Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Korean Journal of Pediatrics ; : 158-164, 2005.
Article in Korean | WPRIM | ID: wpr-47003

ABSTRACT

PURPOSE: We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, Koln, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. METHODS: Two hundred and five patients who underwent percutaneous PDA occlusion using Duct- Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. RESULTS: The rate of residual shunt according to the type of Duct-Occlud were as follows: S-54%, R-72%, RR-50%, N-14%(P4 mm). CONCLUSION: The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.


Subject(s)
Humans , Ductus Arteriosus, Patent , Follow-Up Studies , Physical Examination
2.
Korean Journal of Pediatrics ; : 36-43, 2004.
Article in Korean | WPRIM | ID: wpr-211017

ABSTRACT

PURPOSE: We will present our mid-term result of transcatheter closure of PDA with Duct-Occlud device(pfm. AG. Germany) after 12 months follow up and report the problems during the procedure. METHODS: In total 154 patients, the Duct-Occlud devices were inserted in our institute from March, 1996 to August, 2002. Three types of Duct-Occlud device, i.e standard, reinforced, reinforced reverse cone coil were used. Echocardiographic examination was performed at 1, 6, 12 months after procedure. RESULTS: The echocardiographic closure rate was 96% after 12 months. The rates of residual shunt in the standard coil, the reverse cone coil, and the reinforced reverse cone group were 8%, 4% and 3% respectively. In PDA with diameter less than 4 mm, the closure rate was up to 98% while in large PDA with more than 4 mm, it was 72% after 12 months. Embolization of the inserted coils had occurred in 5 cases with successful retrieval using snare catheter. The rupture of the core wire during the procedure and distortion of the original coil shape had occurred in 4 cases. CONCLUSION: The transcatheter occlusion with Duct Occlud is safe and effective method for small to moderate sized PDA less than 4 mm. The minimum diameter of the PDA seems to be the predictor of residual shunt. Further refinement of the device to overcome the procedure-related problems seems to be needed.


Subject(s)
Humans , Catheters , Ductus Arteriosus, Patent , Echocardiography , Follow-Up Studies , Rupture , SNARE Proteins