Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Coluna/Columna ; 16(2): 141-144, Apr.-June 2017. tab, graf
Article in English | LILACS | ID: biblio-890888

ABSTRACT

ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each procedure and in real time. Results: The radiation dose absorbed by the surgeon was higher when using the standard C-arm fluoroscopic technique than when using the C-arm with L-arm or the biplanar technique. Conclusions: The use of the C-arm with L-arm, or the biplanar fluoroscopic technique, for percutaneous access to the vertebral pedicle, reduces the radiation exposure of the surgeon compared to the standard C-arm fluoroscopic technique.


RESUMO Objetivo: Comparar a exposição à radiação do cirurgião, paciente e técnico de radiologia durante acesso percutâneo do pedículo vertebral, usando três diferentes técnicas fluoroscópicas. Métodos: Acesso percutâneo do pedículo vertebral de T9-L5 de nove cadáveres de adultos do sexo masculino usando três diferentes técnicas de fluoroscopia: arco cirúrgico padrão, arco cirúrgico com braço em "L" e técnica biplanar. A radiação recebida por cirurgião, cadáver e técnico de radiologia foi mensurada com dosímetro em cada procedimento e em tempo real. Resultados: A dose de radiação absorvida pelo cirurgião foi maior com o uso do arco cirúrgico padrão, em comparação com o uso de arco cirúrgico com braço em "L" ou com técnica biplanar. Conclusões: O uso do arco cirúrgico com braço em "L" ou da técnica biplanar para acesso percutâneo do pedículo vertebral reduz a exposição do cirurgião à radiação em comparação com a técnica fluoroscópica com arco cirúrgico padrão.


RESUMEN Objetivo: Comparar la exposición a la radiación del cirujano, paciente y técnico de radiología durante el acceso percutáneo del pedículo vertebral, utilizando tres técnicas fluoroscópicas diferentes. Métodos: Acceso percutáneo del pedículo vertebral de T9-L5 de nueve cadáveres de adultos del sexo masculino utilizando tres técnicas fluoroscópicas diferentes: arco en C estándar, arco en C con brazo en L y técnica biplanar. La radiación recibida por cirujano, cadáver y técnico de radiología se midió usando dosímetro en cada procedimiento y en tiempo real. Resultados: La dosis de radiación absorbida por el cirujano fue mayor cuando se usó la técnica del arco en C estándar, en comparación con el arco en C con brazo en L o con técnica biplanar. Conclusiones: El uso del arco en C con brazo en L o de la técnica biplanar para el acceso percutáneo del pedículo vertebral reduce la exposición a la radiación del cirujano en comparación con la técnica fluoroscópica con arco en C estándar.


Subject(s)
Radiation Exposure/adverse effects , Radiation Dosage , Fluoroscopy , Minimally Invasive Surgical Procedures
2.
Radiol. bras ; 49(3): 176-181, graf
Article in English | LILACS | ID: lil-787595

ABSTRACT

Abstract The present review aims to offer an educational approach related to the limitations in the use of the effective dose mgnitude as a tool for the quantification of doses resulting from diagnostic applications of ionizing radiation. We present a critical analysis of the quantities accepted and currently used for dosimetric evaluation in diagnostic imaging procedures, based on studies published in the literature. It is highlighted the use of these quantities to evaluate the risk attributed to the procedure and to calculate the effective dose, as well as to determine its correct use and interpretation.


Resumo Este trabalho de revisão pretende oferecer uma abordagem educacional relacionada às limitações na utilização da grandeza dose efetiva como ferramenta para quantificação de doses decorrentes de aplicações em diagnóstico médico utilizando radiações ionizantes. Os autores apresentam uma análise crítica sobre as grandezas aceitas e utilizadas atualmente para a avaliação dosimétrica em procedimentos de diagnóstico médico por imagem, tendo como base estudos publicados na literatura. Destacam-se as formas de utilização dessas grandezas para a avaliação do risco atribuído ao procedimento e para o cálculo da dose efetiva e sua correta utilização e interpretação.

