Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Biomédica (Bogotá) ; 39(supl.2): 11-19, ago. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1038823

ABSTRACT

Resumen La miocarditis es una enfermedad inflamatoria del miocardio. Las infecciones virales son la causa más común, aunque también puede deberse a reacciones de hipersensibilidad y de etiología autoinmunitaria, entre otras. El espectro clínico de la enfermedad es variado y comprende desde un curso asintomático, seguido de dolor torácico, arritmias y falla cardiaca aguda, hasta un cuadro fulminante. El término 'fulminante' se refiere al desarrollo de un shock cardiogénico con necesidad de soporte vasopresor e inotrópico o dispositivos de asistencia circulatoria, ya sea oxigenación por membrana extracorpórea o balón de contrapulsación intraaórtico. Cerca del 10 % de los casos de falla cardiaca por miocarditis corresponde a miocarditis fulminante. La miocarditis por influenza se considera una condición infrecuente; no obstante, su incidencia ha aumentado desde el 2009 a raíz de la pandemia de influenza por el virus AH1N1. Por su parte, la miocarditis por influenza de tipo B sigue siendo una condición infrecuente. Se describen aquí dos casos confirmados de miocarditis fulminante por el virus de la influenza B atendidos en un centro cardiovascular, que requirieron dispositivos de asistencia circulatoria mecánica.


Abstract Myocarditis is an inflammatory disease of the myocardium. Viral infections are the most common cause, although it can also be due to hypersensitivity reactions and autoimmune etiology, among other causes. The clinical spectrum of the disease is varied, from an asymptomatic course, followed by chest pain, arrhythmias, and acute heart failure, to a fulminant episode. The term fulminant refers to the development of cardiogenic shock with a need for vasopressor support and inotropic or assisted circulation devices either extracorporeal membrane oxygenation (ECMO) or intra-aortic counterpulsation balloon. About 10% of cases of heart failure due to myocarditis correspond to fulminant myocarditis. Influenza myocarditis has been considered an infrequent condition. However, its incidence has increased since 2009 as a result of the AH1N1 pandemic; otherwise, myocarditis due to the Influenza type B virus remains an infrequent entity. We describe the experience in a cardiovascular center of two confirmed cases of fulminant myocarditis due to influenza B that required circulatory assistance devices.


Subject(s)
Female , Humans , Middle Aged , Young Adult , Influenza B virus , Shock, Cardiogenic/etiology , Influenza, Human/complications , Myocarditis/etiology , Antiviral Agents/therapeutic use , Influenza B virus/isolation & purification , Pericardial Effusion/etiology , Shock, Cardiogenic/drug therapy , Shock, Cardiogenic/therapy , Vasoconstrictor Agents/therapeutic use , Extracorporeal Membrane Oxygenation , Hemofiltration , Fatal Outcome , Combined Modality Therapy , Advanced Cardiac Life Support , Emergencies , Influenza, Human/drug therapy , Influenza, Human/virology , Oseltamivir/therapeutic use , Acute Kidney Injury/etiology , Acute Kidney Injury/therapy , Intra-Aortic Balloon Pumping , Myocarditis/diagnostic imaging
2.
Rev. argent. cardiol ; 82(4): 292-296, ago. 2014. graf, tab
Article in Spanish | LILACS | ID: lil-734513

ABSTRACT

Introducción La perspectiva de un tiempo de asistencia circulatoria prolongada en lista de espera de trasplante cardíaco implica complicaciones asociadas. Con el implante anterógrado del balón de contrapulsación por vía subclavia, a diferencia del acceso convencional, podrían evitarse o al menos limitarse los efectos adversos de la asistencia. Objetivo Considerar la asistencia circulatoria con balón de contrapulsación implantado por subclavia izquierda como puente al trasplante. Material y métodos Se incluyeron pacientes en lista para trasplante cardíaco con descompensación hemodinámica y presunción de un tiempo prolongado de asistencia que recibieron el implante anterógrado del balón de contrapulsación a través de la arteria subclavia izquierda. Resultados Entre agosto de 2007 y julio de 2012, en 38 pacientes se efectuó el implante del balón de contrapulsación en forma anterógrada, sin complicaciones. En 29 (76,3%) pacientes se realizó el trasplante bajo dicho apoyo y en 9 pacientes se requirió la transición hacia una forma más compleja de asistencia. De estos, en 5 (13,2%) se realizó el trasplante y los 4 (10,5%) pacientes restantes fallecieron. El tiempo de asistencia con balón fue de 24 días (5-68 días); la mayoría de los pacientes lograron movilizarse, e incluso deambular, bajo esta asistencia. El número de complicaciones apreciadas fue bajo: 1 (2,6%) paciente presentó hematoma mayor local, en 1 (2,6%) paciente se produjo rotura del catéter, que debió reemplazarse, y en 1 (2,6%) se evidenció pérdida del pulso distal, sin necesitar intervención alguna. Al comparar la evaluación hemodinámica previa y posterior al implante se observó mejoría, con incremento de los parámetros de la función ventricular (volumen minuto e índice cardíaco) y reducción de las presiones de llenado. Conclusiones Pacientes seleccionados con insuficiencia cardíaca avanzada descompensada pueden ser estabilizados y apoyados durante un período prolongado mediante el empleo del balón de contrapulsación por acceso subclavio. Esta técnica se asoció con un número bajo de complicaciones y permitió, a diferencia del acceso retrógrado, la movilización de la mayoría de los pacientes durante la espera del trasplante.


