Results 1 - 14 de 14
Filter
1.
Arq. bras. cardiol ; 99(2): 697-705, ago. 2012. graf, tab
Article in Portuguese | LILACS | ID: lil-647716

ABSTRACT

FUNDAMENTO: O implante por cateter de bioprótese valvar aórtica é uma nova modalidade de tratamento para portadores de estenose aórtica inoperáveis ou de alto risco cirúrgico. Objetivo: Relatar a experiência de três anos do implante por cateter da bioprótese CoreValve. MÉTODOS: Entre janeiro de 2008 e janeiro de 2011, 35 pacientes com estenose aórtica (33 casos) ou disfunção de bioprótese valvar aórtica (dois casos) de alto risco cirúrgico foram submetidos ao implante da bioprótese CoreValve. RESULTADOS: A média de idade dos pacientes foi 81,5 ± 9 anos, e 80% apresentavam-se em classe funcional III ou IV de insuficiência cardíaca. O EuroScore foi 18,4 ± 14,3% e o STS 14,5 ± 11,6%. Obteve-se sucesso do implante em 34 (97,1%) pacientes. Após a intervenção houve redução do gradiente transvalvar de 84,9 ± 22 para 22,5 ± 9,5 mmHg e 87,1% dos pacientes evoluíram em classe funcional I ou II. A mortalidade aos 30 dias e no seguimento médio de 400 ± 298 dias foi, respectivamente, de 11,4% e 31,4%. A ocorrência de complicações hemorrágicas com risco de morte foi o único preditor independente de mortalidade cardiovascular. Acidente vascular cerebral ocorreu em 5,7% dos pacientes. Marca-passo permanente foi necessário em 32,1% dos casos no primeiro mês após o procedimento. CONCLUSÃO: O implante por cateter de bioprótese valvar aórtica é um procedimento seguro e eficaz para ser empregado em portadores de estenose aórtica de alto risco cirúrgico. O dispositivo CoreValve é eficaz no médio-prazo, em seguimento de até três anos.


BACKGROUND: Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE: To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS: From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction (two) at high surgical risk underwent transcatheter CoreValve® bioprosthesis implantation. RESULTS: The patients' mean age was 81.5 ± 9 years, and 80% had heart failure functional class III or IV. The EuroScore was 18.4 ± 14.3% and the STS risk score was 14.5 ± 11.6%. Successful device implantation was achieved in 34 (97.1%) patients. After the intervention, a reduction in the transvalvular pressure gradient from 84.9 ± 22 to 22.5 ± 9.5 mm Hg was observed, and 87.1% of the patients progressed to functional class I or II. Thirty-day mortality and mortality in the follow-up of 400 ± 298 days were 11.4% and 31.4%, respectively. The occurrence of life-threatening hemorrhagic complications was the only independent predictor of cardiovascular mortality. Stroke occurred in 5.7% of the patients. Permanent pacemaker was required in 32.1% of the patients within the first month after the procedure. CONCLUSION: Transcatheter aortic bioprosthesis implantation is a safe and effective procedure to be used in patients with aortic stenosis at high surgical risk. The CoreValve® prosthesis proved to have mid-term efficacy in a three-year follow-up.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve Stenosis/therapy , Bioprosthesis , Cardiac Catheterization/methods , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects , Endpoint Determination , Epidemiologic Methods , Heart Valve Prosthesis Implantation/adverse effects , Postoperative Complications , Treatment Outcome
2.
Rev. bras. cardiol. invasiva ; 20(3): 253-259, 2012. ilus, graf, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-656088

ABSTRACT

INTRODUÇÃO: A valvotomia mitral percutânea por balão é um procedimento seguro e eficaz em pacientes com estenose mitral grave sintomática selecionados, com resultados imediatos e a longo prazo semelhantes aos da intervenção cirúrgica. Este estudo tem o objetivo de descrever os resultados muito tardios das primeiras valvotomias mitrais percutâneas por balão realizadas em nossa instituição e identificar os fatores preditores de reestenose. MÉTODOS: No período de 1987 a 1991, 200 pacientes consecutivos foram submetidos a valvotomia mitral percutânea por balão. Avaliações clínica e ecocardiográfica foram realizadas antes do procedimento, 48 horas após e, então, anualmente. RESULTADOS: A média de idade foi de 32 ± 12 anos, 86,5% eram do sexo feminino e 80,5% encontravam-se em classe funcional III ou IV da New York Heart Association. A média do escore de Wilkins foi de 7,6 ± 1,2 e o sucesso do procedimento ocorreu em 87,5% (175/200) dos pacientes. Durante o seguimento, foram acompanhados 129 pacientes (74%) por 140 ± 79 meses. Reestenose após o primeiro procedimento ocorreu em 46,5% (60/129) dos pacientes, sendo realizada uma segunda valvotomia mitral percutânea por balão em 25 pacientes, uma terceira em 4 pacientes, e uma quarta em 1 paciente. Em cinco anos, a probabilidade livre de reestenose foi de 85%, em 10 anos foi de 60% e em 20 anos, de 36%. O diâmetro do átrio esquerdo (P = 0,034) e o gradiente transvalvar mitral tanto pré (P = 0,013) como pós-procedimento (P = 0,038) foram preditores de reestenose. CONCLUSÕES: Em seguimento clínico muito tardio, a valvotomia mitral percutânea por balão mostrou que os resultados são duradouros em mais de um terço dos pacientes e que a repetição do procedimento pode ser realizada com segurança em pacientes selecionados. A identificação dos preditores de reestenose é útil para guiar a seleção de casos para o procedimento.


BACKGROUND: Percutaneous balloon mitral valvotomy is safe and effective in patients with severe symptomatic mitral stenosis with immediate and long-term results comparable to those of surgical intervention. This study was aimed at reporting the very late follow-up results of the first percutaneous balloon mitral valvotomies performed at our institution and at identifying predictive factors of restenosis. METHODS: From 1987 to 1991, 200 consecutive patients were submitted to percutaneous balloon mitral valvotomy. Clinical and echocardiographic evaluations were performed prior to the procedure, 48 hours after the procedure and annually thereafter. RESULTS: Mean age was 32 ± 12 years; 86.5% were female and 80.5% were in New York Heart Association functional class III or IV. Mean Wilkins score was 7.6 ± 1.2 and procedure success was observed in 87.5% (175/200) of the patients. During follow-up, 129 patients (74%) were followed up for 140 ± 79 months. Restenosis was observed after the first procedure in 46.5% (60/129) patients and a second percutaneous balloon mitral valvotomy was performed in 25 patients, a third one in 4 patients and a fourth one in 1 patient. The probability of being restenosis-free was 85% at 5 years, 60% at 10 years and 36% at 20 years. Left atrial diameter (P = 0.034), and preoperative (P = 0.013) and postoperative (P = 0.038) transvalvar gradient were predictors of restenosis. CONCLUSIONS: In a very late clinical follow-up, percutaneous balloon mitral valvotomy provided long-lasting results in over one-third of the patients and showed that repeated procedures may be performed safely in selected patients. The identification of restenosis predictors is useful for patient selection.


Subject(s)
Humans , Male , Female , Adult , Catheterization , Mitral Valve Stenosis/complications , Mitral Valve Stenosis/diagnosis , Treatment Outcome , Echocardiography/methods , Echocardiography , Electrocardiography/methods , Electrocardiography , Observational Studies as Topic
3.
Braz. j. otorhinolaryngol. (Impr.) ; 77(6): 711-715, nov.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-608457

ABSTRACT

O manejo da estenose subglótica (ESG) em crianças continua sendo um desafio para os otorrinolaringologistas. A laringoplastia com balão (LPB) consiste num procedimento endoscópico, descrito inicialmente em 1984, para tratamento de estenoses da via aérea alta, apresentando várias vantagens em relação a outras técnicas cirúrgicas e com resultados promissores. OBJETIVO: Apresentar a nossa experiência com a realização de LPB em pacientes pediátricos com ESG. MATERIAL E MÉTODO: Estudo prospectivo de pacientes pediátricos com diagnóstico de ESG pós-extubação em evolução (ainda com tecido de granulação). Realizou-se laringoscopia direta sob anestesia geral e dilatação do segmento estenótico com cateter de angioplastia. Os pacientes foram acompanhados e nova laringoscopia foi realizada uma semana após o procedimento inicial. RESULTADOS: Foram incluídas no estudo oito crianças no período de junho de 2009 a outubro de 2010. Destas, quatro apresentavam ESG Grau 3, três apresentavam ESG Grau 2 e uma, ESG Grau 1. Na laringoscopia direta de revisão, apenas duas apresentavam ESG residual assintomática (Grau 1), sendo que as outras seis apresentavam via aérea normal e estavam assintomáticas. CONCLUSÃO: A LPB parece ser um tratamento efetivo para ESG em evolução. Necessitamos mais estudos para sabermos a eficácia, a segurança e as indicações deste procedimento.


Management of subglottic stenosis (SGS) in children is still a challenge to Otorhinolaryngologists. Balloon laryngoplasty (BLP) is an endoscopic procedure, first described in 1984 for the treatment of airway stenosis. It shows promising results and seems to be more effective than other procedures. AIM: To present our experience with BLP in children with SGS. MATERIAL AND METHOD: Prospective study of children diagnosed with acute subglottic stenosis, i.e., stenosis with granulation tissue. They underwent direct laryngoscopy under general anesthesia and dilatation of the stenotic segment with angioplasty balloon. They were followed up and a second laryngoscopy was performed one week later. RESULTS: Eight children were included in this study between June 2009 and October 2010. Four had Grade 3 SGS, three had Grade 2 SGS and one had Grade 1 SGS. By the second examination, two children presented with asymptomatic Grade 1 SGS, while the other six presented with normal airway and remained asymptomatic. CONCLUSION: BLP seems to be an effective treatment for acute SGS. We need more studies to refine our knowledge concerning efficacy rates, safety and indications for balloon dilatation.


Subject(s)
Female , Humans , Infant , Male , Catheterization , Laryngoplasty/methods , Laryngostenosis/therapy , Acute Disease , Intubation, Intratracheal/adverse effects , Laryngoscopy , Laryngostenosis/etiology , Prospective Studies , Severity of Illness Index , Treatment Outcome
4.
Rev. bras. cardiol. invasiva ; 19(1): 72-77, mar. 2011.
Article in Portuguese | LILACS | ID: lil-591722

ABSTRACT

Introdução: Apesar da alta prevalência de estenose mitral no Brasil, nota-se impressionante subnotificação dos procedimentos de tratamento percutâneo dessa afecção na literatura nacional. Este artigo tem como objetivo relatar os resultados e a evolução dos pacientes com estenose mitral reumática, tratados pela técnica de Inoue. Métodos: Foram analisados parâmetros clínicos, ecocardiográficos e relacionados ao procedimento de pacientes tratados no período de 1997 a 2009 e acompanhados por pelo menos um mês. Resultados: Foram avaliados 102 pacientes, a maioria do sexo feminino (89,2%), com média de idade de 38,1 + 11,1 anos, dos quais 80,4% estavam em classe funcional II-III. A área valvar média pela ecocardiografia (ECO) era de 1,01 + 0,19 cm2 e pelo cateterismo (CAT), de 0,87 + 0,2 cm2. O escore de Wilkins & Block estava entre 5 e 8 em cerca de 90% dos pacientes e 88,2% estavam em ritmo sinusal. O procedimento alcançou sucesso em 76,5% dos casos, com aumento da área valvar mitral média de 1,9 + 0,5 cm2 pelo ECO (P < 0,001) e de 2 + 0,5 cm2 pelo CAT (P < 0,001). O gradiente médio átrio esquerdo-ventrículo esquerdo reduziu- se de 16,6 mmHg para 4,2 mmHg (P < 0,001). O débito cardíaco aumentou de 3,75 l/min para 4,67 l/min (P < 0,001), sendo um preditor de sucesso para o procedimento. Em 79,4% dos pacientes obteve-se a evolução de um ano, em que 87,6% dos pacientes estavam em classe funcional I e apenas 2 pacientes necessitaram tratamento cirúrgico. Durante o seguimento de cinco anos não foi observado nenhum caso de acidente vascular cerebral ou óbito de causa cardíaca. Conclusões: A valvoplastia mitral por técnica de Inoue para o tratamento da estenose mitral reumática é técnica eficaz a médio prazo, e com baixa taxa de complicações.


Background: Despite the high prevalence of mitral stenosis in Brazil, there is a significant underreporting of percutaneous procedures in the treatment of this disease in the national literature. This study is aimed at reporting the results and course of patients with rheumatic mitral stenosistreated with the Inoue balloon. Methods: Clinical, echocardiographicand procedure-related parameters of patients treated from 1997 to 2009 who were followed-up for at least a month were evaluated. Results: One hundred and two patients were evaluated, most of them females (89.2%), with mean age of 38.1 + 11.1 years, 80.4% were in functional class II-III. Mean mitral valve area obtained by echocardiography (ECHO) was 1.01 + 0.19 cm² and 0.87 + 0.2 cm² byhemodynamic measurements (HEMO). Wilkins & Block score ranged from 5 to 8 in about 90% of the patients and 88.2% of them were in sinus rhythm. The procedure was successful in 76.5% patients with mean mitral valve area increasing to 1.9 + 0.5 cm² as measured by ECHO (P < 0.001) and to2 + 0.5 cm² as calculated by HEMO (P < 0.001). Mean left atrial-left ventricular gradient was reduced from 16.6 mmHgto 4.2 mmHg (P < 0.001). Cardiac output increased from 3.75 L/min to 4.67 L/min (P < 0.001) and this change was a predictor of success. Of 79.4% patients who were followedup for 1 year, 87.6% were in functional class I and only 2 cases required surgical treatment. During the 5-year follow-up there were no cases of stroke or death due to cardiac causes. Conclusions: Mitral valvuloplasty with the Inoue balloon is effective for the treatment of rheumatic mitral stenosis in the medium term and has a low complication rate.


Subject(s)
Humans , Male , Female , Rheumatic Heart Disease , Mitral Valve Stenosis , Catheterization , Cardiac Output , Echocardiography/classification
5.
Arq. bras. cardiol ; 95(2): 153-158, ago. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-557827

ABSTRACT

FUNDAMENTO: A ecocardiografia bidimensional à beira do leito tem sido utilizada com sucesso para guiar a atriosseptostomia com cateter balão, agilizando o procedimento e evitando os riscos do transporte para o laboratório de hemodinâmica. OBJETIVO: Avaliar os resultados da atriosseptostomia com cateter balão à beira do leito em neonatos cianóticos. MÉTODOS: Entre jan/1997 e jul/2008, foram realizados 102 procedimentos de atriosseptostomia com cateter balão guiados pela ecocardiografia, sendo avaliados níveis de saturação, diâmetro da comunicação, saturação de oxigênio, resposta clínico-laboratorial e complicações relacionadas ao procedimento. RESULTADOS: De um total de 102 casos de Rashkind realizados à beira do leito, 98 preencheram os critérios de inclusão, sendo 90 neonatos do Grupo A (procedimento de Rashkind em fase pré-operatória) e 8 do Grupo B (procedimento em fase pós-operatória). Houve predomínio do sexo masculino (75 por cento), a idade média foi de 8,3 ± 9,3 dias, o peso médio foi de 3.100 ± 1.100 g e a transposição das grandes artérias foi a cardiopatia congênita mais frequente (n = 74). Comparando-se os valores das saturações pré e pós-procedimento (65,9 ± 19,5 por cento e 86 ± 9,7 por cento) e o diâmetro da comunicação interatrial pré e pós-procedimento (2,3 ± 1,0 mm e 5,5 ± 1,3 mm) houve diferença estatisticamente significativa (p < 0,001). Comparando-se os valores das saturações e o diâmetro da comunicação interatrial nos grupos de sobreviventes e não sobreviventes não houve diferença estatisticamente significativa (p > 0,05). CONCLUSÃO: A atriosseptostomia com cateter guiada pela ecocardiografia reduz os riscos por possibilitar a efetiva paliação sem perda de tempo em neonatos cianóticos, além de apresentar menores custos hospitalares.


BACKGROUND: The bedside two-dimensional echocardiography (2-D ECHO) has been successfully used to guide the balloon atrial septostomy, speeding up the procedure and preventing the risks of transportation to the hemodynamics laboratory. OBJECTIVE: To assess the results of the bedside balloon atrial septostomy in cyanotic neonates. METHODS: Between January/1997 and July/2008, 102 atrioseptostomies by balloon catheter guided by echocardiography were carried out and saturation levels, defect diameter, oxygen saturation, clinical-laboratory response and complications related to the procedure were evaluated. RESULTS: Of 102 cases of bedside Rashkind septostomy, 98 met the inclusion criteria, with 90 neonates in Group A (Rashkind procedure in the preoperative phase) and 8 in Group B (procedure at the postoperative phase). There was a predominance of the male sex (75 percent), mean age was 8.3 ± 9.3 days and the mean weight was 3,100 ± 1,100 g; the transposition of the great arteries was the most frequent congenital heart disease (n = 74). When comparing the levels of saturation pre and post-procedure (65.9 ± 19.5 percent and 86 ± 9.7 percent) and the diameter of the interatrial septal defect pre and post-procedure (2.3 ± 1.0 mm and 5.5 ± 1.3 mm) there was a statistically significant difference (p < 0.001). When comparing the levels of saturation and the diameter of the interatrial septal defect between the group of survivors vs non-survivor, there was no statistically significant difference (p > 0.05). CONCLUSION: The balloon atrial septostomy guided by the echocardiography reduces the risks by allowing the effective palliative procedure to be carried out promptly in cyanotic neonates, in addition to presenting lower hospital costs.


