1.
Odontol.sanmarquina (Impr.) ; 26(3): e25460, jul.-set.2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1538052

ABSTRACT

Objetivo. Comparar la dureza, estabilidad dimensional y resistencia a la compresión de los yesos dentales de alta resistencia y baja expansión disponibles en el Perú. Métodos. Se realizó un estudio descriptivo, observacional y transversal. Se confeccionaron muestras de forma cilíndrica (8) y rectangular (8), de siete yesos dentales de alta resistencia y baja expansión. Se evaluó la dureza utilizando el Durómetro Universal Identec, la estabilidad dimensional con un calibrador digital y la resistencia a compresión con la Máquina de Ensayo Universal. Para determinar si hay diferencia en cada una de estas propiedades se empleó el análisis de varianza, la prueba F y la prueba de Duncan. Además, se empleó la prueba de comparación de medias, t de Student, para evaluar si difieren con los valores de la ADA (Asociación Dental Americana). Resultados. La dureza, estabilidad dimen-sional y resistencia a la compresión promedio de los yesos dentales presentó diferencias significativas (p<0.05) entre cada uno con los promedios estándares establecidos por la ADA. Conclusiones. En relación resistencia a la compresión el 100% de los yesos analizados cumplen con los parámetros establecidos por la ADA, en relación estabilidad dimensional solo el 28.6% y el 100% no alcanzan los estándares de dureza promedio establecidos por la ADA.


Objective. To compare the hardness, dimensional stability, and compressive strength of high-strength, low-expansion dental plasters available in Peru, according to ADA criteria. Methods. A descriptive, observational and cross-sectional study was developed. A selection of 8 cylindrical-shaped samples and 8 rectangular- shaped ones, from seven high-resistance, low-expansion dental plasters were fabricated. The hardness was evaluated using the Identec Universal Durometer. Dimensional stability was evaluated with a digital caliper and compressive strength was evaluated with the Instron Universal Testing Machine. To determine if there is a difference in each of these properties, the analysis of variance, F test, and the Duncan's test were used. In addition, to assess whether these values differ from those of the ADA, the mean comparison test, student's t table, were used. Results. The hardness, dimensional stability and average compressive strength of the high-strength, low-expansion dental plasters showed that there are significant di-fferences (p<0.05) between each of the dental plasters and with the standard averages established by the American Dental Association. (ADA). Conclusions. 100% of the high-strength, low-expansion dental casts meet the parameters established by the ADA in terms of their compressive strength, only 28.6% of these comply with the ADA in terms of dimensional stability and that 100% of these do not meet the average hardness standards established by the ADA.

2.
The Journal of Advanced Prosthodontics ; : 8-17, 2018.
Article in English | WPRIM | ID: wpr-742015

ABSTRACT

PURPOSE: The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS: A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (α=.05). RESULTS: In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to 20.88 µm), of which the marginal and internal variations ranged 51.36 – 58.26 µm and 18.33 – 20.04 µm, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than 5 µm, of which blue color group was the smallest (3.27 ± 0.24 µm) and white color group was the largest (4.24 ± 0.36 µm). These results were consistent with the DS data. CONCLUSION: The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.


Subject(s)
Calcium Sulfate , Dataset , Hand , Molar , Silicon , Silicones , Titanium , Tooth Preparation , Tooth
3.
Rev. clín. pesq. odontol. (Impr.) ; 5(3): 255-261, set.-dez. 2009. tab
Article in Portuguese | LILACS, BBO | ID: lil-617424

ABSTRACT

OBJETIVO: O objetivo deste estudo foi avaliar e comparar in vitro propriedades fisicas e mecanicas (resistencias a compressao e a tracao diametral, tempo de presa, fidelidade de copia e dureza) de gessos comerciais, cujas composicoes foram alteradas. MATERIAL E METODO: Foram confeccionados 40 corpos-de-prova para cada tipo de gesso e submetidos aos testes citados (n=10). Os corpos-de-prova obtidos para verificacao da resistencia a tracao foram antes submetidos a analise de dureza. Os tempos de presa foram analisados imediatamente apos a manipulacao dos materiais e os demais ensaios propostos foram realizados apos 7 dias da obtencao das amostras. RESULTADOS: Os valores obtidos nos testes foram analisados estatisticamente (1-way ANOVA, Tukey, p<0.05); observou-se que Exp1 apresentou melhor reproducao de detalhes e Exp2 o menor tempo de presa em relacao aos materiais comerciais (p<0.05). Nas demais propriedades, os gessos experimentais apresentaram comportamentos semelhantes aos comerciais. CONCLUSOES: Concluiu-se que as alteracoes na composicao dos gessos contribuiram para a melhoria na reproducao de detalhes no grupo Exp1, e diminuicao no tempo de presa no grupo Exp2.


OBJECTIVE: The purpose of this study was to evaluate and to compare in vitro mechanical and physical properties (compression and diametral tensile strength, setting time, loyalty to copy and hardness) of commercial and experimental gypsums (Exp1 and Exp2), whose compositions were altered. MATERIAL AND METHOD: Forty specimens were obtained for each type of gypsum (n=10). The specimens obtained to verify tensile strength were submitted to hardness analysis before. The setting time were analysed immediately after the manipulation of materials and the other tests were conducted 7 days after the specimens were obtained. RESULTS: The values were analyzed statistically (1-way ANOVA, Tukey, p <0.05) and it was observed that Exp1 showed better reproduction of details and Exp2 presented lesser setting time than commercial materials (p <0.05). As regards to other properties, experimental gypsums showed similar behavior to commercial gypsums. CONCLUSION: It was concluded that alterations in gypsum composition contributed to the improvement in reproduction of details in Exp1 group, and promoted a decrease in setting time in Exp2.


Subject(s)
Dental Impression Materials/chemistry , Calcium Sulfate/chemistry , Hardness , Materials Testing , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors