Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
J. oral res. (Impresa) ; 11(4): 1-13, jul. 21, 2022. ilus, tab
Article in English | LILACS | ID: biblio-1427085

ABSTRACT

Objetive: To compare the stresses and deformations generated on the surrounding bone of the zygomatic implants when using an intra sinusal and extra-maxillary approach, through the finite element method. Material and Methods: Computer aided designs (CADs) were constructed using SolidWorks Software of a skull with bone resorption to be rehabilitated through a fixed hybrid prosthesis using two zygomatic and two conventional straight implants. For the boundary conditions (load conditions), symmetry in the sagittal plane was assumed and that all the materials were isotropic, homogeneous and linearly elastic. Two zygomatic implantation techniques were simulated: intra sinusal (Is) and extra maxillary (Em). Vertical and lateral loads of 150 N and 50 N were applied to the finite element models to obtain Von Mises equivalent stress and strain (displacement). Results: The average measurement of the Von Mises stress (MPa) recorded were as follows: Approach of the implant body (Is: 0.24- Em: 0.28,) effort of implant body with vertical load: Is: 0.69 - Em: 0.96; effort of peri-implant surface under horizontal load: Is: 2.11 - Em: 0.94. Average displacement under vertical load of peri-implant surface Is: 0.35 - Em: 0.40, and of implant body Is: 1.34 - Em: 2.04. Average total deformation in approach Is: 2.23 mm - Em: 0.80mm, and average total deformation in the implant body under horizontal load was Is: 0.14 - Em: 0.21. Conclusion: The results of this study indicate that despite the differences that occurred in both stress and strain (displacement) between the intra-sinus and extra-maxillary approaches, the static strength of the bone, which is approximately 150 MPa in tension and 250 MPa in compression was not exceeded. Considering the limitations of finite element analysis, there seems to be no biomechanical reason to choose one approach over the other.


Objetivo: Comparar por el método de elementos finitos los esfuerzos y deformaciones generados sobre el hueso circundante de implantes cigomáticos tratados con un abordaje intra sinusal y extra maxilar. Material y Métodos: Se construyeron los diseños asistidos por computadora (CAD) utilizando el Software SolidWorks de un cráneo con una reabsorción ósea para ser rehabilitado, a través de una prótesis híbrida fija, mediante dos implantes cigomáticos y dos rectos convencionales. Para las condiciones de frontera (condiciones de carga) se asumió simetría en el plano sagital y que todos los materiales eran isotrópicos, homogéneos y linealmente elásticos. Se simularon dos técnicas de implantación cigomática: una intra sinusal (Is) y otra extra maxilar (Em). Se aplicaron cargas verticales y laterales de 150 N y 50 N a los modelos de elementos finitos para obtener el esfuerzo equivalente de Von mises y la deformación (desplazamiento). Resultados: La medición promedio del esfuerzo de Von Mises (MPa) registró: abordaje del cuerpo de implante (Is: 0.24-Em: 0.28) esfuerzo del cuerpo de implante con carga vertical: (Is:0.69 ­ Em: 0.96); esfuerzo de la superficie peri implantar ante carga horizontal (lateral):( Is:2.11 ­ Em:0.94). Desplazamiento promedio ante carga vertical de la superficie peri implantar (Is:0.35 ­ Em:0.40) y del cuerpo del implante (Is:1.34 ­ Em:2.04). Deformación total promedio en mm en abordaje (Is: 2.23 ­ Em:0.80) y deformación total promedio en el cuerpo del implante ante carga horizontal (Is:0.14 ­ Em:0.21). Conclusión: Los resultados de este estudio indican que a pesar de las diferencias que se presentaron tanto en el esfuerzo como en la deformación (desplazamiento) entre los abordajes intra sinusal y extra maxilar, la resistencia estática del hueso, que es de aproximadamente 150 MPa en tensión y 250 MPa en compresión no se superó. Considerando las limitaciones de los AEF, parece no haber razones biomecánicas para elegir uno u otro enfoque.


Subject(s)
Humans , Dental Implants , Finite Element Analysis , Maxillary Sinus/physiology , Zygoma/surgery , Jaw, Edentulous, Partially/rehabilitation , Weight-Bearing , Computer-Aided Design
2.
Odontol. vital ; (36)jun. 2022.
Article in Spanish | LILACS, SaludCR | ID: biblio-1386464

ABSTRACT

Resumen Introducción: El presente informe de caso clínico se enfoca en el diagnóstico y tratamiento para la rehabilitación de la dentición temporal en el sector anterosuperior utilizando tecnología CAD-CAM. Objetivo: Proponer una alternativa para mitigar el margen de error y tiempo de trabajo en el paciente pediátrico, reintegrando la estética y funcionalidad en la cavidad oral. Métodos: Se describe el caso de un paciente de sexo masculino de 6 años que acudió a la clínica universitaria de la Universidad UTE con lesiones cariosas extensas en sus dientes anterosuperiores y su rehabilitación a través de la utilización de coronas personalizadas de resina mediante un encerado digital realizado en CAD-CAM. Resultados: El tratamiento efectuado en el niño fue satisfactorio, se evidenció una mejoría en la dimensión vertical e incremento en la estética dental y facial, mejorando su aspecto y autoestima después de la rehabilitación. Conclusión: La utilización del encerado digital en pacientes pediátricos podría ser una alternativa que permita reducir el tiempo de trabajo del tratamiento en una rehabilitación estética dental.


Abstract Introduction: This case report focuses on the diagnosis and treatment for the rehabilitation of the primary dentition in the anterosuperior sector using CADCAM technology. Objective: To propose an alternative to mitigate the margin of error and working time in pediatric patients, reintegrating esthetics, and functionality in the oral cavity. Methods: We describe the case of a 6-year-old male patient who came to the clinic of Universidad UTE with extensive carious lesions in his anterosuperior teeth and his rehabilitation using personalized resin crowns by means of a digital waxup performed in CAD-CAM. Results: The treatment performed on the child was satisfactory, there was an improvement in the vertical dimension and an increase in dental and facial esthetics, improving his appearance and self-esteem after the rehabilitation. Conclusión: The use of digital wax-up in pediatric patients could be an alternative that allows the treatment time to be reduced in esthetic dental rehabilitation.


Subject(s)
Humans , Male , Child , Dental Veneers , Resins
3.
Rev. cuba. invest. bioméd ; 40(3)sept. 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1408569

ABSTRACT

Introducción: La calidad del aprendizaje en odontología depende en gran medida del tipo y tiempo de práctica que se dedique con estos fines. El diseño y fabricación asistidos por computadora (CAD/CAM) que al ofrecer significativas mejoras en diversos aspectos dentro del modelado dental, advierten con reemplazar al método tradicional del modelado en yeso. Objetivo: Resumir información referente al uso de la tecnología CAD/CAM dentro del proceso enseñanza-aprendizaje de la educación dental. Métodos: Se consultaron las bases de datos MEDLINE y SciELO a través de los términos diseño asistido por computadora, CAD/CAM, enseñanza, educación dental y educación en odontología. Fueron seleccionados 36 documentos publicados a partir del año 2015. Se analizaron las categorías: definición y usos, viabilidad en la educación dental, perspectiva estudiantil, ventajas y desventajas. Análisis e integración de la información: El diseño y manufactura asistidos por computadora es un sistema tecnológico de prototipado rápido que es capaz de materializar modelos digitales diseñados en una interfaz externa, a partir de la información del escaneo realizado. Su incorporación a la educación dental se ha dado de forma dispareja y no sincronizada, debido al gasto económico requerido tanto para la compra del equipo y adaptación de las instalaciones como para la capacitación del personal pertinente. Conclusión: La aplicación del diseño y manufactura asistidos por computadora permite la creación de modelos dentales con grandes beneficios para el entrenamiento práctico. Asimismo, favorece el acercamiento hacia la estandarización de la enseñanza y la objetividad al momento de calificar el trabajo de los estudiantes realizado sobre estos modelos. La barrera económica sigue siendo una fuerte limitante para la implementación del diseño y manufactura asistidos por computadora en la educación dental, pese a ello, los estudiantes suelen presentar aceptación y una gran predisposición para su uso y aplicación(AU)


Introduction: The quality of learning in dentistry depends to a great extent on the type and time of practice devoted to these purposes. Computer-aided design and manufacturing (CAD/CAM) that, by offering significant improvements in various aspects within dental modeling, warns of replacing the traditional method of modeling in plaster. Objective: Summarize information regarding the use of CAD/CAM technology within the teaching-learning process of dental education. Methods: A search was conducted in the databases MEDLINE and SciELO using the descriptors omputer-aided design, CAD/CAM, teaching and dental education. A total 36 documents were selected, published as of the year 2015. The variables considered were definition and uses, viability in dental education, student perspective, advantages and disadvantages. Data analysis and integration: Computer-aided design and manufacturing is a rapid prototyping technological system capable of materializing digital models designed in an external interface based on scanned information. Its incorporation into dental education has been uneven and unsynchronized, due to the expenses required by the purchase of equipment, adaptation of existing facilities and training of the relevant personnel. Conclusion: Computer-aided design and manufacturing makes it possible to create dental models which are very beneficial to practical training. It is also a step forward on the road to standardization of teaching and objectivity when grading the work done by students on these models. Economic limitations continue to strongly handicap the implementation of computer-aided design and manufacturing in dental education. Despite this, students recognize its usefulness and have shown their willingness to apply it(AU)


Subject(s)
Teaching/education , Computer-Aided Design , Learning , Models, Dental/trends , Education, Dental
4.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in Spanish | LILACS, SaludCR | ID: biblio-1386529

ABSTRACT

RESUMEN: Se realizó un estudio descriptivo y exploratorio con el objetivo de proponer y validar un protocolo abierto para hacer impresiones 3D de modelos estereolitográficos, que esté a disposición de profesionales en el área de la Odontología. Se capacitó mediante sesiones teórico prácticas, a nueve personas operadoras (estudiantes de último año de la carrera de Odontología), sin previa experiencia en el uso de software y hardware para impresión 3D, divididos en dos grupos; el A trabajó con tres tomografías helicoidales (TAC) y el B con tres Tomografías Computarizadas de Haz Cónico (CBCT), todas en formato DICOM, convertidas en archivos STL. En total se aplicó el protocolo en 99 estructuras óseas correspondientes a 33 mandíbulas, 33 axis y 33 macizos faciales-bases de cráneo, y se imprimieron un total de 33 mandíbulas en filamento PLA (ácido poliláctico). Al finalizar el estudio, no se encontró diferencia estadísticamente significativa en la implementación del protocolo propuesto entre los operadores, las mediciones de las piezas impresas por cada uno de ellos, el patrón de oro, la TAC y el CBCT, con lo cual no solo se validó el protocolo, sino que se logró determinar los recursos necesarios para realizar este tipo de impresiones 3D.


ABSTRACT: A descriptive and exploratory study was carried out with the aim of proposing and validating an open protocol for making 3D impressions of stereolithographic models, which is available to professionals in the area of Dentistry. Nine operators (senior students of the Dentistry degree), without previous experience in the use of software and hardware for 3D printing, divided into two groups were trained through theoretical and practical sessions. The A worked with three helical tomographies (TAC) and the B with three cone beam computed tomography (CBCT), all in DICOM format, converted to STL files. In total, 99 bone structures corresponding to 33 jaws, 33 axis and 33 facial masses-skull bases were analyzed, and a total of 33 jaws were printed in PLA (polylactic acid filament). At the end of the study, no statistically significant difference was found in the implementation of the proposed protocol between the operators, the measurements of the pieces printed by each of them, the gold standard, the TAC and the CBCT, with which not only validated the protocol, but it was possible to determine the resources necessary to carry out this type of 3D printing.


