Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Radiol. bras ; 46(1): 15-22, jan.-fev. 2013. ilus, tab
Article in English | LILACS | ID: lil-666106

ABSTRACT

OBJECTIVE: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. MATERIALS AND METHODS: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. RESULTS: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. CONCLUSION: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis.


OBJETIVO: Avaliar a completude das fissuras, resposta radiológica ao tratamento e análise quantitativa por TC (AQTC) em população de pacientes com enfisema grave submetidos ao implante de valvas endobrônquicas (VEB). MATERIAIS E MÉTODOS: Foram estudados exames de TC multidetectores de 29 pacientes, realizados com protocolo de baixo dose, cortes finos, sem contraste. Dois radiologistas revisaram, retrospectivamente, os exames em consenso. A completude das fissuras foi estimada em escala de 5% e a resposta radiológica (atelectasia/perda volumétrica do lobo alvo) foi avaliada. AQTC foi realizada nos exames pré e pós-tratamento utilizando programa completamente automático. RESULTADOS: Resposta radiológica positiva foi vista em 16/29 pacientes. Os 13 pacientes sem resposta à TC apresentavam fissuras incompletas e completude média das fissuras obliquas de 72,8%, contra 88,3% no outro grupo. Os resultados mais significativos da AQTC mostraram redução do volume pulmonar (VP) total (média de 542 ml), VP tratado (700 ml) e volume de enfisema (331,4 ml) no grupo com resposta positiva, que também apresentou melhora nos testes funcionais. CONCLUSÃO: O benefício das VEB é maior em pacientes com fissuras completas e que desenvolvem atelectasia lobar. Nos pacientes sem resposta radiológica encontramos maior prevalência de fissuras incompletas e grau de incompletude das fissuras. Nossa AQTC automática detectou as alterações pós-tratamento, principalmente considerado a análise do pulmão tratado.


Subject(s)
Humans , Male , Female , Behavior, Addictive , Bronchial Fistula , Multidetector Computed Tomography , Pulmonary Emphysema
2.
Ciênc. rural ; 40(1): 246-253, jan.-fev. 2010.
Article in Portuguese | LILACS | ID: lil-537354

ABSTRACT

A pressão intrapleural normalmente é menor que a pressão intrapulmonar. Consequentemente , os pulmões tendem ao colapso e se retraem, afastando-se da parede torácica. No início do século XX, Pasteur descreveu a atelectasia pulmonar, que ocorre com frequência durante a indução anestésica, persiste no período pós-operatório e pode contribuir de maneira significativa para a morbidade e o aumento nos gastos com medicamentos. Em medicina veterinária, no entanto, a atelectasia não é frequentemente diagnosticada, apesar de que isso não implica afirmar que tal afecção não ocorra, visto que existem relatos do desenvolvimento desse quadro em cães e em outras espécies. No contexto da anestesia geral, essa complicação pulmonar pode ser encontrada em animais que respiram 80 a 100 por cento de oxigênio. A partir dessas informações, torna-se necessário que o profissional da anestesiologia veterinária obtenha conhecimentos complementares sobre o tema. Com este trabalho, objetivou-se descrever alguns dos mecanismos da atelectasia e seus pontos relevantes, de modo a familiarizar os profissionais quanto aos pormenores dessa importante, e nem sempre bem compreendida, alteração fisiológica respiratória.


Pleural pressure is usually lower than pulmonary pressure. Therefore, the lungs tend to collapse and increase its distance from thoracic walls. At the beginning of 20th century, Pasteur described the pulmonary atelectasis, which develops during induction of anesthesia and persists to the postoperative period. It can contribute significantly to morbidity and to increase the medical expenses. In veterinary medicine, pulmonary atelectasis is not frequently diagnosed, which doesn't rule out the occurrence of this disease, since there are reports of atelectsasis in dogs. This pulmonary complication can be found in animals that breathe 80 percent to 100 percent oxygen in anesthetic procedures. Based on this information, the veterinary anesthesiologist is required to search for complementary knowledge regarding to pulmonary atelectasis. This study, therefore, aimed to describe some of the mechanisms involved in the development of atelectasis. It aimed also to familiarize the anesthesiologist to this not always well- understood physiological breathing change.

