Chinese Journal of Immunology ; (12): 1175-1178, 2016.
Article in Chinese | WPRIM | ID: wpr-495090

ABSTRACT

Objective:To compare the performance of chemiluminescent microparticle immunoassay ( CMIA) and enzyme-linked immunosorbent assay ( ELISA) for the determination of Anti-PR3 and Anti-MPO.Methods:Concentration of Anti-PR3 and Anti-MPO in serum samples from 166 patients with autoimmune diseases and 50 healthy donors were determined by using CMIA (Method A) and ELISA(Method B),respectively.The results from both assays were analyzed and compared by statistical methods .Results:Method A showed better intra-assay reproducibility and inter-assay reproducibility than Method B for the determination of high ,medium and low levels of control serum .Both methods met the accuracy requirement .The correlation coefficient of Anti-PR3 and Anti-MPO were 0.987 8 and 0.989 6 for Method A and Method B ,respectively.And the Kappa coefficients were 0.897 and 0.882 for Method A and Method B,respectively.Conclusion:The performance of Method A is superior to Method B for the deter-mination of Anti-PR3 and Anti-MPO, which makes Method A to be a potentially better choice for clinical application .

2.
Journal of Modern Laboratory Medicine ; (4): 16-18, 2015.
Article in Chinese | WPRIM | ID: wpr-476067

ABSTRACT

Objective To compare PCR-SBT to IMS-ELISA in the HLA-B27 detection in the ankylosing spondylitis (AS)pa-tients.Methods Simultaneously,PCR-SBT and IMS-ELISA were used to detect the HLA-B27 expression in peripheral blood samples which were suspected patients with AS from 120 cases.Chisquare test of paired design and the area under curve of receiver operating characteristics of SPSS17.0 software were used to evaluate the value of PCR-SBT and IMS-ELISA in HLA-B27 detection of AS patients.Results Among 120 cases of suspected patients with AS,the positive rates of HLA-B27 detected by PCR-SBT and IMS-ELISA were 45.83%(55/120)and 37.50% (45/120),respectively.There was statistical difference between the two methods in the HLA-B27 detection (χ2 =59.455,P =0.000).The sensibility and spe-cificity of PCR-SBT were 96.36% and 96.92%,respectively.While the sensibility and the specificity of IMS-ELISA were 69.09% and 89.23%,respectively.Area under the curve of two methods were 0.966 and 0.792,respectively.Conclusion In comparison with IMS-ELISA,the sensibility and the specificity of PCR-SBT in HLA-B27 detection were higher in AS diag-nosis,that is to say,PCR-SBT is better in HLA-B27 detection and AS diagnosis.

3.
Chinese Journal of Microbiology and Immunology ; (12): 459-464, 2014.
Article in Chinese | WPRIM | ID: wpr-452265

ABSTRACT

Objective To prepare a human meningococcal reference serum and standardize IgG concentrations to capsular polysaccharides and in vitro bactericidal activities of the reference serum against serogroup A, C, Y and W135 strains.Methods Twenty healthy adults were recruited and given one dose of immunization with tetravalent (serogroups A, C, Y and W135) meningococcal polysaccharide vaccine . Plasma samples were collected and gone through a series of process treatments including defibrination , filtra-tion, and lyophilization to prepare the meningococcal reference serum Men 10.The IgG concentrations of Men10 to capsular polysaccharides of serogroups A , C, Y and W135 were calibrated by using an internation-al reference serum CDC1992 as the standard in enzyme-linked immunosorbent assay (ELISA).Provisional IgG concentrations of Men10 were intensively validated by testing a panel of 12 calibration serum samples from Centers for Disease Control and Prevention , USA ( US CDC) and a panel of 56 serum samples immu-nized with A, C, Y and W135 meningococcal polysaccharide vaccine from Lanzhou Institute of Biological Products Co., Ltd.(LIBP) with the assays using Men10 and CDC1992 as the standard and/or test sam-ples, respectively.The bactericidal titers against serogroup A , C, Y and W135 strains were measured by se-rum bactericidal assay (SBA).Results Four thousand vials (0.5 ml/vial)of lyophilized human meningo-coccal reference serum Men10 were successfully prepared with 2.5%of residual moisture .Reference serum Men10 was sterile and free from contamination by hepatitis B virus , hepatitis C virus , human immunodefi-ciency virus and syphilis .Provisional IgG concentration of Men 10 to capsular polysaccharide of serogroups A, C, Y and W135 was calibrated by using CDC1992 as the standard.Furthermore, IgG concentrations of both panels of 12 CDC calibration serum samples and 56 LIBP serum samples calibrated by using Men 10 as the standard correlated well with those by using CDC1992 as the standard (r=0.99,P<0.05).The IgG concentrations of CDC1992 as calibrated by using Men10 as the standard showed significant correlation with its previously determined values with variation <10%.SBA titers for serotype A , C, Y and W135 strains were established as well .Conclusion A panel of new human meningococcal reference serum Men 10 with accurately calibrated IgG concentration against capsular polysaccharide of serogroups A , C, Y and W135 as well as SBA titers was successfully established .