Subject(s)
Female , Humans , Infant , Infant, Newborn , Male , Catheterization , Echocardiography/methods , Heart Septal Defects, Atrial/therapy , Transposition of Great Vessels/therapy , Ultrasonography, Interventional/methods , Catheterization , Heart Atria , Heart Septal Defects, Atrial , Intensive Care Units, Neonatal , Transposition of Great Vessels
6.
Rev. bras. ginecol. obstet ; 32(7): 346-351, jul. 2010. tab
Article in Portuguese | LILACS | ID: lil-567968

ABSTRACT

OBJETIVO: comparar a efetividade da sonda e Foley com o uso de misoprostol vaginal para o preparo cervical e indução do parto. MÉTODOS: ensaio clínico randomizado, não cego, realizado entre Janeiro de 2006 a Janeiro de 2008. Foram incluídas 160 gestantes com indicação de indução do parto, divididas em dois grupos: 80 para uso da sonda de Foley e 80 para misoprostol vaginal. Os critérios de inclusão foram: idade gestacional a partir de 37 semanas, feto único, vivo, cefálico e índice de Bishop igual ou menor que 4. Foram excluídas pacientes com cicatriz uterina, ruptura das membranas, peso fetal estimado maior que 4000 g, placenta prévia, corioamnionite e condições que impunham o término imediato da gestação. Os testes estatísticos utilizados foram Mann-Whitney, χ2 de Pearson ou exato de Fischer, sendo considerado significativo se menor que 0,005. RESULTADOS: o misoprostol desencadeou mais vezes o parto de forma espontânea (50,0 versus 15,0 por cento para Foley p<0,001) e menor uso de ocitocina (41,2 versus 76,2 por cento), sendo que esse grupo apresentou mais taquissistolia (21,2 versus 5,0 por cento). A sonda de Foley causou mais desconforto à paciente (28,7 versus 1,2 por cento). Não houve diferenças em relação ao tempo necessário para evolução do índice de Bishop (20,69 versus 21,36 horas), para o desencadeamento do parto (36,42 versus 29,57 horas) e nas taxas de cesáreas (51,2 versus 42,5 por cento). Não houve diferenças significativas no desempenho perinatal, com frequências semelhantes de cardiotocografia anormal (20,0 versus 21,2 por cento), presença de mecônio (13,7 versus 17,5 por cento) e necessidade de UTI neonatal (3,7 versus 6,2 por cento). CONCLUSÕES: o uso da sonda de Foley apresentou efetividade semelhante ao misoprostol para o preparo cervical, porém foi menos efetivo para o desencadeamento espontâneo do parto. Nossos resultados apoiam a recomendação de seu uso para o preparo cervical, sobretudo em pacientes portadoras de uma cicatriz de cesárea.


PURPOSE: to compare the effectiveness of the Foley balloon with vaginal misoprostol for cervical ripening and labor induction. METHODS: randomized clinical trial, not blind, conducted from January 2006 to January 2008. A total of 160 pregnant women with indication for induction of labor were included and divided into two groups, 80 for Foley and 80 for vaginal misoprostol. Inclusion criteria were: gestational age of 37 weeks or more, a live single fetus with cephalic presentation and a Bishop score of four or less. We excluded patients with a uterine scar, ruptured membranes, estimated fetal weight greater than 4000 g, placenta previa, chorioamnionitis and conditions that imposed the immediate termination of pregnancy. Statistical tests employed were Mann-Whitney, χ2 test or Fisher's exact test, and p value was significant if less than 0.005. RESULTS: misoprostol triggered more frequently spontaneous delivery (50.0 versus 15.0 percent for Foley, p<0.001) and required less use of oxytocin (41.2 versus 76.2 percent), and this group presented more tachysystole (21.2 versus 5.0 percent). The Foley catheter caused more discomfort to the patient (28.7 versus 1.2 percent). There were no differences in the time required for development of the Bishop score (20.69 versus 21.36 hours), for triggering delivery (36.42 versus 29.57 hours) or in rates of cesarean delivery (51.2 versus 42.5 percent). There were no significant differences in perinatal performance, with similar rates of abnormal cardiotocography (20.0 versus 21.2 percent), presence of meconium (13.7 versus 17.5 percent) and need for neonatal intensive care unit (3.7 versus 6.2 percent). CONCLUSIONS: the use of the Foley catheter was as effective as misoprostol for cervical ripening, but less effective in triggering spontaneous labor. Our results support the recommendation of its use for cervical ripening, especially in patients with cesarean scar.


Subject(s)
Adolescent , Adult , Female , Humans , Pregnancy , Young Adult , Cervical Ripening/drug effects , Labor, Induced/methods , Misoprostol/administration & dosage , Oxytocics/administration & dosage , Catheterization , Cervix Uteri , Vagina
7.
Arq. bras. cardiol ; 94(3): 406-413, mar. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-545830

ABSTRACT

FUNDAMENTO: A análise dos resultados imediatos e a longo prazo da valvoplastia mitral por catéter-balão (VMCB) ainda são escassos na literatura, principalmente no contexto nacional. OBJETIVO: Avaliar os resultados imediatos e tardios dos pacientes submetidos à VMCB. MÉTODO: 330 pacientes consecutivos foram seguidos por 47 ± 36 meses (até 126 meses). Análises univariadas e multivariadas avaliaram os fatores relacionados ao sucesso do procedimento, à reestenose e aos eventos tardios (morte ou necessidade de nova intervenção na valva mitral). O método de Kaplan-Meier estimou a sobrevida livre de eventos. RESULTADOS: Houve sucesso do procedimento em 305 (92,4 por cento). A anatomia valvar mitral foi o principal preditor de sucesso imediato do procedimento. Durante o seguimento, a reestenose ocorreu em 77 (23,3 por cento) pacientes e esteve associada a menor área valvar mitral e maior calcificação antes do procedimento. Ocorreram 67 eventos em um tempo médio de seguimento de 38 ± 26 meses. A probabilidade de sobrevida livre de eventos foi de 95 por cento em 1 ano, 75 por cento aos 5 anos e 61 por cento aos 10 anos. Os preditores de sobrevida livre de eventos foram: idade, escore ecocardiográfico e resultado imediato do procedimento. CONCLUSÃO: A VMCB é um procedimento efetivo, sendo que mais de 60 por cento dos pacientes estiveram livres de eventos ao final do seguimento. A condição anatômica da valva mitral e a idade do paciente foram os melhores preditores da sobrevida livre de eventos e devem ser levados em consideração na seleção dos pacientes para VMCB.


BACKGROUND: The analysis of immediate and long-term results of mitral valvoplasty by balloon catheter (MVRBC) are still lacking in literature, mainly in the national context. OBJECTIVE: To assess the immediate and late results of patients submitted to mitral valve repair by balloon catheter. METHOD: A total of 330 consecutive patients were followed-up by 47 ± 36 months (up to 126 months). Univariate and multivariate analyses assessed the factors associated with the success of the procedure, restenosis and late events (death or necessity of new intervention on mitral valve). Kaplan-Meier method estimated survival without events. RESULTS: The procedure was successful in 305 cases (92.4 percent). The mitral valve anatomy was the main predictor for immediate success for the procedure. During the procedure, restenosis occurred in 77 (23.3 percent) patients and was associated with smaller mitral valve area and with larger calcification before the process. In a mean period of 38 ± 26-month follow-up, 67 events occurred. The probability of survival without events was of 95 percent in one year, 75 percent in five years and 61 percent in ten years. The predictors of survival without events were: age, echocardiography score and immediate result of the procedure. CONCLUSION: Mitral valve repair by balloon catheter is an effective procedure, as 60 percent patients did not present events after the follow-up. The anatomical condition of the mitral valve and the patient's age were the best predictors of survival without events, and should be taken into account when selecting patients for the mentioned procedure. (Arq Bras Cardiol 2010; 94(3):383-390)


Subject(s)
Female , Humans , Male , Catheterization , Mitral Valve Stenosis/therapy , Coronary Restenosis/etiology , Epidemiologic Methods , Mitral Valve Stenosis , Treatment Outcome
8.
Arq. bras. cardiol ; 93(6): 666-671, dez. 2009. ilus
Article in English, Spanish, Portuguese | LILACS | ID: lil-542750

ABSTRACT

Fundamento: O isolamento das veias pulmonares (IVP) tem sido usado como endpoint para a ablação da fibrilação atrial (FA) com cateter balão. Objetivo: Determinar a utilidade do ultrassom intracardíaco (USIC) para guiar o IVP, usando cateter balão a laser. Métodos: 59 VP foram ablacionadas em 27 cães. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sanguíneo entre a VP e o balão. Após cada liberação de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posição de vazamento foi então correlacionada com a posição do gap no estudo patológico. A análise de regressão logística multivariada foi realizada. Resultados: Cinquenta e nove VP foram submetidas à ablação. O tempo médio de energia liberada foi de 279±177 seg., o diâmetro médio do balão era de 23±3 mm, e o comprimento médio do balão era 25±4 mm. O isolamento completo foi obtido em 38/59 (64 por cento), e foi significantemente mais comum sem vazamento: [30/38 (79 por cento) versus 8/23 (35 por cento), p<0,001]. Isso foi independente do tempo de aplicação (302±223 seg. vs. 266±148 sec., p=ns), potência (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), diâmetro do balão (24± 3 mm vs. 22± 3 mm, p= ns) e comprimento (27±4 mm vs. 24±4 mm, p=ns). O valor preditivo positivo para previsão de isolamento completo foi de 65 por cento e o valor preditivo negativo foi 83 por cento. Conclusão: Um vazamento identificável entre a VP e o dispositivo de ablação por cateter-balão observado no USIC é preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser útil para detectar vazamentos a fim de evitar o uso ineficaz de aplicação energia durante a ablação circunferencial da VP. Isto também pode ser útil quando outras energias são utilizadas.


Background: Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation. Objective: To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter. Methods: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. Results: 59 PV were ablated. Mean burn time was 279±177 sec, mean balloon diameter was 23±3 mm, and mean balloon length was 25±4 mm. Complete isolation was achieved in 38/59 (64 percent) cases, and it was significantly more common when there was no leak: [30/38 (79 percent) versus 8/23 (35 percent), p<0.001]. This occurred regardless of time of laser application (302±223 sec. vs. 266±148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24± 3 mm vs. 22± 3 mm, p=ns) and length (27±4 mm vs. 24±4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65 percent and the negative predictive value was 83 percent. Conclusion: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.


Fundamento: Se usó el aislamiento de las venas pulmonares (AVP) como endpoint para la ablación de la fibrilación atrial (FA) con catéter-balón. Objetivo: Determinar la utilidad del ultrasonido intracardíaco (USIC) para guiar el AVP, usando catéter-balón láser. Métodos: Se ablacionaron 59 VP en 27 perros. Se usaron imágenes de Doppler para identificar los derrames del flujo sanguíneo entre la VP y el balón. Tras cada liberación de energía, se reposicionó el catéter de mapeamiento circular para verificar si se obtuvo el aislamiento. Se correlaccionó, entonces, la posición del derrame con la posición del gap en el estudio patológico. Se realizó el análisis de regresión logística multivariada. Resultados: Se sometieron 59 VP a la ablación. El tiempo promedio de energía liberada fue de 279±177 seg., el diámetro promedio del balón era de 23±3 mm, y la largura promedio del balón era 25±4 mm. Se obtuvo el aislamiento completo en 38/59 (64 por ciento), y fue significantemente más común sin derrame: [30/38 (79 por ciento) versus 8/23 (35 por ciento), p<0,001]. Eso fue independiente del tiempo de aplicación (302±223 seg. vs. 266±148 sec., p=ns), potencia (3,5 W/cm, 4,5 W/cm, y 5,5 W/cm), diámetro del balón (24± 3 mm vs. 22± 3 mm, p= ns) y largura (27±4 mm vs. 24±4 mm, p=ns). El valor predictivo positivo para la previsión del aislamiento completo fue del 65 por ciento y el valor predictivo negativo fue del 83 por ciento. Conclusión: Un derrame identificable entre la VP y el dispositivo de ablación por catéter-balón observado en el USIC es predictor de menor tasa del aislamiento de la VP más baja. El USIC puede ser útil para detectar derrames a fin de evitar el uso ineficaz de la aplicación de la energía durante la ablación circunferencial de la VP. Ello también puede ser útil cuando se utilizan otras energías.


Subject(s)
Animals , Dogs , Male , Catheter Ablation/methods , Intraoperative Complications , Lasers/adverse effects , Pulmonary Veins/surgery , Ultrasonography, Interventional , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Epidemiologic Methods , Models, Animal , Pulmonary Veins/injuries , Pulmonary Veins , Ultrasonography, Doppler, Color/standards
9.
Arq. bras. cardiol ; 93(6): e89-e92, dez. 2009. tab, ilus
Article in English, Spanish, Portuguese | LILACS | ID: lil-542754

ABSTRACT

O aumento do débito cardíaco durante a gravidez é causa de insuficiência cardíaca em portadoras de estenose valvar aórtica grave. A valvoplastia aórtica percutânea tem sido associada a graves complicações e reestenose valvar em curto prazo. O presente caso mostrou que a valvoplastia aórtica percutânea permitiu o alcance do parto com sobrevida da mãe e do feto, e que a interrupção do tratamento no pós-parto resultou em morte materna no puerpério tardio.


The increase of cardiac output during pregnancy is the cause of heart failure in women with severe aortic valvular stenosis. Percutaneous aortic valvuloplasty has been associated with severe complications and short-term valvar restenosis. This case showed that percutaneous aortic valvuloplasty allowed both mother and fetus to survive after childbirth, and that postpartum treatment interruption resulted in maternal death in late postpartum care.


El aumento del gasto cardiaco durante el embarazo es la causa de insuficiencia cardiaca en portadoras de estenosis valvular aórtica severa. Se viene asociando la valvuloplastia aórtica percutánea a severas complicaciones y reestenosis valvular en corto plazo. El presente caso reveló que la valvuloplastia aórtica percutánea permitió el alcance del parto con sobrevida de la madre y del feto, y que la interrupción del tratamiento en el postparto resultó en muerte materna en el puerperio tardío.


Subject(s)
Adolescent , Female , Humans , Pregnancy , Angioplasty, Balloon, Coronary/adverse effects , Aortic Valve Stenosis/surgery , Pregnancy Complications, Cardiovascular/surgery , Angioplasty, Balloon, Coronary/instrumentation , Emergencies , Fatal Outcome , Patient Dropouts , Pregnancy Outcome
10.
Arq. bras. oftalmol ; 72(5): 669-672, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-534189

ABSTRACT

OBJETIVO: Verificar o resultado da técnica, inédita no Brasil, de dilatação do ducto lacrimonasal usando cateter-balão para tratamento da obstrução congênita do ducto lacrimonasal. MÉTODOS: Foram tratadas crianças com idade entre dois e cinco anos, com obstrução congênita de vias lacrimais usando o cateter-balão (Lacricath®) para dilatação das vias lacrimais. O cateter foi introduzido pelo ponto lacrimal superior, sob anestesia geral. RESULTADOS: Entre os 27 olhos tratados, 23 apresentaram desaparecimento dos sinais e sintomas de lacrimejamento (taxa de sucesso de 85,2 por cento). Todos os procedimentos foram realizados sem intercorrências e o seguimento pós-operatório mínimo foi de um ano. CONCLUSÃO: A dilatação com balão mostrou-se segura e eficiente como primeiro procedimento para os casos de obstrução congênita das vias lacrimais em crianças com mais de dois anos.


Purpose: To verify the results of balloon-catheter dilatation for the treatment of congenital lacrimal duct obstruction. To the best of author's knowledge this procedure has not been previously used in Brazil and deserves scientific studies. METHODS: Children between 2 and 5 years old, with congenital lacrimal duct obstruction, were treated with balloon-catheter dilatation (Lacricath®). Catheter was introduced by the superior lacrimal punctum, under general anesthesia. RESULTS: Twenty-seven eyes were treated and 23 presented total improvement of epiphora signs and symptoms (85.2 percent success rate). During a one year follow-up, all the procedures had good outcomes, without complications and all the children had 1 year of follow-up. CONCLUSION: Balloon-catheter dilatation is an efficient and safe procedure and might be used for congenital lacrimal duct obstruction treatment in children older than 2 years.


Subject(s)
Child, Preschool , Female , Humans , Male , /methods , Lacrimal Duct Obstruction/therapy , /instrumentation , Follow-Up Studies , Lacrimal Duct Obstruction/congenital , Prospective Studies , Treatment Outcome
11.
Arq. bras. cardiol ; 93(3): 299-306, set. 2009. ilus, tab
Article in English, Spanish, Portuguese | LILACS | ID: lil-529178

ABSTRACT

FUNDAMENTO: A substituição percutânea da valva aórtica para o tratamento da estenose aórtica é uma alternativa disponível e eficaz para pacientes com alto risco cirúrgico, especialmente aqueles com idade avançada e comorbidades. OBJETIVO: Os autores relatam a experiência inicial do emprego da endoprótese CoreValve em nosso meio. MÉTODOS: Em janeiro de 2008, dois pacientes foram submetidos à substituição percutânea da valva aórtica por estenose aórtica sintomática. Ambos foram selecionados por terem idade avançada (77 e 87 anos), comorbidades e elevado risco cirúrgico (EuroScore 7,7 por cento e 12,1 por cento). RESULTADOS: Os implantes percutâneos do dispositivo CoreValve foram realizados com sucesso. Observou-se a ampliação da área valvar (de 0,7 para 1,5 cm² e de 0,5 para 1,3 cm²) e a redução do gradiente transvalvar aórtico (de 82 para 50 mmHg e de 94 para 31 mmHg) imediatamente após a intervenção. Durante a internação hospitalar, houve a necessidade de implantar marca-passos definitivos nos dois pacientes, por bloqueio átrio-ventricular. Aos seis meses, observou-se a queda ainda maior do gradiente transvalvar aórtico (gradiente < 20 mmHg), e a remissão dos sintomas de insuficiência cardíaca (NYHA III para NYHA I). CONCLUSÃO: O emprego da endoprótese CoreValve para o tratamento da estenose aórtica mostrou-se factível e com resultados animadores nesta experiência inicial em nosso meio.


BACKGROUND: Percutaneous aortic valve replacement for the treatment of aortic stenosis is an available and efficient alternative for patients at high surgical risk, especially those with advanced age and comorbidities. OBJECTIVE: The authors report the first experience made in our midst with the use of the CoreValve endoprosthesis. METHODS: In January 2008, two patients underwent percutaneous aortic valve replacement due to symptomatic aortic stenosis. They were selected for being elderly (77 and 87 years) and presenting comorbidities and a high surgical risk (EuroScore 7.7 percent and 12.1 percent). RESULTS: Percutaneous implantations of the CoreValve device were successfully performed. Enlargement of the valve area (from 0.7 to 1.5 cm² and from 0.5 to 1.3 cm²) and reduction of the aortic transvalvular gradient (from 82 to 50 mmHg and from 94 to 31 mmHg) were observed immediately after the intervention. During hospital stay, permanent pacemaker implantation was required in both patients due to atrioventricular block. At six months, an even greater drop in the aortic transvalvular gradient (gradient < 20 mmHg) and remission of symptoms of heart failure (NYHA III to NYHA I) were observed. CONCLUSION: The use of the CoreValve endoprosthesis for the treatment of aortic stenosis proved to be feasible and showed encouraging results in this early experience made in our midst.


FUNDAMENTO: La sustitución percutánea de la válvula aórtica en el tratamiento de la estenosis aórtica es una alternativa disponible y eficaz para pacientes de alto riesgo quirúrgico, especialmente los de edad avanzada y comorbilidades. OBJETIVO: Los autores relatan la experiencia inicial del empleo de la endoprótesis CoreValve en nuestro medio. MÉTODOS: En enero de 2008 se sometió a dos pacientes a la sustitución percutánea de la válvula aórtica por estenosis aórtica sintomática. A ambos se les seleccionó por su edad avanzada (77 y 87 años), comorbilidades y alto riesgo quirúrgico (EuroScore 7,7 por ciento e 12,1 por ciento). RESULTADOS: Los implantes percutáneos del dispositivo CoreValve se realizaron exitosamente. Se observó la ampliación del área valvular (de 0,7 para 1,5 cm² y de 0,5 para 1,3 cm²) y la reducción del gradiente transvalvular aórtico (de 82 para 50 mmHg e de 94 para 31 mmHg) inmediatamente después de la intervención. Durante la internación hospitalaria se hizo necesario implantar marcapasos definitivos en ambos pacientes, a causa de bloqueo atrioventricular. Se observó seis meses después una queda aún más grande del gradiente transvalvular aórtico (gradiente < 20 mmHg) y la remisión de los síntomas de insuficiencia cardiaca (NYHA III para NYHA I). CONCLUSIÓN: El empleo de la endoprótesis CoreValve para el tratamiento de la estenosis aórtica se reveló factible y los resultados, en esa experiencia inicial en nuestro medio, han sido prometedores.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/pathology , Bioprosthesis , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/instrumentation , Stents
12.
Rev. Col. Bras. Cir ; 36(3): 217-222, jul. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-522450

ABSTRACT

OBJETIVO: Discutir a estratégia cirúrgica para tratamento de lesões hepáticas penetrantes graves através de tamponamento com balão intra-hepático. MÉTODOS: Estudo retrospectivo com 18 pacientes com trauma hepático penetrante, tratados com balão, atendidos em um hospital de referência em trauma no sul do Brasil. Foram avaliados: idade, sexo, grau da lesão hepática, segmentos acometidos, quantidade de solução salina infundida no balão intra-hepático e seu tempo de permanência, lesões associadas, terapia nutricional, hemotransfusões, complicações, antibioticoterapia, necessidade de UTI e tempo de internamento. RESULTADOS: Todos os pacientes eram do sexo masculino com idade média de 22,5 anos (18-48). As feridas por arma de fogo foram mais prevalentes, sendo a localização mais comum a região torácica e a transição tóraco-abdominal. A lesão associada mais comum foi a do diafragma, e o segmento hepático mais acometido foi o VIII (29,6 por cento). Sete pacientes (38,9 por cento) sobreviveram e a complicação mais comum foi fístula biliar (42,8 por cento). Dos 11 (61,1 por cento) pacientes que foram a óbito, seis morreram no mesmo dia em que foram operados, três ficaram em média 18,6 dias internados e os demais morreram no 2° e 3° do pós-operatório. CONCLUSÃO: O tratamento das lesões hepáticas transfixantes costuma ser de difícil manejo cirúrgico e com alto índice de morbimortalidade. O uso do balão intra- hepático foi eficaz no tratamento dessas lesões, porém não é isento de complicações tendo suas indicações bem definidas.


OBJECTIVE: The authors discuss the surgical strategies in the management of complex penetrating hepatic lesions through liver balloon tamponade. METHODS: Eighteen patients who received care in a trauma referral center in southern Brazil over the last 5 years were selected retrospectively. Data and variables evaluated were age, sex, hepatic injury grade and location, amount of saline solution filling the balloon and the length of time it was kept in place, associated injuries, the nutritional therapy instituted, hem concentrate transfusion, complications, antibiotics use, ICU need and length of hospital stay. RESULTS: All patients were male with an average age of 22.5 years (18-48). Gunshot wounds were more prevalent than stab wounds and their most common locations were the thorax and thoraco-abdominal regions. The m most commonly associated injury was in the diaphragm, and Couinaud segment VIII was the most often injured hepatic region (29.6 percent). Seven patients (38.9 percent) survived and the most common complication were biliary fistulae (42.8 percent). From the eleven deceased patients (61.1 percent), 6 died on the day of admission, 3 stayed for 18.6 days in hospital and the others died on the 2nd and 3rd postoperative days. CONCLUSION: Transfixing hepatic lesions are usually difficult to manage and carry high morbidity and mortality rates. The use of intrahepatic balloon tamponade can be useful as a therapeutic tool, but not rid of complications, and for that reason it has specific and selected indications.


Subject(s)
Adolescent , Adult , Humans , Male , Middle Aged , Young Adult , Liver/injuries , Wounds, Penetrating/therapy , Brazil , /methods , Hospitals, University , Retrospective Studies , Young Adult
13.
Arq. bras. cardiol ; 91(5): e45-e47, nov. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-501818

ABSTRACT

A ocorrência de Hemopericárdio com Tamponamento Cardíaco é uma complicação da Valvoplastia Mitral Percutânea por balão (VMB), que apesar de pouco freqüente, pode ter graves conseqüências materno-fetais. Este artigo descreve o caso de um tamponamento cardíaco após VMB em uma mulher de 28 anos, com estenose mitral reumática severa na 20ª semana de gravidez.


The occurrence of hemopericardium with cardiac tamponade is a complication of percutaneous balloon mitral valvuloplasty (BMV) which, although uncommon, may have severe maternal and fetal consequences. This article describes a case of cardiac tamponade following BMV in a 28-year-old woman with severe rheumatic mitral stenosis in the 20th week of gestation.


Subject(s)
Adult , Female , Humans , Pregnancy , /adverse effects , Cardiac Tamponade/etiology , Mitral Valve Stenosis/therapy , Pregnancy Complications, Cardiovascular , Pericardial Effusion/etiology , Rheumatic Heart Disease/therapy , Pregnancy Complications, Cardiovascular/etiology , Pregnancy Complications, Cardiovascular/therapy
14.
Arq. bras. cardiol ; 89(1): 52-59, jul. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-459816

ABSTRACT

OBJETIVO: Analisar a evolução a longo prazo de pacientes submetidos a valvoplastia mitral percutânea por balão com a técnica do balão de Inoue versus a técnica do balão único Balt, identificando os fatores que predisseram óbito e eventos maiores (óbito, nova valvoplastia mitral por balão ou cirurgia valvar mitral). MÉTODOS: O período de seguimento, nos grupos do balão único e do balão de Inoue, foi de 54 ± 31 (1 a 126) meses e de 34 ± 26 (2 a 105) meses, respectivamente (p < 0,0001). O balão único Balt foi usado em 254 (84,1 por cento) pacientes e o balão de Inoue, em 48 (15,9 por cento). RESULTADOS: Foram encontrados os seguintes dados, respectivamente, no grupo do balão de Inoue e do balão único: idade, 36,9 ± 10,4 (19 a 63) anos e 38,0 ± 12,6 (13 a 83) anos (p = 0,5769); escore ecocardiográfico, 7,5 ± 1,3 pontos e 7,2 ± 1,5 pontos (p = 0,1307); sexo feminino, 72,9 por cento e 87,4 por cento (p = 0,0097); fibrilação atrial, 10,4 por cento e 16,1 por cento (p = 0,4275); mortalidade no seguimento, 2,1 por cento e 4,3 por cento (0,6984); e eventos maiores, 8,3 por cento e 17,7 por cento (p = 0,1642). Não houve, na análise univariada e nas curvas de Kaplan-Meier, diferença entre as técnicas de Inoue e do balão único Balt para sobrevida e sobrevida livre de eventos maiores. Na análise multivariada, idade > 50 anos e escore ecocardiográfico > 8 predisseram, independentemente, óbito, e escore ecocardiográfico > 8 e área valvar mitral pós-procedimento < 1,50 cm² predisseram eventos maiores. CONCLUSÃO: Não houve diferença na evolução a longo prazo dos pacientes submetidos a técnica de Inoue versus a do balão único. Predisseram óbito e/ou eventos maiores: idade > 50 anos, escore ecocardiográfico > 8 e área valvar mitral pós-procedimento < 1,50 cm².


OBJECTIVE: To analyze the long term evolution of patients undergoing percutaneous balloon mitral valvoplasty comparing the Inoue and Balt single balloon methods, and to identify predictors of death and major events (death, repeat balloon mitral valvoplasty or mitral valve surgery). METHODS: The follow-up for the single and Inoue balloon groups were 54 ± 31 (1 to 126) months and 34 ± 26 (2 to 105) months, respectively (p < 0.0001). The Balt single balloon was used in 254 (84.1 percent) patients and the Inoue balloon in 48 (15.9 percent). RESULTS: The following data were found for the Inoue and single balloon groups, respectively: age, 36.9 ± 10.4 (19 to 63) years and 38.0 ± 12.6 (13 to 83) years (p = 0.5769); echocardiographic score, 7.5 ± 1.3 points and 7.2 ± 1.5 points (p = 0.1307); female gender, 72.9 percent and 87.4 percent (p = 0.0097); atrial fibrillation, 10.4 percent and 16.1 percent (p = 0.4275); mortality during follow-up, 2.1 percent and 4.3 percent (0.6984); and major events, 8.3 percent and 17.7 percent (p = 0.1642). Univariate and Kaplan-Meier curve analyses revealed no differences between the Inoue and Balt single balloon techniques in relation to survival and major event free survival. In the multivariate analysis, age > 50 years and an echocardiographic score > 8 were independent predictors of death; and an echocardiographic score > 8 and post operative mitral valve area < 1.50 cm² were predictors for major events. CONCLUSION: No differences were found in the long term evolution of patients undergoing the Inoue versus the single balloon technique. Predictors of death and/or major events were: age > 50 years, echocardiographic score > 8 and mitral valve area < 1.50 cm² after the procedure.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , /methods , Mitral Valve Stenosis/therapy , Age Factors , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , /adverse effects , /mortality , Epidemiologic Methods , Echocardiography/statistics & numerical data , Mitral Valve Stenosis , Mitral Valve , Reference Values , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL