Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
The Journal of Advanced Prosthodontics ; : 279-285, 2018.
Article in English | WPRIM | ID: wpr-742048

ABSTRACT

PURPOSE: The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS: Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS: The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: 4.74 ± 2.06°, coronal deviation: 1.37 ± 0.80 mm, and apical deviation: 1.77 ± 0.86 mm. The means for cast analyses were: angle deviation: 2.43 ± 1.13°, coronal deviation: 0.82 ± 0.44 mm, apical deviation: 1.19 ± 0.46 mm, and depth deviation: 0.03 ± 0.65 mm. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION: The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.


Subject(s)
Humans , Casts, Surgical , Clinical Study , Printing, Three-Dimensional , Radiotherapy Planning, Computer-Assisted , Stents , Surgery, Computer-Assisted
2.
Radiation Oncology Journal ; : 368-379, 2017.
Article in English | WPRIM | ID: wpr-52735

ABSTRACT

PURPOSE: The purpose of this study was to explore the dosimetric difference between simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) and three-dimensional conformal radiotherapy (3DCRT), and the clinical outcomes of anal squamous cell carcinoma (ASCC) chemoradiotherapy featuring SIB-IMRT. MATERIALS AND METHODS: This study included ten patients with ASCC who underwent chemoradiotherapy using SIB-IMRT with 5-fluorouracil and mitomycin C. SIB-IMRT delivered 54 Gy to each primary tumor plus metastatic lymph nodes and 45 Gy to regional lymph nodes, in 30 fractions. Four patients received additional boosts to the primary tumors and metastatic lymph nodes; the median total dose was 54 Gy (range, 54 to 60 Gy). We additionally created 3DCRT plans following the Radiation Therapy Oncology Group 9811 protocol to allow dosimetric comparisons with SIB-IMRT. Locoregional control, overall survival, and toxicity were calculated for the clinical outcome evaluation. RESULTS: Compared to 3DCRT, SIB-IMRT significantly reduced doses to the external genitalia, bladder, and intestine, delivering the doses to target and elective nodal region. At a median follow-up time of 46 months, 3-year locoregional control and overall survival rates were 88.9% and 100%, respectively. Acute toxicities were treated conservatively. All patients completed radiotherapy with brief interruptions (range, 0 to 2 days). No patient experienced ≥grade 3 late toxicity during the follow-up period. CONCLUSION: The dosimetric advantages of SIB-IMRT appeared to reduce the toxicity of chemoradiotherapy for ASCC achieving high locoregional control in the extended period.


Subject(s)
Humans , Anus Neoplasms , Carcinoma, Squamous Cell , Chemoradiotherapy , Epithelial Cells , Fluorouracil , Follow-Up Studies , Genitalia , Intestines , Lymph Nodes , Mitomycin , Radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Survival Rate , Treatment Outcome , Urinary Bladder
3.
Cancer Research and Treatment ; : 727-737, 2015.
Article in English | WPRIM | ID: wpr-74291

ABSTRACT

PURPOSE: The purpose of this study is to investigate the dosimetric and clinical influence of computed tomography-based (3-dimensional [3D]) simulation versus conventional 2-dimensional (2D)-based simulation in postoperative chemoradiotherapy (CRT) for patients with advanced gastric cancer in terms of parallel opposed anteroposterior-posteroanterior field arrangement. MATERIALS AND METHODS: A retrospective stage-matched cohort study was conducted in 158 patients treated with adjuvant CRT following curative surgery and D2 dissection from 2006 to 2008 at Samsung Medical Center: 98 patients in the 3D group; and 60 patients in the 2D group. For comparison of the dosimetric parameters between 3D plan and 2D plan, second sets of radiation treatment plans were generated according to the same target delineation method used in the 2D group for each patient in the 3D group (V2D). Acute toxicity, recurrence, and survival were analyzed. The median follow-up period was 28 months (range, 5 to 51 months). RESULTS: The 3D group showed better dose-volume histogram (DVH) profiles than the V2D group for all dosimetric parameters, including the kidneys, liver, spinal cord, duodenum, pancreas, and bowel. However, no difference in acute gastrointestinal toxicity and survival outcomes was observed between the 3D group and the 2D group. CONCLUSION: The 3D plan enabled precise delineation of the target volume and organs at risk by visualization of geometric changes in the internal organs after surgery. The DVH of normal tissues in the 3D plan was superior to that of the V2D plan, but similar clinical features were observed between the 3D group and the 2D group.


Subject(s)
Humans , Chemoradiotherapy , Cohort Studies , Duodenum , Follow-Up Studies , Kidney , Liver , Organs at Risk , Pancreas , Radiotherapy , Radiotherapy Planning, Computer-Assisted , Recurrence , Retrospective Studies , Spinal Cord , Stomach Neoplasms
4.
Radiation Oncology Journal ; : 23-30, 2014.
Article in English | WPRIM | ID: wpr-178910

ABSTRACT

PURPOSE: The goal of this study is to determine whether the magnitude of overlap between planning target volume (PTV) and rectum (Rectumoverlap) or PTV and bladder (Bladderoverlap) in prostate cancer volumetric-modulated arc therapy (VMAT) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose-volume constraints are unlikely to be met. MATERIALS AND METHODS: Fifty-seven patients with prostate cancer underwent VMAT planning using identical optimization conditions and normalization. The PTV (for the 50.4 Gy primary plan and 30.6 Gy boost plan) included 5 to 10 mm margins around the prostate and seminal vesicles. Pearson correlations, linear regression analyses, and receiver operating characteristic (ROC) curves were used to correlate the percentage overlap with dose-volume parameters. RESULTS: The percentage Rectumoverlap and Bladderoverlap correlated with sparing of that organ but minimally impacted other dose-volume parameters, predicted the primary plan rectum V45 and bladder V50 with R(2) = 0.78 and R(2) = 0.83, respectively, and predicted the boost plan rectum V30 and bladder V30 with R(2) = 0.53 and R(2) = 0.81, respectively. The optimal cutoff value of boost Rectumoverlap to predict rectum V75 >15% was 3.5% (sensitivity 100%, specificity 94%, p 10% was 5.0% (sensitivity 83%, specificity 100%, p < 0.01). CONCLUSION: The degree of overlap between PTV and bladder or rectum can be used to accurately guide physicians on the use of interventions to limit the extent of the overlap region prior to optimization.


Subject(s)
Humans , Linear Models , Organs at Risk , Prostate , Prostatic Neoplasms , Radiation Injuries , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Rectum , ROC Curve , Seminal Vesicles , Sensitivity and Specificity , Urinary Bladder
SELECTION OF CITATIONS
SEARCH DETAIL