Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Korean Journal of Radiology ; : 455-463, 2009.
Article in English | WPRIM | ID: wpr-72778

ABSTRACT

OBJECTIVE: This study was designed to develop an automated system for quantification of various regional disease patterns of diffuse lung diseases as depicted on high-resolution computed tomography (HRCT) and to compare the performance of the automated system with human readers. MATERIALS AND METHODS: A total of 600 circular regions-of-interest (ROIs), 10 pixels in diameter, were utilized. The 600 ROIs comprised 100 ROIs that represented six typical regional patterns (normal, ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). The ROIs were used to train the automated classification system based on the use of a Support Vector Machine classifier and 37 features of texture and shape. The performance of the classification system was tested with a 5-fold cross-validation method. An automated quantification system was developed with a moving ROI in the lung area, which helped classify each pixel into six categories. A total of 92 HRCT images obtained from patients with different diseases were used to validate the quantification system. Two radiologists independently classified lung areas of the same CT images into six patterns using the manual drawing function of dedicated software. Agreement between the automated system and the readers and between the two individual readers was assessed. RESULTS: The overall accuracy of the system to classify each disease pattern based on the typical ROIs was 89%. When the quantification results were examined, the average agreement between the system and each radiologist was 52% and 49%, respectively. The agreement between the two radiologists was 67%. CONCLUSION: An automated quantification system for various regional patterns of diffuse interstitial lung diseases can be used for objective and reproducible assessment of disease severity.


Subject(s)
Humans , Feasibility Studies , Lung Diseases, Interstitial/diagnostic imaging , Observer Variation , Pattern Recognition, Automated/methods , Radiographic Image Interpretation, Computer-Assisted , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
2.
Korean Journal of Radiology ; : 87-96, 2006.
Article in English | WPRIM | ID: wpr-172668

ABSTRACT

OBJECTIVE: To assess the added value of coronal reformation for radiologists and for referring physicians or surgeons in the CT diagnosis of acute appendicitis. MATERIALS AND METHODS: Contrast-enhanced CT was performed using 16-detector-row scanners in 110 patients, 46 of whom had appendicitis. Transverse (5-mm thickness, 4-mm increment), coronal (5-mm thickness, 4-mm increment), and combined transverse and coronal sections were interpreted by four radiologists, two surgeons and two emergency physicians. The area under the receiver operating characteristic curve (Az value), sensitivity, specificity (McNemar test), diagnostic confidence and appendiceal visualization (Wilcoxon signed rank test) were compared. RESULTS: For radiologists, the additional coronal sections tended to increase the Az value (0.972 vs. 0.986, p = 0.076) and pooled sensitivity (92% [95% CI: 88, 96] vs. 96% [93, 99]), and enhanced appendiceal visualization in true-positive cases (p = 0.031). For non-radiologists, no such enhancement was observed, and the confidence for excluding acute appendicitis declined (p = 0.013). Coronal sections alone were inferior to transverse sections for diagnostic confidence as well as appendiceal visualization for each reader group studied (p < 0.05). CONCLUSION: The added value of coronal reformation is more apparent for radiologists compared to referring physicians or surgeons in the CT diagnosis of acute appendicitis.


Subject(s)
Middle Aged , Male , Humans , Female , Aged, 80 and over , Adult , Adolescent , Tomography, X-Ray Computed , Sensitivity and Specificity , Retrospective Studies , Referral and Consultation , Radiographic Image Enhancement , ROC Curve , Appendicitis/diagnostic imaging , Acute Disease
3.
Journal of the Korean Radiological Society ; : 255-261, 2006.
Article in Korean | WPRIM | ID: wpr-142840

ABSTRACT

PURPOSE: The aim of our study was to evaluate the value of coronal image reconstructions of HRCT with using 64 MDCT scans for the assessment of bronchiectasis. MATERIALS AND METHODS: Chest CT scans (0.6-mm collimation, table speed of 14 mm/sec and a rotation time of 0.5 sec) that employed 64 MDCT images (Somatom Sensation 64, Siemens) without contrast media were performed in 56 patients (21 males and 35 females, mean age: 55 years) who displayed hemoptysis. The images were reconstructed with a 1 mm slice thickness in the axial (10 mm apart) and coronal (10 mm apart) planes with using a high frequency algorithm, and they were sent to PACS monitors. The axial images were assessed with and without the coronal images by two radiologists at two separate occasions. The presence of bronchiectasis was decided upon by consensus diagnosis of the two radiologists. The detection rates of bronchiectasis were compared between the readings with using the axial images alone and the readings with using both the axial and coronal images. RESULTS: The detection rate of bronchiectasis was significantly higher with using both the axial and coronal images than with using with axial images alone (82.1%, 46/56 patients Vs 64.3%, 36/56 patients, respectively, p=0.001). The detection rates for all the lobes, except for the superior division of the left upper lobe, were significantly improved with using both the axial and coronal images (RUL; p=0.013, RML; p=0.002, RLL; 0.024, Lt lingular segment; p=0.004, LLL; p=0.018). CONCLUSION: The coronal images of HRCT with using 64 MDCT improved the detection rate of bronchiectasis in the patients with hemoptysis when they were used in conjunction with the standard axial images. We suggest that HRCT with the coronal images should be obtained for the patients with hemoptysis, despite that the simple chest radiographs are often normal or they have non-specific findings.


Subject(s)
Female , Humans , Male , Bronchiectasis , Consensus , Contrast Media , Diagnosis , Hemoptysis , Image Processing, Computer-Assisted , Radiography, Thoracic , Reading , Sensation , Tomography, X-Ray Computed
4.
Journal of the Korean Radiological Society ; : 255-261, 2006.
Article in Korean | WPRIM | ID: wpr-142837

ABSTRACT

PURPOSE: The aim of our study was to evaluate the value of coronal image reconstructions of HRCT with using 64 MDCT scans for the assessment of bronchiectasis. MATERIALS AND METHODS: Chest CT scans (0.6-mm collimation, table speed of 14 mm/sec and a rotation time of 0.5 sec) that employed 64 MDCT images (Somatom Sensation 64, Siemens) without contrast media were performed in 56 patients (21 males and 35 females, mean age: 55 years) who displayed hemoptysis. The images were reconstructed with a 1 mm slice thickness in the axial (10 mm apart) and coronal (10 mm apart) planes with using a high frequency algorithm, and they were sent to PACS monitors. The axial images were assessed with and without the coronal images by two radiologists at two separate occasions. The presence of bronchiectasis was decided upon by consensus diagnosis of the two radiologists. The detection rates of bronchiectasis were compared between the readings with using the axial images alone and the readings with using both the axial and coronal images. RESULTS: The detection rate of bronchiectasis was significantly higher with using both the axial and coronal images than with using with axial images alone (82.1%, 46/56 patients Vs 64.3%, 36/56 patients, respectively, p=0.001). The detection rates for all the lobes, except for the superior division of the left upper lobe, were significantly improved with using both the axial and coronal images (RUL; p=0.013, RML; p=0.002, RLL; 0.024, Lt lingular segment; p=0.004, LLL; p=0.018). CONCLUSION: The coronal images of HRCT with using 64 MDCT improved the detection rate of bronchiectasis in the patients with hemoptysis when they were used in conjunction with the standard axial images. We suggest that HRCT with the coronal images should be obtained for the patients with hemoptysis, despite that the simple chest radiographs are often normal or they have non-specific findings.


Subject(s)
Female , Humans , Male , Bronchiectasis , Consensus , Contrast Media , Diagnosis , Hemoptysis , Image Processing, Computer-Assisted , Radiography, Thoracic , Reading , Sensation , Tomography, X-Ray Computed
5.
Journal of the Korean Radiological Society ; : 455-461, 2000.
Article in Korean | WPRIM | ID: wpr-225811

ABSTRACT

PURPOSE: To evaluate the effect of reconstruction algorithms on the CT measurement of mean lung mass density and normal thoracic structures. MATERIALS AND METHODS: Forty-six patients with a 2-9cm-sized lung mass underwent thoracic CT examinations with intravenous contrast enhancement and using a CT HiSpeed Advantage scanner (GE Medical Systems). In each examination, the axial image of the lung mass was reconstructed using soft, standard, detail, and bone algorithms. The mean value and standard deviation of mass density in Hounsfield Units (HU) were measured using ROIs of three different sizes (50 mm2, 200 mm2, and 350 mm2 or more), and the same method was used to measure the density of normal lung, muscle, bone, and vessels. In 21 patients, mass density was also measured on unenhanced and delayed enhanced images and the degree of enhancement was calculated. RESULTS: The average maximum difference in mean mass density in the images of the four different algorithms was less than 1 (range, 0.1 -1.9) HU (ROI size, 350 mm2 or more), 0 -4.2 HU (200 mm 2), and 0.1 -3.6 HU (50mm2). The average maximum difference in the degree of lung mass enhancement was 0.5 -1.2 (range, 0 -1.6 )HU (ROI size, 350 mm2 or more). The mean density of the four normal thoracic structures was highest in images reconstructed with the bone algorithm, though there was no significant difference between the four different algorithms (p = 1.000). CONCLUSION: The measured mean CT density of a lung mass larger than 2 cm does not significantly change according to the reconstruction algorithm used. When using a small ROI, however, the density difference may increase.


