Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Journal of Shanghai Jiaotong University(Medical Science) ; (12): 653-657, 2018.
Article in Chinese | WPRIM | ID: wpr-843685

ABSTRACT

Objective • To find out the optimal positive end expiratory pressure (PEEP) by electrical impedance tomography (EIT) for better lung recruitment and ventilation distribution in patients undergoing off pump coronary artery bypass grafting surgery (OPCAB). Methods • 105 patients underwent OPCAB from Jan. 2017 to Dec. 2017 were analysed. Patients were randomly divided into two groups, i.e. experiment group (54 cases) and control group (51 cases). Four regions of interest (ROI) were recorded by EIT. PEEP were 3 cmH2O in control group while PEEP were increased stepwise by 2 cmH2O from 0 cmH2O to 14 cmH2O in experiment group. The optimal PEEP for lung recruitment was applied in experiment group. Postoperative oxygenation index (PaO2/FiO2) and pulmonary complication were compared between two groups. Results • The overall mortality was 2 (1.90%). The incidence of postoperative pulmonary complication, pulmonary infection, atelectasis, pleural effusion were 18.10%, 2.86%, 18.10%, 18.10%, respectively. The optimal PEEP zone was 6-9 cmH2O. PaO2/FiO2 was significantly increased with the optimal PEEP in experiment group (P=0.00). There were significant differences in postoperative pulmonary complication between two groups (P=0.02). Conclusion • EIT can directly monitor ventilation distribution and titrate suitable PEEP for better lung recruitment in patients undergoing OPCAB. It can significantly reduce postoperative pulmonary complication, improve oxygenation, and decrease ICU stay and ventilation duration.

2.
Journal of Shanghai Jiaotong University(Medical Science) ; (12): 653-657, 2018.
Article in Chinese | WPRIM | ID: wpr-695728

ABSTRACT

Objective·To find out the optimal positive end expiratory pressure (PEEP) by electrical impedance tomography (EIT) for better lung recruitment and ventilation distribution in patients undergoing off pump coronary artery bypass grafting surgery (OPCAB). Methods?·?105 patients underwent OPCAB from Jan. 2017 to Dec. 2017 were analysed. Patients were randomly divided into two groups, i.e. experiment group (54 cases) and control group (51 cases). Four regions of interest (ROI) were recorded by EIT. PEEP were 3?cmH2O in control group while PEEP were increased stepwise by 2?cmH2O from 0?cmH2O to 14?cmH2O in experiment group. The optimal PEEP for lung recruitment was applied in experiment group. Postoperative oxygenation index (PaO2/FiO2) and pulmonary complication were compared between two groups. Results?·?The overall mortality was 2 (1.90%). The incidence of postoperative pulmonary complication, pulmonary infection, atelectasis, pleural effusion were 18.10%, 2.86%, 18.10%, 18.10%, respectively. The optimal PEEP zone was 6-9?cmH2O. PaO2/FiO2was significantly increased with the optimal PEEP in experiment group (P=0.00). There were significant differences in postoperative pulmonary complication between two groups (P=0.02). Conclusion?·?EIT can directly monitor ventilation distribution and titrate suitable PEEP for better lung recruitment in patients undergoing OPCAB. It can significantly reduce postoperative pulmonary complication, improve oxygenation, and decrease ICU stay and ventilation duration.

3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-592559

ABSTRACT

Objective To compare the performance of novel Ag/AgCl pulverized electrodes with conventional Ag/AgCl coating electrodes in cerebral application of Electrical Impedance Tomography(EIT).Methods Based on the EIT system developed by our group,raw data were measured on a phantom and an adult volunteer,with Ag/AgCl coating electrodes and pulverized electrodes,respectively.The performances of electrode systems were evaluated in contact impedance and two other figures(the high-frequency SNR,HFSNR;the low-frequency SNR,LFSNR).Results Ag/AgCl pulverized electrode plays a better performance in resisting noise and keeping stabilization.Conclusion Ag/AgCl pulverized electrode develops the needs of imaging and monitoring human brains in EIT more availably.

4.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-588163

ABSTRACT

The reverse problem of Electrical impedance tomography(EIT) is a highly ill-posed problem.It is concluded that spatial prior information could improve the final image quality.This paper proposes a new method for obtaining prior information.By this method,the inspected cross-section contour and internal structure for EIT can be achieved.

5.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-586316

ABSTRACT

It is very important for pulmonary disease treatment to monitor the pulmonary function continuously. In this paper, the hardware of electrical impedance tomography (EIT) system is designed, and simulative model of human thorax is established for image reconstruction based on Landweber pre-iteration method. Compared with linear back projection, the method above results in the better image reconstruction with little trailing and increased speed of real-time reconstruction.

SELECTION OF CITATIONS
SEARCH DETAIL