Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Odovtos (En línea) ; 24(2)ago. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1386595

ABSTRACT

Abstract The aim of this in vitro study was to compare the long-term effect of overnight use of denture cleansers with different chemical compositions on the color stability of denture base polymers (DBPs). The four DBPs evaluated were PEEK (PK group), thermoinjection-molded polyamide (PA group), auto-polymerized polymethylmethacrylate (PMMA) (AP group), and heat-polymerized resin PMMA (HP group). The cleaning agents used were Corega tablet (CT), Protefix tablet (PT), and 0.5% sodium hypochlorite (NaOCl) solution (SH). Distilled water (DW) served as a control. Forty-eight disc-shaped specimens (10mm × 2mm) were prepared from each DBP and randomly immersed in the different storage media (n=12 in each group). Color measurements of the specimens before and after immersion in the denture cleansers were made using a spectrophotometer (VITA Easyshade V). The color changes were measured and recorded in L* a* b*. After 120 d, the CIEDE2000 formula was used to calculate color changes (ΔE00). For analysis of the data, a multivariate analysis of variance was used (p<0.05). The results of the statistical analysis revealed significant color change differences in the DBPs immersed in the various denture cleansers (p<0.05). Groups PA and PK showed the highest values for all solutions. AP-SH showed the highest ΔE00 value in group AP, no significant difference was found between other solutions. In group HP, there was no statistically significant difference between the average ΔE00 values of all solutions. Long-term daily use of the denture cleansers affected the color stability of all the DBPs, although the level of color change was acceptable. Laboratory and clinical studies on the color stability of PEEK are needed to confirm the results of this study.


Resumen El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por termoinyección (grupo PA), polimetilmetacrilato (PMMA) autopolimerizado (grupo AP) y resina PMMA termopolimerizada (grupo HP). Los agentes de limpieza utilizados fueron Corega (CT), Protefix (PT) y la solución de hipoclorito de sodio (NaOCl) al 0,5% (SH). El agua destilada (DW) sirvió de control. Se prepararon 48 especímenes en forma de disco (10mm × 2mm) de cada DBP y se sumergieron al azar en los diferentes medios de almacenamiento (n=12 en cada grupo). Las mediciones del color de las muestras antes y después de la inmersión en los limpiadores de dentaduras se realizaron con un espectrofotómetro (VITA Easyshade V). Los cambios de color se midieron y registraron en L* a* b*. Después de 120 d, se utilizó la fórmula CIEDE2000 para calcular los cambios de color (ΔE00). Para el análisis de los datos, se utilizó un análisis multivariante de la varianza (p<0,05). Los resultados del análisis estadístico revelaron diferencias significativas en el cambio de color de los DBP sumergidos en los distintos limpiadores de dentaduras (p<0,05). Los grupos PA y PK mostraron los valores más altos para todas las soluciones. AP-SH mostró el valor ΔE00 más alto en el grupo AP, no se encontraron diferencias significativas entre las demás soluciones. En el grupo HP, no hubo diferencias estadísticamente significativas entre los valores medios de ΔE00 de todas las soluciones. El uso diario a largo plazo de los limpiadores de dentaduras afectó a la estabilidad del color de todos los DBP, aunque el nivel de cambio de color fue aceptable. Se necesitan estudios de laboratorio y clínicos sobre la estabilidad del color del PEEK para confirmar los resultados de este estudio.


Subject(s)
Polymers , Prosthesis Coloring , Denture Cleansers , Polymethyl Methacrylate
2.
Odovtos (En línea) ; 23(3)dic. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386563

ABSTRACT

ABSTRACT: CAD/CAM blocks are widely used in dental restorations around the world. This study aimed to investigate the effects of different polishing and finishing systems on surface roughness and color change of resin-based CAD/CAM blocks. In this study, material samples of 2×7×12mm were prepared. In three different experimental groups, surface polishing was carried out with one-step, two-step and multi-step polishing systems. The samples in one subgroup of each experimental group were polished with the diamond paste. Once the initial roughness and color values of the samples were measured using a profilometer and a spectrophotometer, the samples were immersed in coffee. Surface roughness and color change (ΔE00) results were statistically analyzed using two-way variance analysis (ANOVA). Finishing and polishing systems created significantly different levels of surface roughness on the hybrid ceramic block (Vita Enamic) but not on the composites block (Brilliant Crios, Grandio Blocs). While the two-step and multi-step finishing and polishing systems produced the lowest color change on hybrid ceramic blocks, one-step and two-step systems achieved this on composite blocks (p<0.05). In all test groups, the supplementary polishing performed after regular polishing procedures helped us reduce the surface roughness and color change on CAD/CAM blocks. The findings obtained in this study suggest that one and two-step polishing systems are more suitable for resin-based composite CAD/CAM blocks; for hybrid ceramic CAD/CAM blocks, on the other hand, two and multi-step finishing and polishing systems seem to be more efficient concerning lower surface roughness and resistance to color changes.