Subject(s)
Printing, Three-Dimensional/instrumentation , Stereolithography/instrumentation , Biomedical and Dental Materials , Tomography/methods , Dentistry
5.
J. oral res. (Impresa) ; 10(4): 1-6, ago. 31, 2021. ilus
Article in English | LILACS | ID: biblio-1395937

ABSTRACT

Introduction: Ectodermal dysplasia (ED) comprises a broad group of genetic disorders characterized by alterations of the structures derived from the ectoderm, including those of the stomatognathic system. Case Report: The present article aims to report the prosthetic management of a patient with anhidrotic ectodermal dysplasia. A male patient diagnosed with ED who attended the dental consultation displaying oligodontia; underdeveloped alveolar ridges were observed. Results: The established treatment consisted of the adaptation of implant-supported fixed full-arch prosthesis designed through CAD-CAM technology for the lower jaw and of a removable partial prosthesis with muco-dental support for the upper jaw. The dental approach of patients with ED is based on a correct analysis of the facial characteristics and stomatological conditions of each subject. Conclusion: A multidisciplinary approach is mandatory due to the biological and functional complexity in biomechanical terms of these individuals.


Introducción: La displasia ectodérmica (DE) comprende un amplio grupo de trastornos genéticos caracterizados por alteraciones de las estructuras derivadas del ectodermo, incluidas las del sistema estomatognático. Reporte de Caso: El presente artículo tiene como objetivo informar del manejo protésico de un paciente con displasia ectodérmica anhidrótica. Paciente varón diagnosticado de DE acudió a consulta odontológica por oligodoncia; Se observaron crestas alveolares subdesarrolladas. Resultados: El tratamiento establecido consistió en la adaptación de una prótesis de arcada completa fija implantosoportada diseñada mediante tecnología CAD-CAM para el maxilar inferior y de una prótesis parcial removible con soporte muco-dental para el maxilar superior. El abordaje odontológico de los pacientes con DE se basa en un correcto análisis de las características faciales y condiciones estomatológicas de cada sujeto. Conclusión: Un enfoque multidisciplinario es obligatorio debido a la complejidad biológica y funcional en términos biomecánicos de estos individuos.


Subject(s)
Humans , Male , Adult , Young Adult , Ectodermal Dysplasia/rehabilitation , Dental Prosthesis, Implant-Supported , Anodontia/rehabilitation , Dental Implants , Treatment Outcome , Dental Prosthesis Design , Dental Implants, Single-Tooth , Ectodermal Dysplasia 1, Anhidrotic
6.
Odontol. sanmarquina (Impr.) ; 24(2): 5-11, abr.-jun. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1178061

ABSTRACT

Objetivo. El objetivo de este estudio fue evaluar la adaptación marginal de coronas de disilicato de litio obtenidas mediante técnicas de escaneo (CAD/CAM), antes y des- pués de la cristalización, a través de análisis in vitro con microscopía confocal (MC). Métodos. Fueron confeccionadas 16 réplicas en poliuretano a partir de la pieza 1.4, de modelo typodont, tallada para corona total. Las réplicas fueron divididas en dos gru- pos, de acuerdo a la técnica de escaneo: Técnica Indirecta (Grupo IND, n=08), donde modelos de yeso fueron escaneados con escáner de laboratorio (inEos X5, Sirona Den- tal Systems) y Técnica Directa (Grupo DIR, n=08), donde modelos typodont fueron escaneados con escáner intraoral (CEREC BlueCam, Sirona Dental Systems). A seguir, se fresaron (inLab MC XL, Sirona Dental Systems) coronas en disilicato de litio (IPS e.max CAD, Ivoclar Vivadent) y se adaptaron a las réplicas. Se evaluó la adaptación marginal con análisis de MC en dos momentos, antes y después de la cristalización del disilicato de litio. Los datos fueron analizados con la prueba de Mann-Whitney, t de Student y Wilcoxon (α= 0,05). Resultados. Hubo una diferencia estadísticamente significativa en la adaptación marginal horizontal entre los grupos IND y DIR después de la cristalización (p=0,05). En el grupo IND, la comparación de la adaptación mar- ginal vertical antes y después de la cristalización mostró una diferencia estadísticamente significativa (p=0,038). Conclusiones. Las coronas de disilicato de litio obtenidas me- diante escaneo directo (CAD/CAM) presentaron menor desajuste marginal vertical. La etapa de cristalización afectó la adaptación marginal de las coronas.


Objective. This study aimed to evaluate lithium disilicate marginal adaption on crowns by scanning techniques (CAD/CAM), before and after crystallization, through confocal microscopy (CM) in vitro analysis. Methods. Sixteen polyurethane replicas were per- formed from tooth 1.4, of a typodont model, prepared for a full crown. The replicas were divided into two groups, according to the scanning technique: Indirect Technique (Group IND, n=08), where dental stone models were scanned with a laboratory scanner (inEos X5, Sirona Dental Systems) and Direct Technique (Group DIR, n=08), where typodont models were scanned with an intraoral scanner (CEREC BlueCam, Sirona Dental Systems). Then, the lithium disilicate crowns (IPS e.max CAD, Ivoclar Vivadent) were milled (inLab MC XL, Sirona Dental Systems) and adapted to the replicas. Margin- al adaptation was evaluated with CM analysis before and after lithium disilicate crystalli- zation. Data were analyzed with the Mann-Whitney, t test, and Wilconxon test (α=0.05). Results. There was a statistically significant difference in horizontal marginal adaptation between IND and DIR groups after crystallization (p=0.05). In IND group, the compar- ison of vertical marginal adaptation before and after crystallization showed a statistically significant difference (p=0.038). Conclusions. Lithium disilicate crowns obtained by direct scanning technique (CAD/CAD) showed less vertical marginal maladjustment. The crystallization stage affected the crown's marginal adaptation.

7.
Rev. mex. ing. bioméd ; 41(2): 53-65, may.-ago. 2020. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1139337

ABSTRACT

Resumen En el presente trabajo se plantea un análisis biomecánico de una prótesis de cadera bajo condiciones de cargas estáticas asociadas a actividades cotidianas, en el cual se comparan tres materiales metálicos para la fabricación de una prótesis personalizada a partir de imágenes médicas. Se utilizaron plataformas en la nube de diseño asistido por computadora y de análisis por elementos finitos. Se diseñaron dos modelos de la prótesis a analizar, uno hueco y otro sólido mediante curvas spline paramétricas. Para el análisis biomecánico se requirió un tamaño de malla de 2,537,684 de elementos tetraédricos y 471,335 nodos para estudiar siete casos de posturas para una persona de 75 kg de peso, mismos que se analizaron tomando como materiales base acero inoxidable 316L, aleación Ti-6AL-4V y L-605. Se observó que con actividades tales como trotar, subir y bajar escaleras los materiales 316L y L-605, presentan el riesgo de deformación plástica e inclusive fractura. Los resultados mostraron que el material más idóneo para la fabricación de este tipo de prótesis es el Ti-6Al-4V, además de que este nos permite realizar modelos tanto sólidos como huecos, suponiendo este último, un ahorro de material y proporcionando mayor ligereza en la prótesis.


Abstract This paper shows a biomechanical analysis of a hip prosthesis under conditions of static loads associated with daily activities. For which it compared three metallic materials for the manufacture of a customized prosthesis from medical images, it was used cloud platforms with computer-aided design and finite element analysis. Two models of prosthesis one hollow and the other one solid using parametric spline curves were designed and analyzed. The biomechanical analysis required a mesh size consisting of 2,537,684 tetrahedral elements and 471,335 nodes to study seven cases of postures for a person weighing 75 kg. These cases were analyzed based on 316L stainless steel, Ti-6AL-4V alloy, and another L-605 alloy. It was observed that with activities such as jogging, climbing and descending stairs, materials 316L, and L-605 present the risk of plastic deformation and even fracture. The results show that the most suitable material for the manufacture of this type of prosthesis is the Ti-6Al-4V, which allows us to make both solid and hollow models. Assuming this last material is saved and improves the prosthesis lightness.

