Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article | IMSEAR | ID: sea-206699

ABSTRACT

Background: Intrauterine contraceptive device is a long acting, effective and reversible method of contraception. It can be inserted post placental during vaginal or LSCS delivery and within 48 hours of delivery.  This study evaluates the acceptance, safety, side effects and complications associated with immediate post-partum intrauterine contraceptive device (PPIUCD) insertion.Methods: The study was conducted at Hindu Rao Hospital and NDMC Medical College, Delhi for a period of 18 months. Patients admitted and delivered at Hindu Rao Hospital were counseled for PPIUCD, CuT 380 A / CuT 375 insertions and it was inserted within 10 minutes of delivery of placenta during vaginal delivery or LSCS or within 48 hours of delivery. Patients were followed at 6 weeks and then between 6 to 12 months of delivery for continuation, side effects or any complications.Results: After counseling 1253 (9.8%) patients agreed for PPIUCD insertion out of which 650 patients came for follow up. 46% women came for routine follow up while 54.06% came with one or the other complications. Missed thread was most common complications, followed by bleeding P/V and pain abdomen. Expulsion in 5.5% and CuT failure was seen in 0.92% women only. Removal of IUCD was done in 94 patients for one or other reasons. There was retention of PPIUCD in 84.5% while removal was done in 14.5% during period of 6 months to one year follow up. Missed thread was main cause of anxiety among acceptors.Conclusions: Immediate PPIUCD is safe and effective method of contraception with a high retention rate. Though acceptance in initial months was less but it gradually increased over time with increasing awareness, counseling of patients and training of health personnel.

2.
Indian J Physiol Pharmacol ; 2008 Jul-Sept; 52(3): 267-273
Article in English | IMSEAR | ID: sea-145877

ABSTRACT

Release of copper and its effect on functional integrity of human sperms in vitro were assessed following co-incubation of semen with CuT 380A. After 30 min of incubation with semen, release of copper ions from CuT 380A was found to be 9.2 to 40 times higher compared to control incubations with PBS. Sperm function tests, when simultaneously performed following loss of motility in sperms (>95%) after 120 min of copper exposure, depicted a significant (P<0.001) reduction in sperm viability and hypo-osmotic swelling (HOS) response. However, the affected sperm populations revealed no significant alterations in other functional tests like acrosomal status or nuclear chromatin decondensation. It is therefore concluded that the high release of copper from CuT 380A drastically lowers sperm motility. viability and HOS response but only marginally affects the acrosome status or nuclear chromatin condensation in short term incubations.

SELECTION OF CITATIONS
SEARCH DETAIL