Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 249
Filter
1.
J. appl. oral sci ; 32: e20230307, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550469

ABSTRACT

Abstract Objective To determine whether intra-mucosal injection of injectable platelet-rich fibrin (i-PRF) can promote healing after Diode Laser Gingival Depigmentation (DLGD). Methodology A total of 20 arch sites of hyperpigmented gingiva of 10 patients underwent DLGD. For each patient, two arch sites were randomly assigned for either intra-mucosal injection of i-PRF (G1-i-PRF) (n=10 sites) or no treatment (G2-Control): (n=10 sites). Wound Healing Score (WHS), patient satisfaction, and Pigmentation Index (DOPI) were measured at 1 week and 1 and 3 months postoperatively. Histological assessment of tissue specimens was performed at baseline and 1 week. Results The percentage change in WHS at 1 week was significantly higher in G1 (58.34±15.43) compared to G2 (37.50±11.79). At day 1, 50% of patients in G1 were pain free compared with 75% in G2, who had mild pain. Mean DOPI decreased significantly at 3 months in both groups (P-value <0.001), without significant differences between groups. G1 specimens showed significantly higher epithelial thickness (P-value <0.001), as well as a higher number of blood vessels and less percentage of inflammatory cells. Conclusions i-PRF demonstrated better clinical and histological healing potential and less patient discomfort compared to sites without treatment after DLGD. Registered at https://clinicaltrials.gov/ as (NCT05283668).

2.
Braz. oral res. (Online) ; 38: e025, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1557355

ABSTRACT

Abstract Treatment of oral vascular anomalies (OVA) has focused on minimally invasive techniques rather than radical surgery. We investigated the efficacy and safety of diode laser using the photocoagulation technique in the management of OVA. Forty-seven subjects with OVA were treated with forced dehydration with induced photocoagulation (FDIP) using diode laser (808 nm/4.5 W). This series consisted mostly of male (63.8%) and non-white (63.8%) patients with a mean age of 57.4 years. Varices (91.5%), venous malformations (6.4%), and hemangiomas (2.1%) with a mean size of 7.1 (±4.9) mm were the conditions treated. OVA presented as a nodular lesion (63.8%) involving mainly the lower lip (46.8%). Pulsed laser mode was used as standard and the number of applications varied from one to four sessions, with the majority requiring only one (83%) FDIP session. Kaplan-Meier analysis revealed that complete clinical healing can occur on the 15th day (n=9/29.5%), followed by the 20th (n=6/45.5%), and 30th (n=7/70.5%) days. Postoperative edema was observed in 31 (66%) patients, and recurrence of the lesion occurred in two (4.2%). Based on the data on complete clinical healing, minimal patient discomfort, and satisfactory esthetic results, we can confirm that FDIP by diode laser is a promising candidate for the safe and efficacious treatment of OVA.

3.
J. appl. oral sci ; 32: e20230419, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1558236

ABSTRACT

Abstract Oral soft tissue lesions require a precise diagnosis by oral biopsy with the ability to recognize these lesions within histopathological levels, so the instrument used for the incisions should be safe and cause little to no harm to the surrounding tissue. Objective This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. Methodology The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. Results The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. Conclusion The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.

4.
Article in Portuguese | LILACS | ID: biblio-1538268

ABSTRACT

Introdução: A laserterapia de alta potência tem estabelecido proporções satisfatórias na odontologia e se tornando a primeira opção de conduta cirúrgica para procedimentos, trazendo qualidade de vida aos pacientes e praticidade aos Cirurgiões. Objetivo: Relatar caso clínico de frenectomia lingual com uso do laser de diodo de alta potência ressaltando os benefícios da conduta. Relato de caso: Paciente sexo feminino, leucoderma, sem alterações sistêmicas, chega à Clínica Escola de Odontologia da Universidade Federal de Campina Grande, com queixa principal de alterações na sua fonologia. No exame intraoral observou-se dificuldade de movimentação lingual e em formato de coração devido a inserção fibrosa do freio, sendo observado a Anquiloglossia. Após explicações da alteração, do tratamento, e assinatura do Termo de Consentimento, foi iniciado a cirurgia: antissepsia, anestesia com vasoconstrictor, e em modo contínuo utilizou-se o laser de diodo de alta potência (TW Surgical- MMO®) configurado em 2W de potência, fibra 600µm, no comprimento de onda infravermelho, de modo que as fibras fossem separadas uniformemente e promovesse mobilidade imediata da língua, por fim realizou-se uma sutura em ponto simples com fio reabsorvível. Para o pós-operatório foi prescrito Dipirona em caso de dor, e estabelecido o acompanhamento. No retorno de 7 dias observou-se cicatrização normal e não ingestão do medicamento, em 30 dias foi visto a completa cicatrização e mobilidade sem desconforto, além de relato da paciente de melhoria na condição de relacionamentos sociais, autoestima e deglutição. Conclusão: O resultado apresentado neste artigo ratifica a benefício da escolha do laser em comparação ao convencional, demonstrando que não há sangramento no trans e pós cirúrgico, além de favorecer o processo de reparação tecidual, da redução do tempo cirúrgico, aumento do conforto, e diminuição de uso de medicamento, desta forma associando o laser cirúrgico a melhoria da qualidade de vida.