3.
Rev. bras. anestesiol ; 58(2): 112-123, mar.-abr. 2008. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-477730

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Manobras de recrutamento alveolar (MRA) utilizando pressões de 40 cmH2O nas vias aéreas são efetivas em reverter as atelectasias após revascularização cirúrgica do miocárdio (RM), contudo não existem estudos avaliando o impacto hemodinâmico dessa manobra em pacientes que evoluíram com choque cardiogênico. O objetivo foi testar a tolerância hemodinâmica à MRA em pacientes evoluindo com choque cardiogênico após RM. MÉTODO: Após admissão na UTI e estabilização hemodinâmica, foram estudados dez pacientes hipoxêmicos e em choque cardiogênico após RM. Os ajustes ventilatórios foram volume corrente de 8 mL.kg-1, PEEP 5 cmH2O, FR de 12 ipm e FiO2 de 0,6. Pressão contínua de 40 cmH2O foi aplicada nas vias aéreas por 40 segundos em três ciclos. Entre os ciclos, os pacientes foram ventilados por 30 segundos e após o último ciclo a PEEP foi ajustada em 10 cmH2O. Foram obtidas medidas hemodinâmicas após 1, 10, 30 e 60 minutos da MRA e colhidas amostras sangüíneas arteriais e venosas para mensuração de lactato e gases sangüíneos 10 e 60 minutos após. Dados analisados por meio de ANOVA e teste de Friedman. Valor de p fixado em 0,05. RESULTADOS: A MRA aumentou a relação PaO2/FiO2 de 87 para 129,5 após 10 minutos e 120 após 60 minutos (p < 0,05) e reduziu o shunt pulmonar de 30 por cento para 20 por cento (p < 0,05). Não foram detectadas alterações hemodinâmicas ou no transporte de oxigênio imediatamente ou em até 60 minutos após a MRA. CONCLUSÕES: Em pacientes que evoluíram com choque cardiogênico após RM e hipoxemia, a MRA melhorou a oxigenação e foi bem tolerada sob o ponto de vista hemodinâmico.


BACKGROUND AND OBJECTIVES: Alveolar recruitment maneuver (ARM) with pressures of 40 cmH2 O in the airways is effective in the reversal of atelectasis after myocardial revascularization (MR); however, there is a lack of studies evaluating the hemodynamic impact of this maneuver in patients who evolve with cardiogenic shock after MR. The objective of this study was to test the hemodynamic tolerance to ARM in patients who develop cardiogenic shock after MR. METHODS: Ten hypoxemic patients in cardiogenic shock after MR were evaluated after admission to the ICU and hemodynamic stabilization. Ventilatory adjustments included tidal volume of 8 mL.kg-1, PEEP 5 cmH2O, RR 12, and FiO2 0.6. Continuous pressure of 40 cmH2O was applied to the airways for 40 seconds in three cycles. Between cycles, patients were ventilated for 30 seconds, and after the last cycle, PEEP was set at 10 cmH2O. Hemodynamic measurements were obtained 1, 10, 30, and 60 minutes after ARM, and arterial and venous blood samples were drawn 10 and 60 minutes after the maneuver to determine lactate levels and blood gases. ANOVA and the Friedman test were used to analyze the data. A p of 0.05 was considered significant. RESULTS: Alveolar recruitment maneuver increased the ratio PaO2/FiO2 from 87 to 129.5 after 10 minutes and to 120 after 60 minutes (p < 0.05) and reduced pulmonary shunting from 30 percent to 20 percent (p < 0.05). Hemodynamic changes or changes in oxygen transport immediately after or up to 60 minutes after the maneuver were not detected. CONCLUSIONS: In patients who evolved to cardiogenic shock and hypoxemia after MR, ARM improved oxygenation and was well tolerated hemodynamically.


JUSTIFICATIVA Y OBJETIVOS: Maniobras de reclutamiento alveolar (MRA) utilizando presiones de 40 cmH2O en las vías aéreas son efectivas en revertir las atelectasias después de la revascularización quirúrgica del miocardio (RM), sin embargo, no existen estudios que evalúen el impacto hemodinámico de esta maniobra en pacientes que evolucionaron con choque cardiogénico. El objetivo fue probar la tolerancia hemodinámica a la MRA en pacientes que evolucionan con choque cardiogénico después de la RM. MÉTODO: Después de la entrada en la UCI y de la estabilización hemodinámica, se estudiaron 10 pacientes hipoxémicos y en choque cardiogénico después de RM. Los ajustes de ventilación fueron volumen corriente de 8 mL.kg-1, PEEP 5 cmH2O, FR de 12 ipm y FiO2 de 0,6. Presión continua de 40 cmH2O se aplicó en las vías aéreas por 40 segundos en tres ciclos. Entre los ciclos, los pacientes fueron ventilados por 30 segundos y después del último ciclo, la PEEP fue ajustada en 10 cmH2O. Fueron obtenidas medidas hemodinámicas después de 1, 10, 30 y 60 minutos de la MRA y recogidas muestras de sangre arteriales y venosas para la medida de lactato y de los gases sanguíneos 10 y 60 minutos después. Datos analizados a través de ANOVA y test de Friedman. Valor de p fijado en 0,05. RESULTADOS: La MRA aumentó la relación PaO2/FiO2 de 87 para 129,5 después de 10 minutos y 120 después de 60 minutos (p < 0,05) y redujo el shunt pulmonar de 30 por ciento para 20 por ciento (p < 0,05). No se detectaron alteraciones hemodinámicas o en el transporte de oxígeno inmediatamente o en hasta 60 minutos después de la MRA. CONCLUSIONES: En pacientes que evolucionaron con choque cardiogénico después de RM e hipoxemia, la MRA mejoró la oxigenación y fue bien tolerada hemodinámicamente.


