RGO (Porto Alegre) ; 65(4): 380-385, Oct.-Dec. 2017. graf
Article in English | LILACS, BBO | ID: biblio-896043

ABSTRACT

ABSTRACT The rehabilitation treatment of patients with cleft lip and palate is lengthy and is carried out by various professionals from different areas of healthcare.To this end, planning and specialist knowledge are critical to the success of the treatment, in this way envisioning the aesthetic and functional rehabilitation of the individual in order to integrate them into society. This study consists of a literature review along with the report of a clinical case, demonstrating the treatment performed with the use of a removable partial denture using the abutment teeth treated with milled metal-ceramic crowns and the use of attachments, with a view to promoting the retention and stability of the prosthetic device. With the use of this system as a whole, aimed at improving the facial proportions due to the restoration of vertical dimension of occlusion and adequate lip support, features that are often not present in individuals with cleft lip and palate. In this work, we are seeking to underline the importance of scientific and technical knowledge, combined with a well-executed planning, in order to achieve successful treatment that restores function and aesthetics to the patient, thereby enabling their reintegration into society.


RESUMO O tratamento reabilitador de um paciente com fissura labiopalatina envolve um longo período e efetuado por diversos profissionais de diferentes áreas da saúde. Para tal, o planejamento e o conhecimento específico são de suma importância para o sucesso do tratamento, vislumbrando, dessa forma, a reabilitação estética e funcional do indivíduo de forma a integrá-lo na sociedade. O presente trabalho consiste em relato de um caso clínico, demonstrando o tratamento efetuado com a utilização de prótese parcial removível utilizando os dentes pilares tratados com coroas metalo-cerâmicas fresadas e a utilização de encaixes, com intuito de favorecer a retenção e estabilidade do aparelho protético. Com o uso de todo esse sistema objetivando a melhoria nas proporções faciais devido à devolução da dimensão vertical de oclusão e suporte labial adequado, características que muitas vezes não estão presentes nos indivíduos com fissuras labiopalatinas. Este trabalho tem o intuito de ressaltar a importância do conhecimento científico e técnico, somados a planejamento bem realizado a fim de se conseguir o sucesso do tratamento, devolvendo função e estética do paciente, reintegrando-o a sociedade.

2.
Bauru; s.n; 2017. 64 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880038

ABSTRACT

As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação.(AU)


Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.(AU)


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Crowns , Dental Restoration Failure , Denture, Partial, Fixed , Metal Ceramic Alloys/therapeutic use , Tooth Fractures/etiology , Reference Values , Retrospective Studies , Surveys and Questionnaires , Time Factors , Treatment Outcome
3.
Bauru; s.n; 2016. 72 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-882154

ABSTRACT

Fraturas completas ou por delaminação são causas frequentes de insucesso entre coroas unitárias cerâmicas. O uso de materiais à base de resina composta, em contraponto à natureza friável das cerâmicas, parece ser uma alternativa para coroas posteriores, uma vez que apresentam processo de fabricação e reparo simplificados. Este estudo avalia a resistência à fadiga de coroas unitárias monolíticas CAD/CAM de resina composta nanocerâmica e cerâmica reforçada por dissilicato de lítio, bem como os danos causados pela aplicação de carga cíclica. Vinte e seis coroas monolíticas (n=13) foram cimentadas sobre réplicas de resina composta de um molar preparado e submetidas à ciclagem mecânica durante 2 milhões de ciclos, sob carga máxima de 350N à frequência de 2 Hz. Não foram observadas fraturas catastróficas ou fratura coesiva das coroas, resultando em sobrevivência de 100% para os dois materiais avaliados. As coroas foram incluídas em resina epóxi e desgastadas progressivamente à procura de danos. Coroas em resina nanocerâmica apresentaram-se íntegras, com trincas do cone externo, trincas do cone interno e com trincas radiais. As coroas em dissilicato de lítio apresentaram trincas do cone externo e interno, algumas atingindo a superfície interna. Os danos receberam escores de acordo com a severidade. Os dados foram submetidos à análise estatística pelo teste de Mann-Whitney (p =0,462), que não revelou diferenças estatísticas em relação aos danos observados. Concluímos que coroas monolíticas em dissilicato de lítio e resina nanocerâmica podem ser utilizadas na região posterior, pois apresentaram resistência à fadiga equivalente, sem diferença estatística entre os danos apresentados.(AU)


