Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
BrJP ; 6(3): 237-243, July-sept. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520292

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: Conventional electrodiagnostic studies (EDX) are frequently used to support the diagnosis of peripheral neuropathic pain. However, routine EDX has poor diagnostic yield for identifying small fiber neuropathy, which may be cause of neuropathic pain in some patients. This study aimed to assess the gain in diagnostic yield brought by adding pain-related evoked potentials with concentric electrode (CN-PREP) and nociceptive withdrawal reflex (NWR) assessments to EDX. METHODS: Transversal observational accuracy study which included patients referred to routine EDX in a tertiary-care hospital who reported chronic neuropathic pain in their lower limbs. Besides routine EDX, subjects underwent CN-PREP and NWR assessments. Diagnostic yield and tolerability were examined and compared between test studies. RESULTS: The study enrolled 100 patients (54% female), with 57 ± 12 years. EDX was altered in 47% of all patients. The addition of CN-PREP alone, and NWR combined with CN-PREP increased diagnostic yield to 69% and 72%, respectively. CN-PREP proved to be well tolerable, while NWR was associated with higher test-related pain intensity and discontinuation rate (9% vs. 0%). Considering EDX as the reference test, CN-PREP sensitivity was 85.1% and specificity 58.5%. CONCLUSION: Combining CN-PREP with the routine EDX for patients with neuropathic pain is feasible and results in increased diagnostic yield. Conversely, the addition of NWR to the aforementioned tests provides little improvement to this yield and is less tolerable to the patient. Further studies are needed to determine the actual sensitivity and specificity of CN-PREP when compared to the gold-standard for small fiber neuropathy diagnosis, i.e. intraepidermal nerve fiber density assessment.


RESUMO JUSTIFICATIVA E OBJETIVOS: Estudos convencionais de eletrodiagnóstico (EDX) são frequentemente usados para apoiar o diagnóstico de dor neuropática periférica. No entanto, o EDX de rotina tem baixo rendimento diagnóstico para identificar neuropatia de pequenas fibras. O objetivo deste estudo foi avaliar o ganho no rendimento diagnóstico pela adição de avaliações de potenciais evocados relacionados à dor com eletrodo concêntrico (CN-PREP) e reflexo de retirada nociceptiva (NWR) ao EDX. MÉTODOS: Estudo de precisão observacional transversal que incluiu pacientes encaminhados para EDX de rotina com dor neuropática crônica em membros inferiores. Além do EDX de rotina, os indivíduos foram submetidos às avaliações CN-PREP e NWR. O rendimento diagnóstico e a tolerabilidade foram examinados e comparados entre os estudos de teste. RESULTADOS: O estudo envolveu 100 pacientes (54% mulheres), com 57 ± 12 anos. O EDX estava alterado em 47%. A adição de CN-PREP sozinho e NWR combinado com CN-PREP aumentou o rendimento diagnóstico para 69% e 72%, respectivamente. O CN-PREP provou ser bem tolerável, enquanto o NWR foi associado a maior intensidade de dor relacionada ao teste e taxa de descontinuação (9% vs. 0%). Considerando o EDX como teste de referência, a sensibilidade do CN-PREP foi de 85,1% e a especificidade de 58,5%. CONCLUSÃO: A combinação do CN-PREP com o EDX de rotina para pacientes com dor neuropática é viável e resulta em maior rendimento diagnóstico. Já a adição de NWR aos testes mencionados fornece pouca melhora nesse rendimento e é menos tolerável para o paciente. Mais estudos são necessários para determinar a real sensibilidade e especificidade do CN-PREP quando comparado ao padrão-ouro para diagnóstico de neuropatia de pequenas fibras, ou seja, a avaliação da densidade de fibras nervosas intraepidérmicas.

2.
Arq. bras. cardiol ; 116(5): 908-916, nov. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1248912

ABSTRACT

Resumo Fundamento: Nas últimas décadas, o número de dispositivos eletrônicos cardíacos implantáveis (DCEI) aumentou consideravelmente, assim como a necessidade de remoção destes. Neste contexto, a remoção percutânea apresenta-se como uma técnica segura e capaz de evitar uma cirurgia cardíaca convencional. Objetivos: Primário: descrever a taxa de sucesso e complicações da remoção percutânea de DCEI em um hospital público brasileiro. Secundário: estabelecer preditores de sucesso e complicações. Métodos: Serie de casos retrospectiva de todos os pacientes submetidos à remoção de DCEI em um hospital público brasileiro no período de janeiro de 2013 a junho de 2018. Remoção, explante e extração de eletrodos, complicações e desfechos foram definidos conforme a diretriz norte-americana de 2017. Variáveis categóricas foram comparadas pelos testes Qui-quadrado ou Fisher, enquanto variáveis contínuas, por testes não pareados. O nível de significância adotado nas análises estatísticas foi de 5%. Resultados: 61 pacientes foram submetidos à remoção de DCEI, sendo 51 extrações e 10 explantes. No total, 128 eletrodos foram removidos. Taxa de sucesso clínico foi 100% no grupo do explante e 90,2% no da extração (p=0,58). Complicações maiores foram encontradas em 6,6% dos pacientes. Falha do procedimento foi associada a eletrodos de ventrículo (p=0,05) e átrio (p=0,04) direito implantados há mais tempo. Duração do procedimento (p=0,003) e necessidade de transfusão sanguínea (p<0,001) foram associadas a maior índice de complicação. Conclusão: As taxas de complicação e sucesso clínico observadas foram de 11,5% e 91,8%, respectivamente. Remoções de eletrodos atriais e ventriculares mais antigos estiveram associados a menores taxa de sucesso. Procedimentos mais longos e necessidade de transfusão sanguínea foram associados a complicações.


Abstract Background: In the last decade, the number of cardiac electronic devices has risen considerably and consequently the occasional need for their removal. Concurrently, the transvenous lead removal became a safe procedure that could prevent open-heart surgery. Objective: The primary objective of this study was to describe the successful performance and the complication rates of pacemaker removals in a Brazilian public hospital. Our secondary aim was to describe the variables associated to successes and complications. Methods: A retrospective case series was conducted in patients submitted to pacemaker removal in a Brazilian public hospital from January 2013 to June 2018. Removal, explant, extraction, success and complication rates were defined by the 2017 Heart Rhythm Society Guideline. Categorical variables were compared using x2 or Fisher's tests, while continuous variables were compared by unpaired tests. A p-value of 0.05 was considered statistically significant. Results: Cardiac device removals were performed in 61 patients, of which 51 were submitted to lead extractions and 10 to lead explants. In total, 128 leads were removed. Our clinical success rate was 100% in the explant group and 90.2% in the extraction one (p=0.58). Major complications were observed in 6.6% patients. Procedure failure was associated to older right ventricle (p=0.05) and atrial leads (p=0,04). Procedure duration (p=0.003) and need for blood transfusion (p<0,001) were associated to more complications. Conclusion: Complications and clinical success were observed in 11.5% and 91.8% of the population, respectively. Removal of older atrial and ventricular leads were associated with lower success rates. Longer procedures and blood transfusions were associated with complications.


Subject(s)
Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable , Brazil , Retrospective Studies , Treatment Outcome , Device Removal
3.
Arq. bras. cardiol ; 115(6): 1114-1124, dez. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152928

ABSTRACT

Resumo Fundamento Remoção de cabos-eletrodos de dispositivos cardíacos eletrônicos implantáveis (DCEI) é procedimento pouco frequente e sua realização exige longo treinamento profissional e infraestrutura adequada. Objetivos Avaliar a efetividade e a segurança da remoção de cabos-eletrodos de DCEI e determinar fatores de risco para complicações cirúrgicas e mortalidade em 30 dias. Métodos Estudo prospectivo com dados derivados da prática clínica. De janeiro/2014 a abril/2020, foram incluídos, consecutivamente, 365 pacientes submetidos à remoção de cabos-eletrodos, independentemente da indicação e técnica cirúrgica utilizada. Os desfechos primários foram: taxa de sucesso do procedimento, taxa combinada de complicações maiores e morte intraoperatória. Os desfechos secundários foram: fatores de risco para complicações intraoperatórias maiores e morte em 30 dias. Empregou-se análise univariada e multivariada, com nível de significância de 5%. Resultados A taxa de sucesso do procedimento foi de 96,7%, sendo 90,1% de sucesso completo e 6,6% de sucesso clínico. Complicações maiores intraoperatórias ocorreram em 15 (4,1%) pacientes. Fatores preditores de complicações maiores foram: tempo de implante dos cabos-eletrodos ≥ 7 anos (OR= 3,78, p= 0,046) e mudança de estratégia cirúrgica (OR= 5,30, p= 0,023). Classe funcional III-IV (OR= 6,98, p<0,001), insuficiência renal (OR= 5,75, p=0,001), infecção no DCEI (OR= 13,30, p<0,001), número de procedimentos realizados (OR= 77,32, p<0,001) e complicações maiores intraoperatórias (OR= 38,84, p<0,001) foram fatores preditores para mortalidade em 30 dias. Conclusões Os resultados desse estudo, que é o maior registro prospectivo de remoção de cabos-eletrodos da América Latina, confirmam a segurança e a efetividade desse procedimento no cenário da prática clínica real. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Abstract Background Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time ≥ 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Subject(s)
Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Prospective Studies , Retrospective Studies , Treatment Outcome , Device Removal
4.
Rev. colomb. ciencias quim. farm ; 49(3): 710-719, Sep.-Dec. 2020. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1156312

ABSTRACT

RESUMO Um processo eletroanalítico da detecção quantitativa dos íons de zinco bivalente sobre as novas bases de Schiff no modo galvanostático tem sido simulado teoricamente. O respectivo modelo matemático tem sido desenvolvido e analisado mediante a teoria de estabilidade linear e da análise de bifurcações. Foi estabelecido que o sistema é eficiente tanto do ponto de vista eletroanalítico, como do ponto de vista eletrossintético, por ser facilmente estabilizado o estado estacionário. Todavia, o comportamento oscilatorio, neste sistema é mais provável que no caso clássico do desempenho de sensores, baseados em polímeros condutores e outros materiais orgânicos, por haver influências na dupla camada elétrica, causadas pela reação química da formação de complexo.