Introduction: High-power laser therapy has established satisfactory proportions in dentistry and has become the first choice for surgical procedures, bringing quality of life to patients and convenience to surgeons. Objective: To report a clinical case of lingual frenectomy using high-power diode laser, highlighting the benefits of this approach. Case report: A female patient, leucoderma, without systemic alterations, arrived at the Dental School Clinic of the Federal University of Campina Grande with the main complaint of alterations in her phonology. In the intraoral examination, difficulty in lingual movement and a heart-shaped tongue due to fibrous insertion of the frenum were observed, indicating Ankyloglossia. After explanations of the condition, treatment, and signing of the Informed Consent Form, the surgery was initiated: antisepsis, anesthesia with vasoconstrictor, and continuous mode using a high-power diode laser configured at 2W of power, 600µm fiber, at an infrared wavelength, with the aim of uniformly separating the fibers and promoting immediate tongue mobility. Finally, a simple suture was performed using absorbable thread. For the postoperative period, Dipyrone was prescribed for pain relief, and follow-up was established. At the 7-day follow-up, normal healing was observed, and the patient did not require the medication. At 30 days, complete healing and discomfort-free mobility were observed, along with the patient's testimony of improvement in social relationships, self-esteem, and swallowing. Conclusion: The results presented in this article confirm the benefits of choosing laser therapy over conventional methods, demonstrating the absence of bleeding during and after surgery, promoting tissue repair, reducing surgical time, increasing comfort, and decreasing the use of medication. Therefore, the use of surgical laser is associated with an improvement in quality of life.


Introducción: La terapia láser de alta potencia se ha establecido en proporciones satisfactorias en odontología y se ha convertido en la primera elección para procedimientos quirúrgicos, aportando calidad de vida a los pacientes y practicidad a los cirujanos. Objetivo: Relatar un caso clínico de frenectomía lingual con láser de diodo de alta potencia, destacando los beneficios de este procedimiento. Relato del caso: Paciente del sexo femenino, leucoderma, sin alteraciones sistémicas, llegó a la Clínica de la Facultad de Odontología de la Universidad Federal de Campina Grande con la queja principal de alteraciones en su fonología. El examen intraoral reveló dificultad en el movimiento lingual y lengua en forma de corazón debido a la inserción fibrosa del freno, observándose anquiloglosia. Tras explicar la alteración, el tratamiento y firmar el consentimiento, se inició la cirugía: antisepsia, anestesia con vasoconstrictor y uso continuado de un láser de diodo de alta potencia (TW Surgical- MMO®) configurado a 2W de potencia, fibra de 600µm, a longitud de onda infrarroja, para que las fibras se separaran uniformemente y favorecieran la movilidad inmediata de la lengua, y finalmente una sutura de punto único con hilo reabsorbible. En el postoperatorio, se prescribió dipirona en caso de dolor y se estableció un seguimiento. En el seguimiento a los 7 días, se observó una cicatrización normal y no se tomó medicación. A los 30 días, se observó una cicatrización completa y movilidad sin molestias, así como el informe del paciente de una mejora de las relaciones sociales, la autoestima y la deglución. Conclusión: Los resultados presentados en este artículo confirman el beneficio de la elección del láser frente a la cirugía convencional, demostrando que no hay sangrado durante ni después de la cirugía, además de favorecer el proceso de reparación tisular, reducir el tiempo quirúrgico, aumentar el confort y reducir el uso de medicación, asociando así el láser quirúrgico a una mejor calidad de vida.


Subject(s)
Female , Adult , Laser Therapy , Oral Frenectomy , Surgery, Oral , Dentists , Case Reports as Topic , Lingual Frenum
5.
Article | IMSEAR | ID: sea-218502

ABSTRACT

Introduction: The available data regarding scalpel and diode laser incisions wound healing is variable, scarce and needs more clarification especially in normal healthy tissues. Hence, this study was aimed to evaluate clinical and histologic parameters of wound healing with scalpel and diode laser on oral mucosa of Guinea pigs. Materials and Methods: This is an experimental study conducted on four male Guinea pigs. Laser and scalpel incisions were made on the right buccal mucosa of each guinea pig approximately 5mm deep and 10 mm in length and both the incisions were placed 10 mm apart using No#11Bard Parker blades and diode laser (640 wavelength) under general anesthesia. Punch biopsies of both the incisions were obtained and compared for clinical changes such as ease of working, intra-operative bleeding, color and approximation of wound edges and histological changes such as epithelial proliferation, inflammation, angiogenesis, and fibrosis on day 1, 3 and 7. Results: Clinically, scalpel wounds showed better healing than laser wounds although laser incisions provided bloodless surgical field. There was no significant difference in inflammation, angiogenesis and fibrosis between scalpel and diode laser incisions on both day 3 and 7 except for the epithelization which was comparatively early and better in scalpel wounds than the diode laser wounds. Conclusion: Diode lasers provide bloodless surgical field with better visibility than scalpel without any difference in oral mucosal wound healing. Considering the clinical benefits, the diode lasers could be a superior alternative to conventional scalpel technique.