Bulk fractures or cohesive fractures are frequent complications for ceramic crowns. The use of resin- based materials, in contrast to the brittle nature of ceramics, seems to be an alternative to posterior crowns, since these materials present simplified manufacturing and repair tehniques. This study evaluates the fatigue resistance of monolithic CAD / CAM crowns made of resin nanoceramic and lithium disilicate reinforced ceramic, as well as the damage modes caused by the application of cyclic loading. Twenty-six monolithic crowns (n = 13) were cemented to a composite resin replica of a prepared molar and subjected to cyclic load over 2 million cycles under maximum load of 350N, at a frequency of 2 Hz. The crowns presented no catastrophic failures or cohesive fractures, resulting in survival of 100% for both materials. The crowns were embedded in epoxy resin and gradually grinded for damage analisys. Nanoceramic resin crowns presented no damage, outer cone cracks, inner cone cracks and radial cracks. Lithium disilicate crowns showed outer and inner cone cracks, some of the latter reaching the inner surface. Specimens were scored according to the severity of damage. Data was subjected to Mann-Whitney test (p = 0.462), which revealed no statistical difference. We conclude that lithium disilicate and resin nanoceramic monolithic crowns can be used in the posterior area, since they presented comparable fatigue resistance, with no statistical difference between damage modes.(AU)


Subject(s)
Composite Resins/chemistry , Computer-Aided Design , Crowns/standards , Dental Porcelain/chemistry , Tooth Fractures , Dental Restoration Failure , Materials Testing , Reference Values , Reproducibility of Results , Statistics, Nonparametric , Stress, Mechanical
4.
Bauru; s.n; 2015. 181 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867345

ABSTRACT

As cerâmicas à base de dissilicato de lítio apresentam propriedades mecânicas, resistência química, biocompatibilidade, baixo índice de acúmulo de placa e resultados estéticos favoráveis. Entretanto, sua resistência à fadiga e probabilidade de sobrevida (confiabilidade) em sua forma estratificada e monolítica ainda é pouco conhecida. Este estudo tem como objetivo investigar a confiabilidade e o modo de falha das coroas estratificadas de dissilicato de lítio com e sem modificação do desenho da infraestrutura e de coroas monolíticas quando submetidas ao ensaio de fadiga por intermédio da ciclagem dinâmica em água. Trinta coroas foram divididas em 3 grupos: IEC (coroas estratificadas com infraestrutura convencional), IEM (coroas estratificadas com infraestrutura modificada) e MON (coroas monolíticas). Para os grupos IEC e IEM as infraestruturas apresentavam espessura de 0,8 mm. No entanto, no desenho modificado era adicionado uma cinta lingual de 2 mm de altura conectada a postes proximais de 3,5 mm de altura, ambos com 1,3 mm de espessura. As MON eram compostas inteiramente de dissilicato de lítio e apresentavam espessura oclusal de 1,5 mm. As coroas foram cimentadas em troqueis de resina composta e submetidas a ciclagem dinâmica em água (30-300 N). Um endentador monolítico de dissilicato de lítio aplicava carga axial sobre a crista marginal mesial até a fratura, e posteriormente na crista distal. Ao final, as coroas eram analisadas em estereomicroscópio e no microscópico eletrônica de varredura (MEV) para caracterização e classificação dos danos. As falhas encontradas nas coroas foram registradas a cada 125.000 ciclos. A distribuição Weibull a 2 parâmetros (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) foi utilizada para calculo da probabilidade de sobrevida em 1, 2 e 3 milhões de ciclos. Comparações entre os grupos também foram realizadas com o módulo de Weibull e a resistência característica (número de ciclos decorrido até a fratura). Tanto em 1...


