Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
China Journal of Endoscopy ; (12): 17-22, 2018.
Article in Chinese | WPRIM | ID: wpr-702920

ABSTRACT

Objective To compare the clinical effect of nasal intubation with domestic video intubationscope and Macintosh direct laryngoscope. Methods One hundred patients scheduled for oro-maxillo-facial operation, American Society of Anesthesiologists (ASA) grade I or II, aged 19 ~ 67 years, were randomly divided into the domestic video intubationscope group (group V) and the Macintosh direct laryngoscope group (group M), with 50 cases in each group. Nasal intubation was respectively performed with domestic video intubationscope (Group V) and Macintosh direct laryngoscope (group M). Cormark-Lehane grade (C-L classification), tracheal intubation time, first-time intubation success rate and tracheal intubation complications were recorded.Mean arterial pressure (MAP) and heart rate (HR) of before induction of anesthesia (T0), after induction of anesthesia (T1), at glottic exposure (T2), at intubation (T3), 1 min after intubation (T4) and 3 min after intubation (T5) were recorded. Results C-L classification in group V was significantly lower than that in group M (P < 0.05), intubation time in group V was significantly shorter than that in group M (P < 0.05), first-time intubation success rate in group V was significantly higher than that in group M (P < 0.05). Compared with T1, MAP was significantly higher at T3~ T4and HR was significantly faster at T3in group V, MAP was significantly higher at T2~ T4and HR was significantly faster at T2~ T3in group M (P < 0.05). Compared with group M, MAP and HR in group V were significantly lower at T2~ T4 (P < 0.05). The incidence of tracheal intubation complications in group V was significantly lower than that in group M (P < 0.05). Conclusions Compared with Macintosh direct laryngoscope,domestic video intubationscope in nasal intubation is better in glottic exposure,it could shorten tracheal intubation time ,increase first-time intubation success rate, maintain stable hemodynamics, has fewer tracheal intubation complications and is worthy of clinical application.

2.
Chinese Journal of Medical Education Research ; (12): 1260-1263, 2017.
Article in Chinese | WPRIM | ID: wpr-665621

ABSTRACT

Tracheal intubation is one of the most important emergency techniques, and it is a key and difficult point in advanced life support training for cardiopulmonary resuscitation. Our treatment is trying to combine standard video with visual laryngoscopes for tracheal intubation teaching. Firstly, the students watch the standard video. Then, the teacher shows how to perform a tracheal intubation by visual laryngo-scope. Finally, the students practice the intubation process on the simulation device. In this way, the teach-ing process is more intuitive, easier to be mastered, more normalized and repeatable. This method is worth to be promoted.

3.
Rev. bras. anestesiol ; 66(4): 363-368, tab, graf
Article in English | LILACS | ID: lil-787615

ABSTRACT

Abstract Background and objective: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScopeTM visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients. Methods: Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded. Results: The results showed success rates of 74.5% in the GlideScopeTM Group as compared to 58.3% in the MacIntosh Group (p = 0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2 ± 9.3 s as compared to Group B, with a duration of 18.9 ± 13.0 s (p = 0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p = 0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking. Conclusion: This study showed that using the GlideScopeTM to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.


Resumo Justificativa e objetivo: Este foi um estudo clínico prospectivo e randômico para comparar a taxa de sucesso da inserção de sonda nasogástrica (NG) com as técnicas de visibilização guiada pelo laringoscópio GlideScope® versus guiada pelo laringoscópio MacIntosh em pacientes anestesiados e intubados. Métodos: Foram recrutados 96, ASA I ou II, entre 18-70 anos, e divididos randomicamente em dois grupos, com uma ou outra técnica. Foi calculado o tempo transcorrido desde a inserção da sonda NG, da narina até a inserção do comprimento calculado da sonda. A taxa de sucesso de inserção da sonda NG foi avaliada quanto à inserção bem-sucedida na primeira tentativa. As complicações associadas às técnicas de inserção foram registradas. Resultados: Os resultados mostraram taxas de sucesso de 74,5% para o grupo GlideScope® em comparação com 58,3% para o grupo MacIntosh (p = 0,10). Para as tentativas que falharam, a sonda NG foi inserida com sucesso em todos os casos, com as técnicas de resgate. A duração da primeira tentativa para ambas as técnicas não foi estatisticamente significativa: 17,2 ± 9,3 segundos no Grupo A e 18,9 ± 13,0 segundos no Grupo B (p = 0,57). No total, 33 pacientes desenvolveram complicações durante a inserção da sonda NG: 39,4% no Grupo A e 60,6% no Grupo B (p = 0,15). As complicações mais comuns ocorridas foram enrolamento, seguido de sangramento e dobradura. Conclusão: Este estudo mostrou que o uso do GlideScope® para facilitar a inserção de sonda nasogástrica foi comparável ao uso do laringoscópio MacIntosh quanto à taxa de sucesso de inserção e às complicações.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Young Adult , Laryngoscopes , Intubation, Gastrointestinal/instrumentation , Intubation, Gastrointestinal/methods , Intubation, Intratracheal , Laryngoscopy/methods , Time Factors , Single-Blind Method , Prospective Studies , Equipment Design , Anesthesia , Middle Aged , Nasal Cavity
4.
China Journal of Endoscopy ; (12): 25-29, 2016.
Article in Chinese | WPRIM | ID: wpr-621260

ABSTRACT

Objective To compare the clinical efficacy of the video intubationscope and Macintosh direct laryngoscope in simulated cervical spine immobilization. Methods Sixty patients, ASA Ⅰ or Ⅱ , between 19 and 68 years old, underwent general anesthesia requiring oro-tracheal intubation, were randomly assigned to undergo intubation using video intubationscope (group V) or Macintosh direct laryngoscope (group M), 30 cases in each. Each patient was provided mannal in-line axial stabilization of the head and neck by an experienced assistant. The following data were recorded and analyzed: glottic exposure time, Cormark-Lehane grade (C-L classification), tracheal intubation time, total intubation attempts, manoeuvre needed to aid tracheal intubation, failure for tracheal intubation, one-time success rate of tracheal intubation and total success rate of tracheal intubation, mean arterial pressure (MAP) and heart rate (HR) before induction of anesthesia, before intubation, at glottic exposure, at intubation, 1 and 3 min after intubation, and complications. Results Compared with group M, better glottic exposure view (C-L classification) was achieved in group V (P 0.05) and were significantly increased at T3~T5 (P < 0.05); compared with group M, MAP at T2~T4 in group V were significantly lower (P < 0.05). Compared with T1, HR in group V were no significantly changed at T2~T5, HR in group M were significantly increased at T2~T4 (P < 0.05), and significantly higher than that in group V at the same time point (P < 0.05). Conclusion Compared with Macintosh direct laryngoscopy in patients with cervical spine immobilization, Video intubationscope could provide better view of glottic exposure, decrease the difficulty of intubation and increase the success rate of intubation, have less complications and influence on patient’s hemodynamics.

5.
Academic Journal of Second Military Medical University ; (12): 954-957, 2010.
Article in Chinese | WPRIM | ID: wpr-840792

ABSTRACT

Objective: To compare the hemodynamic responses to orotracheal intubation between Truview™ EVO2 optic laryngoscope and Macintosh direct laryngoscope. Methods: Eighty adult patients (ASA physical status I-II, aged 18-65 years) scheduled for elective surgery under general anesthesia requiring orotracheal intubation were randomly divided into 2 groups (n=40 each): T group and M group. After standard intravenous anesthetic induction, orotracheal intubation was performed with Truview™ EVO2 optic laryngoscope or Macintosh direct laryngoscope. Non-invasive heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and SpO2 were recorded before(T0) and after anesthetic induction (T1), at intubation (T2), 1 minutes (T3), 3 minutes (T4) and 5 minute after intubation (T5). The laryngeal exposure period and intubation period were also recorded. Statistical analysis was performed using the Statistical Package for Social Sciences (SPSS) Version 13.0. Results: Except for HR at intubation (T2), there was no significant difference in the hemodynamic data at any other time points between the two groups. There was no significant difference in the laryngeal exposure period between the two groups. The intubation time in the T group was significantly longer than that in the M group (P< 0.05), but no more than 60 seconds. Conclusion: The hemodynamic responses produced by orotracheal intubation are similar between Truview™ EVO2 optic laryngoscope and Macintosh direct laryngoscope.

6.
Korean Journal of Anesthesiology ; : 284-289, 2009.
Article in Korean | WPRIM | ID: wpr-79318

ABSTRACT

BACKGROUND: Airwayscope (AWS), which has been used successfully for difficult airway in general anesthesia, has been anticipated that hemodynamic response to tracheal intubation in the difficult airway may be attenuated. Also, there is a series of reports demonstrating the successful use of lightwand to open the difficult airway. Thus, we decided to conduct a survey to compare AWS to lightwand and to direct laryngoscopy of cardiovascular response to tracheal intubation. METHODS: Of 64 healthy patients without cardiovascular disease, 22, 21, 21 patients were randomly assigned to AWS group, lightwand group and direct laryngoscope group. After induction of general anesthesia, intubation was performed with manual in-line neck stabilization. During laryngoscopy, a modified Cormack-Lehane grade was assessed and time to intubation was measured. Systolic arterial pressure (SAP) and heart rate (HR) were recorded at the following timepoints: baseline, just before intubation, 1 min, 2 min, 3 min, 4 min and 5 min after intubation. RESULTS: There were no significant differences between the 3 groups in SAP, HR (P > 0.05). However modified Cormack-Lehane grade of all patients in the AWS group was I, while that in direct laryngoscope group was IIB or III. In addition, the mean time to intubation of the direct laryngoscope group was significantly longer than that of the AWS and lightwand (P < 0.05). CONCLUSIONS: In the difficult airway, AWS was very effective in improving laryngeal view and decreasing time to intubation compared to direct laryngoscopey. In addition, lightwand reduced the time to intubation. However we could not find any significant difference in hemodynamic response to tracheal intubation among the 3 groups.


Subject(s)
Humans , Anesthesia, General , Arterial Pressure , Cardiovascular Diseases , Heart Rate , Hemodynamics , Intubation , Laryngoscopes , Laryngoscopy , Neck
7.
Academic Journal of Second Military Medical University ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-564078

ABSTRACT

Objective:To compare the hemodynamic responses to orotracheal intubation between TruviewTM EVO2 optic laryngoscope and Macintosh direct laryngoscope.Methods: Eighty adult patients(ASA physical status Ⅰ-Ⅱ,aged 18-65 years) scheduled for elective surgery under general anesthesia requiring orotracheal intubation were randomly divided into 2 groups(n=40 each):T group and M group.After standard intravenous anesthetic induction,orotracheal intubation was performed with TruviewTM EVO2 optic laryngoscope or Macintosh direct laryngoscope.Non-invasive heart rate(HR),systolic blood pressure(SBP),diastolic blood pressure(DBP),mean arterial pressure(MAP) and SpO2 were recorded before(T0) and after anesthetic induction(T1),at intubation(T2),1 minutes(T3),3 minutes(T4) and 5 minute after intubation(T5).The laryngeal exposure period and intubation period were also recorded.Statistical analysis was performed using the Statistical Package for Social Sciences(SPSS) Version 13.0.Results: Except for HR at intubation(T2),there was no significant difference in the hemodynamic data at any other time points between the two groups.There was no significant difference in the laryngeal exposure period between the two groups.The intubation time in the T group was significantly longer than that in the M group(P

8.
Korean Journal of Anesthesiology ; : 949-954, 1999.
Article in Korean | WPRIM | ID: wpr-138239

ABSTRACT

BACKGROUND: Direct laryngoscope may be less useful under conditions of limited visualization. Light wand is a lighted stylet to transilluminate neck tissues allowing intubation without visualization. Thus, difficult intubation due to anatomy can be overcome. For comparison of light wand and direct laryngoscope, we checked time to intubation (TTI), success rate, relation of TTI and thyromental distance (TMD), and change of blood pressure and heart rate after intubation. METHODS: We selected and randomly allocated sixty adults to direct layngoscope group (D) and light wand group (L). Without premedication, propofol and vecuronium were injected for intubation. Time to intubation was measured from the time of grasping direct laryngoscope or light wand until the time of inserting endotracheal tube into trachea. We checked the change of blood pressure and heart rate after intubation, and studied the correlation of TTI and TMD. RESULTS: TTI was 16.5 sec (6.53~115.3 sec) for group D and 11.8 sec (4.31~36.0 sec) for group L. There was no significant difference between the groups. The rise of blood pressure and heart rate was less with light wand. There was a correlation of [TTI]=1248- 388[TMD]-30[TMD]2 in group L patients whose TMD is less than 7 cm. CONCLUSION: Compared with direct laryngoscope, light wand is as easy to use and can be more effective especially for patients whose anatomy may make intubation difficult or whose cardiovascular system is unstable.


Subject(s)
Adult , Humans , Blood Pressure , Cardiovascular System , Hand Strength , Heart Rate , Heart , Intubation , Laryngoscopes , Neck , Premedication , Propofol , Trachea , Vecuronium Bromide
9.
Korean Journal of Anesthesiology ; : 949-954, 1999.
Article in Korean | WPRIM | ID: wpr-138238

ABSTRACT

BACKGROUND: Direct laryngoscope may be less useful under conditions of limited visualization. Light wand is a lighted stylet to transilluminate neck tissues allowing intubation without visualization. Thus, difficult intubation due to anatomy can be overcome. For comparison of light wand and direct laryngoscope, we checked time to intubation (TTI), success rate, relation of TTI and thyromental distance (TMD), and change of blood pressure and heart rate after intubation. METHODS: We selected and randomly allocated sixty adults to direct layngoscope group (D) and light wand group (L). Without premedication, propofol and vecuronium were injected for intubation. Time to intubation was measured from the time of grasping direct laryngoscope or light wand until the time of inserting endotracheal tube into trachea. We checked the change of blood pressure and heart rate after intubation, and studied the correlation of TTI and TMD. RESULTS: TTI was 16.5 sec (6.53~115.3 sec) for group D and 11.8 sec (4.31~36.0 sec) for group L. There was no significant difference between the groups. The rise of blood pressure and heart rate was less with light wand. There was a correlation of [TTI]=1248- 388[TMD]-30[TMD]2 in group L patients whose TMD is less than 7 cm. CONCLUSION: Compared with direct laryngoscope, light wand is as easy to use and can be more effective especially for patients whose anatomy may make intubation difficult or whose cardiovascular system is unstable.


Subject(s)
Adult , Humans , Blood Pressure , Cardiovascular System , Hand Strength , Heart Rate , Heart , Intubation , Laryngoscopes , Neck , Premedication , Propofol , Trachea , Vecuronium Bromide
SELECTION OF CITATIONS
SEARCH DETAIL