Arq. bras. cardiol ; 115(6): 1114-1124, dez. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152928

ABSTRACT

Resumo Fundamento Remoção de cabos-eletrodos de dispositivos cardíacos eletrônicos implantáveis (DCEI) é procedimento pouco frequente e sua realização exige longo treinamento profissional e infraestrutura adequada. Objetivos Avaliar a efetividade e a segurança da remoção de cabos-eletrodos de DCEI e determinar fatores de risco para complicações cirúrgicas e mortalidade em 30 dias. Métodos Estudo prospectivo com dados derivados da prática clínica. De janeiro/2014 a abril/2020, foram incluídos, consecutivamente, 365 pacientes submetidos à remoção de cabos-eletrodos, independentemente da indicação e técnica cirúrgica utilizada. Os desfechos primários foram: taxa de sucesso do procedimento, taxa combinada de complicações maiores e morte intraoperatória. Os desfechos secundários foram: fatores de risco para complicações intraoperatórias maiores e morte em 30 dias. Empregou-se análise univariada e multivariada, com nível de significância de 5%. Resultados A taxa de sucesso do procedimento foi de 96,7%, sendo 90,1% de sucesso completo e 6,6% de sucesso clínico. Complicações maiores intraoperatórias ocorreram em 15 (4,1%) pacientes. Fatores preditores de complicações maiores foram: tempo de implante dos cabos-eletrodos ≥ 7 anos (OR= 3,78, p= 0,046) e mudança de estratégia cirúrgica (OR= 5,30, p= 0,023). Classe funcional III-IV (OR= 6,98, p<0,001), insuficiência renal (OR= 5,75, p=0,001), infecção no DCEI (OR= 13,30, p<0,001), número de procedimentos realizados (OR= 77,32, p<0,001) e complicações maiores intraoperatórias (OR= 38,84, p<0,001) foram fatores preditores para mortalidade em 30 dias. Conclusões Os resultados desse estudo, que é o maior registro prospectivo de remoção de cabos-eletrodos da América Latina, confirmam a segurança e a efetividade desse procedimento no cenário da prática clínica real. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Abstract Background Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time ≥ 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Subject(s)
Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Prospective Studies , Retrospective Studies , Treatment Outcome , Device Removal
3.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(1): 46-48, jan.-mar.2014.
Article in Portuguese | LILACS, SES-SP | ID: lil-767319

ABSTRACT

Relatam-se dois casos de pacientes portadores de marcapasso definitivo bifocal direito de segurança, totalmente dependentes de estimulação cardíaca artificial. Durante o seguimento, em ambos ocorreu perda da estimulação por um dos cabos-eletrodos ventriculares. A estimulação foi mantida pelo segundo cabo-eletrodo e os pacientes não relataram sintomas. A estimulação cardíaca bifocal deve ser considerada em pacientes altamente dependentes da estimulação artificial ou ainda naqueles submetidos à estimulação cardíaca por via epicárdica...


We describe two cases of patients with right bifocal pacing, totally dependent on cardiac pacing. During follow-up, in both cases occurred exit block of one ventricular lead. The pacing was kept by the other lead and the patients reported no symptoms, showing the value of the bifocal pacing in those patients highly dependent on cardiac pacing or in patients undergoing epicardial pacing...


Subject(s)
Humans , Male , Female , Middle Aged , Atrioventricular Block/diagnosis , Electrodes, Implanted/history , Pacemaker, Artificial/history , Sick Sinus Syndrome/diagnosis , Cardiac Pacing, Artificial/methods , Radiography, Thoracic/methods
4.
Braz. j. otorhinolaryngol. (Impr.) ; 78(6): 56-62, nov.-dez. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-660412

ABSTRACT

O implante coclear para pacientes com disacusia grave/profunda revolucionou o modo com que estes interagem com o meio ambiente. A Neurelec desenvolveu um sistema que permite fixação com uso de dois simples parafusos de titânio, sem necessidade de broqueamento do osso do crânio do paciente. Este artigo teve o objetivo de descrever uma casuística de pacientes submetidos a implante coclear com o Digisonic® SP, para mostrar os resultados cirúrgicos e detalhes do procedimento. MÉTODO: Estudo retrospectivo que avaliou os pacientes, no período de 18 meses, submetidos a implante coclear com o Digisonic® SP. Todos os pacientes eram pós-linguais. Coleta dos dados realizada por meio da análise dos prontuários dos pacientes, além de questionário padronizado aplicado nos cirurgiões que realizaram o procedimento. RESULTADOS: Os seis casos implantados com o Digisonic® SP foram realizados por cirurgiões experientes e o tempo cirúrgico variou de 95 a 203 minutos (média de 135 minutos), que é menor do que o descrito com outras formas de fixação. Não houve nenhum tipo de complicação e o ganho auditivo foi satisfatório. CONCLUSÃO: O implante Digisonic® SP desenvolvido pela Neurelec apresentou bons resultados audiológicos em adultos, tempo de cirurgia menor e não ocorreram complicações cirúrgicas ou pós-operatórias.


Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. OBJECTIVE: To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. METHOD: This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. RESULTS: The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. CONCLUSION: The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Cochlear Implants , Cochlear Implantation/instrumentation , Hearing Loss/surgery , Bone Screws , Retrospective Studies , Titanium , Treatment Outcome
5.
Arq. bras. cardiol ; 98(6): e98-e101, jun. 2012. ilus
Article in Portuguese | LILACS | ID: lil-645352

ABSTRACT

A avaliação do limiar de desfibrilação (DFT) durante o implante do cardioversor-desfibrilador (CDI) é uma etapa relevante do procedimento, uma vez que, em até 16% dos pacientes, podemos encontrar elevados DFT. Relatamos o caso de um paciente portador de cardiomiopatia dilatada (CMPD) idiopática submetido a implante de CDI biventricular. Durante o procedimento, apresentou elevado DFT e se mostrou resistente às modalidades terapêuticas usuais. Optamos pelo implante de eletrodo de desfibrilação em veia ázigos, com resolução do quadro.


The evaluation of the defibrillation threshold (DFT) during the implantation of a cardioverter-defibrillator (ICD) is an important stage of the procedure, as a high DFT can be found in up to 16% of patients. We report a patient with idiopathic dilated cardiomyopathy (DCM) submitted to a biventricular ICD implantation. During the procedure, the patient showed a high DFT and showed to be resistant to usual therapeutic modalities. We opted for the azygos vein defibrillation lead implantation, with good resolution.


Subject(s)
Adult , Humans , Male , Azygos Vein , Cardiomyopathy, Dilated/therapy , Defibrillators, Implantable , Electric Countershock/methods , Treatment Outcome
6.
Arq. bras. cardiol ; 95(3): e83-e87, set. 2010. ilus
Article in Portuguese | LILACS | ID: lil-560567

ABSTRACT

Relatamos caso de implantação anômala de eletrodo de marca-passo VVI no ventrículo esquerdo (VE), diagnosticada durante avaliação de rotina, dois anos pós-implante. Trata-se de mulher de 65 anos e soropositiva para doença de Chagas. O eletrocardiograma (ECG) apresentava padrão de bloqueio do ramo direito. A radiografia de tórax em perfil mostrou trajeto com curvatura posterior do eletrodo. No ecocardiograma transtorácico, o diagnóstico final mostrou cateter que penetrava o átrio direito, atravessava o septo interatrial e descia pelo átrio esquerdo e orifício valvar mitral para se implantar na parede lateral do VE. Abordam-se os seguintes aspectos relacionados: possíveis trajetos de implantação, quadro clínico, radiológico, eletrocardiográfico, ecocardiográfico, complicações e opções terapêuticas.


This study reports the case of an anomalous implantation of VVI pacemaker electrode in the left ventricle (LV) diagnosed during routine evaluation, two years after implantation. The patient is a 65-year-old woman with Chagas disease. Electrocardiogram (ECG) revealed a pattern of right branch block. Profile chest X-ray showed electrode with posterior curvature path. In transthoracic echocardiography, the diagnosis revealed that the catheter penetrated the right atrium, crossed the atrial septum, descended through the left atrium and mitral valve orifice and deployed on the LV wall. The following related aspects are addressed: potential deployment routes, clinical, radiological, electrocardiographic and echocardiographic pictures, complications and treatment options.


Relatamos caso de implantación anómala de electrodo de marcapasos VVI en el ventrículo izquierdo (VI), diagnosticada durante evaluación de rutina, dos años post implante. Se trata de mujer de 65 años y seropositiva para enfermedad de Chagas. El electrocardiograma (ECG) presentaba estándar de bloqueo de rama derecha. La radiografía de tórax de perfil mostró trayecto con curvatura posterior del electrodo. En el ecocardiograma transtorácico, el diagnóstico final mostró catéter que penetraba el atrio derecho, atravesaba el septo interatrial y descendía por el atrio izquierdo y orificio valvar mitral para implantarse en la pared lateral del VI. Se abordan los siguientes aspectos relacionados: posibles trayectos de implantación, cuadro clínico, radiológico, electrocardiográfico, ecocardiográfico, complicaciones y opciones terapéuticas.


Subject(s)
Aged , Female , Humans , Chagas Cardiomyopathy/therapy , Electrodes, Implanted , Foreign Bodies/etiology , Medical Errors , Pacemaker, Artificial , Foreign Bodies/diagnosis , Heart Ventricles
7.
Arq. bras. cardiol ; 94(5): e122-e124, maio 2010. ilus
Article in English, Portuguese | LILACS | ID: lil-548099

ABSTRACT

Apresentamos o caso de um paciente portador da forma cardíaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de síncope. Foi submetido a implante de marcapasso artificial definitivo dupla câmara. Após um ano do implante foi diagnosticado deslocamento de eletrodo atrial, sendo submetido a reimplante de eletrodo atrial. Após dois anos do primeiro procedimento cirúrgico, apresentava dispneia aos grandes esforços. Durante a avaliação, foi solicitado ecocardiograma, que detectou a presença de corpo estranho de características metálicas em câmaras cardíacas esquerdas, consistente com eletrodo de marcapasso ectópico.


The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.


Subject(s)
Adult , Humans , Male , Chagas Cardiomyopathy/therapy , Electrodes, Implanted/adverse effects , Foreign-Body Migration , Pacemaker, Artificial/adverse effects , Atrioventricular Block/therapy , Chagas Cardiomyopathy , Reoperation/adverse effects , Ventricular Dysfunction, Left/etiology