SUMMARY An electroanalytical process of the quantitative determination of bivalent zinc ions over the novel Schiff bases in galvanostatic mode has been theoretically simulated. The correspondent mathematical model has been developed and analyzed by means of linear stability theory and bifurcation analysis. It was shown that the system is efficient from both electroanalytical and electrosynthetical points of view, as the steady-state is easily stabilized. Nevertheless, the oscillatory behavior in this system is more probable than in the classic case of the sensors, based on conducting polymers and other organic materials, as there are double electric layer influences, caused by complex formation.

5.
Rev. colomb. ciencias quim. farm ; 48(3): 662-676, sep.-dic. 2019. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1138775

ABSTRACT

RESUMO O processo da determinação eletroanalítica do fármaco letrozol, assistida pelo compósito VO(OH)-polipirrol, obtido mediante um processo catódico, foi descrito teoricamente. Tanto para a síntese do compósito, como para o processo eletroana-lítico foi sugerido e analisado, mediante a teoria de estabilidade linear e análise de bifurcações, um modelo matemático. Foi mostrado que, ao contrário da eletrossín-tese de polipirrol catódica, iniciada por um composto na solução, o polipirrol resultante tem uma morfologia mais "centrada" aos centros ativos da matriz, dopados pelos cátions VO2+. No entretanto, tanto a síntese do compósito, como o seu desempenho eletroanalítico com o letrozol podem ser considerados eficientes.


SUMMARY The process of the electroanalytical determination of letrozol drug, assisted by the cathodically obtained VO(OH)-Polypyrrole, has been theoretically described. For both the composite synthesis and electroanalytical function a mathematical model has been suggested and analyzed by means of linear stability theory and bifurcation analysis. It was shown that, contrarily to the cathodic polypyrrole electrosynthesis, initiated by a compound in a solution, the resulting cathodic polypyrrole has more "centred" morphology, in the relation to the matrix active centers, doped by VO2+ cations. Nevertheless, either the synthesis of the composite, or its electroanalytical function with letrozole may be considered efficient.

6.
Rev. colomb. ciencias quim. farm ; 48(2): 455-466, mayo-ago. 2019. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1092956

ABSTRACT

RESUMO Por meio de uma análise teórica, foi avaliado o desempenho do compósito do oxihidróxido do vanádio trivalente com o polímero do corante alaranjado da acridina, na detecção eletroquímica do fármaco antiparquinsônico entacapona. O processo eletroanalítico é baseado na eletrorredução do fármaco mencionado. Do desenvolvimento e da análise do modelo matemático correspondente, mediante a teoria de estabilidade linear e anáise de bifurcações, foi possível concluir que o compósito pode ser um modificador eficiente para a determinação da entacapona. Os comportamentos oscilatórios e monotônico, neste sistema, também são passíveis de realizar.


SUMMARY By means of a theoretical analysis, the function of trivalent vanadium oxyhydroxyde composite with the polymer of the acridine orange dye for electrochemical evaluation of entacapone antiparkinsonic drug has been evaluated. The electroanalytical process is based on the electrochemical reduction of the mentioned drug. From development and analysis of the correspondent mathematical model by means of linear stability theory and bifurcation analysis, it was possible to conclude that the composite is an efficient electrode modifier for entacapone determination. The oscillatory and monotonic instabilities in this system are also capable to realize.

7.
Rev. colomb. ciencias quim. farm ; 47(3): 400-409, set.-dez. 2018. graf
Article in Portuguese | LILACS | ID: biblio-990925

ABSTRACT

RESUMO Pela primeira vez foi descrito um caso interessante de uso do oxihidróxido de vanádio trivalente (VO(OH)) como modificador de elétrodo na detecção eletroquímica de nandrolona. Foi mostrado que o oxihidróxido de vanádio pode ser um modificador eficiente para a detecção de nandrolona, mas, ao contrário da maioria dos casos de uso de oxihidróxido de cobalto, composto parecido, o processo é catódico e dá-se em meio moderadamente ácido a neutro. O comportamento oscilatório, no sistema, é possível apenas por causa das influências do processo da eletrorredução de vanádio tetravalente em trivalente na dupla camada elétrica.


SUMMARY An interesting case of the use of trivalent vanadium oxyhydroxide (VO(OH)) as an electrode modifier for nandrolone electrochemical determination has been described for the first time. It was shown that vanadium (III) oxyhydroxide may be an efficient electrode modifier for nandrolone determination, but, contrarily to the majority of the cases of the use of cobalt (III) oxyhydroxide, which is a relative compound, the process is cathodic and it is realized in moderately acid solutions, tending to neutral. The oscillatory behavior in the system is possible, due to the influence of the electrochemical reduction of tetravalent vanadium to trivalent in double electric layer.

8.
Rev. colomb. ciencias quim. farm ; 47(3): 441-451, set.-dez. 2018. graf
Article in Portuguese | LILACS | ID: biblio-990928

ABSTRACT

RESUMO A possibilidade do uso de um novo derivado de acridina, munido de um grupo doador de elétrons, como modificador de elétrons para a detecção do conteúdo total do ácido gálico em goma de alfarroba tem sido avaliada mediante uma análise teórica. O modelo matemático correspondente foi analisado mediante a teoria de estabilidade linear e análise de bifurcações. Foi mostrado que o derivado fosfazoico da acridina pode servir de modificador eficiente para a detecção eletroanalítica do conteúdo total do ácido gálico em alfarroba. As causas dos comportamentos oscilatório e monotônico também foram detectadas.


