Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Arq. bras. cardiol ; 121(2): e20230222, 2024. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1533741

ABSTRACT

Resumo Os fibroelastomas são o segundo tumor cardíaco benigno mais comum. São estruturas pequenas, avasculares, com uma dimensão média de 9mm, podendo atingir até 70mm, habitualmente aderentes à superfície das válvulas cardíacas (válvulas aórtica e mitral são as mais comumente afetadas, seguidas das válvulas tricúspide e pulmonar). A etiologia não é clara, sendo a hipótese de formação de microtrombos nas margens de coaptação das válvulas a mais aceite. Na ecocardiografia apresentam aspeto pediculado, móvel, com superfície filamentosa, tipicamente com uma aparência pontilhada nas margens e ecolucente. Do ponto de vista clínico, podem estar associados a fenómenos embólicos, no entanto, na maioria dos casos o diagnóstico é incidental. Apresentamos de seguida quatro casos de diagnóstico incidental de fibroelastomas nas quatro válvulas cardíacas, diagnosticados por ecocardiograma transtorácico (ETT) (Vídeo 1; Figura 1). Vídeo 1 Da esquerda para a direita, de cima para baixo: fibroelastomas no folheto anterior da válvula tricúspide, folheto anterior da válvula mitral, cúspide esquerda da válvula pulmonar e cúspide esquerda da válvula aórtica, cada um correspondendo a um doente diferente. Em: http://abccardiol.org/supplementary-material/2024/12102/2023-0222_IM_video01.mp4 Figura 1 Da esquerda para a direita, de cima para baixo: fibroelastomas no folheto anterior da válvula tricúspide, folheto anterior da válvula mitral, cúspide esquerda da válvula pulmonar e cúspide esquerda da válvula aórtica, cada um correspondendo a um doente diferente.


Abstract Fibroelastomas are the second most common benign cardiac tumor1. They are small avascular structures with a mean size of 9mm, ranging up to 70mm, usually attached to the heart valves' surface (aortic and mitral are the most affected, followed by tricuspid and pulmonary valves). Their etiology is unclear, but the hypothesis of coalescence of microthrombus at the coaptation margins of valves is the most widely accepted theory. On echocardiography, they are pedicled, mobile, with a filamentous surface, and usually have a speckled appearance with echolucencies and a stippled pattern near the edges. Clinically, they may be associated with embolic phenomena; however, in most cases, the diagnosis is incidental. We present a series of four clinical cases with an incidental diagnosis of fibroelastomas across the four cardiac valves as assessed by transthoracic echocardiography (Video 1; Figure 1). Video 1 From left to right and top to bottom: fibroelastomas of the anterior leaflet of the tricuspid valve, anterior leaflet of the mitral valve, left cusp of the pulmonary valve and left cuspid of the aortic valve, each corresponding to a different patient. Link: http://abccardiol.org/supplementary-material/2024/12102/2023-0222_IM_video01.mp4 Figure 1 From left to right and top to bottom: fibroelastomas of the anterior leaflet of the tricuspid valve, anterior leaflet of the mitral valve, left cusp of the pulmonary valve and left cuspid of the aortic valve, each corresponding to a different patient.

