1.
Chinese Journal of Radiological Medicine and Protection ; (12): 456-460, 2014.
Article in Chinese | WPRIM | ID: wpr-453538

ABSTRACT

Objective To verify the reliability of dose parameters of radiotherapy under reference and non-reference conditions by using TLD.Methods Dose parameters were verified by using TLDs under reference and non-reference conditions,including the maximum dose in axel of 5 electron beams with energy of 9 MeV and the variations of dose by depth,source-skin distance,exposure field and 45° wedge for 10 photon beams with energy of 6 MV in 5 hospitals.Results The average relative deviation of 6 MV photon beam measured between TLDs and finger ionization chambers were 4.45%,within ± 7% as required by IAEA.The average relative deviation of 9 MeV electron beam measured between TLDs and plane parallel chambers were 2.45%,within ± 5% was required by IAEA.Conclusions Measuring dosimetric parameters by using TLDs under reference and non-reference conditions was reliable and feasible.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 451-455, 2014.
Article in Chinese | WPRIM | ID: wpr-453536

ABSTRACT

Objective To verify the methodology for auditing dosimetric parameters in reference and non-reference conditions with thermoluminescent dosimeters (TLDs).Methods Under reference and non-reference conditions,the established TLD methods were used to observe the absorbed dose variations with depth,SSD,field size and 45 wedges for 10 photon beams at 5 hospitals.Dosimetric parameters,including doses at Dmax points in axis,on 5 electron beams of 9 MeV were measured.The measurement results were compared between the TLDs and plane parallel ionization chambers.Results For 6 MV photon beams,the relative deviation of between finger ionization chamber method and TLD chips was in the range of-1.7% to 5.4% under on-axis non-reference conditions,and-6.3% to-0.6% under off-axis non-reference conditions,respectively,all within the range of ≤ ± 7% as required by the IAEA.The relative deviation between plane parallel chamber and TLD method was-2.3% to 3.7%,within ± 5% as required by the IAEA.Conclusions It is convenient and feasible to use TLD method for quality audits of dosimetric parameters in radiotherapy.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 461-465, 2014.
Article in Chinese | WPRIM | ID: wpr-453525

ABSTRACT

Objective To verify the reliability of TLD-based quality audit for radiotherapy dosimetry of medical electron accelerator in non-reference condition by monitoring the dose variations from electron beams with different field sizes and 45° wedge and the dose variations from photon beams with different field sizes and source-skin distance.Methods Both TLDs and finger ionization chambers were placed at a depth of 10 cm in water to measure the absorbed dose from photon beams,and also placed at the depth of maximum dose from electron beams under non-reference condition.TLDs were then mailed to National Institute for Radiological Protection,China CDC for further measurement.Results Among the 70 measuring points for photon beams,58 points showed the results with a relative error less than ± 7.0% (IAEA's acceptable deviation:± 7.0%) between TLDs and finger ionization chambers measurements,and the percentage of qualified point numbers was 82.8%.After corrected by P,value,62 points were qualified and the percentage was up to 88.6%.All of the measuring points for electron beams,with the total number of 24,presented a relative error within ± 5.0% (IAEA's acceptable deviation:± 5.0%) between TLDs and finger ioization cylindrical chambers measurements.Conclusions TLD-based quality audit is convenient for determining radiotherapy dosimetric parameters of electron beams in non-reference condition and can improve the accuracy of the measuring parameters in connection with finger chambers.For electron beams of 5 MeV < E0 < 10 MeV,the absorbed dose parameters measured by finger ionization chambers,combined with TLD audit,can help obtain the precise and reliable results.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 446-450, 2014.
Article in Chinese | WPRIM | ID: wpr-453523

ABSTRACT

Objective To verify the reliability of radiotherapy dosimetric parameters in reference and non-reference conditions using thermoluminescent dosimeters (TLDs).Methods Using the established TLD method,the dose variations with different radiation field sizes and 45 ° wedge plate were verified for 10 photon beams of 6 MV,together with dosimetric parameters at the point of maximum axial dose for 4 electron beams of 9 MeV under reference and non-reference conditions.Comparisons were made between TLD results and finger ionization chamber results.Results The average relative deviation,for 6 MV photon beams,between TLD results and finger ionization chamber measurements was 4.7%,within ± 7% as required by the IAEA.The average relative deviation,for 9 MeV electron beam,between TLD results and plane parallel ionization chamber measurements was 2.4 %,not beyond ± 5% permitted by IAEA.Conclusions Using TLD method to verify the radiotherapy dosimetric parameters in reference and non-reference conditions was reliable,simple and feasible.