RESUMEN: Los bloques CAD/CAM son ampliamente utilizados en las restauraciones dentales, alrededor del mundo. El objetivo de este estudio es investigar los efectos de diferentes sistemas de pulido y acabado sobre la rugosidad de la superficie y el cambio de color de los bloques CAD/CAM de resina. En este estudio se prepararon muestras de material de 2×7×12mm. El pulido de la superficie se llevó a cabo en tres grupos experimentales con sistemas de pulido de un paso, de dos pasos y de varios pasos. Las muestras de un subgrupo de cada grupo experimental se pulieron con la pasta de diamante. Una vez medidos los valores iniciales de rugosidad y color de las muestras mediante un perfilómetro y un espectrofotómetro, las muestras se sumergieron en café. Los resultados de la rugosidad superficial y el cambio de color (ΔE00) se analizaron estadísticamente mediante un análisis de varianza de dos vías (ANOVA). Los sistemas de acabado y pulido crearon niveles de rugosidad superficial significativamente diferentes en el bloque cerámica híbrida (Vita Enamic) pero no en el bloque de composites (Brilliant Crios, Grandio Blocs). Mientras que los sistemas de acabado y pulido de dos y varios pasos produjeron el menor cambio de color en los bloques de cerámica híbrida, los sistemas de un paso y dos pasos lo consiguieron en los bloques de composite (p<0,05). En todos los grupos de prueba, el pulido suplementario realizado después de los procedimientos de pulido regulares nos ayudó a reducir la rugosidad de la superficie y el cambio de color en los bloques CAD/CAM. Los hallazgos obtenidos en este estudio sugieren que los sistemas de pulido de uno y dos pasos son más adecuados para los bloques CAD/CAM de resina; en cambio, para los bloques CAD/CAM de cerámica híbrida, los sistemas de acabado y pulido de dos y varios pasos parecen ser más eficientes en lo que respecta a la menor rugosidad de la superficie y la resistencia a los cambios de color.


Subject(s)
Resins, Synthetic , Color , Dental Restoration, Permanent/instrumentation
3.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386541

ABSTRACT

ABSTRACT: Objective: The aim of this study was to evaluate and compare the effects of the superficial application of two different modeling resins on the surface microhardness and discoloration of composite resins. Material and Methods: The present study used two different composites and modeling resins. The composites were placed in plastic molds. Subsequently, the modeling resins were applied on the surface of the two composite groups. The microhardness and color pertaining to all the groups were evaluated. The current study used the One-Way ANOVA and Kruskal Wallis tests, in order to perform the statistical evaluation (p<0.05). Results: The present study compared the microhardness pertaining to the groups and the highest microhardness values were observed in the Estelite Asteria group (none), whereas the lowest values were observed in the GC Essentia group (Ultradent). Moreover, the current study evaluated the color stability and the greatest discoloration was observed in the control group of the GC Essentia group, whereas the least discoloration was observed in the Estelite Asteria group that included the samples prepared using Ultradent Wetting Resin. Conclusions: The results of the present study demonstrated that the use of modeling resins, which facilitate the placement of composite resins, reduced the microhardness and discoloration of composite resins. The aforementioned effect can be attributed to the variations in the structure of the filling. However, further studies are warranted to support and verify the results of the current study.


RESUMEN: Objetivo: El objetivo del presente estudio fue evaluar y comparar los efectos de la aplicación superficial de dos resinas humectantes sobre la microdureza superficial y la decoloración de las resinas compuestas. Material y métodos: El presente estudio utilizó dos resinas humectantes y resinas de modelado diferentes. Las resinas compuestas se colocaron en moldes de plástico. Posteriormente, se aplicaron las resinas humectantes sobre la superficie de los dos grupos. Se evaluó la microdureza y el color de todos los grupos. El presente estudio utilizó las pruebas One-Way ANOVA y Kruskal Wallis, para realizar la evaluación estadística (p<0.05). Resultados: Los valores más altos de microdureza se observaron en el grupo Estelite Asteria, mientras que los menores valores se observaron en el grupo GC Essentia (Ultradent). La mayor decoloración se observó en el grupo control o el grupo GC Essentia, mientras que la menor decoloración se observó en el grupo Estelite Asteria con Ultradent Wetting Resin. Conclusiones: Los resultados del presente estudio demostraron que el uso de resinas humectantes, que facilitan la colocación de resinas compuestas, redujo la microdureza y decoloración de las resinas compuestas. El efecto mencionado anteriormente se puede atribuir a las variaciones en la estructura del relleno. Sin embargo, se necesitan más estudios para respaldar y verificar los resultados del presente estudio.


Subject(s)
Composite Resins/analysis , Hardness , Hardness Tests , Tooth Discoloration , Turkey
4.
Odovtos (En línea) ; 23(1)abr. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386521

ABSTRACT

Abstract: Objective: This study investigated the effects of three types of mouthwash on the color stability of three resin-based restorative materials (nanohybrid resin composite, sonic-activated bulk-fill material, and compomer). Materials and Methods: To this end, 120 cylindrical disc specimens were prepared and polished, after which they were incubated in distilled water for 24 hours for post-polymerization. The baseline color values of each specimen were measured with a spectrophotometer, then the specimens were randomly divided into four groups. Following immersion in the mouthwashes for 24 hours, the specimens were rinsed with distilled water and dried before the color measurement was repeated. The values of color change (ΔE₀₀) were subsequently calculated. A two-way analysis of variance and Duncan's post hoc multiple comparison tests were conducted to determine statistically significant differences among the restorative materials. Results: All samples showed discoloration after immersion, albeit some instances of discoloration were imperceptible. In this respect, a statistically significant difference was found among the restorative materials and mouthwashes (p<0.05). Imperceptible ΔE₀₀ values were derived on the nanohybrid resin composite and compomer, but perceptible and acceptable ΔE₀₀ values were detected on the sonic-activated bulk-fill materials (p<0.05). The clinically unacceptable discoloration was observed on the sonic-activated bulk-fill composite immersed in Listerine®. Conclusions: Clinicians should make recommendations based on the potential staining capacity of mouthwashes prescribed for daily use in restorative materials. In this way, the need for renewal of restorations due to discoloration could be avoided.


Resumen: Objetivo: Este estudio investigó los efectos de tres tipos de enjuague bucal en la estabilidad del color de tres materiales de restauración a base de resina (resina nanohíbrida, resina bulk-fill de activación sónica y compómero). Materiales y Métodos: Para ello se prepararon y pulieron 120 muestras de discos cilíndricos, después de lo cual se incubaron en agua destilada durante 24 horas pospolimerización. Los valores de color de base de cada muestra se midieron con un espectrofotómetro, después las muestras se dividieron aleatoriamente en cuatro grupos. Tras la inmersión en los enjuagues bucales durante 24 horas, los especímenes se enjuagaron con agua destilada y se secaron antes de repetir la medición del color. Posteriormente se calcularon los valores de cambio de color (ΔE₀₀). Se llevó a cabo un análisis bidireccional de la varianza y las pruebas de comparación múltiple post hoc de Duncan para determinar las diferencias estadísticamente significativas entre los materiales de restauración. Resultados: Todas las muestras mostraron decoloración después de la inmersión, aunque algunos casos esta fue imperceptible. Se encontró una diferencia estadísticamente significativa entre los materiales de restauración y los enjuagues bucales (p<0,05). Se obtuvieron valores imperceptibles de ΔE₀₀ en el compuesto de resina nanohíbrida y el compómero, pero se detectaron valores perceptibles y aceptables de ΔE₀₀ en la resina bulk-fill activada sónicamente (p<0,05). Se observó una decoloración clínicamente inaceptable en la resina bulk-fill activada sónicamente inmersa en Listerine®. Conclusiones: Los clínicos deben hacer recomendaciones basadas en la capacidad potencial de coloración de los enjuagues bucales prescritos para uso diario en los materiales de restauración. De esta manera, se podría evitar la necesidad de renovar las restauraciones debido a la decoloración.


Subject(s)
Tooth Discoloration , Mouthwashes/analysis , Resins
SELECTION OF CITATIONS
SEARCH DETAIL