3.
Arq. bras. cardiol ; 115(3): 515-524, out. 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131307

ABSTRACT

Resumo Fundamento A intervenção percutânea em pacientes com disfunção de prótese biológica mitral apresenta-se como uma alternativa ao tratamento cirúrgico convencional. Objetivo Relatar a primeira experiência brasileira de implante transcateter de bioprótese valve-in-valve mitral via transeptal (TMVIV-via transeptal). Métodos Foram incluídos pacientes portadores de disfunção de bioprótese cirúrgica submetidos ao TMVIV-transeptal em 12 hospitais brasileiros. Foram considerados estatisticamente significativos valores de p<0,05. Resultados Entre junho/2016 e fevereiro/2019, 17 pacientes foram submetidos ao TMVIV-via transeptal. A mediana de idade foi 77 anos (IIQ,70-82), a mediana do escore STS-PROM foi 8,7% (IIQ,7,2-17,8). Todos os pacientes tinham sintomas limitantes de insuficiência cardíaca (CF≥III), tendo 5 (29,4%) sido submetidos a mais de uma toracotomia prévia. Obteve-se sucesso do TMVIV-via transeptal em todos os pacientes. A avaliação ecocardiográfica demonstrou redução significativa do gradiente médio (pré-intervenção, 12±3,8 mmHg; pós-intervenção, 5,3±2,6 mmHg; p<0,001), assim como aumento da área valvar mitral (pré-intervenção, 1,06±0,59 cm2; pós-intervenção, 2,18±0,36 cm2; p<0,001) sustentados em 30 dias. Houve redução significativa e imediata da pressão sistólica de artéria pulmonar, com redução adicional em 30 dias (pré-intervenção, 68,9±16,4 mmHg; pós-intervenção, 57,7±16,5 mmHg; 30 dias, 50,9±18,7 mmHg; p<0,001). Durante o seguimento, com mediana de 162 dias (IIQ, 102-411), observou-se marcada melhora clínica (CF≤II) em 87,5%. Um paciente (5,9%) apresentou obstrução de via de saída de ventrículo esquerdo (VSVE), evoluindo para óbito logo após o procedimento, e outro morreu aos 161 dias de seguimento.Conclusão: A primeira experiência brasileira de TMVIV-transeptal demonstra a segurança e a efetividade dessa nova técnica. A obstrução da VSVE é uma complicação potencialmente fatal, reforçando a importância da seleção dos pacientes e do planejamento do procedimento. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Percutaneous intervention in patients with bioprosthetic mitral valve dysfunction is an alternative to conventional surgical treatment. Objectives To report the first Brazilian experience with transseptal transcatheter bioprosthetic mitral valve-in-valve implantation (transseptal-TMVIV). Methods Patients with surgical bioprosthetic dysfunction submitted to transseptal-TMVIV in 12 Brazilian hospitals were included. The significance level adopted was p<0.05. Results From June/2016 to February/2019, 17 patients underwent transseptal-TMVIV. Their median age was 77 years (IQR,70-82) and median Society of Thoracic Surgeons predicted risk of mortality (STS-PROM) score was 8.7% (IQR,7.2-17.8). All patients had limiting symptoms of heart failure (FC≥III) and 5 (29.4%) had undergone more than one previous thoracotomy. Transseptal-TMVIV was successful in all patients. Echocardiographic assessment showed a significant reduction in mean mitral valve gradient (pre-intervention, 12±3.8 mmHg; post-intervention, 5.3±2.6 mmHg; p<0.001), in addition to an increase in mitral valve area (pre-intervention, 1.06±0.59 cm2; post-intervention, 2.18±0.36 cm2; p<0.001) sustained for 30 days. There was a significant and immediate reduction in the pulmonary artery systolic pressure, with an additional reduction in 30 days (pre-intervention, 68.9±16.4 mmHg; post-intervention, 57.7±16.5 mmHg; 30 days, 50.9±18.7 mmHg; p<0.001). During follow-up (median, 162 days; IQR, 102-411), significant clinical improvement (FC≤II) was observed in 87.5% of the patients. One patient (5.9%) had left ventricular outflow tract (LVOT) obstruction and died right after the procedure, and another died at 161 days of follow-up. Conclusion The first Brazilian experience with transseptal-TMVIV shows the safety and effectivity of the new technique. The LVOT obstruction is a potentially fatal complication, reinforcing the importance of patients' selection and of procedural planning. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aged , Aged, 80 and over , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/surgery , Prosthesis Design , Brazil , Cardiac Catheterization , Treatment Outcome , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
6.
Rev. urug. cardiol ; 34(2): 51-70, ago. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1014546

ABSTRACT

Resumen: Introducción: los defectos del septum interauricular (SIA) son frecuentes. En los últimos años se ha identificado una nueva entidad conocida comoseptal pouch (SP). Los datos sobre su prevalencia son escasos, estimándose entre 30%-50% en la población general. El rol como fuente de cardioembolia es discutido. Objetivos: el objetivo primario es determinar la prevalencia y caracterizar el SP; en forma secundaria, definir la variabilidad interobservador para su diagnóstico. Material y método: estudio observacional, descriptivo y analítico. Se reclutaron en forma prospectiva pacientes consecutivos derivados para ecocardiograma transesofágico (ETE) entre el 20 de abril de 2018 y el 30 de agosto de 2018. Se registraron datos patronímicos, antecedentes personales de accidente cerebrovascular (ACV), ritmo cardíaco y motivo del estudio. Se evaluó la presencia de SP y se caracterizó como left-sided septal pouch (LSSP) o rigth-sided septal pouch (RSSP); se midió profundidad, presencia de trombo en su interior y se completó el estudio ecocardiográfico. Las imágenes fueron evaluadas por dos ecocardiografistas ciegos entre sí. Las variables cualitativas se presentan en frecuencia relativa (FR); las cuantitativas en mediana e intervalo intercuartilo. Se realizó test de chi cuadrado para evaluar la asociación entre la presencia de SP y la presencia de ACV o de FA. La reproducibilidad del diagnóstico de SP fue evaluada por índice Kappa. Resultados: se incluyeron 50 sujetos. La prevalencia de SP fue de 0,5 (FR), 0,46 LSSP y 0,04 RSSP. El índice Kappa interobservador para el diagnóstico fue 0,68, error estándar 0,14, con 84% de acuerdo. Catorce sujetos tenían antecedente de ACV, en nueve de ellos se diagnosticó SP (chi cuadrado p=0,21); 18 pacientes tenían fibrilación auricular/flutter, la mitad de ellos tenía SP (chi cuadrado p=1). Conclusión: la prevalencia de SP fue de la mitad de la población, predominando ampliamente el LSSP, con buena reproducibilidad en su diagnóstico. Se trata de un hallazgo subdiagnosticado; interesa continuar investigando su posible asociación con ACV.


