Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Acta Anatomica Sinica ; (6): 82-86, 2023.
Article in Chinese | WPRIM | ID: wpr-1015258

ABSTRACT

Objective To provide anatomical basis for clinical treatment of acromioclavicular joint dislocation by studying the morphology of coracoid process of human scapula. Methods A total of 500 patients with shoulder injury were selected from the Affiliated Hospital of Traditional Chinese Medicine of Southwest Medical University in Sichuan Province, and 300 patients were selected as subjects, including 159 cases of right shoulder and 141 cases of left shoulder. CT scan images and 3D reconstruction results of scapula of the subjects were collected. The basic morphological characteristics of coracoid process CT images of the subjects were observed, and the relevant parameters were measured, including the longest horizontal distance of the coracoid process tip and the thickness of the midpoint (cd, pp’), the distance from the upper part of the coracoid process scapula to the base and the thickness of the midpoint (mn, kk’). The distance from the apex of the coracoid process to the base of the coracoid process (ab), the longest horizontal distance of the recursion part of the coracoid process (ef), the distance of as (point s was the intersection of point a perpendicular to mn), the distance of hj (point h and j were the intersection of the base of the coracoid process and the recursion part respectively), and ik (point i was the intersection of point k perpendicular to mn and the coracoid process retraction). Results According to the morphological characteristics of coracoid process, they were divided into five types, including peanut 29. 7%; Short rod type accounted for 27. 4%; Melon seed type accounted for 12. 6%; Rod type accounted for 17. 0%; Wedge type accounted for 13. 3%. Through data comparison, it was found that the distance ef and distance hj on the left were larger than those on the right, P<0. 05. All types had statistical difference in comparison distance cd, P<0. 05. The melon seed type showed statistical differences with peanut type, wedge type, long stick type and short stick type in thickness pp’, distance ab and as of point p, P<0. 05. In the comparison of point K thickness kk’, there was statistical difference between melon seed type and other four types, P<0. 05. In the distance ab comparison, there was statistical difference between the short bar type and the other four types, P < 0. 05. Conclusion The study on the morphology of coracoid process can provide anatomical basis for clinical reconstruction of coracoid ligament to treat acromioclavicular joint dislocation.

2.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1370-1374, 2023.
Article in Chinese | WPRIM | ID: wpr-1009069

ABSTRACT

OBJECTIVE@#To evaluate the effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures.@*METHODS@#The data of 17 patients with Cho type ⅡC distal clavicular fractures, who were treated with Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor between June 2019 and June 2021, was retrospectively analyzed. There were 11 males and 6 females with an average age of 38.7 years (range, 19-72 years). The fractures were caused by falling in 12 cases and traffic accident in 5 cases. All patients had fresh closed fractures. The interval from injury to operation was 1-5 days (mean, 2.6 days). The preoperative injury severity score (ISS) was 6-27 (mean, 10.2). The operation time, intraoperative blood loss, hospital stay, fracture healing, and postoperative complications were analyzed. The shoulder joint function was evaluated by disabilities of the arm, shoulder, and hand (DASH) score and Constant score at last follow-up.@*RESULTS@#All operations were completed successfully. The operation time was 20-50 minutes (mean, 31.6 minutes). The intraoperative blood loss was 30-100 mL (mean, 50.6 mL). The hospital stay was 4-9 days (mean, 5.3 days). All incisions healed by first intention. All patients were followed up 12-16 months (mean, 13 months). All clavicle fractures healed, and the healing time was 8-15 weeks (mean, 11 weeks). No complications such as fracture displacement or nonunion caused by internal fixation failure occurred. During the follow-up, skin irritation caused by the Kirschner wire withdrawal occurred in 3 cases. The Kirschner wires were removed after fracture healing in 17 patients. At last follow-up, the Constant score of shoulder joint was 90-100 (mean, 98.2). The DASH score was 0-10 (mean, 1.5).@*CONCLUSION@#Kirschner wire fixation combined with coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures has less postoperative complications and slight complications. It is convenient to remove the internal fixator. The Kirschner wire does not fix the distal clavicle fracture through the acromion, which has little effect on shoulder joint function and can obtain good effectiveness.