Subject(s)
Aged , Humans , Hemodynamics , Myocardial Revascularization/adverse effects , Respiration, Artificial , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Shock, Cardiogenic/physiopathology , Time Factors
4.
Rev. bras. anestesiol ; 58(1): 73-83, jan.-fev. 2008.
Article in English, Portuguese | LILACS | ID: lil-473078

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: O colapso pulmonar intra-operatório é uma complicação de elevada incidência em pacientes submetidos à intervenção cirúrgica sob anestesia geral com relaxamento/paralisia da musculatura. Essa complicação está associada à piora das trocas gasosas no intra-operatório e, em alguns casos, necessidade de suporte respiratório prolongado no período pós-operatório. Os objetivos deste estudo foram revisar os aspectos fisiopatológicos da formação de atelectasias durante anestesia geral e as possíveis manobras terapêuticas para prevenir e tratar essa complicação. CONTEÚDO: Nesta revisão, os conceitos sobre a incidência de atelectasias intra-operatórias, os fatores relacionados com o seu desenvolvimento, tanto mecânicos quanto associados ao ajuste do respirador durante procedimento cirúrgico, os aspectos do diagnóstico e as estratégias de prevenção e tratamento foram abordados de maneira sistemática. CONCLUSÕES: A compreensão dos mecanismos relacionados com o desenvolvimento do colapso pulmonar durante o período intra-operatório, assim como o seu tratamento, pode contribuir para a redução da incidência de complicações pulmonares pós-operatórias, o tempo de recuperação e os custos hospitalares.


BACKGROUND AND METHODS: The incidence of intraoperative pulmonary collapse is elevated in patients undergoing surgery under general anesthesia with muscle relaxation/paralysis. This complication is associated with worsening intraoperative gas exchange and, in some cases, the need for prolonged postoperative respiratory support. The objective of this report was to review the pathophysiological aspects of atelectasis during general anesthesia and possible therapeutic maneuvers that could prevent and treat this complication. CONTENTS: This review discusses the concepts about the incidence of intraoperative atelectasis, factors that influence their development, both mechanical and those related to mechanical ventilator settings during the surgery, diagnostic criteria, and strategies to prevent and treat this complication. CONCLUSIONS: Understanding of the mechanisms related with the development of intraoperative pulmonary collapse, as well as its treatment, can contribute to reduce the incidence of postoperative pulmonary complications, the length of recovery and hospital costs.


JUSTIFICATIVA Y OBJETIVOS: El colapso pulmonar intraoperatorio es una complicación de elevada incidencia en pacientes sometidos a la intervención quirúrgica bajo anestesia general con relajamiento/parálisis de la musculatura. Esta complicación está asociada al empeoramiento de los cambios de gas en el intraoperatorio y en algunos casos, necesidad de soporte respiratorio prolongado en el período postoperatorio. Los objetivos de este estudio fueron los de revisar los aspectos fisiopatológicos de la formación de atelectasias durante anestesia general y las posibles maniobras terapéuticas para prevenir y tratar esa complicación. CONTENIDO: En esta revisión, los conceptos sobre la incidencia de atelectasias intraoperatorias, los factores relacionados a su desarrollo, tanto mecánicos como los relacionados al ajuste del respirador durante el procedimiento quirúrgico, los aspectos del diagnóstico y las estrategias de prevención y tratamiento fueron abordados de manera sistemática. CONCLUSIONES: La comprensión de los mecanismos relacionados al desarrollo del colapso pulmonar durante el período intraoperatorio, como también su tratamiento, pueden contribuir para la reducción de la incidencia de complicaciones pulmonares postoperatorias, el tiempo de recuperación y los costes de las internaciones en los hospitales.


Subject(s)
Humans , Anesthesia/adverse effects , Pulmonary Atelectasis/etiology , Pulmonary Atelectasis/physiopathology , Pulmonary Atelectasis/therapy
5.
São Paulo; s.n; 2008. 69 p. graf, tab, ilus.
Thesis in Portuguese | LILACS | ID: lil-540853

ABSTRACT

Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes.


A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.


Subject(s)
Humans , Male , Female , Adult , Positive-Pressure Respiration , Respiration, Artificial , Respiratory Distress Syndrome , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL