China Medical Equipment ; (12): 11-14,15, 2017.
Article in Chinese | WPRIM | ID: wpr-606387

ABSTRACT

Objective:To establish the X-ray standard was used to calibrate Hp(3) dosimeter in order to satisfy the requirement of eye-lens dose equivalents for the radiological occupational staff.Methods:The conventional values (Hp(3)) on the reference point of the narrow beams of X-ray fields were obtained by means of the product of air kerma (Kair) and the conversion coefficients (hp(3,ɑ)) recommended by ICRP116 recommendation. And these researches can be used by standard ionization chamber dosimeter. Finally, provided the conventional true value Hp(3) at calibrate point.Results:The standards and calibration program of calibrations eye-lens dose equivalent dosimeter were established under the X-ray radiation field. The detection error between slab phantom recommended by ISO and head phantom recommended by the 116th publication of ICRP was lower when the TLD was used to detect result.Conclusions:The standards for calibration Hp(3) dosimeters can satisfy the requirement of calibration for radiological occupational staff. It also provides theoretical foundation for detection data that assessed Hp(3) dosimeters and then improves trace ability and reliability of detection data of Hp(3) in national radiation supervision and inspection network.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 395-397, 2011.
Article in Chinese | WPRIM | ID: wpr-424203

ABSTRACT

Objective To assess the level of radiation exposures of operators in three typical types of interventional fluoroscopic procedures.Methods Alderson Radiation Therapy (ART) phantom was used to stimulate the practices of diagnosis and therapy using TLDs for dose measurement.The radiation exposures of eye lens, neck, and breast were measured when the lead shielding of machine was on/off and the equivalent dose and effective dose to the eye lens were estimated.Results Radiation exposure of head was obviously reduced by 85% -90% when the lead shielding was on.The doses in different procedures were different.In cerebral angiography the dose equivalent of eye len was the highest in the three procedures.The annual effective dose for the operators was smaller in peripheral vascular interventions than that in cardiovascular interventional therapy and that in cerebral angiography.Conclusions The operators involved in intervention will receive an annual effective dose of less than 20 mSv as recommended by the ICRP under the protection conditions provided by the current study, except for eye lens.Attention should be paid to the protection of the eyes of operators.

SELECTION OF CITATIONS
SEARCH DETAIL