Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Article in Portuguese | LILACS | ID: biblio-882606

ABSTRACT

O descolamento de retina é definido como a separação da retina sensorial do epitélio pigmentar da retina pela presença de fluído sub-retiniano. Esse artigo é uma revisão sobre suas principais formas, diagnóstico, tratamento e prevenção.


A retinal detachment is a separation of the sensory retina from the retinal pigment epithelium by subretinal fluid. This article is a review about the different types of retinal detachment, diagnoses, treatment and prevention.


Subject(s)
Retinal Detachment , Vitreous Detachment
2.
Arq. bras. oftalmol ; 75(6): 415-419, nov.-dez. 2012. ilus, tab
Article in English | LILACS | ID: lil-675625

ABSTRACT

PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH). METHODS: 29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT. RESULTS: OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes) and II (1 eye), both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD) were highlighted. In stages III (14 eyes) and IV (5 eyes), both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression. CONCLUSION: 10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.


OBJETIVO: A tomografia de coerência óptica (OCT) é um método diagnóstico valioso para estudo da mácula. Entretanto, por se basear na energia luminosa, não pode ser realizada quando existe opacidade de meios. Nesses casos, o ultrassom (US) pode predizer algumas características maculares. Este estudo teve como objetivos caracterizar imagens obtidas por US com transdutores de 10 e 20-MHz comparadas ao OCT, assim como analisar a relação vitreorretiniana em olhos com buraco macular (BM). MÉTODOS: Vinte e nove olhos de 22 pacientes com evidência biomicroscópica de BM em diferentes estágios foram incluídos. Todos os pacientes foram avaliados com ultrassonografia utilizando transdutores de 10 e 20-MHz e OCT de domínio espectral. RESULTADOS: OCT diagnosticou BM em 25 dentre 29 olhos estudados. Os 4 casos não identificados por US eram pseudoburacos decorrentes de membrana epirretiniana. Nos BM estágios I (2 olhos) e II (1 olho), ambos transdutores não foram úteis para analisar o espessamento macular, mas foram identificados sinais sugestivos como irregularidade macular, opérculo ou descolamento parcial do vítreo posterior (DVP). Nos estágios III (14 olhos) e IV (5 olhos), ambos transdutores identificaram irregularidade, dupla corcova e espessamento macular. O US foi capaz de medir a espessura macular e identificar outros indícios de BM, como opérculo, tração vitreorretiniana e DVP. Em pseudoburacos, o US identificou irregularidades no contorno macular e discreta depressão. CONCLUSÃO: US de 10-MHz foi útil para uma avaliação global do corpo vítreo e sua relação à retina. O US de 20-MHz forneceu informações importantes sobre a junção vitreorretiniana e contorno macular. OCT fornece qualidade superior para estudo morfológico da região macular, exceto em casos de opacidade de meios. Nesses casos, ou quando o exame tomográfico não for disponível, o estudo ultrassonográfico de 10 e 20-MHz é capaz de proporcionar análise válida da região macular e auxiliar na abordagem terapêutica.


Subject(s)
Aged , Child , Female , Humans , Male , Middle Aged , Retina , Retinal Perforations , Tomography, Optical Coherence/methods , Vitreous Body , Vitreous Detachment , Macula Lutea , Microscopy, Acoustic , Retinal Perforations/pathology , Transducers , Vitreous Body/pathology , Vitreous Detachment/pathology
3.
Rev. bras. oftalmol ; 67(2): 97-99, mar.-abr. 2008. ilus
Article in Portuguese | LILACS | ID: lil-484540

ABSTRACT

Atualmente, uma avaliação mais apurada da interface vítreo-retiniana tem sido propiciada pela utilização da tomografia de coerência óptica, criada em 1995. Este tipo de imagem tecnológica tem possibilitado um melhor entendimento das alterações involucionais e patológicas que acometem a interface vítreo-retiniana. Os métodos semiológicos até então disponíveis (biomicroscopia, lentes fundoscópicas e ultrassonografia) eram limitados em suas resoluções e formulações de conceitos etiopatogênicos relacionados com modificações desta interface vítreo-retiniana. Este artigo faz breves considerações sobre tais métodos semiológicos e enfatiza a importância da tomografia de coerência óptica na avaliação da interface vítreo-retiniana.


