Chinese Journal of Radiological Medicine and Protection ; (12): 456-460, 2017.
Article in Chinese | WPRIM | ID: wpr-621000

ABSTRACT

Objective To establish a method for reducing the dose to the eye lens of interventional staff,and provide the data basis for improving radiological protection measures.Methods One piece of interventional equipment coupled with conventional auxiliary protective devices and two types of common neural interventional procedures were selected to monitor 46 and 35 procedures before and after the device modification.The doses to the eye lens of staff were measured with direct-reading dosimeters for analysis of dose trends.Results After modification of the devices,the average dose to the left eye lens decreased from (9.71 ±10.86) to (3.23 ±5.59) μSv for the first operator,from (9.51 ± 12.34) to (0.68 ± 0.78) μSv for the second in cerebral angiography;whereas the dose decreased from (14.83 ± 19.13) to (4.17±4.59) for the first operator and from (14.12±21.76) to (1.23 ±1.57)μSv for the second in embolization procedure,respectively.The left eye lens doses measured before and after the modification showed significant difference (U =-2.760,-2.467,-1.967,-2.655,P <0.05).Conclusions The modification of the auxiliary radiological protective devices may effectively reduce the dose to the eye lens dose.This method was shown to be feasible for the improvement of radiological protection of interventional staff.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 929-934, 2016.
Article in Chinese | WPRIM | ID: wpr-505429

ABSTRACT

Objective To establish the methods for measuring the dose to occupational staff's eye lens in interventional procedures with direct-reading dosimeters,and to realize the real-time monitoring of eye lens dose and warning for high dose rate,thus providing the scientific basis of the staff radiological protection in interventional procedures.Methods Direct-reading dosimeters were calibrated with personal dose equivalent HP (3).The eye lens doses for occupational staff in different kinds of interventional procedures were measured by the devices with both single-and double X-ray tubes.The data obtained fromthe direct-reading dosimeters was compared to those obtained from TLDs.Results Direct-reading dosimeters showed good linear fitting with the calibration of HP (3),and the coefficients of variation were lower than 5%.The average eye lens HP (3) for the main operator in coronary arteriography and stent implantation in brain obtained by direct-reading dosimeters were 12.0 and 24.5 μSv,respectively,whereas those obtained by TLDs were 11.9 and 22.7 μSv,respectively.The direct-reading dosimeters gave similar t~nds as TLDs do so.The direct-reading dosimeters were able to provide eye lens HP (3) in each individual interventional procedure,and to monitor the real-time dose rate as well.Conclusions The calibration of HP (3) and the data gained by direct-reading dosimeters are reliable.Therefore,the methods for real-time measurement of eye lens dose for occupational staff in interventional procedures are successfully established.

SELECTION OF CITATIONS
SEARCH DETAIL