Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. j. pharm. sci ; 51(3): 699-708, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766310

ABSTRACT

This article describes the application and performance of an inexpensive, simple and portable device for colorimetric quantitative determination of drugs in pharmaceutical preparations. The sensor is a light detector resistor (LDR) incorporated into a black PTFE cell and coupled to a low-cost multimeter (Ohmmeter). Quantitative studies were performed with captopril/p-chloranil/H2O2 and methyldopa/ammonium molybdate systems. Calibration curves were obtained by plotting the electrical resistance of the LDR against the concentration of the colored species in the ranges 1.84 × 10-4 to 1.29 × 10-3mol L-1 and 5.04 × 10-4 to 2.52 × 10-3 mol L-1 for captopril/p-chloranil/H2O2 and methyldopa/ammonium molybdate systems, respectively, exhibiting good coefficients of determination. Statistical analysis of the results obtained showed no significant difference between the proposed methodologies and the official reported methods, as evidenced by the t-test and variance ratio at a 95% confidence level. The results of this study demonstrate the applicability of the instrument for simple, accurate, precise, fast,in situ and low-cost colorimetric analysis of drugs in pharmaceutical products.


Este artigo descreve o desenvolvimento e a aplicação de um dispositivo portátil, simples e barato para a determinação colorimétrica quantitativa de fármacos em formulações farmacêuticas. O sensor é um resistor detector de luz (RDL) colocado numa célula de PTFE e acoplado a um multímetro de baixo custo. Os estudos quantitativos foram realizados utilizando captopril/p-cloranil/H2O2 e metildopa/molibdato de amônio como sistemas reacionais. As curvas de calibração foram obtidas através da representação gráfica da resistência elétrica do RDL contra a concentração dos complexos coloridos formados nas faixas de 1,84 × 10-4 e 1,29 × 10-3 mol L-1 e 5,04 × 10-4 e 2,52 × 10- 3 mol L-1 para captopril/p-cloranil/H2O2 e de metildopa/molibdato de amônio, respectivamente, com bons coeficientes de determinação. As análises estatísticas dos resultados obtidos mostraram que não houve diferença significativa entre os métodos propostos e os métodos oficiais como evidente a partir dos testes "t-Student" eF-Fisher, com nível de confiança de 95%. Os resultados deste estudo demonstram que o instrumento proposto neste trabalho é simples, de fácil operação, baixo custo e apresentou boa exatidão e boa precisão para o doseamento de fármacos em medicamentos.


Subject(s)
Pharmaceutical Preparations , Colorimetry/methods , Quality Control , Dosage
2.
Braz. j. pharm. sci ; 51(3): 653-661, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766319

ABSTRACT

The present work describes development and validation of a specific, sensitive, precise and stability-indicating high-performance liquid chromatographic method of analysis of atorvastatin calcium and celecoxib, both as a bulk drug and in niosomal formulation. The analysis has been performed by using Cosmosil-C18 column (4.6 mm´250 mm, 5 m) at 25 °C using acetonitrile: ammonium acetate buffer pH 5.0: methanol (50:25:25 v/v/v) as mobile phase. The detection was carried out at 277nm with a flow rate of 1.0mL/min. The retention times of Atorvastatin calcium and Celecoxib were 6.195 and 3.989min, respectively. The method was validated according to ICH guidelines, for specificity, precision, linearity, accuracy and robustness. Atorvastatin calcium and Celecoxib were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation was observed in oxidation and acid hydrolysis. The linearity for atorvastatin calcium and celecoxib were in the range of 100-500 µg/mL. The recovery study of atorvastatin and celecoxib were found to be in the range of 98.96 - 99.92% and 98.90-100%, respectively. The proposed method was validated and successfully applied to the estimation of Atorvastatin calcium and Celecoxib in combined in-house niosomal formulation.


O presente trabalho descreve o desenvolvimento e a validação de método de análise por cromatografia de alta eficiência específico, sensível, preciso e indicador de estabilidade de atorvastatina cálcica e celecoxibe, ambos como fármaco e como formulação niosômica. A análise foi realizada utilizando coluna Cosmosil-C18 (4,6 mm´250 mm, 5 m) a 25 °C, e acetonitrila: tampão acetato de amônio pH 5,0: metanol (50:25:25 v/v/v) como fase móvel. A detecção foi realizada a 277 nm, com fluxo de 1,0 mL/min. Os tempos de retenção de atorvastatina cálcica e de celecoxibe foram 6,195 e 3,989 min, respectivamente. O método foi validado de acordo com as regras da ICH para especificidade, precisão, exatidão e robustez. A atorvastatina cálcica e o celecoxibe foram submetidos a condições de estresse por hidrólise, oxidação, fotólise e degradação térmica. A degradação foi observada por oxidação e hidrólise ácida. Observou-se a linearidade da atorvastatina cálcica e do celecoxibe na faixa de 100-500 µg/mL. A recuperação da atorvastatina e do celecoxibe foi observada na faixa de 98,96-99,92% e 98,90-100%, respectivamente. O método proposto foi validado e aplicado com sucesso para a determinação de atorvastatina cálcica e celecoxibe em formulação niosômica caseira combinada.


Subject(s)
Validation Study , Chromatography, Reverse-Phase , Celecoxib/analysis , Atorvastatin/analysis , Chemistry, Pharmaceutical/methods , Chromatography, Liquid
3.
Braz. j. pharm. sci ; 50(3): 573-582, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728692

ABSTRACT

A simple, precise, sensitive, rapid, specific and economical spectrophotometric method was developed to determine methyldopa (MTD) content in bulk and pharmaceutical dosage formulations. The proposed method was based on the formation of a colored product from the nitrosation reaction of MTD with sodium nitrite in an acid medium. The resultant nitroso derivative species reacts further with sodium hydroxide and is converted it into a more stable compound. This yellow nitrosation product exhibited an absorption maximum at 430 nm. Beer's Law was obeyed in a concentration range of 6.37 to 82.81 μg mL-1 MTD with an excellent coefficient of determination (R 2 = 0.9998). No interference was observed from common excipients in formulations. The results showed the method to be simple, accurate and readily applied for the determination of MTD in pure form and in pharmaceutical preparations. The analytical results obtained for these products using the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure at a 95% confidence level.


Desenvolveu-se método espectrofotométrico simples, preciso, sensível, rápido, específico e econômico para a determinação do teor de metildopa (MTD) em matéria-prima e em formulações farmacêuticas. O método proposto baseia-se na formação de um produto colorido resultante da reação de nitrosação da MTD com nitrito de sódio em meio ácido. A espécie resultante (nitroso derivado) reage com hidróxido de sódio e é convertida a um composto mais estável de cor amarela. Este produto exibiu máximo de absorção a 430 nm. A lei de Beer foi obedecida na faixa de concentração de 6,37 a 82,81 μg mL-1 de MTD com excelente coeficiente de determinação (R 2 = 0,9998). Não se observou interferência de excipientes comumente encontrados em formulações farmacêuticas comerciais. Os resultados demonstraram que o método proposto apresenta simplicidade, excelentes precisão e exatidão e pode ser aplicado para a determinação de MTD na sua forma pura e em preparações farmacêuticas. Os resultados analíticos obtidos pelo método proposto estão de acordo com aqueles obtidos pelo método oficial descrito na Farmacopéia Brasileira, a um nível de confiança de 95%.


Subject(s)
Spectrophotometry/methods , Chemistry, Pharmaceutical/classification , Validation Study , Methyldopa/pharmacokinetics
4.
Braz. j. pharm. sci ; 50(4): 793-797, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741342

ABSTRACT

A reverse phase HPLC method is described for the determination of 6-mercaptopurine in bulk and tablets. Chromatography was carried on a C18 column using a mixture of acetonitrile and 0.05 mol/L sodium acetate buffer (10:90 v/v) as the mobile phase at a flow rate of 1 mL/min-1 with detection at 324 nm. The retention time of the drug was 3.25 min. The detector response was linear in the concentration of 0.01-5 μg/mL. The limit of detection and limit of quantification were 17 and 52 ng/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of mercaptopurine in bulk and tablets.


Descreve-se método de CLAE em fase reversa para a determinação de mercaptopurina a granel e em comprimidos. A cromatografia foi realizada em coluna C18, utilizando mistura de acetonitrila em tampão acetato de sódio 0,05 mol/L (10:90 v/v) como fase móvel, com fluxo de 1 mL/min e detecção a 324 nm. O tempo de retenção do fármaco foi de 3,25 min. A resposta do detector foi linear na concentração de 0,01-5 μg/mL. O limite de detecção e o limite de quantificação foram de 17e 52 ng/mL, respectivamente. O método foi validado pela determinação de sua sensibilidade, linearidade, acurácia e precisão. O método proposto é simples, econômico, rápido, acurado e preciso e, então, pode ser aplicado para controle de qualidade de rotina da mercaptopurina em batelada e em comprimidos.


Subject(s)
Chemistry, Pharmaceutical/classification , Chromatography, High Pressure Liquid/methods , Mercaptopurine/analysis , Quality Control , Chromatography, Reverse-Phase
SELECTION OF CITATIONS
SEARCH DETAIL