Subject(s)
Male , Female , Humans , Adult , Bone Wires , Clavicle/injuries , Suture Anchors , Blood Loss, Surgical , Retrospective Studies , Fractures, Bone/surgery , Fracture Fixation, Internal , Ligaments, Articular/surgery , Postoperative Complications , Treatment Outcome
3.
Chinese Journal of Orthopaedic Trauma ; (12): 120-126, 2022.
Article in Chinese | WPRIM | ID: wpr-932301

ABSTRACT

Objective:To compare anatomical locking plate fixation with versus without reconstruction of the coracoclavicular ligament in the treatment of acute and old Neer Ⅱb unstable distal clavicle fractures.Methods:From January 2015 to November 2020, 80 Neer Ⅱb distal clavicle fractures were treated at Department of Orthopaedics, The First Hospital Affiliated to China Pharmaceutical University. There were 49 males and 31 females, aged from 32 to 78 years (average, 47.8 years). Of the 50 fresh fractures, 25 were treated by internal fixation with anatomical locking plate of distal clavicle plus reconstruction of the coracoclavicular ligament with suture anchor (reconstruction group A) while the other 25 by only internal fixation with anatomical locking plate of distal clavicle (non-reconstruction group A). Of the 30 old fractures which had not got united over 3 weeks after injury, 15 were treated by internal fixation with anatomical locking plate of distal clavicle plus reconstruction of the coracoclavicular ligament with suture anchor (reconstruction group B) while the other 15 by only internal fixation with anatomical locking plate of distal clavicle (non-reconstruction group B). At 1, 3 and 6 months postoperatively, Constant-Murley scale and visual analogue scale (VAS) were used to evaluate shoulder function and pain. X-ray follow-ups were conducted to measure the coracoclavicular distance and observe fracture union and complications at the last follow-up.Results:All the 80 patients were followed up for 6 to 24 months (average, 13.8 months). For reconstruction group A and non-reconstruction group A, respectively, the union time for fresh fractures was (11.7±2.8) weeks versus (13.4±1.3) weeks, the rate of coracoclavicular distance increase 12.7%±6.2% versus 14.2%±8.0%, the Constant-Murley score 92.2±4.4 versus 90.9±5.7, showing no statistically significant difference between the 2 groups (all P>0.05). For reconstruction group B and non-reconstruction group B, respectively, the union time for old fractures was (12.8±1.9) weeks versus (19.4±6.7) weeks, the rate of coracoclavicular distance increase 12.3%±6.7% versus 21.5%±13.1%, the Constant-Murley score 93.0±5.9 versus 83.5±8.5, showing statistically significant differences between the 2 groups (all P<0.05). Conclusions:For fresh Neer Ⅱb distal clavicle fractures, simple anatomical locking plate fixation can achieve satisfactory curative efficacy without additional reconstruction of the coracoclavicular ligament. However, for old Neer IIb distal clavicle fractures, additional reconstruction of the coracoclavicular ligament can better maintain the stability of the acromioclavicular joint, reduce the risk of internal fixation failure, and achieve better outcomes.

4.
Acta Anatomica Sinica ; (6): 954-959, 2021.
Article in Chinese | WPRIM | ID: wpr-1015387

ABSTRACT

Objective To measure the anatomical morphology of coracoclavicular ligament based on fresh cadavers, and to provide anatomical basis for anatomical reconstruction of coracoclavicular ligament. Methods A total of 52 the acromioclavicular joints (fresh body specimen) was dissected, and the anatomical characteristics of coracoclavicular ligament were observed by dissecting acromioclavicular joint specimens. The anatomic data of which the length of the conoid ligament (QR), the length of the trapezoid ligament (ST) ; the distance from the conoid ligament attachment on coracoid to coracoid tip (RV), the distance from the trapezoid ligament attachment on coracoid to coracoid tip (TV), the distance form conoid ligament attachment on the clavicular to acromioclavicular joint (QU), the distance form the trapezoid ligament attachment on the clavicular to acromioclavicular joint (SU), the distance from supraclavicular plane to subcoracoid plane (WX) were measured ; and the mean diameter of the trapezoid ligament attachment on the clavicular (ā), the mean diameter of the conoid ligament attachment on the clavicular(b¯), the mean diameter of the trapezoid ligament attachment on the coracoid (c¯), the mean diameter of the conoid ligament attachment on the coracoid (d¯) were calculation. The measurement result underwent statistical analysis. Results The minimum diameter of the trapezoid ligament attachment on the clavicular and coracoid on the left and right sides, respectively. There were no significant differences in those anatomical morphology of the coracoclavicular ligament (P>0.05). The anatomical morphology of the diameter of coracoclavicular ligament attachment on the male and female had no significant difference (P>0.05). The maximum length of the conoid ligament was (14.19±2. 43/15. 87±2. 99) mm on the left and right sides, respectively. The distance from the conoid ligament attachment on coracoid to coracoid tip was ( 36. 66 ± 4. 25/33. 61 ± 3. 45 ) mm on the left and right sides, respectively. The mean diameter of the conoid ligament attachment on the clavicular and coracoid was (11.95± 1.43/ 11.23± 1.12)mm and (9.20± 1.60/7.90±0.76) mm on the left and right sides, respectively. There were significant differences in those anatomical morphology of the coracoclavicular ligament(P 0.05). The anatomical morphology of the coracoclavicular ligament on the male and female had no significant difference (P>0.05). Conclusion The comprehensive measurement of anatomical morphology of coracoclavicular ligament can provide an anatomical basis for shoulder joint diseases related to coracoclavicular ligament injury. It will help surgical staff perform a complete anatomic reconstruction of coracoclavicular ligaments for the surgical treatment of dislocation of the acromioclavicular joint.

