Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 280-286, 2024.
Article in Chinese | WPRIM | ID: wpr-1013089

ABSTRACT

Objective@#Based on 3D printing technology, explore the precision of a perforator vessel location guide plate for fibular musculocutaneous flaps before the transplantation of fibular osteocutaneous flaps and evaluate its application effects.@*Methods@#This study was reviewed and approved by the ethics committee, and informed consent was obtained from the patients. From May 2019 to October 2022, 14 patients with jaw defects who needed to undergo fibular perforator flap transplantation at the First Affiliated Hospital of Xinjiang Medical University were selected. For the seven patients in the guide plate group, CTA was combined with Mimics software to reconstruct both lower limbs, and the perforator vessel positioning guide for locating perforator vessels was designed; the two ends of the guide plate were designed as fixed ends, with the upper end fixed to the knee joint and the lower end fixed to the ankle joint, and the guide plate was fabricated by a 3D printer. For the seven patients in the control group, a conventional handheld Doppler probe was used for perforator vessel location. The average operation time, bleeding volume, recovery time, deviation of perforator vessel location, postoperative flap-related complications, postoperative donor site shape satisfaction, and lower extremity functional scale (LEFS) score were recorded. SPSS 25.0 software was used for statistical analysis.@*Results@#The average operation time, bleeding volume, recovery time, deviation of perforator vessel location and postoperative donor site shape satisfaction were significantly better in the guide plate group than in the control group (P<0.05); moreover, the differences in postoperative flap-related complications and LEFS scores were not statistically significant (P>0.05).@*Conclusion@#Based on 3D printing technology, fibular musculocutaneous flap perforator vessels can be more accurately located using a guide plate and the knee and ankle as fixed points, and this method can effectively stabilize the guide position, prevent soft tissue offset, and improve positioning accuracy and thus deserves to be generalized.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 839-842, 2019.
Article in Chinese | WPRIM | ID: wpr-796385

ABSTRACT

Objective@#To report our clinical application of free fibular composite tissue flap with peroneus longus and brevis in the treatment of complicated extremity trauma.@*Methods@#From August 2014 to September 2017, 5 patients with complicated extremity trauma were treated using a free fibular composite tissue flap with peroneus longus and brevis at Department of Orthopaedics, The Sixth People's Hospital of Shanghai. They were 4 men and one woman, aged from 23 to 52 years (average, 35.1 years). All of them had tendon defects; one had a radius defect, one an ulnar defect and three a tibial defect. The length of bone defects ranged from 8 cm to 18 cm; the size of soft tissue defects ranged from 10 cm × 5 cm to 18 cm ×8 cm. A fibular composite tissue flap was designed according to the soft tissue condition and defect area to repair and fixate the bone defect after thorough debridement and cover the wound before functional reconstruction. Postoperatively, survival of the flap and functional recovery of the corresponding tendon at the recipient site, healing time of the tibia, and wound healing, ankle motion and complications at the donor site were all observed.@*Results@#The 5 patients were followed up for 18 to 38 months (average, 25.2 months). All flaps survived without any vascular crisis or infection. The union time for the fibular graft ranged from 4 to 16 months (average, 8.4 months). In the 3 patients with a tibial defect, the maximum angle of dorsal extension ranged from 0° to 10° and no foot drop was observed. Thumb and digital flexion was reconstructed in the patients with a forearm bone defect only to achieve opposition of index finger and thumb but we failed to make them have a fist. At the 5 flap donor sites, the wound was sutured by the second stage after vacuum suction and healed well; obvious scar formed in one of them. No obvious foot varus was observed at the donor site. The patients were satisfactory with their ankle joint motion. No refracture of the fibular graft occurred during follow-up.@*Conclusion@#A free fibular composite tissue flap with peroneus longus and brevis is a good choice for complicated extremity trauma.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 839-842, 2019.
Article in Chinese | WPRIM | ID: wpr-791273