3.
Rev. bras. cardiol. invasiva ; 22(4): 333-338, Oct-Dec/2015. tab
Article in Portuguese | LILACS, SES-SP | ID: lil-744567

ABSTRACT

Introdução: Os mecanismos e preditores de insucesso da técnica radial em centros que priorizam essa via não estão bem caracterizados, sendo tal caracterização o objetivo principal desta análise. Métodos: Foram incluídos 6.808 pacientes consecutivos submetidos a procedimentos coronários invasivos pelo acesso radial por operadores com taxa anual de utilização da via superior a 90%. Para a identificação dos fatores associados ao insucesso da técnica, foram ajustados modelos de regressão logística simples e múltipla. Resultados: A taxa de insucesso da técnica radial foi de 1,7%. Complicações vasculares ocorreram em 5% da amostra, com predomínio de oclusão arterial assintomática e hematomas subcutâneos. Os preditores de insucesso foram sexo feminino (OR = 1,87; IC 95% 1,29-2,71; p = 0,01), idade > 70 anos (OR = 1,78; IC 95% 1,06-2,98; p = 0,03) e presença de insuficiência arterial periférica crônica (OR = 5,71; IC 95% 2,40-13,54; p < 0,01). Conclusões: Em um centro caracterizado por alto volume de procedimentos realizados pelo acesso radial, a taxa de insucesso foi < 2%, sendo as variáveis associadas à falência da técnica sexo feminino, idade avançada e insuficiência arterial periférica..


Background: The mechanisms and predictors of failure of the transradial approach in centers dedicated to this technique are not well characterized and were the main objective of this analysis. Methods: 6,808 consecutive patients undergoing transradial coronary procedures by operators with utilization rate greater than 90% were included. Simple and multiple logistic regression models were used to identify the predictors of failed transradial approach. Results Transradial failure rate was 1.7%. Vascular complications were observed in 5% of the sample, with a prevalence of asymptomatic arterial occlusion and subcutaneous hematomas. Predictors of failure were female gender (OR = 1.87; 95% CI: 1.29-2.71; p = 0.01), age > 70 years (OR = 1.78; 95% CI: 1.06-2.98; p = 0.03) and presence of chronic peripheral arterial disease (OR = 5.71; 95% CI: 2.40-13.54; p < 0.01). Conclusions In a high-volume radial center, the failure rate was < 2% and variables associated with failure of the technique were female gender, advanced age and peripheral arterial disease...


Subject(s)
Humans , Male , Female , Aged , Radial Artery/physiology , Surgicenters , Peripheral Vascular Diseases , Acute Coronary Syndrome , Predictive Value of Tests , Multivariate Analysis , Risk Factors , Hemorrhage , Percutaneous Coronary Intervention/methods
4.
Rev. bras. cardiol. invasiva ; 22(4): 320-323, Oct-Dec/2015. tab, graf
Article in Portuguese | LILACS | ID: lil-744579

ABSTRACT

Introdução: Procedimentos cardiológicos invasivos expõem Médicos e enfermeiros/técnicos de enfermagem aos riscos da radiação ionizante. O objetivo deste estudo foi determinar os padrões de exposição radiológica em profissionais da saúde durante procedimentos cardiológicos. Métodos: Estudo prospectivo incluindo pacientes submetidos a procedimento cardiológico invasivo entre dezembro de 2011 e agosto de 2012 em equipamento com detectores do tipo plano. Características clínicas, angiográficas e de exposição à radiação foram registradas em banco de dados específico. Os padrões de exposição à radiação foram determinados em pacientes submetidos ao cateterismo cardíaco diagnóstico. Correlação entre dose do médico operador e enfermeiro/técnico de enfermagem também foi efetuada. Resultados: Amostra incluiu 119 pacientes submetidos ao cateterismo. A dose de kerma no ar e o produto dose-área médio de radiação recebida pelos pacientes foram de 549 ± 220 mGy e 29.054 ± 14.696 mGy.cm2, respectivamente. Médicos e enfermeiros/técnicos de enfermagem foram expostos à dose efetiva média por exame de 0,47 ± 0,16 e 0,28 ± 0,13 mSv, respectivamente. A correlação entre dose efetiva dos Médicos e enfermeiro/técnicos de enfermagem foi de 0,54 ( p < 0,001). Conclusões: Médicos e enfermeiros/técnicos de enfermagem são expostos a doses pequenas de radiação ionizante durante cateterismo cardíaco diagnóstico. Enfermeiros/técnicos de enfermagem são expostos a cerca de 60% da dose do médico operador...


Background: Invasive cardiologic procedures expose physicians and nurses/technicians to the risks of ionizing radiation. The aim of this study was to determine the exposure patterns in healthcare professionals during cardiologic procedures. Methods: Prospective study including patients undergoing invasive cardiologic procedures between December 2011 and August 2012 using flat-panel detector fluoroscopy. Clinical, angiographic and radiation exposure characteristics were recorded in a dedicated database. Patterns of radiation exposure were determined in patients undergoing diagnostic cardiac catheterization. The correlation between surgeon and nurse/technician dose was also evaluated. Results: The sample included 119 patients undergoing catheterization. The patient mean air kerma dose and dose-area product was 549 ± 220 mGy and 29,054 ± 14,696 mGy.cm2, respectively. Physicians and nurses/technicians were exposed to a mean effective dose of 0.47 ± 0.16 and 0.28 ± 0.13 mSv per exam, respectively. The correlation between physicians and nurses/technicians effective dose was 0.54 (p < 0.001). Conclusions: Physicians and nurses/technicians are exposed to low ionizing radiation doses during diagnostic cardiac catheterization. Nurses/technicians are exposed to approximately 60% of the operating physician's dose...


Subject(s)
Humans , Male , Female , Middle Aged , Cardiac Catheterization , Health Personnel , Radiation Exposure , Radiation, Ionizing , Radiation Dosage , Occupational Exposure/prevention & control , Observational Study , Prospective Studies , Minimally Invasive Surgical Procedures/methods
5.
Rev. odontol. UNESP (Online) ; 43(4): 252-257, July-Aug/2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-714861

ABSTRACT

Introdução: Para que radiografias ofereçam mais benefícios do que riscos, precisam ser realizadas ou solicitadas de acordo com cada situação clínica. Objetivo: Avaliar os exames radiográficos solicitados no atendimento inicial em uma Faculdade de Odontologia, considerando os sinais/sintomas e o motivo para busca pelo atendimento. Material e Método: Foram avaliados os prontuários de 3.100 pacientes adultos, tratados em um período de três anos, excluindo aqueles em que os pacientes não haviam realizado exames radiográficos na consulta inicial. Numa amostra final de 1.567 prontuários, foram coletados os seguintes dados: idade e gênero, razão da procura pelo tratamento, presença de sinais e/ou sintomas, além da técnica e do número de radiografias realizadas. Os dados foram analisados por estatística descritiva. Resultado: 5.034 radiografias realizadas, com média de 3,24 (±2,97) por paciente. Entre as técnicas, a mais utilizada foi a periapical seguida pela panorâmica. Extração dentária e dor foram as razões mais prevalentes da procura pelo atendimento, enquanto dor, doença periodontal e presença de patologias de tecidos moles foram os sinais/sintomas mais comuns. Verificou-se que 35,41% da amostra não apresentou sinais ou sintomas. Conclusão: Há uma grande variação na requisição de radiografias no exame inicial, mostrando uma falha na aplicação de critérios de seleção de imagens para diagnóstico, o que pode levar à exposição desnecessária do paciente à radiação X. .


Introduction: For X-rays offer more benefits than risks, they need to be performed or ordered according to each clinical situation. Objective: To evaluate the radiographic exams requested in the initial care in a dental school, considering signs/symptoms and the reported reasons for seeking care. Material and Method: We evaluated the medical records of 3100 adult patients treated over a period of three years, and eliminated those who had not performed radiographic examinations in the initial care. In a final sample of 1567 records, was collected: age and gender, reason for seeking care, presence of signs and/or symptoms, beyond technique and the number of radiographs requested. The dates were analysed by descriptive statistics. Result: 5034 radiographs were made, mean of 3.24 (±2.97) per patient. Among the techniques, the most widely used was the periapical, followed by panoramic. Tooth extraction and pain were the most prevalent reasons for seeking care, while pain, periodontal disease and the presence of soft tissue pathologies were the signs/symptoms more common. 35.41% of the sample had no signs or symptoms. Conclusion: There is a wide variation in the request of radiographs for initial care showing a lack of application of criteria in the selection diagnostic imaging, which can lead to unnecessary exposure to radiation X. .


Subject(s)
Radiation Dosage , Radiography, Dental , Radiography, Panoramic , Dental Records , Dental Care , Practice Guideline , Pain , Tooth Extraction , Diagnosis, Oral , Medical History Taking
6.
Rev. bras. ortop ; 46(2): 136-138, maio-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-592202

ABSTRACT

OBJETIVO: Averiguar o tempo médio de emissão de radiação por aparelho de fluoroscopia durante variadas cirurgias ortopédicas e quais necessitam maior uso de radiação. MÉTODOS: Foram contabilizados os tempos em 16 cirurgias diferentes, totalizando 80 procedimentos. Ao final de cada procedimento foi verificado o tempo de utilização de fluoroscopia diretamente do intensificador de imagem. RESULTADOS: Foram necessários em média 61 segundos de fluoroscopia por operação. Os procedimentos que demandaram mais uso de radiação em média foram epifisiodese femoral proximal bilateral (5,1 minutos) e osteossíntese diafisária de fêmur com haste intramedular bloqueada (3,33 minutos). CONCLUSÃO: O tempo médio de fluoroscopia em cirurgias ortopédicas foi de 61 segundos. Os procedimentos com uso de dispositivo intramedular são os que requerem maior emissão de radiação.


OBJECTIVE: To ascertain the mean length of radiation emission from fluoroscopic devices during several types of orthopedic surgery and which of these required greater use of radiation. METHODS: The times taken to perform sixteen different types of surgery (total of 80 procedures) were measured. At the end of each procedure, the length of time for which fluoroscopy was used directly from the image intensifier was ascertained. RESULTS: The mean time required for fluoroscopy per operation was 61 seconds. The procedures that demanded greatest mean duration of radiation use were bilateral proximal femoral epiphysiodesis (5.1 minutes) and femoral shaft osteosynthesis using a locked intramedullary nail (3.33 min). CONCLUSION: The mean duration of fluoroscopy use in orthopedic operations was 61 seconds. The procedures using an intramedullary device were the ones that required greatest radiation emission.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Fluoroscopy , Orthopedics , Radiation Dosage
7.
J. Health Sci. Inst ; 25(4)out.-dez. 2007. ilus
Article in Portuguese | LILACS | ID: lil-655197

ABSTRACT

O objetivo deste trabalho é comparar as doses de radiação proporcionadas pelos diversos tipos de tomografia, por meio de revisão da literatura disponível de 1992 a 2006. Embora haja divergências entre os autores, a tomografia computadorizada produz as doses mais elevadas de radiação. Valores inferiores foram encontrados para tomografia convencional e computadorizada de feixe cônico.


The aim of this study is to revise the available literature from 1992 to 2006 related to radiation doses provided by several kind of tomography, in order to compare the different and available systems. Although there are divergences among authors the computed tomography produces the most elevated doses of radiation. Inferior values were found for conventional and computerized cone beam tomography.


Subject(s)
Humans , Radiation Dosage , Tomography, X-Ray Computed , Sweat Glands , Radiography, Dental , Dental Implants
SELECTION OF CITATIONS
SEARCH DETAIL