Introduction The possibility of prolonged circulatory assistance on the waiting list for heart transplantation has associated complications. Different from the conventional access, antegrade balloon pump implantation through the subclavian artery could avoid or, at least, limit the adverse effects of assistance. Objective: The aim of this study was to consider circulatory support using intra-aortic balloon pump implantation through the left subclavian artery as bridge to transplantation. Methods Patients on the waiting list for heart transplantation with acute decompensation and expected prolonged waiting interval received antegrade balloon pump implantation through the left subclavian artery. Results: Between August 2007 and July 2012, 38 patients underwent uneventful antegrade balloon pump implantation. Twenty-nine patients (76.3%) were transplanted under circulatory support and 9 patients required transition to more complex support techniques. Among these patients 5 (13.2%) were transplanted while the other 4 (10.5%) died. Average circulatory assistance with intra-aortic balloon pump was 24 days (5 to 68 days) during which the majority of patients were able to move and even ambulate. Observed complications were low; 1 patient (2.6%) developed a big local hematoma, 1 (2.6%) presented catheter rupture and replacement, and 1 (2.6%) experienced distal pulse loss which was managed in a conservative way. Hemodynamic assessment before and after implantation showed improved systolic function (cardiac output and cardiac index) and reduced filling pressures. Conclusions Selected patients with decompensated end-stage heart failure could be stabilized and supported for a prolonged period of time using intra-aortic balloon pump implanted through the subclavian artery. This technique was associated with a low number of complications and, different from the conventional retrograde access, it allowed mobility in the majority of patients while awaiting transplantation.

3.
Acta paul. enferm ; 25(spe1): 13-19, 2012. tab
Article in English | LILACS, BDENF | ID: lil-666727

ABSTRACT

OBJECTIVE: To develop a protocol of care for patients with Intra-Aortic Balloon and validate the content of this protocol. METHODS: Study of quantitative and descriptive approach. The methodology followed three steps: development of the instrument; content validity and reliability verification of the protocol for the analysis of agreement between specialists with greater experience. The study included 48 specialists, including physicians and nurses experienced in patient care in use of balloon. Items considered valid achieved at least 75% of consensus before the analysis of agreement between evaluators. RESULTS: We evaluated 36 items, of these, 20 were considered valid. The reliability was also verified, using consistency of the responses of more experienced evaluators. Among the items submitted to new statistical analysis by these evaluators, only two were considered valid. CONCLUSION: Based on the content validation, a protocol with 22 items concerning patient care without the use of intra-aortic balloon was developed.


OBJETIVOS: Elaborar um protocolo de cuidados a pacientes com Balão Intra Aórtico e validar o conteúdo desse protocolo. MÉTODOS: Estudo de abordagem quantitativa, descritivo. A trajetória metodológica seguiu três etapas: elaboração do instrumento; validação do conteúdo e verificação da confiabilidade do protocolo pela análise de concordância entre peritos com maior tempo de experiência. Participaram do estudo 48 peritos, entre médicos e enfermeiros, experientes em assistência ao paciente em uso do balão. Os itens considerados válidos obtiveram consenso mínimo de 75% perante a análise de concordância entre os avaliadores. RESULTADOS: Foram avaliados 36 itens, destes, 20 foram considerados válidos. Verificou-se também a confiabilidade, utilizando a congruência das respostas dos avaliadores mais experientes. Dos itens submetidos à nova análise estatística por esses avaliadores, apenas dois foram considerados válidos. CONCLUSÃO: Com base na validação do conteúdo, elaborou-se um protocolo com 22 itens referentes aos cuidados a paciente sem uso do Balão Intra-Aórtico.


OBJETIVOS: Elaborar un protocolo de cuidados a pacientes con Balón Intraaórtico y validar el contenido de ese protocolo. MÉTODOS: Estudio de abordaje cuantitativo, descriptivo. La trayectoria metodológica siguió tres etapas: elaboración del instrumento; validación del contenido y verificación de la confiabilidad del protocolo por el análisis de concordancia entre peritos con mayor tiempo de experiencia. Participaron en el estudio 48 peritos, entre médicos y enfermeros, con experiencia en asistencia al paciente en uso del balón. Los items considerados válidos obtuvieron consenso mínimo del 75% frente al análisis de concordancia entre los evaluadores. RESULTADOS: Fueron evaluados 36 items, de éstos, 20 fueron considerados válidos. Se verificó también la confiabilidad, utilizando la congruencia de las respuestas de los evaluadores más experientes. De los items sometidos al nuevo análisis estadístico por esos evaluadores, apenas dos se considerarons válidos. CONCLUSIÓN: Con base en la validación del contenido, se elaboró un protocolo con 22 items referentes a los cuidados al paciente sin uso del Balón Intraaórtico.


Subject(s)
Humans , Patient Care , Intra-Aortic Balloon Pumping , Nursing Care , Validation Studies as Topic , Clinical Protocols , Evaluation Studies as Topic , Epidemiology, Descriptive
4.
Rev. latinoam. enferm ; 17(5): 658-663, Sept.-Oct. 2009. tab
Article in English | LILACS, BDENF | ID: lil-532881

ABSTRACT

OBJECTIVES: To describe complications associated to the use of intra-aortic balloon pumps (IABP), and their relationship with dwelling time, presence of risk factors/comorbidities, and nursing records. METHODS: Retrospective cohort study, in which medical records were analyzed through the completion of specifically designed forms. RESULTS: In total, 104 patients were included, with mean age 65±11 years, 52 percent men; 26 (25 percent) of them presented vascular complications, more frequently ischemia (25 percent); peripheral vascular disease was the risk factor/comorbidity more frequently related to complications (56.3 percent; p=0.003). Nursing records showed that the use of catheter was recorded in 30 cases (29 percent), and the patient's clinical situation after its removal in 28 cases (27 percent). CONCLUSION: This study showed that the frequency of complications related to IABP is high. Considering risk factor/comorbidity factors, peripheral vascular disease was significantly associated to complications. Nursing records were sub-optimal.


Este estudio tuvo como objetivos describir las complicaciones provenientes de la utilización del balón intraaórtico (BIA), relacionándolas con el tiempo de permanencia, con la presencia de factores de riesgo/enfermedades concomitantes y con los registros de enfermería. Se utilizó como método la cohorte histórica, con análisis de fichas por medio del llenado de un instrumento construido específicamente para el estudio. Después de la evaluación de 104 pacientes, edad promedio 65±11, 52 por ciento sexo masculino, los resultados mostraron que 26 (25 por ciento) presentaron complicaciones vasculares, siendo la isquemia (25 por ciento) la más incidente; entre los factores de riesgo/enfermedades concomitantes, el que más se relacionó con complicaciones fue la enfermedad vascular periférica (56,3 por ciento, p=0,003). En lo que se refiere a las evaluaciones de enfermería, 30 (29 por ciento) presentaban registro del uso del catéter, y 28 (27 por ciento) relataban el estado clínico del paciente después de su retirada. Se concluye que este estudio demostró que el índice de complicaciones es todavía alto cuando relacionado al BIA. Entre los factores de riesgo/enfermedades concomitantes, la enfermedad vascular periférica fue significativamente relacionada con complicaciones. Los registros de los enfermeros no fueron exhautivos.


Este estudo teve como objetivos descrever as complicações decorrentes da utilização do balão intra-aórtico (BIA), relacionando-as com o tempo de permanência, com a presença de fatores de risco/comorbidades e com os registros de enfermagem. Utilizou-se como método a coorte histórica, com análise de prontuários por meio de preenchimento de instrumento específico para o estudo. Após avaliação de 104 pacientes, idade média 65±11, 52 por cento sexo masculino, os resultados mostraram que 26 (25 por cento) apresentaram complicações vasculares, sendo a isquemia (25 por cento) a mais incidente; entre os fatores de risco/comorbidades, o que mais se relacionou com complicações foi a doença vascular periférica (56,3 por cento, p=0,003). Quanto às evoluções de enfermagem, 30 (29 por cento) apresentavam registro do uso do cateter, e 28 (27 por cento) relatavam o estado clínico do paciente após a sua retirada. Conclui-se que este estudo demonstrou que o índice de complicações ainda é alto quando relacionado ao BIA. Dentre os fatores de risco/comorbidades, a doença vascular periférica foi significativamente relacionada com complicações. Os registros dos enfermeiros foram subótimos.


Subject(s)
Female , Humans , Male , Middle Aged , Intra-Aortic Balloon Pumping/adverse effects , Cohort Studies , Hospitalization , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL