Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Distúrb. comun ; 31(4): 672-682, dez., 2019. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1392242

ABSTRACT

Introduction: Cervical auscultation is a complementary evaluation to dysphagia clinical evaluation. Objective: To establish the swallowing sounds profile in post-stroke patients' group. Methods: Clinical cross-sectional study, whose collection and acoustic analysis was performed through the electronic stethoscope of the Littman brand (model 4100) and clinical evaluation of dysphagia, with the collection of 45 swallows of liquids and 9 swallows dried. Results: Sample composed of nine post stroke individuals with an average age of 54.33-year-old; 55.6% of patients with swallowing disease. The frequency varies between 20-500 Hz; the dry swallowing frequencies occurred in 250 Hz in swallowing without alteration, and between 20 Hz and 249 Hz in disease. For the swallowing of liquids, between 20Hz and 249 Hz without alteration, and 250 in Hz disease. The average dry swallowing time was given in 110.3 ms (SD ± 38. 6 ms) and with liquids in 111.6 ms (SD ± 36.5 ms). The average time between the dry swallowing events was 125 ms (SD ± 54.74 ms) in swallowing without alteration and of 98.60 ms (SD ± 18. 66 ms) in disease; in liquid swallowing it was 100.20 ms (DP ± 31.01 ms) without alteration, and 120.68 ms (SD ± 38.52 ms) in the swallowing disease. Conclusion: The digital stethoscope showed itself as an instrumental possibility for the collection, but for the acoustic analysis it is not productive. The results of the dry and liquid swallowing were: average time around 110 ms and at low frequency, varying between 20 Hz and 500 Hz for both consistencies, with post stroke patients.


Introdução: A ausculta cervical caracteriza-se como um exame complementar à avaliação clínica da disfagia. Objetivo: Estabelecer o perfil sonoro dos ruídos da deglutição de um grupo de pacientes pós-AVC. Método: Estudo clínico de caráter transversal, cuja coleta e análise acústica foram realizadas através do estetoscópio eletrônico da marca Littman (modelo 4100) e avaliação clínica da disfagia, com a coleta de 45 deglutições de líquidos e nove deglutições secas. Resultados: Amostra composta por nove sujeitos pós-AVC com idade média de 54,33 anos; 55,6% dos pacientes com alteração de deglutição. As frequências variaram entre 20-500 Hz, as frequências da deglutição seca ocorreram em 250 Hz na deglutição sem alteração e entre 20 Hz a 249 Hz na alterada; para a deglutição de líquidos entre 20 Hz a 249 Hz sem alteração e de 250 Hz na alterada. O tempo médio da deglutição seca se deu em 110,3 ms (dp ±38,6 ms) e com líquidos em 111,6 ms (dp ± 36,5 ms). O tempo médio entre os eventos de deglutição seca foi de 125 ms (dp ± 54,74 ms) na deglutição sem alteração e de 98,60 ms (dp ± 18,66 ms) na alterada; na deglutição líquida foi de 100,20 ms (dp ± 31,01 ms) sem alteração e de 120,68 ms ± 38,52 ms na deglutição alterada. Conclusão: O estetoscópio digital mostrou-se como uma possibilidade instrumental para a coleta, contudo para a análise acústica se mostrou pouco objetivo. Os resultados encontrados com a deglutição seca e com a consistência líquida foram: tempo médio em torno de 110 ms e em frequência baixa, variando entre 20 Hz e 500 Hz para ambas as consistências, junto aos pacientes pós-AVC.


Objetivo: establecer el perfil sonoro de los sonidos de deglución después de um accidente cerebrovascular. Método: estudio clínico de carácter transversal, cuya colección y análisis acústico se realizó a través del estetoscopio electrónico de la marca Littman (modelo 4100) y evaluación clínica de la disfagia, con la recolección de 45 degluticiones de líquidos y nueve degluticiones secas. Resultados: muestra compuesta por nueve sujetos después de um accidente cerebrovascular, con una edad promedio de 54,33 años; 55,6% con cambio de deglución. Las frecuencias variaram entre 20-500 Hz, de la deglución seca ocurrieron en 250 Hz en tragar sin alteración y entre 20 Hz el 249 Hz en alterada; la deglución de líquidos entre 20 Hz el 249 Hz sin alteración y 250 Hz en la deglución alterada. El tiempo medio de deglución en seco se dio en 110,3ms y con líquidos en 111,6ms. El tiempo promedio entre los eventos de deglución seca fue 125 ms en la deglución sin alteración y de 98,60 ms en la deglución alterada. En la deglución líquida fue 100,20 ms sin alteración y 120,68 ms en la deglución alterada. Conclusión: el estetoscopio digital se demostró como posibilidad instrumental de la colección, pero para el análisis acústico demostró poca meta. Los resultados de la deglución seca y com líquidos encontrados fueron: tiempo promedio en la deglución alterada de 110 ms y a baja frecuencia, variando entre 20 Hz y 500 Hz para ambos consistencias, con pacientes después de um accidente cerebrovascular.


Subject(s)
Humans , Male , Middle Aged , Deglutition Disorders , Stroke , Deglutition , Noise , Stethoscopes
2.
Rev. mex. ing. bioméd ; 39(2): 205-216, may.-ago. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-961335

ABSTRACT

Resumen: La evaluación automática de sonidos de auscultación cervical (AC) es una herramienta no invasiva para evaluación de la deglución. Sin embargo, los eventos deglutorios pueden verse enmascarados por fuentes de ruido. Este trabajo propone una metodología de caracterización y clasificación de señales de AC con alta resolución temporal a partir de estetoscopio, para discriminar entre sonidos deglutorios y asociados a ruido. Se adquirieron señales de AC en 10 sujetos sanos durante tres pruebas: toma de líquido, pronunciación del fonema /a/ y aclaramiento de garganta. Se extrajeron características de la señal de AC basadas en coeficientes cepstrales en la escala Mel, transformada wavelet discreta y entropía de Shannon. Las características con mayor relevancia fueron utilizadas como entrada a una máquina de vectores de soporte. Utilizando ventanas de 60 ms - alta resolución temporal - y validación cruzada, se obtuvieron exactitudes del 97.7% para detección de eventos acústicos y 91.7% para sonidos deglutorios. El método propuesto permite clasificación de sonidos deglutorios utilizando estetoscopio -dispositivo común en la práctica clínica- con exactitud comparable a otros trabajos que tienen menor resolución temporal o que utilizan otro tipo de sensores. Este trabajo constituye una primera etapa en el desarrollo de un algoritmo robusto para clasificación de sonidos deglutorios asociados a desórdenes de la deglución, a partir de auscultación cervical, para fines de diagnóstico automático.


Abstract: Automatic evaluation of cervical auscultation sounds (AC) is a non-invasive tool for swallowing assessment. However, the swallowing events could be perturbed by acoustic noise. This paper proposes a methodology of characterization and classification of AC signals acquired by stethoscope with high temporal resolution, in order to discriminate between swallowing sounds and other acoustic noise. AC signals from 10 healthy individuals were acquired with stethoscope during three tasks: liquid ingestion, phoneme /a/ pronunciation and throat clearing. Features based in Mel frequency cepstral coefficients, discrete wavelet transform and Shannon entropy, were extracted. Features with highest Fisher's discriminant ratio were used as input of a support vector machine. By application of 60 ms windows and cross validation, the obtained accuracies were 97.7% for acoustic event detection and 91.7% for swallowing sound detection. The proposed method allows classification swallowing sounds with higher temporal resolution­ than other works but with comparable accuracy. Furthermore, the use of stethoscope could lead to better acceptation than other sensors by physicians, because it is a common device in clinical practice. This work is a first stage in the development of a robust classification algorithm for sounds in swallowing disorders, oriented to automatic diagnosis.

3.
Rev. Inst. Nac. Hig ; 49(2): 34-41, 2018. ilus, graf
Article in Spanish | LILACS, LIVECS | ID: biblio-1096298

ABSTRACT

El artículo presenta el desarrollo de una tarjeta de adquisición de datos (TAD) para uso biomédico. Este diseño forma parte de un sistema que permite realizar un análisis comparativo entre los sonidos cardiopulmonares (SC) y el electrocardiograma de alta definición (ECGAR). La TAD reportada digitaliza simultáneamente tres señales adquiridas. Los dos primeros canales digitalizan las señales correspondientes a las derivaciones dI y dIII del ECGAR. El tercer canal digitaliza la señal captada del SC. El instrumento consta de dos partes, una etapa de hardware para adquirir la señal y un software para la manipulación de datos en la computadora. El hardware está compuesto por un microcontrolador de alto rendimiento, una interfaz de comunicación con la computadora vía USB y los circuitos de seguridad eléctrica inherentes a un equipo médico. El software permite la adquisición de las señales transmitidas desde el hardware, su visualización gráfica y el almacenamiento de la información en una base de datos. Las pruebas de funcionamiento demostraron errores inferiores al 0,1 % en las mediciones de amplitud y no se registró perdida de información en la comunicación con la computadora


The paper reports the development of a data acquisition card (TAD) for biomedical use. This design is part of a system that allows a comparative analysis between cardiopulmonary sounds (SC) and the high-definition electrocardiogram (ECGAR). The reported TAD simultaneously digitizes three acquired signals. The channels 1 and 2 digitize the ECGAR signals corresponding to leads dI and dIII. The channel 3 digitizes to SC captured signal. The instrument consists of two parts, a hardware for acquire the signal and a software for data manipulation in the computer. The hardware consists of a high performance microcontroller, a USB communication interface with the computer and the electrical safety circuits inherent to medical equipment. The software allows the signals acquisition transmitted from the hardware, its graphic visualization and the information storage in a database. The performance tests showed errors less than 0.1 % in amplitude measurements and no loss of information in the communication with the computer


Subject(s)
Humans , Male , Female , Stethoscopes , Electrocardiography/instrumentation , Signal Processing, Computer-Assisted , Cardiovascular Diseases
5.
Rev. Fac. Med. UNAM ; 59(6): 43-57, nov.-dic. 2016. tab, graf
Article in Spanish | LILACS | ID: biblio-957116

ABSTRACT

Resumen La exploración adecuada del tórax tiene una secuencia que ayuda al clínico a seguir varios pasos e integrar sus hallazgos en síndromes, mismos que lo llevarán con más seguridad hacia el diagnóstico más adecuado. Al cumplirse los 200 años de la invención del estetoscopio por René Laënec, tomamos esta oportunidad para recordarlo y detallar los pasos de la exploración del tórax. El hecho de contar con más herramientas tecnológicas para el diagnóstico, no le resta importancia a esta etapa tan importante de la relación entre el médico y su paciente, que es la exploración.


Abstract Thoracic exploration has a sequence of steps that help the clinician to integrate its findings in syndromes, which will lead the physician to better diagnosis. This year the stethoscope, invented by René Laënec, turns 200 years old and we use this opportunity to remember him and provide a detailed description of the thoracic exploration. To have access to more sophisticated diagnostic tools should not diminish the relevance of a direct exploration of the patient, which is a very important step in the patient-physician relationship.

6.
Rev. bioméd. (México) ; 27(1): 31-41, ene.-abr. 2016. graf
Article in Spanish | LILACS | ID: biblio-1041919

ABSTRACT

Resumen Serendipia, una palabra común en la literatura científica en inglés; pero que luego de casi 300 años de su acuñación no ha sido aceptada por la Real Academia Española. En todo caso, se refiere a los descubrimientos realizados por accidente, casualidad o hechos fortuitos, pero siempre detrás de una mente acuciosa, capaz de comprender, explicar y aplicar, eso que algunos llaman accidentes afortunados, que incluyen desde la ley de la gravedad, la invención de la máquina de vapor y muchos otros inventos, incluyendo descubrimientos de uso cotidiano en la odontología. En esta última rama de las ciencias biológicas, se recopila información referente al estetoscopio, la anestesia, los rayos x, la penicilina y los implantes dentales, todos producto de la serendipia.


Abstract Serendipity is an usual word in the English scientific literature; but after almost 300 years the word still is not accepted by the Real Academia Española. However, it means the discovery by accident, chance or fortuity but always behind a diligent mind, capable of comprehend, explain and apply those fortuity accidents, such as the gravity discover, the invention of the vapor machine and others more, including some inventions of daily use in dentistry. In this branch of biological science, we collect information about the stethoscope, anesthesia, x-rays, penicillin and dental implants all of them have occurred by serendipity.

7.
Rev. chil. infectol ; 33(1): 19-25, feb. 2016. tab
Article in Spanish | LILACS | ID: lil-776955

ABSTRACT

Healthcare-associated infections (HCAI) are a problem worldwide. In our country, the estimated incidence of HCAI is 70,000 per year. This results in an increase in the average length of hospital stay by 10 days per patient, an estimated annual cost of US $ 70 million and an overstay of 700 thousand bed days a year. For over 30 years stethoscopes have been considered as potential HCAI vectors, since pathogens like methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococcus strains adhere and colonize them. These organisms can be transmitted between patients if the instruments are not sanitized. Several studies conclude that disinfecting the stethoscope with isopropyl alcohol eliminates up to 99% of bacteria. Simple, economic measures such as implementation of guidelines for stethoscope disinfection are a clear opportunity for preventing infections.


Las infecciones asociadas a la atención de la salud (IAAS) son un problema a mundial. Sólo en nuestro país se estima una incidencia de 70.000 al año, lo que se traduce en un aumento de la estadía hospitalaria en 10 días promedio por paciente, un costo anual estimado en 70 millones de dólares y una sobre-estadía de 700 mil días cama al año. La evidencia señala que diferentes instrumentos de uso hospitalario resultan contaminados por patógenos; entre ellos, el estetoscopio se ha identificado como potencial vector de IAAS hace más de 30 años y adquiere gran relevancia al ser de uso generalizado. Microorganismos patógenos, incluyendo cepas de Staphylococcus aureus resistente a meticilina y cepas de Enterococcus resistente a vancomicina se adhieren y contaminan los estetoscopios, pudiendo transmitirse a otros pacientes si no son desinfectados. Diversos estudios concluyen que la desinfección del estetoscopio con alcohol isopropílico elimina hasta 99% de estas y otras bacterias, por lo que existe una clara oportunidad para aportar a la prevención de las IAAS, interviniendo a través de la implementación de medidas sencillas, económicas y operativas al corto plazo, normando por ejemplo la limpieza del estetoscopio.


Subject(s)
Humans , Disinfection/statistics & numerical data , Equipment Contamination/statistics & numerical data , Stethoscopes/microbiology , Cross Infection/etiology , Cross Infection/microbiology , Disinfection/methods , Gram-Negative Bacteria/classification , Gram-Negative Bacteria/isolation & purification , Gram-Positive Bacteria/classification , Gram-Positive Bacteria/isolation & purification
8.
Saude e pesqui. (Impr.) ; 8(3): 577-584, set-dez 2015. ilus
Article in Portuguese | LILACS | ID: biblio-831986

ABSTRACT

O presente artigo teve por objetivo conhecer o potencial de contaminação e disseminação de estetoscópios para infecções relacionadas a serviços de saúde à luz da literatura. A fonte de busca foi a Biblioteca Virtual de Saúde, nas bases de dados Medline, Lilacs e SciELO, realizado no mês de fevereiro de 2015, referente aos anos de 2004 a 2014. Utilizou-se os seguintes critérios de inclusão: teses e periódicos escritos em língua inglesa, espanhola e portuguesa e acessados em texto completo sobre o tema. Foram incluídos nessa revisão 14 artigos. A presença de contaminação e a possível disseminação de micro-organismos pelos estetoscópios foi descrita por todos os estudos analisados. Dessa forma, foi possível identificar que o tema merece maior atenção, já que os estetoscópios podem atuar como vetores para as infecções nosocomiais.


The contamination and dissemination capacity of infections by stethoscopes reported in the literature is analyzed. The Virtual Health Library and databases of Medline, Lilacs and SciELO were used during February 2015 for the 2004 ­ 2014 period. The following inclusion criteria were employed: theses and journals in English, Spanish and Portuguese accessed in full text online. Fourteen articles were included where contamination and possible dissemination of microorganisms by stethoscopes were described. The theme requires deeper attention since stethoscopes may be vectors of hospital infections.


Subject(s)
Cross Infection , Equipment Contamination , Health Personnel , Biological Contamination , Stethoscopes
9.
Bol. venez. infectol ; 25(2): 129-134, jul.-dic. 2014. tab, graf
Article in Spanish | LILACS | ID: lil-718901

ABSTRACT

Las infecciones adquiridas durante los cuidados de la salud (IACS), es un problema importante en Salud Pública. El presente trabajo tiene como objetivo determinar el porcentaje de estetoscopios contaminados con bacterias potencialmente productoras de IACS en las áreas de cuidados intensivos de pediatría y adultos. Se realizó un estudio clínico prospectivo transversal comparativo en la Unidades de Cuidados Intensivos pediátrico, neonatal y adulto del Hospital Central de San Cristóbal. Se tomaron cultivos a 37 instrumentos de los cuales 17 eran estetoscopios (52,9%). Nueve correspondieron a Pediatría y 8 al área de adulto. El tipo de personal que los utiliza representó un riego mayor de contaminación. De los estetoscopios con cultivos positivos el 85,6% venían de pediatría y el 36,4% de adultos; con una Odds ratio de 14.0. Conclusión: Los estetoscopios son una fuente de contaminación bacteriana siendo el área pediátrica un factor de riesgo elevado para su contaminación


Infections acquired during the (IACS) health care, is an important public health problem. This study aims to determine the percentage of stethoscopes contaminated with potentially producing bacteria of IACS in the areas of Pediatric and adult intensive care. A comparative study was conducted clinical prospective cross in the intensive care units paediatric, neonatal and adult of the Central Hospital of San Cristóbal. Cultures were taken at 37 instruments of which 17 (52,9%) were stethoscopes (9 corresponded to Pediatrics and 8 to the adult area). The type of personnel using it represented one major contamination risk. The stethoscopes with positive cultures the 85.6% came from Pediatrics and adults 36.4; with an Odds ratio of 14.0. Conclusion: Stethoscopes are a source of bacterial contamination being the Pediatric area a high risk of contamination of stethoscopes


Subject(s)
Female , Critical Care , Stethoscopes/virology , Hand Disinfection , Infections/virology , Pollution Indicators , Infectious Disease Medicine , Public Health
10.
Rev. MED ; 20(1): 90-100, ene.-jun. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-669292

ABSTRACT

La formación académica de estudiantes de medicina implica interacción con pacientes y superficies del entorno hospitalario, los microorganismos presentes allí pueden ser adquiridos y transmitidos con los riesgos consecuentes para la comunidad hospitalaria. El presente es un estudio descriptivo cuantitativo donde se analizan muestras provenientes de estudiantes de medicina (n= 155) en rotaciones de 3 semanas, tomando hisopados de nariz, boca, manos y fonendoscopio, gram y cultivo en agar sangre, incubación 24 horas a 37°C y 5% de CO2. Se hizo la identificación mediante gram y pruebas de biotipificación convencionales y susceptibilidad antibiótica según técnica de kirbybauer. Los hallazgos aquí presentados evidencian alta frecuencia de bacterias patógenas en las fuentes de aislamiento, siendo relevante la presencia del Staphylococcus aureus en un 41,7% y la resistencia a antibióticos tanto por gram positivos como por gram negativos; por tanto, es de considerar la implementación de estrategias que minimicen la circulación de estos microorganismos en el ambiente hospitalario. El objetivo de este estudio es establecer la frecuencia de los microorganismos aislados en estudiantes de una Facultad de Medicina.


The academic training of medical students involves interaction with patients, where microorganisms in contact with different surfaces can be acquired and transmitted with the consequent risk to the community hospital.This is a quantitative descriptive study on students of medicine (n = 155) with clinic rotations of 3 weeks, swabs were taking from the nose, mouth, hands and stethoscope, following by gram and blood agar cultures, incubation 24 hours at 37° C and 5% CO2, final Identification was performed by gram, biotyping tests and antibiotic susceptibility by kirbybauer technique.The findings presented here show high frequency of bacterial pathogens in source isolation, to be relevant the presence of Staphylococcus aureus in 41.7% and resistan cetoantibiotics both grampositive andgramnegative, therefore is to consider the implementation of strategies to minimize the movement of these microorganisms in the hospital environment.The objective of this study is to establish the frequency of microorganisms isolated from students at a medical school.


A formação acadêmica dos estudantes de medicina implica interação com pacientes e superfícies do entorno hospitalar, os microorganismos presentes ali podem ser adquiridos e transmitidos com os riscos consequentes para a comunidade hospitalar. O presente é um estudo descritivo quantitativo onde foram analisadas amostras provenientes de estudantes de medicina (n= 155) em rotações de 3 semanas, colhidas do nariz, da boca, das mãos e de estetoscópios, gram e cultivo em ágar sangue, incubação 24 horas a 37°C e 5% de CO2, foi feita a identificação mediante gram e testes de biotipificação convencionais e suscetibilidade antibiótica segundo técnica de kirbybauer. Os descobrimentos aqui apresentados evidenciam alta frequência de bactérias patógenas nas fontes de isolamento, sendo relevante a presença do Staphylococcus aureus em 41,7% e a resistência a antibióticos tanto por gram positivos como por gram negativos; portanto, é necessário considerar a implementação de estratégias que minimizem a circulação destes microorganismos no ambiente hospitalar. O objetivo deste estudo foi estabelecer a frequência dos microorganismos isolados em estudantes de uma Faculdade de Medicina.


Subject(s)
Humans , Young Adult , Stethoscopes , Students, Medical , Hygiene , Biological Contamination
11.
Rev. salud bosque ; 1(1): 17-24, 2011. tab, graf
Article in Spanish | LILACS | ID: lil-779444

ABSTRACT

Resultados: se encontró un 80% de los estetoscopios contaminados, con una mediana de colonización de 2.58 Unidades Formadoras de Colonias (UFC)/cm2 y un 100% de los teléfonos móviles contaminados con una mediana de 0.401 UFC/cm2. En estetoscopios se aislaron SAMR (n=3) y Enterobacterias resistentes a cefalosporinas de tercera generación (n=2). En teléfonos móviles se aislaron SAMR(n=1), Candida spp (n=1) y Enterobacterias (n=5). La encuesta permitió establecer una tendencia de hábitos de higiene inapropiados sobre el uso de los fómites. Conclusiones: el hallazgo de bacterias resistentes en estos fómites los convierte en fuentes potenciales de transmisión cruzada y de brotes de infección intrahospitalaria. Estos resultados deben orientar el desarrollo de protocolos para el uso racional de dispositivos médicos y tecnología portátil dentro de ambientes hospitalarios.


Results: 80% of the stethoscopes (n=40) were found contaminated with a median count of 2,58 CFU/cm2 meanwhile 100% of cellular phones where found contaminated with a median count of 0,401 CFU/cm2. MRSA (n=3) and third generation cephalosporin-resistant Enterobacteriaceae (n=2) were isolated from stethoscopes, whereas in cellular phones MRSA (n=1), Candida (n=1) and third generation cephalosporin-sensitive Enterobacteriaceae (n=5) where found. Survey results indicated a trend towards inappropriate hygiene habits with fomites; however no statistical correlation could be established between these habits and colonization. Conclusion: The finding of nosocomial pathogens in these fomites transforms them in potential sources of crosscontamination and hospital-acquired infections outbreaks. Present results must steer development of protocols for rational use of medical devices and portable technology gadgets within hospital controlled environments.


Subject(s)
Humans , Male , Female , Enterobacteriaceae , Cross Infection , Infection Control , Staphylococcus aureus , Intensive Care Units, Neonatal
SELECTION OF CITATIONS
SEARCH DETAIL