Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Korean Journal of Urology ; : 1027-1034, 2007.
Article in Korean | WPRIM | ID: wpr-32272

ABSTRACT

PURPOSE: We compared the efficacy of two shock wave energy sources; the newer electromagnetic lithotriptor(EML, Dornier Compact Delta(R)) and electroconductive lithotriptor(ECL, EDAP-Sonolith Praktis) that were used for treatment of the urinary calculi. MATERIALS AND METHODS: From January 2004 to October 2006, 614 patients were treated with EML. From January 2000 to October 2006, 936 patients were treated with ECL. Following lithotripsy, a plain abdominal film was taken 1 week after each session to determine if there were residual stones and assessed the need for retreatment. Success was defined as no residual stones. We analyzed the site and size of stones, success rate, mean session, mean treatment time, causes of failure and complications. RESULTS: The success rate was 95.9% for EML compared to 93.6% for ECL (p=0.048). The success rate was decreased for 20mm or larger stones. The treatment mean session wasn't different but the total treatment time was significantly longed for EML(58.5+/-27.1 min) compared for ECL(39.7+/-21.7 min)(p<0.05). No statistically significant difference were found in complications and failure between both groups. Insufficient fragment was most common cause of failure in both groups(1.8% for EML versus 2.4% for ECL). Gross hematuria were noted 26.4% of patient treated with EML and 26.6% of those treated with ECL. CONCLUSIONS: The EML has a little advantages over the ECL in terms of total success rate, but ECL has its advantage in mean and total treatment time. Ultimately, these two contemporary energy sources are acceptable. They are equally efficacious, judging from single center treatment and follow-up criteria.


Subject(s)
Humans , Electromagnetic Phenomena , Follow-Up Studies , Hematuria , Lithotripsy , Magnets , Retreatment , Shock , Urinary Calculi
2.
Journal of the Japan Society of Acupuncture and Moxibustion ; : 215-220, 1983.
Article in Japanese | WPRIM | ID: wpr-377854

ABSTRACT

We made the electrophotography which is able to visualize the distribution of electroconductivity to the skin.<br>According to an electric quantity, reducing KI into iodine, we got a compound of AgI with galvanochemical response and took a picture of a galvanic skindistribution on it. We may be able to apply both the A. C. and the D. C. in power supply. In order to take a good picture of electroconductive points, we used 12V of the D. C.. In this case, an electric quantity was<br>3.6×10<sup>-4</sup>-4.8×10<sup>-3</sup>W.Min./cm<sup>2</sup>

SELECTION OF CITATIONS
SEARCH DETAIL