1.
Journal of Environment and Health ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-545221

ABSTRACT

Objective To explore the effects of temperature and relative humidity on radon exhalation rate of glazed tile in the hermetic environment. Methods Ordinary glazed tile was used as experimental object to detect radon concentration with Model 1027 continuous radon monitor in a 0.25 m3 simulation chamber at different temperature and humidity,and then calculated the radon exhalation rate. Results In reasonable range,a cubic correlation between radon exhalation rate(ER) and relative humidity(RH) expressed as ER=0.000 2RH3-0.040 2RH2+2.623 9RH-32.303(R2=0.986 6)was found; a cubic function relationship between radon exhalation rate(ER) and temperature(t) expressed as ER=-0.022 5t3+2.016 5t2-58.748t+565.05(R2=0.969 8)was also observed. Conclusion Environmental temperature and relative humidity have great effects on radon exhalation rate of glazed tile.