Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Information on Traditional Chinese Medicine ; (12): 87-90, 2017.
Article in Chinese | WPRIM | ID: wpr-507389

ABSTRACT

Objective To screen the presciption of Blumea gynecological lotion and investigate the inhibitory effect through inhibition rate test; To provide a basis for clinical application. Methods Consumption of Tween-80, SLES, hydrogenated castor oil (RH-40), and clarity of the solution were selected as the evaluation indexes to optimize the solubilizing agents. By using the filter paper method and the inhibition zone size as the evaluation index, the antimicrobial effect on Staphylococcus aureus. Escherichia coli and Candida albicans was studied to screen the best antibacterial agent from 2 g/L GM-BP, 2 mL/L PHMB, 2 mL/L A.SAP. With Blumeapowder dissolution percentage as the evaluation index, orthogonal test was used to screen additives in the lotion. Finally, the bacteriostasis effect and stability of the obtained lotion were investigated in vitro. Results The order of solubilizing effect was RH-40>SLES>Tween-80, and that of inhibition zone size was PHMB>A.SAP>GM-BP. The best prescription as follows:0.6 mg/mL Blumea powder, 0.04 g/mL SLES, 0.01 g/mL CAB-35, 10% propylene glycol. Bacteriostatic rates of Blumea gynecology lotion sample were more than 90%, and bacteriostatic rates remained more than 80% after 3 months. Conclusion The prescription of Blumea gynecology lotion is reasonable and practicable, with simple preparation process, available materials and good inhibitory effect and stability.

2.
China Pharmacist ; (12): 463-465, 2017.
Article in Chinese | WPRIM | ID: wpr-510006

ABSTRACT

Objective:To establish the HPLC fingerprint detection method for gynecological lotion. Methods:Wondasil C18 (250 mm × 4. 6 mm,5 μm)was selected as the analytical column. The mobile phase was composed of acetonitrile-0. 3% phosphric acid and 0. 3% diethylamine solution with gradient elution at a flow rate of 1. 0 ml·min-1 . The detection wavelength was set at 284 nm and the column temperature was 30℃. Ten batches of gynecological lotion were detected by the HPLC fingerprint and evaluated by Chromato-graphic Fingerprint Evaluation System of Chinese Medicine (2004 edition). Results: The separated peaks were clear and 15 common peaks were identified in the fingerprint of 10 batches of gynecological lotion. Conclusion: The HPLC fingerprint is with good repeat-ability and stability, which can provide evidence for the quality control of gynecological lotion.

SELECTION OF CITATIONS
SEARCH DETAIL