Subject(s)
Humans , Densitometry , Lung
6.
Journal of the Korean Radiological Society ; : 739-744, 1999.
Article in Korean | WPRIM | ID: wpr-140295

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of CT and MR virtual colonoscopy using an experimental model of colonic polyposis. MATERIALS AND METHODS: Eleven pig colons ranging from 15 to 20cm in length were cleansed and a total of 99 variable sized polyps ranging from 3 to 15mm in diameter were created. The polyps were divided into three groups according to size: <5mm(n=23), 5-9mm(n=44), and ?10mm(n=32) in diameter. Each specimen was scanned using spiral CT and MRI. Each CT and MR virtual colonoscopy was independently evaluated by two radiologists blinded to the location, size and numbers of polyps, but aware that polyps were present. Interobserver agreement regarding the detection rate of the polyps during the two types of virtual colonoscopy was measured and the diagnostic accuracy of CT and MR virtual colonoscopy was compared. Results: In both CT and MR virtual colonoscopy, the detection rates determined by the two radiologists coincided in all three groups(p<0.05). The detection rates of polyps less than 5mm, between 5 and 9mm, and 10mm or larger in diameter were 74%(17/23), 89%(39/44), and 100%(32/32), respectively, in CT colonoscopy, and 61%(14/23), 89%(39/44), and 100%(32/32), respectively in MR colonoscopy. In polyps 5mm or larger, the results of the two types of virtual colonscopy coincided but in those less than 5mm in diameter, the results of MR virtual colonoscopy were slightly inferior to those of CT colonoscopy. Conclusion: Both CT and MR virtual colonoscopy provide high detection rates of colonic polyps 5mm or larger in diameter and these techniques can therefore be used to diagnose colonic mass lesions.


Subject(s)
Colon , Colonic Polyps , Colonography, Computed Tomographic , Colonoscopy , Magnetic Resonance Imaging , Models, Theoretical , Polyps , Tomography, Spiral Computed
7.
Journal of the Korean Radiological Society ; : 739-744, 1999.
Article in Korean | WPRIM | ID: wpr-140294

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of CT and MR virtual colonoscopy using an experimental model of colonic polyposis. MATERIALS AND METHODS: Eleven pig colons ranging from 15 to 20cm in length were cleansed and a total of 99 variable sized polyps ranging from 3 to 15mm in diameter were created. The polyps were divided into three groups according to size: <5mm(n=23), 5-9mm(n=44), and ?10mm(n=32) in diameter. Each specimen was scanned using spiral CT and MRI. Each CT and MR virtual colonoscopy was independently evaluated by two radiologists blinded to the location, size and numbers of polyps, but aware that polyps were present. Interobserver agreement regarding the detection rate of the polyps during the two types of virtual colonoscopy was measured and the diagnostic accuracy of CT and MR virtual colonoscopy was compared. Results: In both CT and MR virtual colonoscopy, the detection rates determined by the two radiologists coincided in all three groups(p<0.05). The detection rates of polyps less than 5mm, between 5 and 9mm, and 10mm or larger in diameter were 74%(17/23), 89%(39/44), and 100%(32/32), respectively, in CT colonoscopy, and 61%(14/23), 89%(39/44), and 100%(32/32), respectively in MR colonoscopy. In polyps 5mm or larger, the results of the two types of virtual colonscopy coincided but in those less than 5mm in diameter, the results of MR virtual colonoscopy were slightly inferior to those of CT colonoscopy. Conclusion: Both CT and MR virtual colonoscopy provide high detection rates of colonic polyps 5mm or larger in diameter and these techniques can therefore be used to diagnose colonic mass lesions.


Subject(s)
Colon , Colonic Polyps , Colonography, Computed Tomographic , Colonoscopy , Magnetic Resonance Imaging , Models, Theoretical , Polyps , Tomography, Spiral Computed
8.
Journal of the Korean Radiological Society ; : 1067-1069, 1997.
Article in English | WPRIM | ID: wpr-206335

ABSTRACT

Tracheal leiomyoma is a rare benign tumor arising from the smooth muscle in the tracheal wall. As in other cases of benign tracheal tumors, the obstructive symptoms due to leiomyoma are similar to those of asthma and bronchitis, and diagnostic delay is therefore common. We describe the case of a patient with leiomyoma arising from the trachea and review the literature, with particular emphasis on the two dimensional CT images.


Subject(s)
Humans , Asthma , Bronchitis , Leiomyoma , Muscle, Smooth , Trachea
SELECTION OF CITATIONS