ABSTRACT

Objective To report our clinical application of free fibular composite tissue flap with peroneus longus and brevis in the treatment of complicated extremity trauma.Methods From August 2014 to September 2017,5 patients with complicated extremity trauma were treated using a free fibular composite tissue flap with peroneus longus and brevis at Department of Orthopaedics,The Sixth People's Hospital of Shanghai.They were 4 men and one woman,aged from 23 to 52 years (average,35.1 years).All of them had tendon defects;one had a radius defect,one an ulnar defect and three a tibial defect.The length of bone defects ranged from 8 cm to 18 cm;the size of soft tissue defects ranged from 10 cm × 5 cm to 18 cm × 8 cm.A fibular composite tissue flap was designed according to the soft tissue condition and defect area to repair and fixate the bone defect after thorough debridement and cover the wound before functional reconstruction.Postoperatively,survival of the flap and functional recovery of the corresponding tendon at the recipient site,healing time of the tibia,and wound healing,ankle motion and complications at the donor site were all observed.Results The 5 patients were followed up for 18 to 38 months (average,25.2 months).All flaps survived without any vascular crisis or infection.The union time for the fibular graft ranged from 4 to 16 months (average,8.4 months).In the 3 patients with a tibial defect,the maximum angle of dorsal extension ranged from 0° to 10° and no foot drop was observed.Thumb and digital flexion was reconstructed in the patients with a forearm bone defect only to achieve opposition of index finger and thumb but we failed to make them have a fist.At the 5 flap donor sites,the wound was sutured by the second stage after vacuum suction and healed well;obvious scar formed in one of them.No obvious foot varus was observed at the donor site.The patients were satisfactory with their ankle joint motion.No refracture of the fibular graft occurred during follow-up.Conclusion A free fibular composite tissue flap with peroneus longus and brevis is a good choice for complicated extremity trauma.

4.
Journal of Practical Stomatology ; (6): 412-416, 2015.
Article in Chinese | WPRIM | ID: wpr-463574

ABSTRACT

Objective:To evaluate the clinical outcomes of 2 kinds of osteocutaneous flap in the treatment of mandibular osteoradione-crosis.Methods:35 cases with mandibular osteoradionecrosis were treated by partial mandibulectomy and bone graft according to de-fect size and patients'requirements.The defects in 7 patients were reconstructed with iliac osteocutaneous flap and 28 with fibular os-teocutaneous flap.All flaps and wounds were monitored regularly.Results:One flap with venin crisis was observed in the patients treated with iliac osteocutaneous flap,its skin island was failed but the bone graft was survived.In the fibular osteocutaneous flap group,3 flaps with vein crisis were observed.2 of them were failed and 1 was rescued after second surgery.The most common compli-cations were infection,delayed wound healing and scar.The appearance and function were all satisfied and limitation of mouth opening was improved after surgery.Conclusion:Both of fibular osteocutaneous flap and iliac osteocutaneous flap can be applied in the defect reconstruction of patients with mandibular osteoradionecrosis.Fibular osteocutaneous flap is a good choice for huge mandibular defect and iliac osteocutaneous flap seems more esthetical.

5.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-588886

ABSTRACT

Objective:To summarize the experience of reconstruction of mandibular defects with vascularized fibular osteocutaneous flap.Methods:Segmental mandibular resection and immediate reconstruction with vascularized fibular osteocutaneous flap were performed in 8 patients with tumor.The fibula flaps were cut into 2-4 segments and bent to the contour of the mandibles,and they were fixed precisely by the titanium plate.The skin flaps were used for reconstruction of soft tissue defects or as observation windows of the blood circulation.Results:In all 8 patients,transplanted vascularized fibular osteocutaneous flaps survived well,and restoration of mandibular contour and function was satisfactory. Conclusion:The fibular osteocutaneous flap can be cut into segments and shaped according to location and contour of mandibular defect.Vascularized fibular osteocutaneous flap may be an ideal selection for the reconstruction of mandibular defect.

SELECTION OF CITATIONS
SEARCH DETAIL