Assessment of the vitreoretinal interface has been greatly aided by the development of optical coherence tomography, in 1995. This imaging technology has allowed us to study involutional and disease processes that were previously unrecognizable by biomicroscopy and ultrasonography alone.This article will review these studies and illustrate the usefulness of optical coherence tomography in the evaluation of the vitreoretinal interface.

4.
Arq. bras. oftalmol ; 70(5): 839-843, set.-out. 2007. tab
Article in English | LILACS | ID: lil-470103

ABSTRACT

PURPOSE: Flashes of light and floaters are most commonly caused by posterior vitreous separation but may be associated with sight-threatening disorders. Prevention of severe sequelae requires prompt dilated eye examination. Thus, information dissemination is crucial. This study aimed to evaluate the quality of information about floaters and light flashes available for patients on the Internet. METHODS: Cross-sectional study. In July 2005 we evaluated information available on the Internet regarding floaters and light flashes, using two search engines (MetaCrawler and MSN) and three key terms ("floaters", "dark spots eye", and "light flashes eye"). The quality of each website was evaluated using a score system. The sites were classified as academic, organizational or commercial. Readability, general quality of the website (based on: ownership, purpose, authorship, author qualification, attribution, interactivity, and currency) and quality of the specific content (definition, causes, epidemiology, diagnosis, treatment, and prognosis) were analyzed. RESULTS: Of 145 websites evaluated, 49 were included. Four sites (8.2 percent) were academic, 9 (18.4 percent) organizational, and 36 (73.4 percent) commercial. In the majority of the sites (53.0 percent) information was poor and quality was not correlated with website classification. CONCLUSIONS: Information about floaters and light flashes available on the Internet is poor.


OBJETIVOS: Fotopsias e miopsias são geralmente causadas pelo descolamento do vítreo posterior, mas podem estar associadas a doenças oculares. A prevenção de seqüelas importantes requer o exame rápido e apropriado do paciente. Portanto, o conhecimento pelo paciente é crucial. Este estudo objetivou avaliar a qualidade da informação sobre miopsias e fotopsias disponíveis para acesso dos pacientes na Internet. MÉTODOS: Estudo de corte transversal. Em julho de 2005, avaliamos as informações disponíveis na Internet sobre miopsias e fotopsias, usando duas ferramentas de busca (MSN e MetaCrawler) e três palavras-chave ("floaters", "dark spots eye", "light flashes eye"). A qualidade de cada site foi avaliada por uma escala de pontos. Os sites foram classificados como acadêmicos, organizacionais ou comerciais. Avaliamos a confiabilidade, a qualidade do site (baseada no autor, propósito, qualificação do autor, interatividade, atualizações) e qualidade do conteúdo (definição, causas, epidemiologia, diagnóstico, tratamento e prognóstico). RESULTADOS: Dos 145 sites avaliados, 49 foram incluídos no estudo. Quatro sites (8,2 por cento) foram acadêmicos, 9 (18,4 por cento) organizacionais e 36 (73,4 por cento) foram comerciais. Em sua grande maioria (53 por cento), as informações contidas nos sites foram consideradas como pobres e a qualidade não estava correlacionada com a classificação do site. CONCLUSÃO: As informações disponíveis na Internet sobre miopsias e fotopsias são insuficientes.


Subject(s)
Humans , Eye Diseases , Internet/standards , Patient Education as Topic , Academic Medical Centers/standards , Academic Medical Centers/statistics & numerical data , Cross-Sectional Studies , Commerce/standards , Commerce/statistics & numerical data , Information Dissemination , Internet/statistics & numerical data , Retinal Detachment
5.
Rev. bras. oftalmol ; 66(4): 267-270, jul.-ago. 2007. ilus
Article in Portuguese | LILACS | ID: lil-481144

ABSTRACT

Descreve o diagnóstico e conduta em um caso de hemorragia de disco óptico possivelmente secundária a descolamento espontâneo do vítreo posterior. Relata um caso de hemorragia de disco óptico possivelmente secundária a descolamento espontâneo do vítreo posterior, discutindo os aspectos diagnósticos, prognósticos e conduta oftalmológica.Observou-se regressão da hemorragia do disco após 6h de evolução do quadro sem sinais de recidiva durante os registros subseqüentes. A Oftalmoscopia com Laser de Varredura mostrou-se como um avançado método alternativo e eficaz no diagnóstico e seguimento do descolamento vítreo.


To describe the diagnosis and management of a optic disc haemorrhage probably caused by an acute and spontaneous posterior vitreous detachment. A single case-report of an optic disc haemorrhage probably caused by an spontaneous posterior vitreous detachment, in order to discuss the diagnosis, management and prognosis. Optic disc haemorrhage regression was observed after 6 hours of evolution without relapsing signals during the subsequent registers. The Scanning Laser Ophthalmoscopy revealed as an advanced alternative and efficient method in the vitreous detachment diagnosis and follow up.


Subject(s)
Humans , Male , Middle Aged , Vitreous Detachment/complications , Optic Disk/blood supply , Retinal Hemorrhage/etiology
6.
Arq. bras. oftalmol ; 70(1): 143-147, jan.-fev. 2007. ilus
Article in Portuguese | LILACS | ID: lil-453145

ABSTRACT

OBJETIVOS: Avaliar alterações estruturais observadas na síndrome de tração macular vítreo-retiniana idiopática (STMI) pela tomografia de coerência óptica (OCT), antes e depois da vitrectomia; identificar situações em que a tomografia de coerência óptica fornece informações adicionais da morfologia e patogênese desta doença. MÉTODOS: Imagens tomográficas (OCT Stratus) comparativas da estrutura vítreo-retiniana foram realizadas em quatro pacientes, em estágios variados da síndrome de tração macular vítreo-retiniana idiopática. RESULTADOS: A tomografia de coerência óptica Stratus apresenta imagens vítreo-retinianas que auxiliam na conduta e tratamento da síndrome de tração macular vítreo-retiniana idiopatica. CONCLUSÃO: O exame da tomografia de coerência óptica permite boa visualização da arquitetura morfológica do vítreo e da retina na síndrome de tração macular vítreo-retiniana idiopática. Este exame nos auxilia na compreensão da patogênese, no planejamento do tratamento, clínico ou cirúrgico, e na avaliação pós-operatória das alterações estruturais retinianas.


PURPOSE: To evaluate the features of idiophatic vitreomacular traction syndrome (VMT) with ocular coherence tomography (OCT - Stratus), before and after vitrectomy; to identify situations where ocular coherence tomography provides additional information on disease morphology and pathogenesis. METHODS: Comparative retinal ocular coherence tomography imaging was performed in four patients with different stages of vitreomacular traction syndrome. RESULTS: Standard-resolution ocular coherence tomography Stratus provides vitreous-retinal images that help the management and treatment of vitreomacular traction syndrome. CONCLUSIONS: Standard-resolution ocular coherence tomography allows good visualization of the architectural morphology of the vitreous and retina in vitreomacular traction syndrome. It helps understanding its pathogenesis, planning its treatment, clinical or surgical, and evaluating retinal structural alterations after surgery.


Subject(s)
Humans , Female , Middle Aged , Retinal Diseases/surgery , Tomography, Optical , Vitreous Detachment/surgery , Retinal Diseases , Syndrome , Treatment Outcome , Visual Acuity , Vitrectomy , Vitreous Detachment
SELECTION OF CITATIONS
SEARCH DETAIL