Summary: Introduction: the interatrial septum defects are frequent. A new entity has recently been identified, known as septal pouch. Prevalence data in general population is scarce, and is estimated between 30%-50%. The role as a source of cardioembolism is unclear. Objectives: the primary objective is to determine the prevalence and characterize the septal pouch; secondarily to define the interobserver variability for the diagnosis. Material and methods: observational, descriptive and analytical study. Consecutive patients were recruited for transesophageal echocardiography between 4/20/2018 and 8/30/2018. We recorded patronymic data, personal history of stroke, heart rate, and the reason for the study. The presence of septal pouch was defined and characterized as left-sided septal pouch or rigth-sided septal pouch; depth was measured, presence of thrombus inside and echocardiographic study measures were completed. The images were evaluated by two blind echocardiographers. The qualitative variables are presented in relative frequency (RF), the quantitative variables in median and interquartile interval. Chi square test was carried out. The reproducibility of the diagnosis of septal pouch was evaluated by Kappa index. Results: 50 subjects were included. The prevalence of septal pouch was 0.5 (RF), 0.46 left-sided septal pouch and 0.04 rigth-sided septal pouch. The interobserver Kappa index for diagnosis is 0.68, standard error 0.14, with 84% agreement. 14 subjects had stroke, in 9 of them septal pouch was diagnosed (chi square p=0.21); 18 patients had atrial fibrillation or flutter, half of them had septal pouch (chi square p=1). Conclusion: the prevalence of septal pouch was half of the population, predominantly the left-sided septal pouch, with good reproducibility in diagnosis. It is an underdiagnosed finding; further investigation is necessary to assess its relation to stroke.


Resumo: Introdução: os defeitos do septo interatrial são freqüentes. Nos últimos anos, uma nova entidade conhecida como bolsa septal foi identificada. Dados sobre prevalência são escassos, estimados em 30%-50% na população geral. O papel como fonte de cardioembolismo é discutido. Objetivos: o objetivo primário é determinar a prevalência e caracterizar a bolsa septal; secundariamente definir a variabilidade interobservador para o seu diagnóstico. Material e métodos: estudo observacional, descritivo e analítico. Consecutivos pacientes foram recrutados para ecocardiograma transesofágico entre 20/4/2018 e 30/08/2018. Registramos dados patronímicos, histórico pessoal de acidente vascular cerebral, frequência cardíaca e o motivo do estudo. A presença de bolsa septal foi definida e caracterizada como bolsa septal esquerda ou bolsa septal direita; a profundidade foi medida, a presença de trombo no interior e o estudo ecocardiográfico foram concluídos. As imagens foram avaliadas por dois ecocardiografistas cegos. As variáveis qualitativas são apresentadas em frequência relativa (FR); os quantitativos em mediana e interquartil intervalo. O teste do qui quadrado foi realizado. A reprodutibilidade do diagnóstico de bolsa septal foi avaliada pelo índice Kappa. Resultados: 50 sujeitos foram incluídos. A prevalência de bolsa septal foi de 0,5 (FR), 0,46 bolsa septal esquerda e 0,04 bolsa septal direita. O índice Kappa interobservador para diagnóstico é 0,68, erro padrão 0,14, com 84% de concordância. 14 sujeitos apresentaram acidente vascular cerebral, em 9 deles foi diagnosticada bolsa septal (qui-quadrado p=0,21); 18 pacientes apresentaram fibrilhação auricular / flutter, metade deles com bolsa septal (qui quadrado p=1). Conclusão: a prevalência de bolsa septal foi metade da população, predominantemente a bolsa septal esquerda, com boa reprodutibilidade em seu diagnóstico. É um achado subdiagnosticado; é interessante para continuar investigando sua possível associação com acidente vascular cerebral.

8.
Rev. Col. Bras. Cir ; 45(2): e1659, 2018. tab, graf
Article in English | LILACS | ID: biblio-896641

ABSTRACT

ABSTRACT Objective: to demonstrate hemodynamic changes during laparoscopic cholecystectomy in elderly patients with trans-esophageal echocardiography. Methods: we studied 31 elderly patients (aged 60 years or older), ASA I or II, who underwent elective laparoscopic cholecystectomy under general, standardized anesthesia, with cardiovascular parameters measured using transesophageal echocardiography at three different times: before the pneumoperitoneum (T1), after CO2 insufflation (T2) and at deflation (T3). We statistically evaluated changes in systolic, diastolic and mean blood pressure, heart rate, cardiac output and index, and ejection fraction. Results: although small, only the diastolic blood pressure (DBP) and ejection fraction (EF) variations were statistically significant. The mean ± standard deviation of DBP in mmHg at the different times were: T1=67.5±10.3; T2=73.6±12.4; and T3=66.7±9.8. And for EF, in percentage (%) they were: T1=66.7±10.4; T2=63.2±9.9; and T3=68.1±8.4. There was no statistical correlation between hemodynamic variations, age and number of patients' comorbidities. Conclusion: laparoscopic cholecystectomy causes few hemodynamic changes that are well tolerated by the majority of the elderly patients; prior impairment of ventricular function represents a threat in elderly patients during surgery; there appears to be a lower hemodynamic effect caused by the pneumoperitoneum than by the patient's positioning in a reverse Trendelemburg during surgery.


RESUMO Objetivo: demonstrar as alterações hemodinâmicas durante a colecistectomia laparoscópica em pacientes idosos com auxílio da ecocardiografia trans-esofágica Métodos: foram estudados trinta e um pacientes idosos (com 60 anos de idade ou mais), ASA I ou II, submetidos à colecistectomia laparoscópica eletiva, sob anestesia geral padronizada, com aferição de parâmetros cardiovasculares através de ecocardiograma trans-esofágico em três momentos diferentes: antes do pneumoperitônio (T1), após a insuflação do CO2 (T2) e na desinsuflação (T3). As variações da pressão arterial sistólica, diastólica e média, da frequência cardíaca, do débito e do índice cardíaco, e da fração de ejeção foram avaliadas estatisticamente. Resultados: apesar de pequenas, somente as variações da pressão arterial diastólica (PAD) e da fração de ejeção (FE) foram estatisticamente significativas. A PAD, em mmHg, nos diferentes momentos, de acordo com a média e desvio padrão, foram: T1=67,5±10,3; T2=73,6±12,4; T3=66,7±9,8. E para a FE, em porcentagem (%), nos diferentes momentos, de acordo com média e desvio padrão, foram: T1=66,7±10,4; T2=63,2±9,9; T3=68,1±8,4. Não houve correlação estatística entre as variações hemodinâmicas, a idade e número de comorbidades dos pacientes. Conclusão: a colecistectomia laparoscópica causa poucas alterações hemodinâmicas que são bem toleradas pela maioria dos pacientes idosos; o comprometimento prévio da função ventricular representa ameaça em pacientes idosos durante a cirurgia; parece haver menor efeito hemodinâmico causado pelo pneumoperitônio do que pelo posicionamento do paciente em Trendelemburg reverso durante a cirurgia.


Subject(s)
Humans , Male , Female , Aged , Monitoring, Intraoperative , Cholecystectomy, Laparoscopic , Hemodynamics , Echocardiography, Transesophageal , Middle Aged
9.
Arq. bras. cardiol ; 107(4): 305-313, Oct. 2016. tab
Article in English | LILACS | ID: biblio-827859

ABSTRACT

Abstract Background: Atrial fibrillation (AF) is the most common arrhythmia seen in adults. Atrial stunning is defined as the temporary mechanical dysfunction of the atrial appendage developing after AF has returned to sinus rhythm (SR). Objectives: We aimed to evaluate atrial contractile functions by strain and strain rate in patients with AF, following pharmacological and electrical cardioversion and to compare it with conventional methods. Methods: This study included 41 patients with persistent AF and 35 age-matched control cases with SR. All the AF patients included in the study had transthoracic and transesophageal echocardiography performed before and after. Septum (SEPsSR), left atrium (LAsSR) and right atrium peak systolic strain rate (RAsSR) were defined as the maximum negative value during atrial contraction and septum (SEPε), left atrium (LAε) and right atrium peak systolic strain (RAε) was defined as the percentage of change. Parameters of two groups were compared. Results: In the AF group, 1st hour and 24th hour LAε, RAε, SEPε, LAsSR, RAsSR, SEPsSR found to be significantly lower than in the control group (LAε: 2.61%±0.13, 3.06%±0.19 vs 6.45%±0.27, p<0.0001; RAε: 4.03%±0.38, 4.50%±0.47 vs 10.12%±0.64, p<0.0001; SEPε: 3.0%±0.22, 3.19%±0.15 vs 6.23%±0.49, p<0.0001; LAsSR: 0.61±0.04s-1, 0.75±0.04s- 1 vs 1.35±0.04s-1, p<0.0001; RAsSR: 1.13±0.06s-1, 1.23±0.07s-1 vs 2.10±0.08s- 1, p<0.0001; SEPsSR: 0.76±0.04s- 1, 0.78±0.04s- 1 vs 1.42±0.06 s- 1, p<0.0001). Conclusion: Atrial strain and strain rate parameters are superior to conventional echocardiographic parameters for the evaluation of atrial stunning in AF cases where SR has been achieved.


Resumo Fundamento: A fibrilação atrial (FA) é a arritmia mais comum em adultos. Define-se atordoamento atrial como a disfunção mecânica temporária do apêndice atrial que se desenvolve depois de reversão da FA ao ritmo sinusal (RS). Objetivos: Avaliar as funções atriais contráteis através de strain atrial e strain rate em pacientes com FA, após cardioversão farmacológica e elétrica, assim como compará-los com os métodos convencionais. Métodos: Este estudo incluiu 41 pacientes com FA persistente e 35 controles com RS e pareados por idade. Todos os pacientes com FA incluídos neste estudo foram submetidos a ecocardiografia transtorácica e transesofágica antes e após. Strain rates de pico sistólico do septo (SEPsSR), do átrio esquerdo (LAsSR) e do átrio direito (RAsSR) foram definidas como o máximo valor negativo durante contração atrial. Strains de pico sistólico do septo (SEPε), do átrio esquerdo (LAε) e do átrio direito (RAε) foram definidas como porcentagem de mudança. Resultados: No grupo com FA, os parâmetros LAε, RAε, SEPε, LAsSR, RAsSR e SEPsSR da 1a hora e da 24a hora foram significativamente mais baixos que no grupo controle (LAε: 2,61%±0,13; 3,06%±0,19 vs 6,45%±0,27; p<0,0001; RAε: 4,03%±0,38; 4,50%±0,47 vs 10,12%±0,64; p<0,0001; SEPε: 3,0%±0,22; 3,19%±0,15 vs 6,23%±0,49; p<0,0001; LAsSR: 0,61±0,04s-1; 0,75±0,04s-1 vs 1,35±0,04s-1; p<0,0001; RAsSR: 1,13±0,06s-1; 1,23±0,07s-1 vs 2,10±0,08s-1; p<0,0001; SEPsSR: 0,76±0,04s-1; 0,78±0,04s-1 vs 1,42±0,06 s-1; p<0,0001). Conclusão: Os parâmetros strain atrial e strain rate são superiores aos parâmetros ecocardiográficos convencionais para avaliar atordoamento atrial em pacientes com FA que reverteram ao RS.


Subject(s)
Humans , Male , Female , Middle Aged , Atrial Fibrillation/complications , Atrial Fibrillation/physiopathology , Atrial Function/physiology , Myocardial Stunning/physiopathology , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnostic imaging , Stroke Volume/physiology , Systole/physiology , Time Factors , Electric Countershock/methods , Echocardiography , Reproducibility of Results , Myocardial Stunning/diagnostic imaging , Statistics, Nonparametric , Atrial Appendage/diagnostic imaging
11.
Arq. bras. cardiol ; 107(1): 55-62, July 2016. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-792497

ABSTRACT

Abstract Background: Paravalvular regurgitation (paravalvular leak) is a serious and rare complication associated with valve replacement surgery. Studies have shown a 3% to 6% incidence of paravalvular regurgitation with hemodynamic repercussion. Few studies have compared surgical and percutaneous approaches for repair. Objectives: To compare the surgical and percutaneous approaches for paravalvular regurgitation repair regarding clinical outcomes during hospitalization and one year after the procedure. Methods: This is a retrospective, descriptive and observational study that included 35 patients with paravalvular leak, requiring repair, and followed up at the Dante Pazzanese Institute of Cardiology between January 2011 and December 2013. Patients were divided into groups according to the established treatment and followed up for 1 year after the procedure. Results: The group submitted to percutaneous treatment was considered to be at higher risk for complications because of the older age of patients, higher prevalence of diabetes, greater number of previous valve surgeries and lower mean creatinine clearance value. During hospitalization, both groups had a large number of complications (74.3% of cases), with no statistical difference in the analyzed outcomes. After 1 year, the percutaneous group had a greater number of re-interventions (8.7% vs 20%, p = 0.57) and a higher mortality rate (0% vs. 20%, p = 0.08). A high incidence of residual mitral leak was observed after the percutaneous procedure (8.7% vs. 50%, p = 0.08). Conclusion: Surgery is the treatment of choice for paravalvular regurgitation. The percutaneous approach can be an alternative for patients at high surgical risk.


Resumo Fundamento: Regurgitação ou escape paravalvar é uma complicação grave e incomum associada ao implante de prótese valvar. Estudos mostram incidência de 3% a 6% com repercussão hemodinâmica. Existem poucos estudos na literatura que comparam as abordagens cirúrgica e percutânea para sua correção. Objetivos: Comparar as abordagens cirúrgica e percutânea de correção da regurgitação paravalvar quanto a desfechos clínicos durante a internação e após 1 ano do procedimento. Métodos: Este é um estudo retrospectivo, descritivo e observacional, que incluiu 35 pacientes com escape paravalvar acompanhados no Instituto Dante Pazzanese de Cardiologia entre janeiro de 2011 e dezembro de 2013 e que necessitaram de correção. Os pacientes foram divididos de acordo com o tratamento estabelecido e acompanhados por um período 1 ano após o procedimento. Resultados: O grupo submetido ao tratamento percutâneo foi considerado como de maior risco para complicações por apresentar pacientes mais idosos, com maior prevalência de diabetes, maior quantidade de cirurgias valvares prévias e menor valor médio de clearance de creatinina. Durante a evolução intra-hospitalar, observou-se grande número de complicações nos dois grupos (74,3% dos casos), sem diferença estatística nos desfechos analisados. Após 1 ano, o grupo percutâneo teve maior número de reintervenções (8,7% vs. 20%, p = 0,57) e mortalidade maior (0% vs. 20%, p = 0,08). Uma alta incidência de escape residual mitral foi verificada após procedimento percutâneo (8,7% vs. 50%, p = 0,08). Conclusão: A cirurgia é o tratamento de escolha da regurgitação paravalvar. A abordagem percutânea pode ser uma alternativa para os pacientes com risco cirúrgico elevado.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Percutaneous Coronary Intervention/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Aortic Valve/surgery , Aortic Valve Insufficiency/mortality , Postoperative Complications/surgery , Postoperative Complications/mortality , Reoperation , Time Factors , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Therapeutic Occlusion/methods , Therapeutic Occlusion/mortality , Percutaneous Coronary Intervention/mortality , Hospitalization , Mitral Valve/surgery , Mitral Valve Insufficiency/mortality
14.
ABC., imagem cardiovasc ; 27(2): 83-86, abr.-jun. 2014. tab, graf
Article in English, Spanish, Portuguese | LILACS | ID: lil-715142

ABSTRACT

Introdução: O ecocardiograma transesofágico é atualmente uma das principais ferramentas no diagnóstico de diversas alterações cardíacas. Para uma maior segurança e conforto na sua realização, o exame tem sido realizado sob sedação consciente moderada, sendo os benzodiazepínicos os agentes de escolha. Nessa classe de medicamentos, o midazolam é o mais utilizado, todavia não está isento de possíveis complicações relacionadas ao seu uso, como hipóxia, hipotensão, entre outras. Sabemos que grau de sedação é dose-dependente, portanto, quanto menor a dose utilizada, será menor o risco de complicações do procedimento.Objetivo: Verificar o impacto do uso do fentanil na administração endovenosa de midazolam, no intuito de avaliar eficiência de protocolo de sedação de pacientes submetidos a ecocardiograma transesofágico, utilizando ambos os medicamentos. Metodologia: : Estudamos 201 pacientes (idade média de 51,5 anos, 115 homens) submetidos a ecocardiograma transesofágico, com sedação por via endovenosa divididos em dois grupos: Grupo A (n = 89), seguindo protocolo definido com uso de fentanil associado ao midazolam; e Grupo B (n = 112), sem o emprego de fentanil. Comparou-se então a dosagem de midazolam administrada em ambos os grupos. Monitorização adequada dos sinais vitais foi realizada durante todo o procedimento. Resultados: A dose média de midazolam utilizada foide 2,6 ± 1,4 mg no Grupo A e de 4,0 ± 2,7 mg no Grupo B (p < 0,01). A dose de fentanil empregada foi de 66,2 ± 24,8 mcg. Não houve diferença significativa entre idade (p = 0,08) e gênero (p > 0,1) nos grupos estudados. Conclusão: O uso de fentanil na sedação para realização de ecocardiograma transesofágico associado à administração de midazolam permite a administração de uma dose menor desse benzodiazepínico.


Introduction: Transesophageal echocardiography is currently one of the main tools in the diagnosis of various cardiac abnormalities. For greater safety and comfort, the test has been performed under moderate conscious sedation and benzodiazepines were the agents of choice. In this class of drugs, midazolam is the most commonly used, however it is not free of potential complications related to its use, such as hypoxia, hypotension, among others. We know that sedation level is dose-dependent. Therefore, the lower the dose, the lower the risk of complications from the procedure.Objective: To check the impact of fentanyl in the intravenous administration of midazolam in order to assess the sedation protocol efficiency on patients undergoing transesophageal echocardiography using both drugs.Methodology: We have studied 201 patients (mean age 51.5 years, 115 men) who underwent transesophageal echocardiography with intravenous sedation divided into two groups: Group A (n = 89), following the protocol with fentanyl associated with midazolam; and Group B (n = 112) without the use of fentanyl. The dose of midazolam administered in both groups was then compared. Proper monitoring of vital signs was performed throughout the procedure.Results: The mean dose of midazolam used was 2.6 ± 1.4 mg in Group A and 4.0 ± 2.7 mg in Group B (p < 0.01). The dose of fentanyl used was 66.2 ± 24.8 mcg. There was no significant difference between age (p = 0.08) and gender (p > 0.1) in the groups studied. Conclusion: The use of fentanyl in sedation for transesophageal echocardiography associated with administration of midazolam allows the administration of a lower dose of this benzodiazepine.


Introducción: El ecocardiograma transesofágico es actualmente una de las principales herramientas en el diagnóstico de diversas alteraciones cardíacas. Para una mayor seguridad y confort en su realización, el examen ha sido realizado bajo sedación conciente moderada, siendo los benzodiazepínicos los agentes de elección. En esa clase de medicamentos, el midazolam es el más utilizado, sin embargo no está exento de posibles complicaciones relacionadas a su uso, como hipoxia, hipotensión, entre otras. Sabemos que grado de sedación es dosis-dependiente, por lo tanto, cuanto menor es la dosis utilizada, será menor el riesgo de complicaciones del procedimiento.Objetivo: Verificar el impacto del uso del fentanil en la administración endovenosa de midazolam, con el propósito de evaluar eficiencia de protocolo de sedación de pacientes sometidos a ecocardiograma transesofágico, utilizando ambos medicamentos.Metodología: Estudiamos 201 pacientes (edad media de 51,5 anos, 115 hombres) sometidos a ecocardiograma transesofágico, con sedación por vía endovenosa divididos en dos grupos: Grupo A (n = 89), siguiendo protocolo definido con uso de fentanil asociado al midazolam; y Grupo B (n = 112), sin el empleo de fentanil. Se comparó entonces el dosaje de midazolam administrada en ambos grupos. Monitoreo adecuado de los signos vitales fue realizada durante todo el procedimiento. Resultados: La dosis media de midazolam utilizada fue de 2,6 ± 1,4 mg en el Grupo A y de 4,0 ± 2,7 mg en el Grupo B (p < 0,01). La dosis de fentanil empleada fue de 66,2 ± 24,8 mcg. No hubo diferencia significativa entre edad (p = 0,08) y género (p > 0,1) en los grupos estudiados. Conclusión: El uso de fentanil en la sedación para realización de ecocardiograma transesofágico asociado a la administración de midazolam permite la administración de una dosis menor de ese benzodiazepínico


Subject(s)
Humans , Male , Female , Middle Aged , Echocardiography, Transesophageal/adverse effects , Echocardiography, Transesophageal/methods , Fentanyl/adverse effects , Midazolam/adverse effects , Receptors, GABA-A , Body Mass Index
15.
Rev. Col. Bras. Cir ; 40(5): 357-362, set.-out. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-698070

ABSTRACT

OBJETIVO: avaliar as taxas de mortalidade e morbidade de doentes submetidos à revascularização do miocárdio (RVM) com circulação extracorpórea (CEC) que utilizaram rotineiramente o ecocardiograma transesofágico intraoperatório (ETEio). MÉTODOS: estudo retrospectivo, observacional com avaliação de prontuários de 360 doentes no período entre abril de 2010 a abril de 2012. Foram analisados: idade, peso, altura sexo, EUROscore, diabete melito, fração de ejeção e artérias acometidas. Os desfechos foram compilados no intra e no pós-operatório (infarto do miocárdio, acidente vascular cerebral, disfunção renal, hemodiálise, fibrilação atrial, tempo de internação no centro de tratamento intensivo). RESULTADOS: foram incluídos 53 doentes, com 27 recebendo a monitoração. Foram excluídos 307 porque não foram operados pela mesma equipe cirúrgica. Os dois grupos foram homogêneos quanto a idade, peso e sexo, porém, a fração ejeção foi menor no grupo que recebeu o ecotransesofágico (G ETEio: 56,3%; G Não ETEio: 65,9% ± 11; p=0,01). Nos doentes em que não foi utilizado o ETEio, a mortalidade foi maior (G ETEio: 0% e G Não ETEio: 7,6%; p=0,01). Não houve diferença significativa entre os grupos quanto à incidência de acidente vascular encefálico, infarto agudo do miocárdio, fibrilação atrial aguda e lesão renal. CONCLUSÃO: a utilização do ecocardiograma transesofágico intraoperatório em pacientes submetidos à revascularização do miocárdio, com circulação extracorpórea, diminuiu a mortalidade perioperatória; orientou quanto a utilização dos fármacos inotrópicos e vasodilatadores e contribuiu para uma melhor evolução dos doentes.


OBJECTIVE: To evaluate the rates of mortality and morbidity in patients undergoing coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB) using routine intraoperative transesophageal echocardiography (ITEE). METHODS: We conducted a retrospective, observational review of medical records of 360 patients from April 2010 to April 2012. We analyzed: age, weight, height, gender, EuroSCORE, diabetes mellitus, ejection fraction and number of diseased vessels. Outcomes were compiled in intraoperative and postoperative (myocardial infarction, stroke, renal failure, hemodialysis, atrial fibrillation, length of stay in the intensive care unit). RESULTS: 53 patients were included, with 27 receiving monitoring; we excluded 307 individuals, as they were not operated by the same surgical team. The two groups were homogeneous for age, weight and gender. However, the ejection fraction was lower in the group submitted to ITEE (ITEE group 56.3% versus Non-ITEE group 65.9 ± 11%, p = 0.01). In patients not subjected to ITEE, mortality was higher (ITEE group 0% versus Non-ITEE group 7.6%, p = 0.01). There was no significant difference between groups as for the incidence of stroke, myocardial infarction, atrial fibrillation and acute kidney injury. CONCLUSION: The use of intraoperative transesophageal echocardiography in patients undergoing coronary artery bypass grafting with cardiopulmonary bypass decreased perioperative mortality, warranted the use of inotropic drugs and vasodilators and contributed to a better patient outcome.


Subject(s)
Female , Humans , Male , Middle Aged , Cardiopulmonary Bypass , Coronary Artery Bypass/mortality , Coronary Artery Disease/surgery , Coronary Artery Disease , Echocardiography, Transesophageal , Monitoring, Intraoperative , Atrial Fibrillation , Retrospective Studies
16.
Rev. bras. ecocardiogr. imagem cardiovasc ; 24(4): 93-94, out.-dez. 2011. ilus
Article in Portuguese | LILACS | ID: lil-605349

ABSTRACT

The Eustachian valve (EV) is an embryonic remnant of the valve of the inferior vena cava (IVC). In some cases, the EV can be prominent and presenting as a thin, elongated and ecodense membrane, superimposed to the septal aspect of the RA, below the fossaovalis, partially dividing the RA in two chambers. Echocardiography is the method of choice for the diagnosis of this finding. The correct identification of this anatomic variant is very important for the differential diagnosis of the masses and tumors in the RA. Inpatients referred for cardiac surgery, as in the closure of atrial septal defects (ASD), it is fundamental the identification of this structureto avoid complications as the inadvertent closure of an EV considered as part of the atrial septum. The finding of a redundant EV can also add technical difficulties for the percutaneous treatment of ASD. The correct recognition and detailed description of this finding are important to avoid equivocal diagnosis and complications in patients referred for cardiac surgery. Thus, attention to this anatomicvariant, and careful TEE examination are fundamental for the correct diagnosis and therapeutic approach.


Subject(s)
Humans , Echocardiography, Transesophageal/methods , Echocardiography, Transesophageal , Heart Atria , Vena Cava, Inferior/abnormalities , Vena Cava, Inferior/embryology
17.
Rev. bras. cir. cardiovasc ; 24(4): 578-580, out.-dez. 2009. ilus
Article in English | LILACS | ID: lil-540765

ABSTRACT

Intra-cavitary thrombus size, mobility and friability are of great importance in deciding whether surgical removal is indicated. Thrombus characteristics may render surgical thrombectomy incomplete, a risk for catastrophic embolization. During de-airing of the heart, after removal of an intraventricular thrombus, filling the open ventricular cavity with blood serendipitously allowed trans-esophageal echocardiographic (TEE) visualization of undetected residual thrombi fragments. This experience leads us to advocate repeated filling and emptying of the left ventricle with blood, under TEE guidance, in order to facilitate complete removal of thrombotic material prior to ventriculotomy closure, and prior to weaning from cardiopulmonary bypass (CPB).


O tamanho, mobilidade e friabilidade do trombo intracavitário são de importância significativa na decisão para a realização da remoção cirúrgica. Precisamente, essas características do trombo podem resultar em uma trombectomia cirúrgica incompleta, com o risco de embolização catastrófica. Durante a manobra de deaeração após a remoção de um trombo intraventricular, o enchimento da cavidade ventricular com sangue permite a visualização de fragmentos residuais possivelmente indetectáveis. É proposto o enchimento e o esvaziamento repetitivo do coração com sangue guiado por ecocardiografia transesofágica intraoperatória para facilitar a remoção de material trombótico antes do fechamento da ventriculotomia e descontinuação circulação extracorpórea.


Subject(s)
Aged , Humans , Male , Echocardiography, Transesophageal/methods , Heart Ventricles , Monitoring, Intraoperative/methods , Thrombosis , Ultrasonography, Interventional/methods , Heart Ventricles/surgery , Thrombosis/surgery
18.
Arq. bras. cardiol ; 90(6): e45-e48, jun. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-485193

ABSTRACT

Trombos móveis no átrio direito são raros e associados a altas taxas de embolia pulmonar e de mortalidade. Neste relato é apresentado um caso de trombo em trânsito nas câmaras direitas, com suspeita clínica de tromboembolismo pulmonar, diagnosticado por ecocardiografia transesofágica, com boa evolução após anticoagulação. São também discutidas suas formas de apresentação, tratamento e evolução.


Emboli in transit in right atrium are rare. When they occur, they are associated to high rate of pulmonary embolism and mortality. This is a case report on an embolus in transit in right chambers, with clinical suspicion of pulmonary thromboembolism. Diagnosis was obtained through transesophageal echocardiography. The patient had a positive response post-anticoagulation. The team discussed presentation forms, treatment and condition development.


Subject(s)
Female , Humans , Middle Aged , Anticoagulants/therapeutic use , Heart Diseases , Pulmonary Embolism , Thrombosis , Echocardiography, Transesophageal , Heart Atria , Heart Diseases/complications , Pulmonary Embolism/drug therapy , Thrombosis/drug therapy , Venous Thrombosis/drug therapy , Venous Thrombosis
19.
Rev. Assoc. Med. Bras. (1992) ; 53(4): 349-354, jul.-ago. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-460307

ABSTRACT

OBJETIVO: A termodiluição (TD) é padrão de monitorização hemodinâmica. Alguns parâmetros hemodinâmicos podem ser medidos através do Doppler Transesofágico (DTE). Método simples, menos invasivo. Com o objetivo de avaliar a acurácia do DTE foram comparados TD e DTE na determinação de medidas de débito cardíaco (DC). MÉTODOS: Foram determinadas 192 medidas simultâneas, em diferentes situações clínicas em dez pacientes com idade entre 21 85 anos (cinco do gênero masculino e cinco do feminino), oito internados sépticos em uso de drogas vasoativas e dois monitorizados para laringectomia e transplante hepático; todas avaliadas ao longo de quatro horas, em intervalos de 30 minutos. Foram utilizados dois tipos de doppler: o DeltexR, e o ArrowR, introduzidos entre 35 e 45 cm da fossa nasal e localizados no ponto de maior diâmetro da aorta descendente. Na TD, foi utilizado cateter de artéria pulmonar (Swan Ganz BaxterR) e monitor DX-2001R, confirmado o posicionamento radiologicamente e através das curvas pressóricas geradas. As medidas do DC realizadas através da TD foram obtidas com soro fisiológico gelado, sendo considerada a média de quatro medidas não diferentes de 5 por cento. Foi aplicado o método estatístico de Bland e Altman, com utilização de gráfico de regressão linear. RESULTADOS: Não houve diferença estatisticamente significante entre esses dois métodos de medida hemodinâmica, com coeficiente de correlação de 0,88 para o DC (Doppler DeltexR X Swan Ganz BaxterR) e coeficiente de correlação de 0,99 DC (Doppler Arrow rR X Swan Ganz BaxterR) respectivamente, observando-se correlação. CONCLUSÃO: A medida das variáveis hemodinâmicas ao DTE foi obtida com facilidade nos dez pacientes estudados e revelou ter este dispositivo acurácia compatível à TD.


OBJECTIVES: Thermodilution (TD) is the "gold standard method" for hemodynamic monitoring. Some parameters can be measured by Oesophageal Doppler (OD), which is simpler and less invasive. To evaluate the accuracy of OD, we compared this method with TD in measurement of cardiac output (CO). METHODS: One hundred and ninety two simultaneous measurements were made in 10 patients (5 male and 5 female) with different clinical situations, 8 with sepsis using vasoactive drugs and 2 monitored for laryngectomy and liver transplantation. Measurements were taken during 4 hours at 30 minute intervals. The two oesophageal dopplers used DeltexR and ArrowR, were introduced between 35 and 45 cm from the nose and located at the point of largest diameter of the descending aorta. In TD, we used the pulmonary artery catheter (Swan Ganz BaxterR) and the DX- 2001 monitorR positioning was confirmed with support of radiology and of pressures curves. Measurements of CO carried out by means of TD were achieved using an iced saline solution considering the mean of four measurements with less than a 5 percent difference. The statistical method used was the Bland-Altman scatter plot and dispersion graphic. RESULTS: No statistically significant difference was found between the two methods for hemodyamic measurement with a correlation coefficient of 0.8 for CO (Deltex DopplerR and Baxter Swan GanzR) and a correlation coefficient of 0.99 for CO (Arrow DopplerR and Baxter Swan GanzR). CONCLUSION: Homodynamic measurements with OD have the same accuracy as those with TD and were easily obtained in the 10 patients.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cardiac Output/physiology , Echocardiography, Doppler/methods , Echocardiography, Transesophageal/methods , Hemodynamics/physiology , Thermodilution/methods , Epidemiologic Methods , Echocardiography, Doppler/instrumentation , Echocardiography, Transesophageal/instrumentation , Laryngectomy , Liver Transplantation , Vasoconstrictor Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL