1.
Rev. chil. radiol ; 22(2): 61-69, jun. 2016. ilus, tab
Article in Spanish | LILACS | ID: lil-796826

ABSTRACT

Abstract. In order to have a more accurate estimation of the dose delivered for computed tomography (CT) studies, and given that the current dose estimates do not include the size of the patient, a retrospective study was conducted on a sample of 388 patients from the radiology department of a general hospital, to make a better assessment of the dose delivered for CT scans of the chest, abdomen and pelvis in adult and paediatric patients. A comparison was made between the volume computed tomography dose index (CTDIvol) delivered by the scanner and CTDIvol value corrected by the incorporation of the effective patient diameter according to the report 204 of the American Association of Physicists in Medicine (AAPM). It was found that the values of CTDIvol vary in all cases when the patient size parameter is included, with this variation being greater as sizes go to extremes.


Resumen. Con el objetivo de tener una estimación de dosis más exacta entregada por los estudios de tomografía computarizada (TC) y dado que los estimadores de dosis actuales no incluyen el tamaño del paciente en la estimación, se realizó un estudio retrospectivo en una muestra de 388 pacientes de un servicio de radiología de un hospital general, para calcular las dosis entregadas en exámenes de TC de tórax, abdomen y pelvis en pacientes adultos y pediátricos. Se elaboró y realizó una comparación entre el índice de dosis de TC (CTDI VOL) entregado por el equipo y el CTDI VOL corregido mediante la incorporación del parámetro del diámetro efectivo del paciente según el reporte 204 de la Asociación Americana de Físicos Médicos (AAPM). Se pudo comprobar que los valores de CTDI VOL varían en la totalidad de los casos al ingresar el parámetro de tamaño del paciente y que esta variación es mayor a medida que los tamaños se van a los extremos.


Subject(s)
Humans , Child , Adult , Radiation Dosage , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/standards , Retrospective Studies , Phantoms, Imaging
2.
Rev. chil. radiol ; 15(4): 197-200, 2009. ilus
Article in Spanish | LILACS | ID: lil-577469

ABSTRACT

We present the application of a numerical model to estimate the mean glandular dose for mammography. A General Electric mammography system, tube voltaje of 20-35 kV with increments of 1 kV, tube current of 10-250 mAs, anode/filter combinations molybdenum/molybdenum was used. Over a period of two months, data from 162 scans with craniocaudal and mediolateral oblique projections in both breasts were recorded. The thickness of the compressed breast ranged from 2.5 to 6.5 cm. The mean glandular dose for each craniocaudal projection ranged from 0.4 to 0.7 mGy for a thickness of 2.5 cm and 1.9 to 2.8 mGy for a thickness of 6.5 cm. All average values of mean glandular dose estimated by cranio-caudal projection were found to be below the international reference dose value of 3 mGy recommended by the American College of Radiology.


Presentamos la aplicación de un modelo numérico para estimar la dosis glandular promedio en mamografía. Hemos utilizado un mamógrafo General Electric, tensión del tubo: 20-35 kV con incrementos de 1 kV; carga del tubo: 10-250 mAs; combinación ánodo-filtro de Molibdeno-Molibdeno. Durante dos meses datos de 162 exploraciones con proyecciones cráneo-caudal y medio lateral oblicua en ambas mamas. El espesor de mama comprimida se encuentra en el rango de 2,5 a 6,5 cm. Los rangos de dosis glandular promedio, por cada proyección cráneo-caudal, se encuentran de 0,4 a 0,7 mGy para un espesor de 2,5 cm y de 1,9 a 2,8 mGy para un espesor de 6,5 cm. Los valores medios de dosis glandular promedio estimados por proyección cráneo-caudal, en su totalidad resultan por debajo del valor de referencia dado por el Colegio Americano de Radiología (3 mGy).


Subject(s)
Humans , Female , Adult , Middle Aged , Algorithms , Quality Control , Radiation Dosage , Mammography/methods , Age Factors , Breast/radiation effects , Dose-Response Relationship, Drug , Reference Values