SUMMARY The possibility of the use of the novel acridinic derivative, containing an electron donor moiety in the total gallic acid content determination in carob gum has been evaluated by means of a theoretical analysis. The correspondent mathematical model has been analyzed by linear stability theory and bifurcation analysis. It was shown that the phosphazoic acridine derivative may serve as an efficient electrode modifier for electroanalytical determination of the total content of gallic acid in carob. The causes for the oscillatory and monotonic behavior have also been stipulated.

9.
Arq. bras. cardiol ; 111(5): 686-696, Nov. 2018. tab, graf
Article in English | LILACS | ID: biblio-973794

ABSTRACT

Abstract Background: Venous obstructions are common in patients with transvenous cardiac implantable electronic devices, but they rarely cause immediate clinical problems. The main consequence of these lesions is the difficulty in obtaining venous access for additional leads implantation. Objectives: We aimed to assess the prevalence and predictor factors of venous lesions in patients referred to lead reoperations, and to define the role of preoperative venography in the planning of these procedures. Methods: From April 2013 to July 2016, contrast venography was performed in 100 patients referred to device upgrade, revision and lead extraction. Venous lesions were classified as non-significant (< 50%), moderate stenosis (51-70%), severe stenosis (71-99%) or occlusion (100%). Collateral circulation was classified as absent, discrete, moderate or accentuated. The surgical strategy was defined according to the result of the preoperative venography. Univariate analysis was used to investigate predictor factors related to the occurrence of these lesions, with 5% of significance level. Results: Moderate venous stenosis was observed in 23%, severe in 13% and occlusions in 11%. There were no significant differences in relation to the device side or the venous segment. The usefulness of the preoperative venography to define the operative tactic was proven, and in 99% of the cases, the established surgical strategy could be performed according to plan. Conclusions: The prevalence of venous obstruction is high in CIED recipients referred to reoperations. Venography is highly indicated as a preoperative examination for allowing the adequate surgical planning of procedures involving previous transvenous leads.


Resumo Fundamento: Obstruções venosas são frequentes em portadores de dispositivos cardíacos eletrônicos implantáveis (DCEI) endocárdicos, mas raramente causam problemas clínicos imediatos. A principal consequência destas lesões é a dificuldade para obtenção de via de acesso para o implante de novos cabos-eletrodos. Objetivos: Determinar a prevalência de lesões venosas em candidatos a reoperações envolvendo o manuseio de cabos-eletrodos, e definir o papel da venografia pré-operatória no planejamento desses procedimentos. Métodos: De abril de 2013 a julho de 2016, 100 pacientes com indicação de troca de cabos-eletrodos, ou mudança no modo de estimulação, realizaram venografia com subtração digital no período pré-operatório. As lesões venosas foram classificadas em: não significativas (< 50%), moderadas (51-70%), graves (71-99%) ou oclusivas (100%), e a circulação colateral, em ausente, discreta, moderada ou acentuada. A estratégia cirúrgica foi definida a partir do resultado deste exame. Empregou-se análise univariada para a pesquisa de fatores de risco relacionados à ocorrência dessas lesões, com nível de significância de 5%. Resultados: Obstruções venosas moderadas foram observadas em 23%, graves em 13% e oclusões em 11% dos pacientes estudados, não sendo identificadas diferenças significativas em sua distribuição em relação ao lado do implante, ou do segmento venoso. A utilidade do exame para definição da tática operatória foi comprovada, sendo que em 99% dos casos, a estratégia cirúrgica estabelecida pode ser executada. Conclusões: A prevalência de obstruções venosas é elevada em portadores de DCEI que serão submetidos a reoperações. A venografia é altamente indicada como exame pré-operatório para o adequado planejamento cirúrgico de procedimentos envolvendo cabos-eletrodos transvenosos previamente implantados.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Reoperation/methods , Vascular Diseases/diagnostic imaging , Preoperative Care/methods , Phlebography/methods , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Postoperative Complications/prevention & control , Reoperation/standards , Vascular Diseases/epidemiology , Prevalence , Cross-Sectional Studies , Constriction, Pathologic/diagnostic imaging , Cardiac Resynchronization Therapy/adverse effects
11.
Arq. bras. cardiol ; 111(4): 607-615, Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-973766

ABSTRACT

Abstract Background: Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response. Objectives: To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT. Methods: This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%. Results: We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002). Conclusion: CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.


