Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3527-3528,3529, 2014.
Article in Chinese | WPRIM | ID: wpr-600006

ABSTRACT

Objective To study the inconsistent relation of twin discordancy and the umbilical artery blood flow parameter of systolic/diastolic ratio.Methods 358 pregnant women were divided into the two groups of develop-mental nonidentity( n=67 ) and developmental identity ( n=291 ) according to the criterion that the differences of twins weight exceeded 25 percent.The umbilical artery blood flow parameter of systolic/diastolic ratio were observed. Meanwhile,the difference of weight and the umbilical artery blood flow parameter of systolic/diastolic ratio in the group of developmental nonidentity were observed.Results A significant difference of the umbilical artery blood flow parameter of systolic/diastolic ratio were found in the two groups of developmental nonidentity and developmental identity(7.81%vs 32.56%,P<0.05).There were 56 cases that twins weight exceeded from 25 to 35 percent,7 cases that twins weight exceeded from 35 to 45 percent and 4 cases that twins weight exceeded 45 percent in the group of developmental nonidentity which the umbilical artery blood flow parameter of systolic/diastolic ratio were (23.66 ± 5.78)%,(27.16 ±7.25)% and (33.16 ±4.23)% correspondingly with significant difference(F=23.21,P<0.05 ) .Conclusion The umbilical artery blood flow parameter of systolic/diastolic ratio has significance in diagnosis of twin discordancy.

2.
Chinese Journal of Ultrasonography ; (12): 228-230, 2012.
Article in Chinese | WPRIM | ID: wpr-425136

ABSTRACT

Objective To investigate the incidence and distribution of fetal discrepancy during the first trimester in dichorionic twins.Methods This was a prospective analysis of dichorionic twin pregnancies that underwent 11+0~ 13+6 week scan at a tertiary hospital from Sep 2008 to Oct 2010.Differences in crown-rump length (CRL),nuchal translucency ( NT),heart rate ( HR).deepest vertical pockets of amniotic fluid (DVP) for every pair of twin fetuses were calculated and expressed as absolute value and percentage of discordance.Results A total of 66 dichorionic twin pregnancies were included.The average CRL was significantly different between the larger fetus and the smaller one,which were (65.28 ±8.54)mm and (62.34 ± 8.49) mm respectively ( P < 0.001).The average NT was significantly different between two fetuses,which were ( 1.56 ± 0.35) mm and (1.28 ± 0.30) mm respectively. HR and DVP were also statistically different between two fetuses ( P <0.001).Conclusions The growth of two fetuses in normal dichorionic twins is not uniform during the first trimester.

SELECTION OF CITATIONS
SEARCH DETAIL