1.
Chinese Journal of Infection Control ; (4): 341-346, 2018.
Article in Chinese | WPRIM | ID: wpr-701621

ABSTRACT

Objective To explore the retrograde contamination of drainage bag outlets,and provide basis for the formulation of related guideline for healthcare-associated infection(HAI)management. Methods On October 14,2016,with sterile manipulation,urine,5% glucose solution,glucose normal saline,sterile water,and 0.9% nor-mal saline were injected into anti-reflux drainage bags(anti-reflux group)and common drainage bags(common group)respectively,entrances of bags were sealed and bags were hung in two ways:outlets were 10 cm away from the ground(suspended group)and touched the ground(ground-touching group)respectively,specimens were col-lected from bag outlets to perform bacterial culture every 3 days,a total of 10 times of cultures were performed,re-trograde contamination of drainage bag outlets was observed dynamically.Results Retrograde contamination rate of drainage bag outlets of anti-reflux group was significantly lower than common group(7.7% vs 46.0%,P=0.000);suspended group was significantly lower than ground-touching group(17.9% vs 35.8%,P=0.000). Retrograde contamination rates of outlets of drainage bags filled with different properties of liquid were as follows:urine (54.3%)>5% glucose solution(34.5%)>glucose normal saline(24.3%)>0.9% normal saline(10.8%)>ste-rile water(10.5%),pairwise comparison showed a significant difference(P=0.000).The initial occurrence time of contamination in anti-reflux group and common group was on the 13thday and 7thday respectively,two group was significantly different on the 7thday(P=0.041). There was a medium intensity correlation between the types of drainage bags and liquid properties(PearsonC=0.5).Conclusion Different types of drainage bags,retention time,and liquid property can impact retrograde contamination of drainage bag outlets,regular urine culture during the use of drainage bags should be paid attention in clinical practice,so as to use antimicrobial agents rationally and guide replacement time of drainage bags.

2.
Chongqing Medicine ; (36): 4054-4056, 2017.
Article in Chinese | WPRIM | ID: wpr-659565

ABSTRACT

Objective To investigate the effects of urinary ostomy bag connected with disposable drainage bag on drainage of abdominal cavity after surgery on gastrointestinal tumor.Methods A total of 82 patients carried out drainage of the abdominal cavity after surgery on gastrointestinal tumor in Cancer Hospital of Jiangxi Province from January to December 2015 were selected and divided into control group (n=40) and observation group (n=42).During the period of abdominal cavity drainage,the control group was given routine dressing change.In addition to the conventional treatment of the drainage incision,the observation group utilized urinary ostomy bag connected with disposable drainage bag for drainage.The incidence rates of leakage and irritable dermatitis around abdominal drainage mouth,dressing times of drainage incision,healing time of drainage incision and patient comfort in drainage were compared between the two groups.Results At the end of abdominal cavity drainage,the incidence rates of leakage and irritable dermatitis around abdominal drainage mouth of the observation group were significantly lower than those of the control group (x2 =5.550,6.717;P=0.043,0.010);the dressing times of drainage incision in the observation group was significantly less than that in the control group (t=13.840,P=0.000);the healing time of drainage incision in the observation group was significantly shorter than that in the control group (t=6.854,P=0.000);the comfort in the observation group was significantly higher than that in the control group 0=7.429,P=0.000).Conclusion Urinary bag connected with disposable drainage bag for drainage after surgery on gastrointestinal tumor can effectively reduce the occurrence of leakage and irritable dermatitis around abdominal drainage mouth,improve patient comfort,it is worthy of clinical promotion.

3.
Chinese Medical Equipment Journal ; (6): 59-61, 2017.
Article in Chinese | WPRIM | ID: wpr-617265

ABSTRACT

Objective To develop a holding mechanism for the drainage bag to reduce the accident rate of tube falling off during CT examination.Methods The mechanism was composed of a bed body,a mobile bed board,a connecting board,a rod and kink section.CT bed board had a sandwich structure with carbon fibre composite and foam material,and the connecting board,kink section,rod and its hinge joint were made of polycarbonate material.Results The mechanism decreased the risk for tube falling off during CT examination and increased the patient comfort.Conclusion The mechanism gains advantages in stability,mobility,convenience and practicability,and thus is worthy promoting practically.

4.
Chinese Journal of Nursing ; (12): 901-904, 2017.
Article in Chinese | WPRIM | ID: wpr-611002

ABSTRACT

Objective To investigate the appropriate time of replacing drainage bags after trans-cervical resection of adhesion(TCRA) surgery.Methods Totally 156 patients underwent TCRA were randomly divided into three groups:Group A,the drainage bags were replaced daily;Group B,the drainage bags were replaced every 3 days;Group C,the drainage bags were never replaced.The drainage bags were removed on the 6th day after TCRA for all groups.Bacterial culture results from the balloon surface of drainage bag,outer cervical orifice,and the connector of drainage bag for 3 groups were observed.The positive rates of bacterial cultures were analyzed statistically.Results The bacterial culture results from the drainage bag connector of 3 groups indicated that the positive rate of Group C was significantly lower than that of other two groups(P<0.05).The bacterial culture from the drainage bag balloon surface also indicated the same result,but the result did not showed statistically significant difference(P>0.05).There was no statistically significant difference in the culture result firom outer cervical orifice and the volume of drainage fluid within three groups(P>0.05).Conclusion It is indicated that the patient may enjoy a lower rate of bacterial infection without replacing any drainage bags connected to balloon drainage tubes placed after TCRA within 6 days.We suggest that the intrauterine drainage hags may be kept without replacement until direct removing the drainage tube on day 6 after TCRA.

5.
Chongqing Medicine ; (36): 4054-4056, 2017.
Article in Chinese | WPRIM | ID: wpr-662203

ABSTRACT

Objective To investigate the effects of urinary ostomy bag connected with disposable drainage bag on drainage of abdominal cavity after surgery on gastrointestinal tumor.Methods A total of 82 patients carried out drainage of the abdominal cavity after surgery on gastrointestinal tumor in Cancer Hospital of Jiangxi Province from January to December 2015 were selected and divided into control group (n=40) and observation group (n=42).During the period of abdominal cavity drainage,the control group was given routine dressing change.In addition to the conventional treatment of the drainage incision,the observation group utilized urinary ostomy bag connected with disposable drainage bag for drainage.The incidence rates of leakage and irritable dermatitis around abdominal drainage mouth,dressing times of drainage incision,healing time of drainage incision and patient comfort in drainage were compared between the two groups.Results At the end of abdominal cavity drainage,the incidence rates of leakage and irritable dermatitis around abdominal drainage mouth of the observation group were significantly lower than those of the control group (x2 =5.550,6.717;P=0.043,0.010);the dressing times of drainage incision in the observation group was significantly less than that in the control group (t=13.840,P=0.000);the healing time of drainage incision in the observation group was significantly shorter than that in the control group (t=6.854,P=0.000);the comfort in the observation group was significantly higher than that in the control group 0=7.429,P=0.000).Conclusion Urinary bag connected with disposable drainage bag for drainage after surgery on gastrointestinal tumor can effectively reduce the occurrence of leakage and irritable dermatitis around abdominal drainage mouth,improve patient comfort,it is worthy of clinical promotion.

6.
Chinese Journal of Practical Nursing ; (36): 827-830, 2017.
Article in Chinese | WPRIM | ID: wpr-511663

ABSTRACT

Objective To compare the effects of adjustable pressure drainage device, negative pressure ball drainage and drainage bag drainage on patients with the total hip arthroplasty. Methods The silicone drainage ball with negative pressure, the urine collection bag, the infusion set′s regulator were used to make adjustable pressure drainage device. 120 cases of total hip arthroplasties from January to December in 2015 were chosed and divided randomly into 3 groups based on the sequence of operation notifications. In 40 cases, drainage bag were used (control group 1), 40 cases with negative pressure ball drainage (control group 2) and 40 cases with adjustable pressure drainage device (experimental group). Total postoperative bleeding, the blood transfusion amount, swelling (the thickness of hematoma) and the nursing workload of the three groups were compared. Results The total postoperative bleeding, the blood transfusion amount, the thickness of hematoma and the nursing workload in the experimental group were (775.1±130.5) ml, (3.5±1.3) mm, (180.2±29.9) ml, (34.5±5.2) min. The total postoperative bleeding, the blood transfusion amount, the thickness of hematoma and the nursing workload in the control group 1 were (889.4 ± 160.8) ml, (5.2 ± 1.1) mm, (285.9 ± 30.4) ml, (40.6 ± 7.4) min and in the control group 2 were (876.2±156.7) ml, (4.3±1.2) mm,(208.3±33.3) ml, (50.3±8.5) min. Compared the data of the experimental group and the control group 1, the difference was of statistically significance (t=3.49-15.68, P < 0.01). Compared the data of the experimental group and the control group 2, the difference was of statistically significance (t=2.86-10.03, P<0.01). Conclusions The effects of adjustable pressure drainage device are better than the drainage bag and negative pressure drainage ball. It can effectively reduce the postoperative bleeding and the swelling degree, and bring a lot of relief to the patients and lots of convenience to the nursing work. The method is affordable, reliable and safe which should be promoted in the primary hospital.

7.
Chinese Journal of Practical Nursing ; (36): 1-4, 2008.
Article in Chinese | WPRIM | ID: wpr-397611

ABSTRACT

Objective To study the appropriate changing frequency of urinary drainage bag for patients with indwelling catheters using anti-reflux drainage bag in urological surgical department. Methods Of 78 in-patients with indwelling catheters using anti-reflux drainage bags 40 patients were selected randomly as the experimental group with no bag change,38 patients as the control group with bag change every day.Bloody urine samples were obtained from each drainage bag for germicuhure ev-ery day. Results Under situations of no difference existed in general information, duration of in-dwelling catheters,volume of drinking and urine and times of opening valve,the positive rate of urine germiculture was 7.5% and 10.5%( P>0.05 ),the incidence of symptomatic urinary tract infection (U-TI) was 2.5% and 2.6% in the experimental group and the control group (P>0.05). Conclusions There is no evidence for the necessity of anti-reflux drainage bag change every day for patients with in-dwelling catheters and bloody urine after operation in the urological surgical department. However the appropriate frequency of urinary drainage bag change needs additional study.

SELECTION OF CITATIONS