Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Hip & Pelvis ; : 187-193, 2017.
Article in English | WPRIM | ID: wpr-140095

ABSTRACT

PURPOSE: The purpose of this study is to present the effective design of N-plasty of the iliotibial band and surgical results of its use as a treatment for refractory external snapping hip. MATERIALS AND METHODS: We evaluated 17 patients (24 cases) with external snapping hip who underwent N-plasty between October 2013 and May 2016 and who were followed up for at least 12 months. All patients were male and the mean age was 20.8 years. The mean duration of symptoms prior to surgical intervention was 28.5 months with an average follow up of 24.5 months. Surgery was defined as being successful when patients could carry out their daily activities and exercise without a clicking sensation or pain 6 months after surgery until their last follow-up. Failure was defined when either a clicking sensation or pain was present. The visual analog scale (VAS) and modified Harris hip score (mHHS) were measured and compared preoperatively and at last follow-up. RESULTS: All patients had complete resolution of pain and snapping. The VAS decreased from 6.77 preoperatively to 0.09 postoperatively and mHHS improved from 69.5 to 97.8 after surgery. CONCLUSION: Modified designed N-plasty is considered to be an excellent treatment method facilitating operation reproducibility with maximum elongation effect of the iliotibial band.


Subject(s)
Humans , Male , Follow-Up Studies , Hip , Methods , Sensation , Visual Analog Scale
2.
Hip & Pelvis ; : 187-193, 2017.
Article in English | WPRIM | ID: wpr-140094

ABSTRACT

PURPOSE: The purpose of this study is to present the effective design of N-plasty of the iliotibial band and surgical results of its use as a treatment for refractory external snapping hip. MATERIALS AND METHODS: We evaluated 17 patients (24 cases) with external snapping hip who underwent N-plasty between October 2013 and May 2016 and who were followed up for at least 12 months. All patients were male and the mean age was 20.8 years. The mean duration of symptoms prior to surgical intervention was 28.5 months with an average follow up of 24.5 months. Surgery was defined as being successful when patients could carry out their daily activities and exercise without a clicking sensation or pain 6 months after surgery until their last follow-up. Failure was defined when either a clicking sensation or pain was present. The visual analog scale (VAS) and modified Harris hip score (mHHS) were measured and compared preoperatively and at last follow-up. RESULTS: All patients had complete resolution of pain and snapping. The VAS decreased from 6.77 preoperatively to 0.09 postoperatively and mHHS improved from 69.5 to 97.8 after surgery. CONCLUSION: Modified designed N-plasty is considered to be an excellent treatment method facilitating operation reproducibility with maximum elongation effect of the iliotibial band.


Subject(s)
Humans , Male , Follow-Up Studies , Hip , Methods , Sensation , Visual Analog Scale
3.
Hip & Pelvis ; : 173-177, 2014.
Article in English | WPRIM | ID: wpr-108144

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the clinical outcome of arthroscopic treatment for recalcitrant external snapping hip. MATERIALS AND METHODS: Between September 2011 and June 2013, we evaluated 7 patients (10 cases) with snapping hip who were refractory to conservative treatments for at least 3 months. Two patients (4 cases) were impossible to adduct both knees in 90degreesof hip flexion. Surgery was done in lateral decubitus position, under spinal anesthesia. We made 2 arthroscopic portals to operate the patients, and used cross-cutting with flap resection technique to treat the lesion. We performed additional gluteal sling release in those 2 patients (4 cases) with adduction difficulty. Average follow-up length was 19 months (range, 12-33 months). Clinical improvement was evaluated with visual analog scale (VAS), modified Harris hip score (mHHS), and also investigated for presence of limping or other complications as well. RESULTS: The VAS decreased from 6.8 (range, 6-9) preoperatively to 0.2 (range, 0-2) postoperatively, and the mHHS improved from 68.2 to 94.8 after surgery. None of the patients complained of post-operative wound problem or surgical complications. CONCLUSION: The clinical outcome of arthroscopic treatment for recalcitrant external snapping hip was encouraging and all patients were also satisfied with the cosmetic results.


Subject(s)
Humans , Anesthesia, Spinal , Arthroscopy , Follow-Up Studies , Hip , Knee , Visual Analog Scale , Wounds and Injuries
SELECTION OF CITATIONS
SEARCH DETAIL