5.
China Journal of Orthopaedics and Traumatology ; (12): 237-242, 2021.
Article in Chinese | WPRIM | ID: wpr-879422

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of titanium cable biomimetic reconstruction of coracoclavicular ligament and clavicular hook plate in the treatment of acromioclavicular joint dislocation.@*METHODS@#The clinical data of 39 patients with severe acute acromioclavicular joint dislocation from January 2017 to December 2018 were retrospectively analyzed, 19 patients in double strand titanium cable group, including 13 males and 6 females, aged from 26 to 67 years old; Rockwood classification:10 cases of type Ⅲ, 4 cases of type Ⅳ and 5 cases of type Ⅴ;8 cases of traffic injury and 11 cases of fall injury;the time from injury to operation was 3 to 6 days. There were 20 patients in steel plate group, including 15 males and 5 females, aged from 25 to 71 years old. Rockwood classification:11 cases of type Ⅲ, 4 cases of typeⅣ, 5 cases of type Ⅴ;7 cases of traffic injury, 13 cases of fall injury;the time from injury to operation was 2 to 7 days. The length of incision, operation time, intraoperative blood loss, cost, VAS score before and after operation, and Constant-Murley score before and after operation were compared between two groups. Postoperative X-ray films were taken to observe the reduction and maintenance of acromioclavicular joint dislocation. Complications were recorded.@*RESULTS@#Thirty-six patients were followed up for 12 to 14 months. The amount of intraoperative blood loss in the two groups was basically the same. The operation incision in double strand titanium cable group was shorter, the operation time in steel plate group was shorter, and the operation cost in double strand titanium cable group was less. One week and one year after operation, the pain of double strand titanium cable group was less than that of steel plate group. One year after operation, the Constant-Murley score of double strand titanium cable group was higher than that of steel plate group. The postoperative X-ray showed that the acromioclavicular joint in double strand titanium cable group was well reduced, and there was 1 case with slight reduction loss. In the plate group, there was no reduction loss after removal of the clavicular hook plate, and 8 patients had distal clavicular bone atrophy or acromion bone resorption. In steel plate group, 4 cases had long-term postoperative pain, postoperative dysfunction and other complications.@*CONCLUSION@#The clinical effect of coracoclavicular ligament reconstruction with double strand titanium cable is better than that of clavicular hook plate in the treatment of severe acute acromioclavicular joint dislocation, with less trauma (no secondary operation) and lower cost.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Acromioclavicular Joint/surgery , Bone Plates , Joint Dislocations/surgery , Retrospective Studies , Titanium , Treatment Outcome
6.
Chinese Journal of Tissue Engineering Research ; (53): 1417-1422, 2020.
Article in Chinese | WPRIM | ID: wpr-847776

ABSTRACT

BACKGROUND: There is no uniform standard for acromioclavicular dislocation. Clavicular hook plate fixation is a commonly used fixation method clinically, but minimally invasive ligament reconstruction technology and arthroscopic surgery have become a research hotspot. OBJECTIVE: To observe the application value of suture bridge with thread anchor under arthroscopy in the treatment of acromioclavicular dislocation. METHODS: Patients with Tossy type III acromioclavicular dislocation who were admitted to Department of Orthopedic Surgery of General Hospital of Jizhong Energy Xingtai Mining Group between January 2016 and April 2018 were selected as the subjects. The patients were randomly divided into two groups. The patients in the arthroscopy group were treated with arthroscopic suture bridge technique with suture anchor for reduction and fixation, while those in the clavicle hook plate group were treated with clavicular hook plate for internal fixation. The length of surgical incision, duration of surgery, hospitalization time and time to return to work of both groups were recorded. The shoulder function was evaluated according to the Lazzcano criterion of curative effect at 3, 6 and 12 months after surgery. The visual analogue scale score of shoulder pain, abduction and raising, forward bend and raising were compared between the two groups. All patients were followed up for 1 year to record the occurrence of complications. This study was approved by the Medical Ethics Committee of General Hospital of Jizhong Energy Xingtai Mining Group. All subjects signed the informed consent. RESULTS AND CONCLUSION: (1) There was no significant difference in the duration of surgery between the two groups (P > 0.05). The surgical incision, hospitalization time and time to return to work of the arthroscopy group were significantly better than those of the clavicle hook plate group (P 0.05). (3) Visual analogue scale scores of the two groups showed a decreasing trend at 3, 6 and 12 months after surgery (P < 0.01). The visual analogue scale score of arthroscopy group was significantly lower than that of the clavicle hook plate group at the same time point (P < 0.01). (4) Angles of abduction and raising, forward bend and raising of both groups showed an increasing trend at 3, 6 and 12 months after surgery (P < 0.01). The angles of abduction and raising, forward bend and raising of the arthroscopy group were larger than those of the clavicle hook plate group at the same time point (P < 0.01). (5) The 1-year follow-up results showed that the incidence of complications in the arthroscopy group (6%) was significantly lower than that in the clavicle hook plate group (63%) (P < 0.01). (6) Compared with clavicular hook plate fixation, the technique of suture anchors under arthroscopy has the advantages of small trauma, quick recovery, fewer complications and no need to remove endografts again. Meanwhile, the surgery can also clearly diagnose the concomitant lesions in the joints and treat them when necessary, so as to improve the treatment effect.

7.
Journal of Central South University(Medical Sciences) ; (12): 400-405, 2020.
Article in English | WPRIM | ID: wpr-827428

ABSTRACT

OBJECTIVES@#To explore the safety and effectiveness of arthroscopic reconstruction of coracoclavicular ligament by suspensory fixation to manage the acute acromioclavicular joint dislocation.@*METHODS@#From January 2016 to December 2017, 18 cases of acute acromioclavicular joint dislocation were carried out with arthroscopic reconstruction of coracoclavicular ligament by double Endobutton plate suspensory fixation. Anteroposterior view X-ray plain radiographs were obtained on the second day, 6 months and 12 months after the surgery, MRI was performed in 1 year after operation. Meanwhile, subjective and objective scoring were obtained by Vsual Analogue Scale (VAS), Rating Scale of the American Shoulder and Elbow Surgeons (ASES) and University of California at Los Angeles Shoulder Rating Scale (UCLA).@*RESULTS@#All patients were followed up for 12 to 30 months (an average of 18 months). There was no patient with infection, neurovascular injury, loosening and breakage of internal fixation, re-dislocation of acromioclavicular joint, clavicular fracture, coracoid process fracture, etc. Postoperative X-ray showed that all acromioclavicular joints were completely relocated. The follow-up of MRI after 1 year showed no obvious dislocation of acromioclavicular joint and good recovery of acromioclavicular space. Postoperative shoulder joint function, VAS, ASES, UCLA and acromioclavicular distance were significantly improved compared with those before surgery, with statistically significant differences (all <0.05).@*CONCLUSIONS@#Arthroscopic reconstruction of coracoclavicular ligament by suspensory fixation to manage the acute acromioclavicular joint dislocation has the advantages of minimal invasive, rapid functional recovery and less complications and satisfactory early clinical results.


Subject(s)
Humans , Acromioclavicular Joint , Diagnostic Imaging , General Surgery , Follow-Up Studies , Joint Dislocations , Diagnostic Imaging , General Surgery , Magnetic Resonance Imaging , Shoulder Dislocation , Diagnostic Imaging , General Surgery , Treatment Outcome
8.
Chinese Journal of Trauma ; (12): 143-149, 2019.
Article in Chinese | WPRIM | ID: wpr-745033