Lithium disilicate glass-ceramic provides desirable mechanical properties, chemical resistance, biocompatibility, diminished plaque accumulation, esthetics, and favorable esthetic results. However, the fatigue life and probability of survival (reliability) of lithium disilicate in its monolithic or layered form is still poorly understood. This study aimed to investigate the reliability and failure modes of porcelain veneered lithium disilicate crowns with and without core design modification, and of monolithic crowns when subjected to cyclic fatigue in water. Thirty lithium disilicate molars crowns were made and divided into 3 groups: IEC (bilayer crown with even thickness coping, i.e. conventional core), IEM (bilayer crowns with modified core design) and MON (monolithic crowns). For groups IEC and IEM, copings presented an even thickness of 0.8 mm and the modified design consisted of 1.3 mm thickness with a lingual margin of 2.0mm height connected to full contour proximal struts of 3.5 mm height. Monolithic crowns had an occlusal thickness of 1.5 mm. Crows were luted on composite resin abutment replicas and subjected to cyclic fatigue in water (30-300 N). A monolithic indenter of lithium disilicate was used to deliver the load on the mesial marginal ridge until failure, then the same procedure was performed in the distal ridge. For failure characterization crowns were analyzed in stereomicroscope and scanning electron microscope (SEM). Failure inspection was performed every 125,000 cycles. The 2-parameter Weibull distribution (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) was used calculate the probability of survival at 1, 2, and 3 million cycles. Comparisons between groups were also made for Weibull modulus and characteristic strength (number of cycles elapsed until failure). At both 1 and 2 million cycles, reliability was significantly lower for IEM relative to MON and IEC showed no difference between the IEM and MON. At 3 million cycles, only...


Subject(s)
Crowns , Dental Restoration Failure , Lithium/chemistry , Dental Porcelain/chemistry , Dental Prosthesis Design , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Stress, Mechanical , Tooth Fractures
5.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867423

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
6.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-794217

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Humans , Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
7.
Bauru; s.n; 2015. 181 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-773800

ABSTRACT

As cerâmicas à base de dissilicato de lítio apresentam propriedades mecânicas, resistência química, biocompatibilidade, baixo índice de acúmulo de placa e resultados estéticos favoráveis. Entretanto, sua resistência à fadiga e probabilidade de sobrevida (confiabilidade) em sua forma estratificada e monolítica ainda é pouco conhecida. Este estudo tem como objetivo investigar a confiabilidade e o modo de falha das coroas estratificadas de dissilicato de lítio com e sem modificação do desenho da infraestrutura e de coroas monolíticas quando submetidas ao ensaio de fadiga por intermédio da ciclagem dinâmica em água. Trinta coroas foram divididas em 3 grupos: IEC (coroas estratificadas com infraestrutura convencional), IEM (coroas estratificadas com infraestrutura modificada) e MON (coroas monolíticas). Para os grupos IEC e IEM as infraestruturas apresentavam espessura de 0,8 mm. No entanto, no desenho modificado era adicionado uma cinta lingual de 2 mm de altura conectada a postes proximais de 3,5 mm de altura, ambos com 1,3 mm de espessura. As MON eram compostas inteiramente de dissilicato de lítio e apresentavam espessura oclusal de 1,5 mm. As coroas foram cimentadas em troqueis de resina composta e submetidas a ciclagem dinâmica em água (30-300 N). Um endentador monolítico de dissilicato de lítio aplicava carga axial sobre a crista marginal mesial até a fratura, e posteriormente na crista distal. Ao final, as coroas eram analisadas em estereomicroscópio e no microscópico eletrônica de varredura (MEV) para caracterização e classificação dos danos. As falhas encontradas nas coroas foram registradas a cada 125.000 ciclos. A distribuição Weibull a 2 parâmetros (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) foi utilizada para calculo da probabilidade de sobrevida em 1, 2 e 3 milhões de ciclos. Comparações entre os grupos também foram realizadas com o módulo de Weibull e a resistência característica (número de ciclos decorrido até a fratura)...


Lithium disilicate glass-ceramic provides desirable mechanical properties, chemical resistance, biocompatibility, diminished plaque accumulation, esthetics, and favorable esthetic results. However, the fatigue life and probability of survival (reliability) of lithium disilicate in its monolithic or layered form is still poorly understood. This study aimed to investigate the reliability and failure modes of porcelain veneered lithium disilicate crowns with and without core design modification, and of monolithic crowns when subjected to cyclic fatigue in water. Thirty lithium disilicate molars crowns were made and divided into 3 groups: IEC (bilayer crown with even thickness coping, i.e. conventional core), IEM (bilayer crowns with modified core design) and MON (monolithic crowns). For groups IEC and IEM, copings presented an even thickness of 0.8 mm and the modified design consisted of 1.3 mm thickness with a lingual margin of 2.0mm height connected to full contour proximal struts of 3.5 mm height. Monolithic crowns had an occlusal thickness of 1.5 mm. Crows were luted on composite resin abutment replicas and subjected to cyclic fatigue in water (30-300 N). A monolithic indenter of lithium disilicate was used to deliver the load on the mesial marginal ridge until failure, then the same procedure was performed in the distal ridge. For failure characterization crowns were analyzed in stereomicroscope and scanning electron microscope (SEM). Failure inspection was performed every 125,000 cycles. The 2-parameter Weibull distribution (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) was used calculate the probability of survival at 1, 2, and 3 million cycles. Comparisons between groups were also made for Weibull modulus and characteristic strength (number of cycles elapsed until failure). At both 1 and 2 million cycles, reliability was significantly lower for IEM relative to MON and IEC showed no difference between the IEM and MON. At 3 million cycles...


Subject(s)
Crowns , Dental Restoration Failure , Lithium/chemistry , Dental Porcelain/chemistry , Dental Prosthesis Design , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Stress, Mechanical , Tooth Fractures
8.
Braz. dent. sci ; 16(2): 44-50, 2013. ilus, tab
Article in English | LILACS, BBO | ID: lil-698289

ABSTRACT

Objective: This study aimed at evaluating the micro-hardness of an acrylic resin used for provisional crowns. Materials and methods: Five different processing techniques (direct and indirect) were assessed: (I) auto polymerizing resin in sandy stage; (II) auto polymerizing resin in plastic stage; (III) bead-brush technique; (IV) auto polymerizing resin under pressure; (V) heatcured acrylic resin under pressure. Five specimens were made for each test group. For the initial micro-hardness test, the specimens were immersed in deionized water for 48 hours. For the analysis of the final micro-hardness, the specimens were subjected to pH-cycling to simulate the changes in the pH level which occur in the oral cavity. Results: Tests revealed that the micro-hardness was decreased after the pH-cycling. However, no statistical difference was found among the different types of acrylic resin polymerization techniques. Conclusion: It was concluded that the micro-hardness is not directly related to the polymerization technique for making provisional


Objetivo: Avaliou-se a dureza superficial de uma resina acrílica (PMMA) utilizada para a confecção de coroas provisórias. Material e Métodos: Cinco diferentes técnicas de processamento (Direta e Indireta) para polimerização da resina foram testadas: I - autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de silicona na fase arenosa; II - autopolimerização após mistura em pote dappen com inserção em matriz de silicona na fase plástica; III - autopolimerização utilizando a técnica do pincel; IV - autopolimerização sob pressão em matriz de silicona; V - polimerização térmica utilizando líquido de polimerização rápida em mufla. Foram confeccionados cinco corpos-de-prova para cada grupo. Para o teste de microdureza inicial os espécimes foram imersos em água deionizada por 48 horas. Para a análise da dureza final, os espécimes foram submetidos a ciclos dinâmicos de pH, para simular a variação de pH ocorrida na cavidade oral. Resultados: Os testes revelaram que houve diminuição da dureza do material após a ciclagem ácida, porém não foi verificada diferença estatística entre os diferentes tipos de processamento da resina acrílica. Conclusão: Concluiu-se que a microdureza não está relacionada diretamente com a técnica de confecção dos provisórios.


Subject(s)
Acrylic Resins , Crowns , Dental Prosthesis , Denture, Partial, Temporary
9.
J. Health Sci. Inst ; 28(3): 246-248, july-sept. 2010. ilus
Article in English | LILACS | ID: lil-606285

ABSTRACT

Amelogenesis imperfecta (AI) is an inherited disorder which results in enamel defects. The main clinical characteristics are extensive loss of tooth tissue, poor esthetics and tooth sensitivity. Early recognition followed by appropriate preventive care and oral rehabilitation is essential in the successful management of AI. This clinical report describes the management of a 3 year-old girl with a hypocalcified type of Al. The patient presented early extensive tissue loss of the superior incisors and molars, with general dentinal sensitivity. The first phase of the treatment was preventive measures to improve dental and periodontal health. On the second phase the anterior teeth were extracted and the molars were endodontic treated and covered with stainless steel crowns. A functional appliance was made to rehabilitate the anterior extracted teeth on the third phase. The performed treatment achieved satisfactory esthetic and function, which resulted in an improvement in the child's quality of life.


Amelogênese imperfeita (AI) é uma doença hereditária que resulta em defeitos no esmalte. As principais características clínicas são a extensa perda de tecido dentário, estética prejudicada devido a coloração acastanhada dos dentes e sensibilidade dentária. O reconhecimento precoce seguido de cuidados preventivos adequados e reabilitação oral é essencial para o êxito nos tratamentos de AI. Este relato de caso clínico descreve o tratamento de uma criança de 3 anos com Al do tipo hipocalcificada. A paciente apresentava inicialmente extensas perdas de tecido nos incisivos superiores e molares, e uma sensibilidade dentinária generalizada. O tratamento reabilitador foi dividido em duas fases, na primeira fase do tratamento foram passadas à mãe e a criança medidas preventivas para melhorar a saúde dental e periodontal. Na segunda fase do tratamento os dentes anteriores foram extraídos e os molares foram tratados endodonticamente e cobertos com coroas de aço. Um aparelho funcional, visando manter o espaço dentário e oferecer uma estética de sorriso à paciente foi feito para reabilitar o arco anterior devido as extrações dentárias. O tratamento realizado foi satisfatório tanto na estética quanto na função, o que resultou em uma melhora na qualidade de vida da criança.

10.
Rev. Fac. Odontol. Porto Alegre ; 51(2): 31-38, maio-ago. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-719562

ABSTRACT

A evolução constante das técnicas operatórias e dos materiais restauradores tem permitido avanços impressionantes nas reconstruções dentárias, permitindo que dentes tratados endodonticamente com amplas destruições coronárias seja reconstruídos em sessão única. A aplicabilidade clínica das resinas compostas, principalmente em dentes posteriores, vem sendo bastante aceitada pelos profissionais e pacientes devido à questão estética e à resistência que os materiais resinosos desenvolveram nesses últimos 20 anos. Já para os profissionais, seguir o correto protocolo clínico é fundamental para aperfeiçoar a estética e a longevidade da restauração. Este trabalho tem como objetivo, através do relato de casos clínicos, descrever técnicas para restauração de dentes anteriores e posteriores amplamente destruídos utilizando resinas compostas na confecção de coroas totais diretas associadas a pinos de fibra de vidro pré-fabricados. Os casos aqui relatados constituem-se num procedimento alternativo, de baixo custo, e rápida elaboração, que conseguiu suprir as necessidades do paciente, mostrando ser uma boa opção de tratamento reabilitador.


The constant evolution of surgical techniques and restorative materials has allowed impressive advances in dental reconstructions, allowing endodontically treated teeth with extensive coronary destruction to be reconstructed in a single session. The clinical application of composite resins, especially in posterior teeth has been widely accepted by professionals and patients due to the aesthetic issue and the resistance that the resin materials developed in the last 20 years. As for professionals, following the correct protocol is essential to improve the aesthetics and longevity of the restoration. This paper aims, through clinical case reports, to describe techniques for restoring largely destroyed anterior and posterior teeth using composite resins to build up crowns attached to direct fiberglass prefabricated pins. The cases reported here are an alternative procedure, low cost and rapid development, which could meet the needs of the patient, being a good choice of dental oral rehabilitation.


Subject(s)
Humans , Female , Middle Aged , Composite Resins , Crowns , Dental Restoration, Permanent
11.
Rev. bras. odontol ; 62(3/4): 187-192, 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-541739

ABSTRACT

Este estudo teve como finalidade analisar a influência da esplintagem de restaurações protéticas fixas na distribuição das tensões de von Mises em dois modelos matemáticos bidimensionais obtidos pelo método de elementos finitos. O limite de proporcionalidade dos materiais e estruturas analisadas não foi alcançado nos dois modelos, de modo que nenhuma das configurações estudadas foi contra-indicada. Entretanto, os resultados sugeriram que o planejamento do tratamento deve ser adequado a condições anatômicas oclusais e biomecânicas específicas.


Subject(s)
Finite Element Analysis , Biomechanical Phenomena , Crowns , Dental Implants