8.
Odontol. vital ; (32)jun. 2020.
Article in Spanish | LILACS, SaludCR | ID: biblio-1386421

ABSTRACT

Resumen Evaluar la influencia del tipo de terminación marginal; filo de cuchillo (F) y chamfer (C) sobre la resistencia flexural de coronas de disilicato de litio CAD/CAM en espesores de 0,8 mm y 0,5 mm. Materiales y métodos: 40 premolares superiores sanos, en 2 grupos de acuerdo con el tipo de terminación G1=F y G2=C; 2 subgrupos referentes al espesor del material Sg1=0,8mm y Sg2 0,5 mm (5 coronas por cada subgrupo), se sometieron a fuerzas de compresión vertical (v) y horizontal (h). Se observó el tipo de fractura más frecuente; cohesivas en porcelana (cp), adhesiva en porcelana (ap), mixta pequeña (mp) y mixta larga (ml). Resultados: En preparaciones a 0,8 mm y 0,5 mm, existió diferencia significativa en relación con la mejor terminación, esta fue el C; sus valores fueron, Sg1 (h=1347,2 N / v=1402,0. F; Sg1 (h=965,6 N/ v= 794,8 N). F a 0,5 mm mostró mejor desempeño ante fuerzas horizontales. C; Sg2 (h=924,8 N /v=813,4 N) y para F; Sg2 (h=1217,0 N /v= 576,0 N). Conclusiones: Tipo de fractura más frecuente es cp y ap. Terminación chamfer y filo de cuchillo pueden ser utilizados con seguridad, pues muestran valores aceptables de resistencia flexural, al reducirse el grosor de la restauración en chamfer reduce su resistencia, el filo de cuchillo la aumenta.


Abstract Objective: To evaluate the influence of the type of shoulder margins; Knife edge (F) and Chamfer (C) on the flexural strength of CAD / CAM lithium disilicate crowns in thicknesses of 0.8 mm and 0.5 mm. Materials and Methods: 40 healthy upper premolars, in 2 groups according to the type of termination G1 = F and G2 = C; 2 subgroups referring to the material thickness Sg1 = 0.8mm and Sg2 0.5mm (5 crowns for each subgroup), were subjected to vertical (v) and horizontal (h) compression forces. The most frequent type of fracture was observed; cohesive in porcelain (cp), adhesive in porcelain (ap), mixed small (mp) and mixed long (ml). Results: In preparations with 0.8 mm and 0.5 mm thicknesses, there was a significant difference in relation to the best termination, this was C; their values were Sg1 (h = 1347.2 N / v = 1402.0.F; Sg1 (h = 965.6 N / v = 794.8 N) .F at 0.5 mm showed better performance against horizontal forces C; Sg2 (h = 924.8 N / v = 813.4 N) and for F; Sg2 (h = 1217.0 N / v = 576.0 N) Conclusions: The most frequent type of fracture is cp and ap finishing chamfer and knife edge can be used safely show acceptable values of flexural strength, by reducing the thickness of the chamfer restoration reduces its strength, the knife edge increases it.


Subject(s)
Crowns , Dental Materials/analysis
9.
Rev. estomatol. Hered ; 29(3): 231-240, jul.-sep 2019. ilus, tab
Article in Spanish | LILACS-Express | LILACS, BBO | ID: biblio-1144579

ABSTRACT

En la actualidad existe un amplio uso de los postes de fibra de vidrio. Sin embargo, tienen la desventaja que su forma no se pueden cambiar y son inadecuadas para casos de dientes con amplia destrucción coronal y conductos radiculares amplios. Este reporte de caso clínico describe el uso de un poste y núcleo de fibra de vidrio fabricados con un sistema CAD/CAM para restaurar un diente premolar inferior tratado endodónticamente. Este poste de fibra de vidrio CAD/CAM se adapta mejor al conducto radicular que un poste prefabricado, sin necesidad de emplear resina compuesta para el muñón y reduce el espesor de la capa de cemento.


Currently, there is a wide use of fiberglass post. However, they have the disadvantage that their shape can not be changed and are inadequate for cases of teeth with extensive coronal destruction and wide root canals. This case report describes the use of a fiberglass post and core manufactured with a CAD / CAM system to restore a lower premolar tooth treated endodontically. This CAD / CAM fiberglass post adapts better to the root canal than a prefabricated post, without the need to use composite resin for the stump and reduces the thickness of the cement layer.

SELECTION OF CITATIONS
SEARCH DETAIL