ABSTRACT

Objective To compare the efficacy between hook plate combined with coracoclavicular ligament functional reconstruction by conjoined tendon transfer and single hook plate surgery in the treatment of Rockwood type Ⅲ and type Ⅴ acute acromioclavicular joint dislocations.Methods A prospective cohort study was conducted to analyze the clinical data of 37 patients with Rockwood type Ⅲ and Ⅴ acute acromioclavicular dislocations admitted to Jiangning Hospital Affiliated to Nanjing Medical University from October 2011 to April 2016.According to the random number method,the patients were divided into combined tendon and ligament reconstruction group (ligament reconstruction group,19 patients) and clavicular hook plate group (single plate group,18 patients).In the ligament reconstruction group,there were 14 males and five females,aged (47.0 ± 11.4) years,and there were 10 patients with type Ⅲ and nine with type Ⅴ.In the simple plate group,there were 12 males and six females,aged (45.0 ± 11.2)years,and there were 11 patients with type Ⅲ and seven with type Ⅴ.In the ligament reconstruction group,the acromioclavicular joint was reduced by clavicular hook plate,and the oblique ligament and the conical ligament were reconstructed by lateral half-inversion of the short head tendon of biceps brachii combined with tendon.The double-bundle functional reconstruction of coracoclavicular ligament was performed.In single plate group,hook plate was used to reduce acromioclavicular joint.The intraoperative blood loss,incision length,operation time,and visual analogue score (VAS) before operation and after 1 year follow-up were compared.Constant-Murley score and Karlsson score were used to evaluate the effect of operation.X-ray films were taken regularly to observe the reduction and maintenance of acromioclavicular joint dislocation.The complications were recorded.Results All patients were followed up for 17-24 months [(20.0 ± 1.7) months].There was no significant difference in intraoperative blood loss between the two groups (P > 0.05).In the ligament reconstruction group and single plate group,the incision length was (13.4 ± 0.8) cm and (6.6 ± 0.7) cm (P < 0.05);the operation time was (88.7 ± 8.3) minutes and (54.1 ± 7.3) minutes (P < 0.05);the preoperative VAS score was (7.5 ± 0.9) points and (7.3 ± 0.7) points (P > 0.05);the VAS at 1 year after operation was (2.1 ± 0.9) points and (3.8 ± 1.4) points (P < 0.05).X-ray showed good reduction of acromioclavicular joint in ligament reconstruction group,with no loss of reduction occurred after removal of hook plate.In the simple plate group,loss of reduction,resorption of distal clavicle bone and bone fusion occurred after removal of hook plate.The Constant-Murley scores in the ligament reconstruction group and the single plate group were (89.5 ± 2.9) points and (79.6 ± 5.0) points respectively;the excellent and good rates of Karlsson score were 89.5% (17/19) and 61.1% (11/18) (both P < 0.05),respectively.In the ligament reconstruction group,one patient complained of pain and swelling at the tendon.In the single plate group,loss of reduction occurred in three patients after removal of internal fixator;obvious subacromial osteolysis was seen in seven patients at 1 year after operation;and impingement sign was positive in nine patients at 1 year after operation.Conclusion The overall surgical effect of hook plate combined with coracoclavicular ligament functional reconstruction by conjoined tendon transfer is superior to single hook plate surgery in the treatment of type Rockwood Ⅲ and Rockwood Ⅴ acute acromioclavicular joint dislocations,though with longer operation time and bigger incision.

9.
Journal of the Korean Shoulder and Elbow Society ; : 93-99, 2019.
Article in English | WPRIM | ID: wpr-763620

ABSTRACT

BACKGROUND: Modified Phemister operation has been widely used for the treatment of acute acromioclavicular (AC) joint dislocation. Additionally, the use of suture anchor for coracoclavicular (CC) fixation has been reported to provide CC stability. This study was conducted to evaluate the clinical and radiological results of a modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation. METHODS: Seventy-four patients underwent the modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation and were followed-up for an average of 12.3 months. The visual analogue scale (VAS), range of motion, Constant score, and Korean shoulder scoring system (KSS) were used for clinical assessment. Acromioclavicular interval (ACI), coracoclavicular distance (CCD), and acromioclavicular distance (ACD) were obtained to evaluate the radiological assessments. RESULTS: At the last follow-up, the mean VAS Score was 1.7 points, the mean joint range of the forward flexion was 164.6°, external rotation at the side was 61.2°, and internal rotation to the posterior was a level of T12. The mean Constant score and the mean KSS was 82.7 points and 84.2 points, respectively. At the mean ACI, CCD, and ACD, significant differences were found preoperatively and at the last follow-up. When the ACI, CCD, and ACD were compared with the contralateral unaffected shoulder at the last follow-up, the affected shoulders had significantly higher values. CONCLUSIONS: The modified Phemister operation with CC ligament augmentation using suture anchor is clinically and radiologically effective at acute AC joint dislocation.


Subject(s)
Humans , Acromioclavicular Joint , Joint Dislocations , Follow-Up Studies , Joints , Ligaments , Range of Motion, Articular , Shoulder , Suture Anchors , Sutures
10.
Article | IMSEAR | ID: sea-198456

ABSTRACT

Background: Surgical procedures as coracoid osteotomy, transfer, and fixation are used for management ofrecurrent anterior shoulder instability. However, the peculiar anatomy of bony and soft tissue footprints of thecoracoid, as they relate to these surgical procedures, need further detailed studies owing to its clinical importance.Aim of the work: to obtain safety margin for osteotomy of the coracoid process.Materials and methods: The material of this work included twenty upper limbs of formalin preserved specimensobtained from the dissecting room of anatomy department, faculty of medicine, Alexandria University. Dimensionsof the coracoid process were recorded. Anatomical measurements between the tip of the coracoid process to theanterior and posterior margins of the tendon of pectoralis minor were recorded. Distances between the tip of thecoracoid process and the anterior and posterior margins of coracoacromial ligament, coracohumeral ligament,and the most distal point of conoid and trapezoid ligaments were recorded.Results: The mean length, width, and height of the coracoid were 4.25, 1.4, 1.16 cm respectively. The meandistance between the tip of the coracoid process to the anterior and posterior margins of pectoralis minor were1.07 and 2.04 cm respectively. The mean distance between tip of coracoid process and coracoacromial ligament(anterior and posterior margins), coracohumeral, conoid and trapezoid ligaments were 1.32, 2.19, 1.11, 3.70and 2.73 cm respectively.Conclusion: A safety margin of 2.35 cm from the tip of the coracoid process is recommended to avoid injury ofcoracoclavicular ligament. This distance was correlated with the distance between the tip and the posteriormargin of pectoralis minor muscle.

11.
Article | IMSEAR | ID: sea-187686

ABSTRACT

Background: The acromioclavicular (AC) joint is commonly involved in traumatic injuries in male athletic population. Treatment of acute complete AC dislocation is controversial in literature. Both conservative and surgical treatment has been reported with similar results. Methods: We report a prospective study of 17 patients of Acromioclavicular dislocations (Type III) managed with screw and tension band wiring and were followed up for a period of 3 years. Repair of Coracoclavicular Ligament was performed if found completely torn. Results: Patients were assessed on basis of pain relief, tenderness, functional ability, range of motion at shoulder and cosmosis. Conclusion:Fixation with screw and Tension band wiring is a simple, easy, less time consuming surgical technique allowing faster rehabilitation in young and adult active patients to achieve a stable, pain free shoulder with no serious intra-operative or post-operative complications.

12.
Journal of Medical Biomechanics ; (6): E343-E347, 2018.
Article in Chinese | WPRIM | ID: wpr-803718

ABSTRACT

Objective To conduct a comparative study of the biomechanical characteristics of anatomical and vertical reconstruction for the coracoclavicular ligament. Methods Thirty fresh adult cadaveric specimens of the shoulder joint were dissected, whereas other soft tissues of the shoulder joint were resected, and only the clavicle-coracoclavicular ligament-scapula structures were retained. All the specimens were randomly divided into three groups, with ten specimens in each group. In Group 1, the coracoclavicular ligament was retained; in Group 2, the cone ligament was reconstructed vertically based on the classical Steven technique; and in Group 3, the conical ligament was reconstructed anatomically based on the central site of the original ligament. Biomechanical tests under vertical tensile resistances were conducted separately on the three groups, and the tensile forces that caused the rupture of the coracoclavicular ligament or reconstruction failure were recorded. Results In Group 1, clavicle and coracoid fractures were not found, and the tensile force that caused the coracoclavicular ligament rupture was (650.41 + 35.88) N. In Group 2, clavicle fracture (two cases), endobutton pull-out from the clavicle (two cases) or coracoid (five cases), and coracoid fracture (one case) occurred, and the tensile force that caused the failure of the coracoclavicular reconstruction was (725.68 + 35.37) N. In Group 3, clavicle fracture (three cases ), endobutton pull-out from the clavicle (one case) or coracoid (five cases), and coracoid fracture (one case) occurred, and the tensile force that caused the failure of the coracoclavicular reconstruction was (765.15+13.68) N. Conclusions The tensile forces in the anatomical and vertical reconstruction of the coracoclavicular ligament were both superior to those of the primary ligament, with the anatomical reconstruction being superior to vertical reconstruction under a tensile effect.

13.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1181-1186, 2018.
Article in Chinese | WPRIM | ID: wpr-856700

ABSTRACT

Objective: To investigate the effectiveness of anatomical locking plate internal fixation combined with coracoclavicular ligament reconstruction in treatment of the Neer type Ⅱb distal clavicle fractures by comparing with the simple anatomical locking plate internal fixation. Methods: The clinical data of 40 patients with Neer type Ⅱb distal clavicle fractures who met the criteria between February 2013 and January 2017 were analyzed. Eighteen cases were treated with anatomical locking plate internal fixation and coracoclavicular ligament reconstruction by using a suture anchor (reconstruction group), and 22 cases were treated only with anatomical locking plate internal fixation (non-reconstruction group). There was no significant difference in gender, age, injured side, causes of injury, associated injuries, time from injury to operation between 2 groups ( P>0.05). The operation time, medical expense, postoperative coracoclavicular distance, Constant-Murley scores of injured side, and complications were recorded and compared between 2 groups. Results: All patients were followed up 12-27 months (mean, 16.3 months). One patient in reconstruction group had superficial wound infection. One patient in non-reconstruction group had pullout of screws from the distal fragment and reduction loss at 1 month postoperatively. The operation time and medical expense in reconstruction group significantly increased when compared with those in non-reconstruction group ( P0.05). Conclusion: Both anatomical locking plate internal fixation with and without coracoclavicular ligament reconstruction can achieve good effectiveness for the Neer type Ⅱb distal clavicle fractures. Therefore, the coracoclavicular ligament reconstruction does not need, except for comminuted fractures with the length of lateral fragment less than 1 cm or the patients with poor compliance.

14.
Journal of Regional Anatomy and Operative Surgery ; (6): 526-530, 2017.
Article in Chinese | WPRIM | ID: wpr-613609

ABSTRACT

Objective To investigate the biomechanical characteristics of the acromioclavicular joint,put forward the treatment of acromioclavicular joint dislocation based on the principle of anchor and apply to clinic.Methods From August 2011 to March 2015,24 patients with the acromioclavicular joint dislocation in department of orthopedics of Chinese Medicine Hospital of Changshu were divided into the treatment group and the control group,with 12 cases in each group.The treatment group were treated by vertical suspension buttons steel cable system based on principle of anchor,while the control group were treated by the hook plate technology.The clinical results of the two groups were evaluated by Karlsson score system.Results All the patients were followed up for 6 to 12 months.In terms of the curative effect in the treatment group,there were 11 cases of excellent and 1 case of good,with the excellent and good rate of 100%,and no complication occured.In the control group,there were 7 cases of excellent and 3 case of good,with the excellent and good rate of 83.3%.And there was 1 case of subacromial osteolysis.Conclusion To treat acromioclavicular joint dislocation above Rockwood Ⅲ with vertical suspension buttons steel cable system based on principle of anchor may be an ideal treatment method.

15.
Medical Journal of Chinese People's Liberation Army ; (12): 1088-1091, 2017.
Article in Chinese | WPRIM | ID: wpr-694063

ABSTRACT

Objective To explore the clinical effect of coracoclavicular ligament reconstruction with the autogenous anterior half of peroneus longus tendon (AHPLT) for distal clavicle fracture (Neer type Ⅱ-b).Methods The clinical data were retrospectively analyzed of 26 Neer type Ⅱ-b distal clavicle fracture surgically treated by coracoclavicular ligament reconstruction with autogenous AHPLT in Ganyu District People's Hospital of Lianyungang from June 2012 to May 2015.Among the 26 cases,16 males and 10 females,aged from 19-56 years (average 38.7 years).Fracture occurred in left side in 18 cases and in right side in 8 cases.Postoperative observations were done on fracture healing,shoulder and ankle-foot function recovery.Results For all the 26 cases,surgical incisions were healed well,and no infection,vascular and peroneal nerve injury and iatrogenic fracture occurred.Follow-up was carried out for 10-24 months with average of 15.3 months.All the fractures were healed within 12-20 weeks with an average of 14.6 weeks.One patient was found of losing the fracture reduction part during the follow-up process,and then got eventual healing by extending the limb brake time.Another patient was found of slight tendon sensation disorder with no significant effect on daily life and exercise,and the symptoms disappeared 6 months later.At the last follow-up,the Constant-Murley score was 92-100 with an average of 97.8 points.The ankle-hind foot score of American Society of Ankle and Orthopedics was excellent.Conclusion Reconstruction of coracoclavicular ligament with autogenous AHPLT is an effective treatment for Neer type Ⅱ-b distal clavicle fracture with good safety and without negative effect on the ankle-foot function,and thus it is worthy of wider clinical use.

