Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta Anatomica Sinica ; (6): 420-424, 2020.
Article in Chinese | WPRIM | ID: wpr-1015562

ABSTRACT

[Abstract] Objective To investigate the optimal screw configuration for internal fixation of femoral neck fractures based on anatomic analysis on radiologic imaging. Methods From January to February 2017, thirty proximal femurs of 15 nonnal adults from Picture Archiving and Communication Systems (PACS) of Paople' s Hospibal of Anji were constructed by CT. 8 males and 7 females with a mean age of (43±8. 5) years (ranging from 28 to 63 years) .The medial femoral neck sections (FNS) were projected on the lateral femoral trochanteric wall. The simulated three screw configurations in the projection of FNS include: two inverted equilateral triangles symmetrized to the axis of the FNS (IET-FNS group) or the coronal axis of the proximal femur (IET-PF group) and an obtuse triangle (OT group).The distance between the screws, the distance between the centre of the FNS and the screws, and the area ratio of the triangle/FNS were calculated. Results The projection of the FNS on the lateral femoral trochanteric wall was displayed as a rotating forward ellipse. Measurements of distance between screws

2.
Acta Anatomica Sinica ; (6): 694-697, 2014.
Article in Chinese | WPRIM | ID: wpr-474181

ABSTRACT

Objective To investigate the feasibility of measuring femoral neck torsion angle and anteversion angle by laser projection method .Methods The femoral neck torsion angle and anteversion were observed and described .An angle measuring device was designed and produced .With the device , the femoral torsion angle and anteversion angle were measured by laser projection method two times .Statistical analysis was performed on the measured value , and sides difference .Results The differences between femoral neck torsion angle and anteversion angle were observed .There was no significant difference ( P >0.05, power =100%) between the two measurements by laser projection method . Measurements of the femoral anteversion were 13.58 °±6.55 °on the left side , and 12.15 °±5.83 °on the right side . Measurements of the femoral neck torsion angle were 18.50 °±7.38 °on the left and 19.08 °±8.59 °on the right .There was no significant difference between left and right side ( P >0.05 ) .Conclusion The laser projection method is the effective method in measuring femoral neck torsion angle and anteversion angle , and has excellent repeatability .

SELECTION OF CITATIONS
SEARCH DETAIL