Resumo Fundamento: A insuficiência cardíaca (IC) afeta mais de 5 milhões de pessoas nos Estados Unidos, com mais de 1 milhão de internações/ano. A terapia de ressincronização (TRC) pode beneficiar pacientes com IC avançada e QRS alargado; entretanto, percentual significativo de pacientes não respondem à TRC. O dissincronismo elétrico isolado pode não representar um bom preditor de resposta, e o local da última ativação do ventrículo esquerdo (VE) pode influenciar na resposta. Objetivos: Avaliar o dissincronismo eletromecânico na TRC com o implante do eletrodo do VE orientado por GATED SPECT. Métodos: Incluídos 15 pacientes com IC classe funcional II-IV, otimizados clinicamente, com fração de ejeção de 35%, ritmo sinusal, bloqueio de ramo esquerdo, QRS ≥ 120 ms. Realizaram eletrocardiograma, Questionário Minnesota Vivendo com Insuficiência Cardíaca (MLHFQ) e cintilografia GATED SPECT até 4 semanas antes do implante. Reavaliados 6 meses após. Análise primária visou determinar a proporção de pacientes com redução da duração do QRS e resposta favorável à TRC dependendo da concordância ou não na posição do eletrodo, utilizando teste Qui-Quadrado. Análise das variáveis pré e pós TRC foi feita através do teste t de Student, assumindo significância de 5%. Resultados: Realizamos 15 implantes com 2 óbitos no seguimento. As reduções das durações do QRS (212 ms vs 136 ms) e do IPR (179 ms vs 126 ms) foram significativas (p < 0,001). Em 54%, o eletrodo foi concordante com o local de maior atraso. No grupo respondedor, a posição lateral foi prevalente. O MLHFQ mostrou melhora significativa da qualidade de vida (p < 0,0002). Conclusão: A TRC determina melhora da qualidade de vida e do sincronismo elétrico. O sincronismo eletromecânico relaciona-se com a resposta à TRC. O posicionamento do eletrodo de VE no sítio de maior retardo tem limitações.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Ventricular Dysfunction, Left/therapy , Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography/methods , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices , Heart Failure/therapy , Quality of Life , Stroke Volume , Time Factors , Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Fluoroscopy , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/diagnostic imaging , Statistics, Nonparametric , Electrocardiography , Heart Failure/physiopathology , Heart Failure/diagnostic imaging
13.
Rev. colomb. ciencias quim. farm ; 47(1): 71-85, ene.-abr. 2018. graf
Article in Portuguese | LILACS | ID: biblio-959998

ABSTRACT

RESUMO O comportamento eletroquímico da lidocaína durante a sua eletrooxidação sobre o oxihidróxido de cobalto trivalente em meio levemente básico, realizada para fins eletroanalíticos, foi avaliado do ponto de vista mecanístico matemático. Da análise foi feita uma conclusão acerca do desempenho do CoO(OH) como modificador de elétrodo na eletrooxidação da lidocaína in vivo e in vitro. Foi, outrossim, verificada a possibilidade da realização das instabilidades oscilatória e monotônica no sistema.


Summary The electrochemical behavior of lidocaine during its electrooxidation over trivalent cobalt oxyhydroxide in lightly alkaline medium, realized for electroanalytical purposes, was evaluated from the mechanistic mathematical point of view. From analysis a conclusion has been made of the electroanalytical function of CoO(OH) as an electrode modifier for lidocaine electrooxidation in vivo and in vitro. Also, the possibility of oscillatory and monotonic instabilities has been verified in the system.

14.
Rev. colomb. ciencias quim. farm ; 46(3): 331-341, sep.-dic. 2017.
Article in Portuguese | LILACS | ID: biblio-900650

ABSTRACT

RESUMO Um caso interessante da eletrooxidação de dopamina, acompanhada por sua eletropolimerização, em que tanto o monômero, como o polímero condutor resultante podem ser oxidados até à respectiva forma quinônica, foi investigado do ponto de vista teórico. A análise do modelo matemático, correspondente a este sistema, mostrou que o estado estacionário, neste sistema é fácil de manter estável, apesar de a zona topológica, correspondente a esta estabilidade, ser mais estreita. Já as instabilidades oscilatória e monotônica mostraram-se mais prováveis neste caso que em sistemas semelhantes.


SUMMARY An interesting case for dopamine electrooxidation, in which either a monomer, or a polymer may be oxidized to the correspondent quinonic form, has been investigated from the theoretical point of view. The analysis o the correspondent mathematical model has shown that in this system the steady-state is easy to maintain stable, despite of the more narrow extension of the topological zone, correspondent to this stability. Yet the oscillatory and monotonic instabilities may be more probable in this cast, than in the similar ones.

15.
Iatreia ; 30(3): 255-264, jul.-set. 2017. tab, graf
Article in Spanish | LILACS | ID: biblio-892661

ABSTRACT

RESUMEN Antecedentes: existe controversia sobre la exactitud de las técnicas de bioimpedancia para calcular el porcentaje de grasa corporal (%GC). Objetivo: comparar el %GC obtenido por tres técnicas de bioimpedancia con la hidrodensitometría como método de referencia. Metodología: en 31 mujeres se midió el %GC por hidrodensitometría con medición simultánea del volumen residual pulmonar, y por las técnicas de bioimpedancia manos-pies (8-electrodos), mano-pie (4-electrodos) y pie-pie (4-electrodos). Resultados: el promedio de edad fue 22,4 ± 2,8 años y el del índice de masa corporal 23,6 ± 3,3 kg/m2 . No hubo diferencias (p > 0,05) en el %GC obtenido por hidrodensitometría y por la técnica manos-pies (31,4 ± 6,6 % y 31,9 ± 5,9 %, respectivamente). Las técnicas mano-pie y pie-pie presentaron diferencias (p < 0,05) en el %GC con la hidrodensitometría de +1,4 % y -4,9 %, respectivamente. El grado de acuerdo con el método de referencia fue aceptable para las técnicas manos-pies (Bland-Altman: IC95 %: -6,6; 5,6) y mano-pie (Bland-Altman: IC95 %: -8,0; 5,2), pero inadecuado para la técnica pie-pie (Bland-Altman: IC95 %: -4,7; 14,4). Conclusiones: en mujeres jóvenes con peso corporal promedio adecuado, la técnica de bioimpedancia manos-pies determina valores del %GC más cercanos a los de la hidrodensitometría que las técnicas mano-pie y pie-pie. Asimismo, la técnica manos-pies presenta una concordancia ligeramente mayor con el método de referencia que las técnicas mano-pie y pie-pie.


SUMMARY Background: Bioimpedance measurement allows quick and safe estimation of the body composition. However, it remains controversial which bioimpedance measurement technique is more exact for calculating the fat mass percentage (%FM). Objective: To compare the %FM obtained with three bioimpedance techniques with hydrodensitometry, as a reference method. Materials and methods: In 31 women, the %FM was assessed by hydrodensitometry with simultaneous lung residual volume measurement and three bioimpedance techniques: hands-to-feet (8-electrodes), hand-to-foot (4-electrodes) and footto-foot (4-electrodes). Results: Average age and body mass index were 22.4 ± 2.8 years and 23.6 ± 3.3 kg/m2 , respectively. There were no significant differences (p > 0.05) between the %FM obtained by hydrodensitometry (31.4 ± 6.6) and hands-to-feet technique (31.9 ± 5.9). However, hand-to-foot and foot-to-foot techniques showed differences (p < 0.05) with the reference method of +1.4 % and -4.9%, respectively. There was a fair agreement between hydrodensitometry and the results obtained with hands-to-feet (Bland-Altman: IC95 %: -6.6; 5.6) and hand-to-foot (Bland-Altman: IC95 %: -8.0; 5.2) techniques. The foot-to-foot measurement showed poor agreement with the reference method (Bland-Altman: IC95 %: -4.7; 14.4). Conclusions: In this group of young women with healthy body weight, the hands-to-feet bioimpedance technique generates body composition values closer to the hydrodensitometry results as compared with the hand-to-foot and foot-to-foot techniques. Additionally, the hands-to-feet technique shows a slightly better agreement with hydrodensitometry than the hand-to-foot and foot-to-foot techniques.


RESUMO Antecedentes: existe controvérsia sobre a exatidão das técnicas de bioimpedância para calcular a porcentagem de gordura corporal (%GC). Objetivo: comparar a %GC obtida por três técnicas de bioimpedância com a hidrodensitometria ou pesagem hidrostática como método de referência. Metodologia: em 31 mulheres se mediu a %GC por hidrodensitometria com medição simultânea do volume residual pulmonar, e pelas técnicas de bioimpedância mãos-pés (8-eletrodos), mão-pé (4-eletrodos) e pé-pé (4-eletrodos). Resultados: A média de idade foi 22,4 ± 2,8 anos e o do índice de massa corporal. 23,6 ± 3,3 kg/m2 . Não houve diferenças (p > 0,05) na %GC obtido por hidrodensitometria e pela técnica mãos-pés (31,4 ± 6,6 % e 31,9 ± 5,9 %, respectivamente). As técnicas mão-pé e pé-pé apresentaram diferenças (p < 0,05) na %GC com a hidrodensitometria de +1,4 % e -4,9 %, respectivamente. O grau de acordo com o método de referência foi aceitável para as técnicas mãos-pés (Bland-Altman: IC95 %: -6,6; 5,6) e mão-pé (BlandAltman: IC95 %: -8,0; 5,2), mas inadequado para a técnica pé-pé (Bland-Altman: IC95 %: -4,7;14,4). Conclusões: em mulheres jovens com peso corporal médio adequado, a técnica de bioimpedância mãospés determina valores da %GC mais próximos aos da hidrodensitometria que as técnicas mão-pé e pé- pé. Além disso, a técnica mãos-pés apresenta uma concordância ligeiramente maior com o método de referência que as técnicas mão-pé e pé-pé.


Subject(s)
Humans , Female , Adult , Body Composition , Body Fat Distribution , Densitometry
16.
Eng. sanit. ambient ; 22(1): 179-186, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-840387

ABSTRACT

RESUMO No Brasil, cerca de 32.700 postos de lavagem de veículos consomem 3,7 milhões de m3/mês-1, média de 60 L por veículo. Esse consumo poderia ser minimizado, se o efluente fosse devidamente tratado e reutilizado. Como diversos tipos de efluentes têm sido eficientemente tratados por técnicas eletroquímicas, como a eletrocoagulação (EC) e a eletroflotação (EF), o objetivo principal deste estudo foi desenvolver um sistema de tratamento de efluentes de lavagem de carros por EC, usando eletrodos de alumínio. Parâmetros como pH inicial, corrente elétrica aplicada e tempo de eletrólise foram otimizados por meio de análises físico-químicas e estatísticas. Em sua condição ótima, pH 5, corrente elétrica de 3,5 A e tempo de 20 minutos, o sistema conseguiu reduzir em 73% a demanda química de oxigênio (DQO), 58% de surfactantes e no mínimo 90% a turbidez e os sólidos suspensos totais (SST). Além da simples implantação e operação, a técnica mostrou-se eficiente na recuperação desse tipo de efluente, podendo ser utilizada em sistemas de reúso de água de lavagem de veículos.