6.
Int. j. odontostomatol. (Print) ; 17(2): 136-141, jun. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1440351

ABSTRACT

This study aimed to carry out an integrative review of the use of diode lasers in the treatment of oral fibrous hyperplasia in order to observe surgical efficacy, healing process, and main microscopic findings. The following databases-PubMed/MEDLINE, Embase, Virtual Health Library, Scopus, Web of Science, and gray literature-were searched without regard to the time of year or language. Diode laser treatment cases described in case reports and case series were included, but those who did not undergo microscopic analysis to confirm the diagnosis or who did not provide postoperative information were excluded. Twelve studies (64 patients) were included. Prevalence was observed for females (68.75 %, n=44). In view of the diagnosis, there was a prevalence of focal fibrous hyperplasia (79.68 %, n=51), followed by inflammatory fibrous hyperplasia (20.31 %, n=13). For surgical removal, a diode laser was used with a wavelength ranging from 808 to 960 nm, in continuous mode, and an average power of 2830 mW. In general, there were no intercurrences in the trans and postoperative periods and wound healing occurred by second intention, with excellent evolution. High-powered diode lasers can be an excellent therapeutic option for oral hyperplastic lesions. Long-term clinical trials should be conducted to determine laser setting parameters in various oral lesions.


El objetivo de este estudio fue realizar una revisión integradora sobre el uso del láser de diodo en el tratamiento de la hiperplasia fibrosa oral, con el fin de visualizar la eficacia quirúrgica, el patrón de cicatrización y el análisis de los principales resultados microscópicos. Se realizó una búsqueda sin restricciones de año e idioma en PubMed/MEDLINE, Embase, Virtual Health Library, Scopus, Web of Science y literatura gris. Se incluyeron reportes de casos y series de casos que brindaron información sobre pacientes diagnosticados con lesiones hiperplásicas orales tratados con láser de diodo, excluyendo aquellos a los que no se les había realizado análisis microscópico para confirmar el diagnóstico, así como aquellos que no brindaron información postoperatoria. Se incluyeron doce estudios (64 pacientes). Se observó prevalencia en el sexo femenino (68,75 %, n=44). Ante el diagnóstico, predominó la hyperplasia fibrosa focal (79,68 %, n=51), seguida de la hiperplasia fibrosa inflamatoria (20,31 %, n=13). Para la remoción quirúrgica se utilizó un láser de diodo con una longitud de onda de 808 a 960 nm, en modo continuo, y una potencia promedio de 2830 mW. En general, no hubo intercurrencias en el trans y postoperatorio y la cicatrización de la herida ocurrió por segunda intención, con excelente evolución. El uso de láseres de diodo de alta potencia puede ser una excelente alternativa terapéutica para las lesiones hiperplásicas orales. Se deben realizar más estudios clínicos a largo plazo para determinar los parámetros de ajuste del láser en diferentes lesiones orales.


Subject(s)
Humans , Oral Surgical Procedures , Lasers, Semiconductor/therapeutic use , Hyperplasia/surgery , Laser Therapy
7.
Article | IMSEAR | ID: sea-218447

ABSTRACT

Purpose: The aim of this trail was to study the efficacy of photobiomodulation (PBM) treatment to reduce the intraocular pressure in subjects with primary open angle glaucoma disease.Methods: Twenty eyes suffering from open angle glaucoma with high IOP level were selected, examined and treated with Thera-RED light diode system. The subjects were divided into two groups (n=10); treated and placebo group respectively; this system provide two lights (red at 660n.m continue and Near IR light micro-pulsed at 850 n.m), the patients received two series of treatment (ten per month within three months between every series of sessions) over five months and follow up taking ocular pressure measurements after every diode delivery session.Results: A significant decrease in IOP has been observed from the first month of the treatment compared to the placebo group (from 22.6mmHg before treatment to 15 mmHg after the tenth session) this amelioration has been also remarked during the second session of treatment (fifth month) to attempt 14.2 mmHg. Conclusion: Thera-RED light diode system treatment shows a significant decrease of IOP and remained to be stable under 14.2 mmHg in all the follow up, which confirm that photobiomodulation help in reducing the intraocular pressure in glaucomatous patients .

8.
Indian J Ophthalmol ; 2023 Jan; 71(1): 140-145
Article | IMSEAR | ID: sea-224781

ABSTRACT

Purpose: To study the safety and efficacy outcomes of Micropulse Transscleral Cyclophotocoagulation (MP?TSCPC) as a primary versus additional therapy in eyes with uncontrolled glaucoma. Methods: This was a prospective, interventional, comparative study. All patients with advanced and refractory glaucoma treated with MP?TSCPC from April 2020 to December 2020 were recruited in this study. Results: A total of 77 eyes of 77 patients were analyzed. Group A (n = 33), included patients with advanced glaucoma at high risk for invasive surgery, who underwent MP?TSCPC as the primary intervention, and group B (n = 44) included patients who had undergone previous surgical intervention and MP?TSCPC was used additionally to control the intraocular pressure (IOP). Mean IOP and mean number of antiglaucoma medications were 34.06 (13.9) mmHg and 3.64 (0.7), respectively, in group A and 35.61 (11.5) mmHg and 3.73 (0.9), respectively, in Group B. Postoperatively, the mean IOP and percentage of IOP reduction were significantly lower at 1, 3, and 6 months, that is, 20.78 (32%), 22.07 (30%), and 19.09 (37%), respectively, in group A and 23.68 (35%), 19.50 (44%), and 19.61 (42%), respectively, in group B, but there was no difference between the groups at all visits. Postoperative need for ocular hypotensive drugs did not differ in group A (P = 0.231); however, it was significantly lower in group B (P = 0.027). Group A had 87%, 77%, and 74% success rates at 1, 3, and 6 months, respectively, whereas group B had 91%, 86%, and 77% success rates at 1, 3, and 6 months, respectively. Postoperative complications and intervention did not reveal any statistical difference between the two groups. Conclusion: MP?TSCPC may be considered as a temporizing measure both as a primary or as an additional intervention to control the IOP in eyes with refractory and advanced glaucoma that have a high risk of vision?threatening complications with invasive surgery.

9.
Chinese Journal of Experimental Ophthalmology ; (12): 688-692, 2023.
Article in Chinese | WPRIM | ID: wpr-990900

ABSTRACT

Central serous chorioretinopathy (CSC) is a primary disease that affects the vision of young and middle-aged people.Its treatment is difficult because of its high incidence and easy recurrence.Currently, the commonly used clinical treatment methods for CSC include photodynamic therapy, traditional laser photocoagulation, subthreshold micropulse laser photocoagulation (SDM), anti-vascular endothelial growth factor therapy, and so on.SDM is a high-frequency, short, subthreshold and selective laser, which is preferred by many clinicians because of its low energy, good safety, small trauma and so on.Different wavelengths of laser can be absorbed by different pigments in the eye, so the therapeutic wavelengths of SDM for different sites of CSC are also different.In SDM treatment, it is necessary to determine the effective treatment range and parameters to avoid undertreatment or overtreatment.In this article, the mechanism of SDM in the treatment of CSC, the difference of SDM under different wavelengths, the selection of treatment site and parameters, the efficacy and safety were reviewed, and the prospect of SDM in the future was envisioned.

10.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 389-399, 2023.
Article in Chinese | WPRIM | ID: wpr-964433

ABSTRACT

Objective@# To explore the effects of red LED light mediated by the Kelch-like ECH-associated protein 1-nuclear factor erythroid 2-related factor 2/heme oxygenase-1 (KEAP1-NRF2/HO-1) pathway on osteogenic differentiation and oxidative stress damage of human periodontal ligament stem cells (hPDLSCs) induced by high glucose, which provides a basis for the application of red light-emitting diode (LED) light in cell antioxidative damage.@*Methods@#hPDLSCs were identified by flow cytometric analysis, alkaline phosphatase (ALP) staining and Alizarin red-S staining; hPDLSCs were pretreated in a high glucose environment for 48 hours and irradiated with 1, 3, or 5 J/cm2 red LED light. A CCK-8 assay was performed to choose the radiant exposure that had the strongest effect on promoting the cell proliferation rate for subsequent experiments. hPDLSCs were divided into a control group, a high glucose group and a high glucose+light exposure group. ALP staining, ALP activity, Alizarin red-S staining and quantitative calcified nodules were used to detect the osteogenic differentiation of hPDLSCs; qRT-PCR and Western blot were used to detect the gene and protein expression levels of ALP, runt-related transcription factor 2 (RUNX2) and osterix (OSX); the relative mRNA expression levels of antioxidant enzyme-related genes superoxide dismutase 2 (SOD2) and catalase (CAT) in hPDLSCs were detected by qRT-PCR; reactive oxygen species (ROS) levels were detected by fluorescence microscopy and flow cytometry; the tumor necrosis factor-α (TNF-α) and interleukin-1β (IL-1β) levels in cell supernatants were detected by ELISA; the NRF2-specific inhibitor ML385 was used to inhibit the NRF2 pathway; ALP staining and ALP activity were used to detect the markers of early osteogenic differentiation; qRT-PCR was used to detect the gene expression of ALP, RUNX2 and OSX; and the protein expression levels of KEAP1, NRF2 and HO-1 were detected by Western blot.@*Results @# Identified, and irradiant exposure of 5 J/cm2 was chosen for subsequent experiments. Red LED light irradiation (5 J/cm2) improved the osteogenic differentiation of hPDLSCs induced by high glucose (P<0.05), increased the mRNA and protein levels of ALP, RUNX2 and OSX (P<0.05), upregulated the mRNA expression levels of SOD2 and CAT (P<0.05), reduced the levels of ROS (P<0.05), and reduced TNF-α and IL-1β levels in the cell supernatants (P<0.05). When ML385 was added to inhibit the NRF2 pathway, the ALP activity of cells was decreased (P<0.05); the gene expression levels of ALP, RUNX2 and OSX were downregulated (P<0.05); the protein level of KEAP1 was upregulated (P<0.05); and the protein levels of NRF2 and HO-1 were downregulated (P<0.05)@*Conclusion@#Red LED light may promote the proliferation and osteoblastic differentiation of hPDLSCs induced by high glucose through the KEAP1-NRF2/HO-1 pathway and reduce the oxidative stress damage to hPDLSCs induced by high glucose.

11.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 701-711, 2023.
Article in Chinese | WPRIM | ID: wpr-980080

ABSTRACT

Objective @#To study the effect of light-emitting diode (LED) red light on the osteogenic/odontogenic differentiation of human dental pulp stem cells (hDPSCs) and its mechanism were discussed. @*Methods@#This study has been reviewed and approved by the Ethics Committee. hDPSCs were cultured by tissue block enzyme digestion. The proliferative capacity of hDPSCs was detected by the CCK-8 at days 1, 3, 5 and 7 under stimulation with 0, 1, 5 and 10 μg/mL lipopolysaccharide (LPS), and the LPS stimulatory concentration was screened. The CG group (mineralization induction), LPS+CG group, and LPS+CG+ (2, 4, 6, 8, and 10 J/cm2) LED red light groups were set. On day 7, alkaline phosphatase (ALP) staining and ALP activity were determined. Relative expression levels of the ALP, osterix (OSX), dentin matrix protein-1 (DMP-1) and dentin sialophosphoprotein (DSPP) genes were measured by qRT-PCR. On day 21, alizarin red staining and calcium nodule quantitative determination were performed to screen the best light energy. The LPS+CG group and LPS+CG+LED group (optimal energy) were set up, and the secretion and expression levels of tumor necrosis factor-α (TNF-α) and interleukin-1β (IL-1β) were detected by ELISAs on days 1, 3, 5 and 7. The relative expression levels of the extracellular regulated protein kinases 1/2 (ERK1/2), p38, c-Jun N-terminal kinase (JNK), and extracellular regulated protein kinases 5 (ERK5) proteins and their phosphorylated proteins in the MAPK signaling pathway were detected by Western blots. After the pathway was blocked, the relative expression levels of the ALP, OSX, DMP-1, and DSPP proteins after LED red light irradiation on day 7 were detected by Western blots.@*Results@# CCK-8 assays showed that the proliferation of hDPSCs induced by 10 μg/mL LPS was lower than that of the 0, 1, and 5 μg/mL groups on the 5th and 7th days (P<0.05), and 10 μg/mL was selected as the LPS stimulatory concentration in the follow-up experiment. ALP staining, ALP activity, gene expression levels of ALP, OSX, DMP-1 and DSPP and calcium nodule quantification in the LPS+CG+4 J/cm2 group were higher than those in the other treatment groups (P<0.05). 4 J/cm2 LED red light had the strongest ability to promote osteogenic/odontogenic differentiation and was used as the LED light energy density in subsequent experiments. ELISA showed that the secretion and expression levels of TNF-α and IL-1β in the LPS+CG+LED group were lower than those in the LPS+CG group on the 5th and 7th days (P<0.05). Western blot analysis showed that 4 J/cm2 LED red light promoted the expression levels of the p-ERK1/2, p-p38, p-JNK and p-ERK5 proteins. After the MAPK pathway was blocked, the expression levels of the ALP, OSX, DMP-1, and DSPP proteins in the LPS+CG+LED+U0126 (ERK1/2 inhibitor), SP600125 (JNK inhibitor), and BIX02189 (ERK5 inhibitor) groups were lower than those in the LPS+CG+LED group (P<0.001). The protein expression levels of ALP, OSX and DMP-1 in the LPS+CG+LED+SB203580 (p38 inhibitor) group were not significantly different from those in the LPS+CG+LED group (P>0.05).@*Conclusion@#In inflammatory conditions, LED red light promotes osteogenic/odontogenic differentiation of hDPSCs. This effect may be attributed to enhancement of the ERK1/2, JNK, and ERK5 signaling pathways, which reduces the production of the inflammatory cytokines TNF-α and IL-1β.

12.
STOMATOLOGY ; (12): 252-255, 2023.
Article in Chinese | WPRIM | ID: wpr-979364

ABSTRACT

@#Laser therapy has become an important means of treating peri-implant diseases, and diode laser shows unique advantages in the adjuvant therapy of peri-implant diseases due to its excellent biological regulation, sterilization effect and biological safety. This article reviews the principle, characteristics, safety, biological effects of and clinical research on diode laser, in order to provide reference for its clinical application in the treatment of peri-implant diseases.

13.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 586-591, 2023.
Article in Chinese | WPRIM | ID: wpr-972231

ABSTRACT

@#Chronic periodontitis is a chronic inflammatory disease caused by plaque microorganisms, and removal of plaque and calculus is the gold standard for nonsurgical periodontal treatment. However, complete debridement is difficult, especially in some complex anatomical sites. Excessive scaling may result in the loss of healthy cementum and lead to dental hypersensitivity. Studies have shown that a diode laser can exhibit the best performance in an environment with blood because its wavelengths (630-1 064 nm) are close to the absorption peaks of heme and melanin and they have broad application prospects in the oral field. In nonsurgical periodontal treatment, diode lasers have three treatment modes: soft diode laser, antimicrobial photodynamic therapy and low-level laser therapy, which can be used alone or in combination. Although diode lasers cannot replace mechanical treatment to remove calculus, they can remove infected periodontal pocket epithelium, change the microcirculation to promote wound healing, reduce bleeding and relieve pain through photothermal effects and biological stimulation. The effect of diode laser treatment depends on the treatment dose. It is necessary to precisely control the output intensity and control the irradiation time to avoid thermal damage to the tissue. In the future, extensive research at the molecular level is needed to reveal the tissue response. At the same time, more high-quality, large-sample randomized controlled trials are needed to standardize the use of lasers for different stages and grades of periodontitis.

14.
Chinese Journal of Dermatology ; (12): 325-329, 2023.
Article in Chinese | WPRIM | ID: wpr-994481

ABSTRACT

Objective:To analyze the willingness-to-pay (WTP) for the treatment of acute facial inflammatory dermatoses with red and yellow light from light-emitting diodes (LEDs), and to evaluate their cost-effectiveness.Methods:A questionnaire survey was conducted on outpatients with or without acute facial inflammatory dermatoses, which mainly manifested as erythema and swelling, in Department of Dermatology, Xiangya Hospital from August 2019 to June 2020. The WTP for the treatment of acute facial inflammatory dermatoses of varying severity with red and yellow light from LEDs were investigated, clinical data on the prevalence of facial skin diseases, previous medical visits and quality of life were collected, and a benefit-cost analysis was conducted. Logistic regression analysis was conducted to investigate factors influencing the patients′ WTP for the LED treatment.Results:The median WTP of the subjects was 200, 300 and 300 RMB yuan for 1-session treatment of three cases of acute facial inflammatory dermatoses of increasing severity assumed to require 1-, 3-, and 5-session LED treatments respectively, and the WTP for 1-session treatment of case 2 and case 3 was higher than the cost of 1-session LED treatment (217 RMB yuan). The subjects with high family incomes (≥ 100 000 RMB yuan/year) were significantly more willing to pay for the treatment than those with low family incomes (< 100 000 RMB yuan/year) (case 1: 40.46% vs. 27.50%, χ2 = 7.00, P = 0.008; case 2: 60.69% vs. 44.5%, χ2 = 9.75, P = 0.002; case 3: 51.20% vs. 48.8%, χ2 = 6.54, P = 0.011), and the subjects who never suffered from facial inflammatory dermatoses were significantly more willing to pay for the treatment than those who ever suffered (case 1: 35.49% vs. 28.82%, χ2 = 1.56, P = 0.212; case 2: 56.10% vs. 42.34%, χ2 = 5.92, P = 0.015; case 3: 68.32% vs. 56.75%, χ2 = 4.58, P = 0.032). No significant difference in the WTP was observed among patients with different facial dermatoses, different degrees of impairment on quality of life, or different treatment experience (all P>0.05) . Conclusion:The cost of red and yellow light from LEDs for the treatment of acute facial inflammatory dermatoses manifesting as erythema and swelling was highly acceptable in this population, and it was worthy of clinical promotion.

15.
Rev. odontol. UNESP (Online) ; 52: e20230028, 2023. tab
Article in English | LILACS, BBO | ID: biblio-1530302

ABSTRACT

Introduction: the use of light emitting diodes (LED) in domestic and public vias have increased in the last 20 years. In addition, the LED light has been used as a light source for medical applications. Objective: since humans are increasingly exposed to LEDs, there is an urgency to investigate the possible biological effects on tissues caused by this exposure. So, researchers have been focused their investigations in the application of this light in the health field. Material and method: in this review, a search in important databases was performed on the biological effects caused after application of different LED light protocols in in vitro and in vivo studies. Result: although most published papers have shown positive results, some of them reported negative biological effects of light LEDs technology on humans' cells/tissues. Conclusion: therefore, the comprehension of the biological effects caused by light LEDs will provide a better assessment of the risks involved using this technology.


Introdução: o uso de diodos emissores de luz ("LED") em vias domésticas e públicas tem aumentado nos últimos 20 anos. Além disso, a luz LED tem sido usada para aplicações médicas. Objetivo: pelo fato de seres humanos estarem cada vez mais expostos aos LEDs, há urgência em investigar os possíveis efeitos biológicos nos tecidos causados por esta exposição. Assim, pesquisadores têm focado suas investigações no uso desta luz na área da saúde. Material e método: nesta revisão foi realizada uma pesquisa em bancos de dados conceituados sobre os efeitos biológicos causados após aplicação de diferentes protocolos de luz LED em estudos in vitro e in vivo. Resultado: embora a maioria dos artigos publicados tenham mostrado resultados positivos, alguns deles relataram efeitos biológicos negativos da tecnologia de LEDs nas células/tecidos humanos. Conclusão: portanto, a compreensão dos efeitos biológicos causados pela luz LED proporcionará uma melhor avaliação dos riscos envolvidos no uso desta tecnologia.


Subject(s)
Phototherapy , Tissues , In Vitro Techniques , Catchment Area, Health , Cells , Lasers, Semiconductor , Curing Lights, Dental
16.
Article | IMSEAR | ID: sea-218413

ABSTRACT

Purpose: To derive and provide, for the first time, comprehensive analytic formulas for scleral softening volume efficacy (SVE) for accommodative gain (AG) via the increased space between ciliary body and lens (SCL) and mobility of the posterior vitreous zonules (PVZ).Study Design: To increase the AG of presbyopic eye by a new procedure, laser scleral softening (LSS).Place and Duration of Study: New Taipei City, Taiwan, between June 2022 and July 2022.Methodology: The SVE is calculated based on the time and spatial integral of the scleral temperature profiles, T(z,t), solutions of a heat diffusion equation. Analytic formulas for SVE is derived based on the covered area given by a triangle area. The SVE of a 3-D model is governed by the "volume" covered by the laser beam, or its spot size area, the effective penetration depth (z"), which is an increasing function of laser dose, but a decreasing function of the absorption coefficient (A), due to the Beer's law of laser intensity, I(z)=I0exp(-Az). The efficacy depth-range (dZ) and time-ranges (dT) are defined for efficient softening with T(z,t)>T*, where T* is the scleral softening threshold temperature.Results: The accommodative gain is proportional to the 3-D SVE given by: SEV(3D) = SEV(1D) x laser beam spot (2-D area) x total number of spots (N) acting on the sclera, which is proportional to the efficacy ranges dZ and dT, in which dZ is an increasing of laser irradiation time, whereas dT is a decreasing function of depth. Softening of the scleral tissue after a thermal laser leading to the increase of PVZ mobility and SCL. However, the actual relation of SVE and the PVZ and SCL changes require measured data.Conclusion: Safety and efficacy of scleral softening for presbyopia treatment depend upon the laser parameters (intensity, dose, spot size, wavelength) and the effective depths. The SVE is proportional to the efficacy depth-range (dZ) and time-range (dT), in which dZ is an increasing of laser irradiation time and dT is a decreasing function of depth. The AG is proportional to the SVE(in 3-D).

17.
Article | IMSEAR | ID: sea-218411

ABSTRACT

Purpose: To derive and provide analytic formulas and proposed protocol for accommodative gain of presbyopia eyes via laser scleral softening, which causes increased space between ciliary body and lens (SCL) and mobility of the posterior vitreal zonules (PVZ).Study Design: To increase the accommodation of presbyopia by laser scleral heating/softening.Place and Duration of Study: New Taipei City, Taiwan, between April 2022 and June 2022.Purpose: To analyze the safety and efficacy of presbyopia treatment via scleral softening.Methodology: The scleral softening efficacy is calculated based on the rate equation of scleral tissue with a rate coefficient given by an Arrhenius formula, Temperature spatial and temporal profiles are given by the numerical solutions of a heat diffusion equation with a volume heating source. Various effective depths including tissue damage depth, temperature penetration depth and conversion depth, governed by tissue absorption coefficient, light intensity and dose (or irradiation time), and the related threshold values, are introduced in replacing the conventional penetration depth based on a Beer's law.Results: Given the the temperature spatial and temporal profiles, scleral softening efficacy can be calculated. Scleral surface damage can be prevented by cooling window. The suggested protocol for scleral softening treatments include: a diode laser at about 1.45 to 1.5 祄 or about 1.86 to1.9 祄, or about 2.0 to 2.15 祄, wavelength (with absorption coefficient about 20 to 100 cm-1); laser power about 0.2 to 0.8 W per spot, having a total of 4 to 16 spots; and irradiation time of 100 to 600 ms. Results of corneal thermal shrinkage are demonstrated by the topography changes of pig eyes, in which the scleral softening does not affect the corneal shapes. The accommodative gain is proportional to the softening efficacy (Seff) of the scleral tissue after a thermal laser leading to the increase of PVZ mobility and SCL. However, the actual relation of Seff and the PVZ and SCL changes require measured data.Conclusion: Safety and efficacy of scleral softening for presbyopia treatment depend upon the laser parameters (intensity, dose, spot size, wavelength) and the effective depths. By choosing the laser treated areas, a dual function treatment using scleral softening for presbyopia, and cornea stromal shrinkage for hyperopia is proposed and demonstrated by topography of pig eyes.

18.
Article | IMSEAR | ID: sea-218407

ABSTRACT

Purpose: To analyze the safety and efficacy of corneal photovitrification (CPV) for improved visions of age-related macular degeneration (AMD) eyes.Study Design: Using CPV for improved visions of AMD eyes.Place and Duration of Study: New Taipei City, Taiwan, and Austin, TX, USA; between April, 2022 and June, 2022.Methodology: The CPV efficacy is calculated based on the rate equation given by dM/dt=-k(t) M(t), where M(t) is the PCV-treated corneal stroma; and k(t) is the rate coefficient given by an Arrhenius formula, k(t) = A0 exp[?Ea/(RT(t,z)], where t and z are the laser irradiation time and depth of the cornea stroma; Ea is the activation energy and R is the gas constant. The temperature spatial and temporal profiles are given by the numerical solutions of a heat diffusion equation with a volume heating source. Various effective depths including the tissue damage depth, temperature penetration depth and conversion depth, governed by the tissue absorption coefficient, light intensity and dose (or irradiation time), and the related threshold values, are introduced in replacing the conventional penetration depth based on a Beer's law.Results: The suggested protocol for CPV treatments include: a diode laser at about 2 祄 wavelength (with absorption coefficient about 100 cm-1). The laser dose is about 25 J/cm2/spot and irradiation time of 150 ms.Conclusion: The efficacy of CPV may be predicted/calculated by our modeling based on rate equation and the corneal stroma temperature rise due to laser heating. The preferred retinal locus (PRL) movement observed post-CPV is caused mainly by neuroadaptation.

19.
Article | IMSEAR | ID: sea-222180

ABSTRACT

Oral lichen planus (OLP) is a chronic T-cell mediated inflammatory disease of unknown etiology. Hence, no gold standard treatment modalities are available. Due to therapeutic challenges offered by conventional therapy, there is a need for effective alternate treatment with minimal side effects. The development of lasers has brought light to the treatment of obstinate OLP. Three cases of male patients in the age group 30–40 years complaining of a burning sensation in the mouth have been mentioned. Clinical and histopathological investigations showed typical findings of OLP. The treatment was started with conventional therapy of corticosteroids. The symptoms were assessed on the visual analog scale (VAS) and showed marked reduction but without complete alleviation. Hence, ablation of the lesion using a 980 nm soft-tissue diode laser was planned. The outcome of the treatment was successful, VAS 0 and no recurrence occurred in 11 months follow-up. The results of a 980 nm diode laser for the treatment of OLP are satisfactory and should be considered as a treatment alternative to conventional remedies

20.
Rev. Odontol. Araçatuba (Impr.) ; 43(1): 41-44, jan.-abr. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1361662

ABSTRACT

Background: Glanzmann thrombasthenia (GT) is a rare autosomal recessive disorder characterized by platelet function impairment. Considering that the oral cavity is highly vascularized and performing some local hemostatic maneuvers may be difficult, GT patients are at high risk for hemorrhage related to invasive oral procedures. This study aimed to present an alternative method for periodontal surgery in a young GT patient. Case Report: A 15-year-old female GT patient with a recent history of excessive bleeding following dental surgeries was referred to a public dental center, presenting gingival hyperplasia. The procedure was performed using a high-power laser (HPL), and except for local anesthesia with epinephrine, no further hemostatic agent was necessary. Conclusion: According to the case, the HPL seems to be an efficient tool for preventing perioperative bleeding in GT patients submitted to minor oral surgeries(AU)


Introdução: A trombastenia de Glanzmann (TG) é uma doença autossômica recessiva rara caracterizada por comprometimento da função plaquetária. Tendo em vista que a cavidade oral é altamente vascularizada e a realização de algumas manobras hemostáticas locais pode ser difícil, pacientes com TG apresentam alto risco de hemorragia relacionada a procedimentos orais invasivos. Este artigo teve como objetivo apresentar uma técnica alternativa para cirurgia periodontal em um paciente jovem com TG. Relato de Caso: Paciente com TG, sexo feminino, 15 anos, com história recente de sangramento excessivo relacionado a cirurgias odontológicas prévias, foi encaminhada a um centro odontológico público apresentando hiperplasia gengival. O procedimento de remoção foi realizado com laser de alta potência e, com exceção da anestesia local com epinefrina, nenhum outro agente hemostático foi necessário. Conclusão: De acordo com o caso, o laser de alta potência parece ser uma ferramenta eficiente na prevenção de sangramento perioperatório em pacientes com TG submetidos a pequenas cirurgias orais(AU)


Subject(s)
Humans , Female , Adolescent , Surgery, Oral , Thrombasthenia , Blood Coagulation Disorders , Laser Therapy , Lasers, Semiconductor , Gingival Hyperplasia
SELECTION OF CITATIONS
SEARCH DETAIL