Harris hip score and according to the pain on the inguinal area or thigh. The radiographic evaluation was performed to determine the level of osteolysis and instability around the acetabular cup and femoral stem, the position of the femoral stem and the wear of the articular surface. RESULTS: At the most recent follow-up, the mean Harris hip score was 93 points with no inguinal or thigh pain. The complications included one case of peroneal nerve palsy, one case of ceramic head fracture, two cases of noise in the joint, two cases of posterior dislocation and two patients died because of complication related to liver cirrhosis. Radiologically, bone ingrowth was noted in all the cases with no migration of the acetabular component and femoral stem, changing of the position or osteolysis. CONCLUSION: Total hip arthroplasty with ceramic on ceramic articulation shows satisfactory results at an average of 56 months follow up. There was bone ingrowth in all cases except for one ceramic head fracture. Further follow-up study should be performed to evaluate the long-term results.


Subject(s)
Humans , Aluminum Oxide , Arthroplasty , Ceramics , Joint Dislocations , Follow-Up Studies , Head , Hip , Joints , Liver Cirrhosis , Noise , Osteolysis , Paralysis , Peroneal Nerve , Thigh
5.
The Journal of the Korean Orthopaedic Association ; : 342-346, 2010.
Article in Korean | WPRIM | ID: wpr-655704

ABSTRACT

PURPOSE: The authors evaluated the clinical and radiological results of ceramic on ceramic articulation cementless total hip arthroplasty using a large diameter head. MATERIALS AND METHODS: Seventy-two hips were followed for more than 2 years after ceramic on ceramic articulation cementless total hip arthroplasty using a 36 mm diameter head. The mean patient age was 62 years (range: 50-85), and the mean follow-up period was 35.3 months (range: 25-53). The Harris hip score, the postoperative inguinal pain and the thigh pain were analyzed clinically. The radiological results were assessed using various radiological indices. RESULTS: The mean Harris hip score improved from preoperative 57.5 points to postoperative 94.8 points. The postoperative mean flexion of hip was 109degrees (range: 100degrees-125degrees), external rotation was 42degrees (range: 35degrees-49degrees) and abduction was 35degrees (range: 30degrees-45degrees). There was one case of inguinal pain. Radiologically, all the stems demonstrated stable fixation without progressive subsidence of the stem or significant change in the cup obliquity. A radiolucent line was observed around the stem in 4 cases (5.6%) and around the cup in 2 cases (2.8%). Endosteal new bone formation was observed around the stem in 28 cases (38.9%) and around the cup in 26 cases (36.1%). There was no osteolysis around the stem or the cup. CONCLUSION: The short-term results of ceramic on ceramic cementless total hip arthroplasty using a large diameter head demonstrated satisfactory results.


Subject(s)
Humans , Arthroplasty , Ceramics , Follow-Up Studies , Head , Hip , Osteogenesis , Osteolysis , Thigh
6.
The Journal of the Korean Orthopaedic Association ; : 520-525, 2009.
Article in Korean | WPRIM | ID: wpr-656459

ABSTRACT

PURPOSE: To evaluate the 8-year follow up results of the clinical and radiographic of the cementless total hip arthroplasty using the Osteonics(R) system with ceramic-on-ceramic articulation on a retrospective basis. MATERIALS AND METHODS: Between March 1999 and February 2000, 31 primary total hip arthroplasties were performed in 27 patients using the cementless Osteonics(R) system. The mean follow-up period was 101 months (96-107 months). The mean age at surgery was 56.5 years of age (28-62 years). Preoperative diagnoses were the following in the 27 patients: 5 cases of primary osteoarthritis, 15 cases of avascular necrosis, and 7 cases of secondary osteoarthritis. The clinical results were evaluated using the Harris hip score and radiographic evaluation was done in terms of the fixation of components, the prevalence of osteolysis, and wear of ceramics. RESULTS: The mean preoperative Harris hip score at was the most recent follow-up was 91. Complications were calcar fracture in 8 cases, posterior dislocation in 2 cases, continuous thigh pain in 2 cases, squeaking sound in 3 cases, and limping gait lasting at least 1-year post operation in 6 cases. All cases had fixation by bony ingrowth was and there was no migration of acetabular cups nor osteolysis. There was no loosening of the femoral stem. It was not possible to measure ceramic wear and there were no ceramic fractures. CONCLUSION: At the 8-year follow-up, results of the cementless total hip arthroplasty using the Osteonics(R) system with ceramic-on-ceramic articulation demonstrated favorable results of osseointegration of the components and unmeasurable ceramic wear. However, longer-term-follow up was necessary. We believe that further study is required to determine the high incidence of squeaking.


Subject(s)
Humans , Arthroplasty , Ceramics , Joint Dislocations , Follow-Up Studies , Gait , Hip , Incidence , Necrosis , Osseointegration , Osteoarthritis , Osteolysis , Prevalence , Retrospective Studies , Thigh
7.
Journal of the Korean Hip Society ; : 169-175, 2008.
Article in Korean | WPRIM | ID: wpr-727109

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the results of ceramic-on-ceramic bearing primary total hip arthroplasty (THA) using cemented femoral stems and cementless femoral stems. MATERIALS AND METHODS: We studied 59 cases (52 patients) of THAs using ceramic-on-ceramic bearing cemented femoral stems and 64 cases (58 patients) of THAs using ceramic-on-ceramic bearing cementless femoral stems. All THAs were performed between January 2004 and February 2005 and were followed up for more than 3 years. The clinical results were evaluated using the Harris hip score (HHS), WOMAC score, sense of discomfort, and thigh pain. Radiographic results were assessed with serial radiographs. RESULTS: The mean HHS improved from 62.7 points preoperatively to 92.4 points at the last follow-up in the cemented stem group and improved from 61.5 points to 91.8 points in the cementless stem group (p>0.05). And mean WOMAC score improved from 37.9 points to 7.0 points in the cemented stem group and from 38.5 points to 12 points in the cementless stem group (p<0.05). There were 5 patients with a sense of discomfort and 9 patients with thigh pain in the cementless stem group and no cases in the cemented stem group. There were no instances of acetabular loosening in either group. Subsidence of the cemented femoral stem was less than 1 mm in 57 cases and less than 2 mm in 2 cases. All cementless femoral stems acquired firm bony union. CONCLUSION: Ceramic-on-ceramic bearing THA using a cemented stem showed clinical results superior to those achieved using a cementless stem. Cemented THA is thought to be good for complementing the problems caused by the hardness of ceramic-on-ceramic bearings.


Subject(s)
Humans , Aldosterone , Arthroplasty , Ceramics , Complement System Proteins , Follow-Up Studies , Hardness , Hip , Tacrine , Thigh , Ursidae
8.
Journal of the Korean Hip Society ; : 9-15, 2007.
Article in Korean | WPRIM | ID: wpr-727150

ABSTRACT

PURPOSE: To prospectively evaluate the 3 years follow up clinical and radiographic results of uncemented total hip arthroplasty using the Summit(R) system with ceramic-on-ceramic articulation. MATERIALS AND METHODS: From January 2001 to December 2001, thirty-one primary total hip arthroplasties were performed on thirty-one patients using the Summit(R) system. The mean follow-up period was 3.3 years. The preoperative diagnoses were degenerative osteoarthritis in 18 cases, avascular necrosis in 10 cases, and a femoral neck fracture in 3 cases. The mean age at surgery was 67.4 years. The clinical results were evaluated using the Harris hip score. The radiographic evaluation was performed to determine the stability of the components, the prevalence of osteolysis and the amount of wear. RESULTS: The mean Harris hip score improved from 64.7 points preoperatively to 90.4 points at the most recent follow-up. The complications included two cases of dislocation, three cases of limping gait lasting for 1 year after surgery. Fixation by bone ingrowth was noted in all cases and there was no case of migration of the acetabular cup and osteolysis. There was no case in the varus position, sinking down, or a loosening of the femoral stem. On the final observation after surgery, the range of hip joint motion showed flexion of 120.7degreeson average (110degrees~150degrees), extension of 5degrees(0degrees~10degrees), internal rotation of 20.3degrees(15degrees~25degrees), external rotation of 33.7degrees(20degrees~40degrees), abduction of 29.4degrees(20degrees~40degrees), and adduction of 19.5degrees(15degrees~25degrees). CONCLUSION: Uncemented total hip arthroplasty using the Summit(R) system with ceramic-on-ceramic articulation showed excellent clinical and radiographic results in the range of motion and function.


Subject(s)
Humans , Acetabulum , Arthroplasty , Arthroplasty, Replacement, Hip , Diagnosis , Joint Dislocations , Femoral Neck Fractures , Follow-Up Studies , Gait , Hip , Hip Joint , Necrosis , Osteoarthritis , Osteolysis , Prevalence , Prospective Studies , Range of Motion, Articular
9.
Journal of the Korean Hip Society ; : 16-20, 2007.
Article in Korean | WPRIM | ID: wpr-727149

ABSTRACT

PURPOSE: This study evaluated the short-term results of ceramic articulation total hip arthroplasty in cementless total hip arthroplasty. MATERIALS AND METHODS: 142 hips were followed-up for more than 2 years after cementless total hip arthroplasty using ceramic-on-ceramic articulation. The mean age and follow-up period was 58.3 years and 3.0 years, respectively. The Harris hip score and postoperative hip pain were analyzed clinically. The radiological results were assessed using various radiological indices. RESULTS: At the last follow-up, the Harris hip score improved from 58.1 points preoperatively to 93.2 points postoperatively. There were 4 cases (2.8%) of significant hip pain. Radiologically, all the stems demonstrated stable fixation. The inclination of the acetabular cup was changed significantly in 2 cases (1.4%), which were diagnosed as being loosened. A radiolucent line was observed around the stem in 9 cases (6.3%), and around the cup in 3 (2.1%). Endosteal new bone formation was observed around the stem in 50 cases (35%), and around the cup in 55 (38.5%). No osteolysis was observed around the stem and the cup. CONCLUSION: The short-term results of ceramic on ceramic articulation hip arthroplasty were excellent without osteolysis.


Subject(s)
Acetabulum , Arthroplasty , Arthroplasty, Replacement, Hip , Ceramics , Follow-Up Studies , Hip , Osteogenesis , Osteolysis
10.
The Journal of the Korean Orthopaedic Association ; : 421-427, 2006.
Article in Korean | WPRIM | ID: wpr-646535

ABSTRACT

PURPOSE: To evaluate the medium-term clinical and radiographic results of uncemented total hip arthroplasty with ceramic-on-ceramic articulation. MATERIALS AND METHODS: From February 1999 to August 2000, fifty-two primary total hip arthroplasties were performed on forty-two patients using a ceramic-on-ceramic bearing implant. The mean follow-up period was 5.4 years (range, 5-6.6 years) and the mean age at surgery was 43.2 years (range, 19-66 years). The clinical results were evaluated using the Harris hip score. The radiographic evaluations were carried out in terms of the stability of the components, the prevalence of osteolysis and wear. RESULTS: At the most recent follow-up, the mean preoperative Harris hip score improved from 63 points (range, 26-93 points) to 97 points (range, 82-100 points). The Harris hip score showed excellent results in 49 hips (94%) and good results in 3 hips (6%). Fixation by bone ingrowth was noted in all cases and there was no case with osteolysis or a deep infection. Ceramic wear was not detectable on the plain radiograph. Complications included one case of dislocation, one case of a fracture of the ceramic femoral head and one case of an intraoperative periprosthetic proximal femoral crack. CONCLUSION: Ceramic-on-ceramic articulation showed excellent clinical and radiographic results in terms of wear, osteolysis and loosening. A further follow-up study should be performed to evaluate the long-term clinical and radiographic results with special focus on the fracture of the ceramic material.


Subject(s)
Humans , Arthroplasty , Arthroplasty, Replacement, Hip , Ceramics , Joint Dislocations , Follow-Up Studies , Head , Hip , Osteolysis , Prevalence
11.
The Journal of the Korean Orthopaedic Association ; : 916-922, 2005.
Article in Korean | WPRIM | ID: wpr-651550

ABSTRACT

PURPOSE: The authors evaluated the clinical and radiological short-term results of ceramic on ceramic articulation of cementless total hip arthroplasty. MATERIALS AND METHODS: One hundred fourteen patients, with a total of 130 hips were followed for more than 2 years after cementless total hip arthroplasty using ceramic on ceramic articulation (Lima. SPH-C2). The mean age was 58 years, and the mean follow-up period was 3.0 years. The Harris hip score and postoperative hip pain were analyzed clinically. The radiological results were assessed using various radiological indices such as subsidence, cup inclination angle, radiolucent line, endosteal new bone formation and osteolysis. RESULTS: At last follow-up, the average Harris hip score improved from 57.5 points preoperatively to 93 points postoperatively. There were 4 cases (3.0%) of significant hip pain. Radiologically, all stems demonstrated stable fixation. The inclination of the acetabular cup was significantly changed in 4 cases (3%), and was diagnosed as loosened. A radiolucent line was observed around the stem in 5 cases (3.8%), and around the cup in 7 cases (5.4%). Endosteal new bone formation was observed around the stem in 47 cases (36.2%), and around the cup in 52 cases (40.0%). Osteolysis was not observed around the stem and the cup. CONCLUSION: With a minimum follow-up of 2 years, ceramic on ceramic articulation hip arthroplasty demonstrated excellent results on the stem side. However, 4 cases (3.0%) of cup loosening suggest that there is a fixation problem due to the design of the cup.


Subject(s)
Humans , Acetabulum , Arthroplasty , Arthroplasty, Replacement, Hip , Ceramics , Follow-Up Studies , Hip , Osteogenesis , Osteolysis
SELECTION OF CITATIONS
SEARCH DETAIL