ABSTRACT In Brazil, about 32,700 vehicle washing stations consume 3,7 million m3 per month-1, average of 60 L per vehicle. Consumption could be minimized if the effluent was properly treated and reused. As different types of effluents have been effectively treated by electrochemical techniques, such as electrocoagulation (EC) and electrocoagulation (EF), the main objective of this study was to develop a treatment system of carwash wastewater, by EC using electrodes aluminum. Parameters like the initial pH, applied electric current and electrolysis time were optimized by means of physical-chemical analysis and statistics. In its optimum condition, pH 5, electrical current of 3,5 A and time of 20 minutes, the system has managed to reduce by 73% the chemical oxygen demand (COD), 58% of surfactants and a minimum of 90% turbidity and total suspended solids (TSS). Besides the simple installation and operation, the technique was efficient in the recovery of this type of effluent and can be used in reuse system carwash water.

17.
Arq. bras. med. vet. zootec ; 68(6): 1422-1430, nov.-dez. 2016. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-827940

ABSTRACT

The present study aimed to analyse the wave morphology, amplitude, latency, and intervals of the brainstem auditory evoked responses (BAERs) in dogs with central vestibular syndrome (CVS) recorded with surface electrodes. Ten dogs with CVS were examined by mono- and binaural stimulation, using the Neuropack electrodiagnostic system, with stimulus intensities of 90 dBSPL. BAERs examinations revealed morphological changes of waves I, II, III, and V and decreased amplitudes of all waves in 7/10 dogs. P values obtained were = 0.014 for wave I amplitude, 0.031 for II, and III and 0.032 for V. Comparing the latencies of waves I, II, III, and V generated by right and left monoaural stimulation in dogs with CVS, we did not observe significant differences (P > 0.05). No statistical differences were observed for BAERs latencies of the waves recorded after binaural and monaural stimulation (left or right). As far as we know, this is the first study of BAERs using surface electrodes, obtained from dogs with CVS.(AU)


Este estudo destina-se à análise da morfologia, da amplitude, da latência e do intervalo das ondas das respostas evocadas auditivas no tronco cerebral (BAERs) em cães com síndrome vestibular central (CVS) registrados com eletrodos de superfície. Dez cães com CVS foram examinados por estimulação mono e binaural usando um sistema de eletrodiagnóstico Neuropack, com intensidade do estímulo de 90 dBSPL. Os exames BAERs relevaram alterações morfológicas das ondas I, II, III e V, bem como baixas amplitudes para todas as ondas no caso dos 7/10 cães. Os valores de P obtidos foram = 0.014 para ampitude da onda I, 0.031 para a II e 0.032 para a V. Compararam-se as latências das ondas I, II, III e V geradas pelo estímulo monoaural direito e esquerdo em cães com CVS e não foram constatadas diferenças significativas (P > 0.05). Igualmente não foram observadas diferenças estatísticas no caso das latências BAERs no que diz respeito às ondas gravadas depois de estímulos binaural e monoaural (esquerdo ou direito). Pelo que é de conhecimento dos autores da presente pesquisa, este é o primeiro estudo sobre BAERs usando eletrodos de superfície obtidos em cães com CVS.(AU)


Subject(s)
Animals , Dogs , Audiometry, Evoked Response/veterinary , Electrodiagnosis/veterinary , Vestibulocochlear Nerve Diseases/veterinary , Electrodes/veterinary
18.
Arq. bras. oftalmol ; 79(6): 390-394, Nov.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-838747

ABSTRACT

ABSTRACT Purpose: Alternative recording methods have been tested to allow the electroretinogram (ERG) recording in uncooperative patients and/or patients with palpebral alterations, including recordings with skin electrodes. The purpose of this study was to compare ERG recorded with skin electrodes and well-established microfiber electrodes and to determine normative values of ERG parameters for recording with skin electrodes. Methods: Fifty healthy volunteers (17-26 years; mean 20.63 ± 2.01 years) participated in the study. A gold disk skin electrode was placed on the lower orbital rim of a randomly chosen eye. On the contralateral eye, a microfiber electrode was positioned in the lower conjunctival sac. Gold disc electrodes were positioned at the ipsilateral outer canthus of both eyes acting as reference electrodes for the creation of a potential difference. Two ground electrodes were placed on the lobe of each ear. ERGs were recorded according to the International Society of Clinical Electrophysiology Visual (ISCEV) protocol using the VERIS 5.1.9 system for data acquisition and analysis. Results: Both types of electrodes showed similar wave response morphologies. The implicit time of responses between the two electrodes was comparable. On peak-to-peak amplitude, skin electrode recordings showed an amplitude reduction of 61.4% for rod responses, 61.5% for maximal responses, 46.2% for oscillatory potentials, 57.4% for cone responses, and 54.4% for 30Hz-flicker responses, when compared with microfiber electrode recordings. Based on these findings, normative values for peak-to-peak amplitude and implicit time to be used as a reference for ERGs recorded with skin electrodes were determined. Conclusions: ERGs recorded with skin electrodes presented lower peak-to-peak amplitude compared with microfiber electrodes. However, using appropriate normative values, skin electrodes may be useful for specific target populations such as uncooperative infants and/or patients with ocular surface alterations.


RESUMO Objetivo: O eletrorretinograma de campo total (ERG) em pacientes não colaborativos e/ou com alterações palpebrais pode ser registrado com diferentes métodos de captação de respostas, dentre eles os eletrodos de pele. O objetivo deste estudo foi comparar o eletroretinograma obtido com eletrodos de pele e eletrodos de microfibra, determinando valores normativos para os parâmetros registrados com eletrodos de pele. Métodos: Cinquenta voluntários saudáveis (17-26 anos; média 20,63 ± 2,01) participaram deste estudo. Um eletrodo de cúpula de ouro foi aderido à pele na margem orbital inferior de um dos olhos escolhido ao acaso. No olho contralateral, um eletrodo de microfibra foi posicionado no saco conjuntival inferior. Eletrodos de cúpula de ouro foram posicionados na região lateral de cada olho para a formação da diferença de potencial com o eletrodo ativo. Dois eletrodos terra foram posicionados no lobo de cada orelha. O eletrorretinograma foi registrado de acordo com o protocolo da ISCEV (Sociedade Internacional de Eletrofisiologia Visual), com o sistema VERIS 5.1.9 para aquisição e análise dos registros. Resultados: Os dois tipos de eletrodos apresentaram morfologias de onda similares. O tempo implícito das respostas foi comparável entre os dois tipos de eletrodo. Os registros feitos com eletrodo de pele quando comparados aos registros com eletrodos de microfibra mostraram reduções na amplitude das ondas, de 61,4% para resposta de bastonetes, 61,5% para resposta máxima, 46,2% para potenciais oscilatórios, 57,4% para resposta de cones, e 54,4% para flicker 30Hz. Baseado nestes resultados, foram determinados valores normativos para amplitude e tempo de implícito para ERGs obtidos com eletrodos de pele. Conclusões: ERGs registrados com eletrodos de pele apresentam respostas com amplitudes menores quando comparados aos registrados com eletrodos de microfibra. No entanto, usando valores normativos apropriados, os eletrodos de pele podem ser uma alternativa útil para populações especificas como pacientes não colaborativos e/ou com alterações palpebrais.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Retina/physiology , Visual Fields/physiology , Electroretinography/methods , Galvanic Skin Response/physiology , Dark Adaptation , Electrodes , Electroretinography/instrumentation
19.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 28(4): 147-154, out.-dez. 2015. ilus, tab
Article in Portuguese | LILACS | ID: lil-788751

ABSTRACT

Os cabos-eletrodos de cardiodesfibriladores com revestimento de silicone Riata e Riata ST foramextensamente implantados entre os anos de 2003 e 2010. Sua distribuição, porém, foi interrompida após aobservação de exteriorização dos condutores por falha do isolante em diversos casos de mau funcionamento.Esses cabos-eletrodos foram classificados como classe I de recall pelo Food and Drug Administration. Diversosestudos foram realizados desde então para se determinar a incidência e a prevalência de extrusão dos condutores epara avaliar sua correlação com falha elétrica. Também tem sido estudado o melhor método de rastreio e como seconduzir os pacientes portadores desses cabos-eletrodos.


The cardioverter-defibrillator leads with Riata silicone coating and Riata ST were widely deployed between 2003 and 2010. Its distribution, however, was discontinued after observation of externalization of conductors due to insulation failure in several cases of malfunction. These leads were classified as Class I Recall by the Food and Drug Administration. Several studies have been performed since then to determine the incidence and prevalence of extrusion of the conductors and to evaluate their correlation with electrical failure. The best screening method and how to conduct patients with these leads have also been investigated.


Subject(s)
Humans , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Electrodes, Implanted , Equipment Failure , Benchmarking/methods , Medical Device Recalls , Death, Sudden, Cardiac/prevention & control , Pacemaker, Artificial , Therapeutics/methods
20.
Arq. bras. med. vet. zootec ; 67(5): 1457-1460, tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1095984

ABSTRACT

Evocado auditivo de respostas ­ BAER ) foi gravado utilizando eletrodos de superfície em sete cães Mastiff argentino saudáveis para estimulações monoaural e binaural em intensidades sonoras de 90 dB NPS . As latências e amplitudes das ondas I, III e V bem como os intervalos InterWave I- III , III -V e IV foram calculados. As diferenças estatísticas foram obtidas para as ondas III e latências V, amplitudes das ondas III e intervalos I- III e I-V entre mono e estimulação binaural. Por serem uma das raças geneticamente predispostas à surdez congênita, obtendo valores de referência BAER, os cães Mastiff argentino têm uma importância clínica especial.(AU)


Subject(s)
Animals , Dogs , Correction of Hearing Impairment/veterinary , Electrodes/veterinary , Evoked Potentials, Auditory
SELECTION OF CITATIONS
SEARCH DETAIL