16.
Clinics in Shoulder and Elbow ; : 230-235, 2017.
Article in English | WPRIM | ID: wpr-75355

ABSTRACT

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. METHODS: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. RESULTS: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. CONCLUSIONS: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.


Subject(s)
Humans , Acromioclavicular Joint , Clavicle , Follow-Up Studies , Methods , Radiography , Shoulder
17.
Journal of the Korean Shoulder and Elbow Society ; : 230-235, 2017.
Article in English | WPRIM | ID: wpr-770818

ABSTRACT

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. METHODS: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. RESULTS: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. CONCLUSIONS: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.


Subject(s)
Humans , Acromioclavicular Joint , Clavicle , Follow-Up Studies , Methods , Radiography , Shoulder
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 532-536, 2016.
Article in Chinese | WPRIM | ID: wpr-856948

ABSTRACT

OBJECTIVE: To compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. METHODS: Thirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A (n=17), and with allogeneic tendon graft combined with hook plate fixation in group B (n=16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation (P>0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. RESULTS: The operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B (P0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups (P>0.05). CONCLUSIONS: Coracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.

19.
Journal of the Korean Fracture Society ; : 127-135, 2014.
Article in Korean | WPRIM | ID: wpr-109011

ABSTRACT

PURPOSE: The purpose of this study is to evaluate the radiologic and clinical outcomes after tension band wire fixation of Neer type II distal clavicle fractures. MATERIALS AND METHODS: Twenty-six patients with Neer type II distal clavicle fractures who underwent tension band wire fixation from March 2002 to May 2011 were included in the study. Fifteen cases were classified as Neer type IIa and 11 cases as type IIb. The postoperative mean follow-up period was 14.3 months. Clinical and radiologic evaluation was performed at two weeks, six weeks, three months, six months, and 12 months postoperatively. RESULTS: Bony union on X-rays was observed at an average of 11.7 weeks (range 8-20 weeks) postoperatively. The overall visual analogue scale score for pain was 1.23+/-2.75 postoperatively. The overall postoperative University of California at Los Angeles score increased to 33.5+/-2.15 from the preoperative score of 21.6+/-1.91 (p<0.05). CONCLUSION: Among various methods of treatment for Neer type II distal clavicle fracture, K-wire and tension band fixation was used and relatively satisfactory radiological and clinical results were obtained. This surgical method yields excellent clinical results, owing to its relatively easy technique, fewer complications, and allowance of early rehabilitation.


Subject(s)
Humans , California , Clavicle , Follow-Up Studies , Rehabilitation
20.
The Journal of Practical Medicine ; (24): 1578-1580, 2014.
Article in Chinese | WPRIM | ID: wpr-451455

ABSTRACT

Objective To compare the effects of application of clavicular hook plate combined with wire anchors anatomical coracoclavicular ligament reconstruction and application of clavicular hook plate in the treatment of NeerII distal clavicle fracture and Tossy Ⅲtype~V acromioclavicular joint dislocation. Methods A retrospective analysis of the clinical data from June 2006 to June 2013. Total 73 cases patients suffered with Neer Ⅱtype distal clavicle fractures and Tossy Ⅲtype~V acromioclavicular joint dislocation. Of which , 41 cases were subjected to treatment with clavicular hook plate , 32 patients subjected to treatment of using clavicular hook plate combined with anchors .The incision length, operative time, postoperative complications, length of hospital stay and postoperative 1 month, 6 month shoulder VAS score of two groups were analyzed; the shoulder function of both groups after 1 month, 6 months were assessed by using Constant shoulder function assessment method. Results Surgical incision length and operational time between the two groups were statistically significant (P<0.05), while the amount of bleeding was not statistically significant. All patients were followed up . The two groups did not occur any complications such as loosening, decoupling, acromioclavicular joint dislocation and wound infections. Hospitalization time was 5~14 d (averaged 10d), no significant difference between two groups. 4 the shoulder Constant score and VAS scores showed no significant difference 1 months postoperation; 6 months after hook plate removed, VAS score and Constant shoulder score improved significantly in anchors hook plate group (P<0.05). Conclusion Anatomical coracoclavicular ligament reconstruction by application of hook plate combined with anchors is a good biomechanical model characterized with simple surgery , less trauma and good clinical outcomes , worthy of clinical application.

SELECTION OF CITATIONS
SEARCH DETAIL