Int. j. odontostomatol. (Print) ; 9(3): 483-487, dic. 2015. ilus
Article in English | LILACS | ID: lil-775475

ABSTRACT

The aim was to evaluate the differences of implant stability quotient (ISQ) between implants with external hexagon and Morse taper connectors. The study had a split mouth design, composed by 10 patients who received hybrid protocol prosthesis. In total, 40 implants (3.75 x 13 mm) were installed: on the right side, 20 external hexagon, and on the left, 20 Morse taper. After two years in function, the stability test was applied by using the MRI machine Osstell ISQ directly on the implants and on the abutments. Considering the measurements made on the implants, there were differences between HE and CM mesial (p= 0.011), lingual (p= 0.003) and distal (p= 0.006). Considering the measurements made on the abutments, there were differences between HE and CM on the buccal (p= 0.020) and lingual (p= 0.004). The trend and higher values are for the CM group. The values for Morse taper implants were always higher in a statistically significant manner, when compared to the external hexagon.


El objetivo fue evaluar las diferencias del coeficiente de estabilidad de implantes comparando los de conexión de hexágono externo (HE) y cono morse (CM). El estudio tuvo un diseño de boca dividida, siendo compuesta por 10 pacientes que recibieron protocolos protésicos de tipo hibrido. En total, 40 implantes (3,75x13 mm) fueron instalados: en el lado derecho, 20 implantes de hexágono externo y en el lado izquierdo, 20 implantes de cono morse. Después de dos años en función, la prueba de estabilidad fue aplicada utilizando una maquina MRI, Ostell ISQ directamente sobre los implantes y pilares. Considerando las medidas en los implantes, hubo diferencias entre los implantes HE y CM en mesial (p= 0,011), lingual (p= 0,003) y distal (p= 0,006). Considerando las medidas en los pilares, hubo diferenciasentre HE y CM en el sector bucal (p= 0,020) y lingual (p= 0,004). Los valores mas altos se obtuvieron en CM; los valores de las conexión tipo cono morse presentaron mayor estabilidad al comparase con los implantes de conexión de hexágono externo.


Subject(s)
Humans , Dental Implants , Dental Abutments , Dental Implantation , Resonance Frequency Analysis
2.
Rev. Asoc. Odontol. Argent ; 102(4): 166-171, oct.-dic. 2014. ilus, tab
Article in Spanish | LILACS | ID: lil-744938

ABSTRACT

Objetivo: en ciertas situaciones clínicas, puede ser necesario cambiar la orientación del sensor Osstell ISQ(TM) pero se desconocen los efectos de dicha modificación. El objetivo de la investigación fue verificar si los valores del coeficiente de estabilidad del implante (ISQ) difieren según cuál sea la orientación del sensor. Materiales y métodos: utilizando Osstell ISQ (Osstell Integration Diagnosis AB, Gotemburgo, Suecia), se midió el ISQ de 102 implantes de superficie Osteotite (Biomet 3i, Palm Beach Gardens, FL., Estados Unidos), con dos orientaciones diferentes del sensor: paralelo al SmartPeg (Integration Diagnostics AB, Gotemburg, Suecia) (vertical) y perpendicular a él (horizontal). Los valores de ISQ registrados para cada orientación se compararon mediante prueba de Wilcoxon para muestras relacionadas. Resultados: los valores de IsQ verticales difirieron de los ISQ horizontales en el 62,7 por ciento de los casos. Las diferencias entre los grupos resultaron estadísticamente significativas (P<0,05). La media de ISQ vertical (76,29) fue mayor que la de ISQ horizontal (74,78). Conclusión: si la situación clínica amerita un cambio de orientación del sensor, se deberá tener en cuenta que la medida de ISQ vertical observada podría diferir significativamente del valor que se habría obtenido realizando la medición de manera convencional.


Subject(s)
Humans , /methods , Osseointegration/physiology , Dental Instruments , Data Interpretation, Statistical