Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Korean Society of Spine Surgery ; : 187-191, 2007.
Article in Korean | WPRIM | ID: wpr-22582

ABSTRACT

A fracture of the posterior arch of the atlas is a rare complication of Halifax clamp fixation for atlantoaxial fusion. To the best of our knowledge, there is only one case reported reporting the English literature. Revision for this condition is challenging because of the difficulty in the surgical approach, internal fixation, and fusion. We report a case of bilateral fractures and nonunion of the posterior arch of the atlas and atlantoaxial nonunion after an atlantoaxial fusion procedure using Halifax clamp fixation, which resulted in persistent atlantoaxial instability and progressive myelopathy. Segmental screw fixation was performed using C1 lateral mass screws and C2 subarticular screws, along with intraarticular and extraarticular atlantoaxial inter-facet fusion.


Subject(s)
Spinal Cord Diseases
2.
Journal of Korean Neurosurgical Society ; : 926-933, 1999.
Article in Korean | WPRIM | ID: wpr-108592

ABSTRACT

OBJECTIVE: To determine the efficacy of various posterior fusion techniques in managing C1/2 instability. PATIENTS AND METHODS: Retrospective review of patients undergoing C1/2 posterior fusioin was undertaken with the aim of determining the long-term outcome of the selected procedures. Forty-two patients requiring posterior atlantoaxial fusion for various pathologies were treated with various instruments for internal spinal fixation. Forty-two patients underwent 45 procedures from 1990 to 1997, with a mean follow-up of 2.7 years(range 8 months-7 years) RESULTS: The most common disease processes were odontoid fracture(12 patients), os odontoideum(13), and rheumatoid instability(7). Nineteen interspinous wirings, 17 transarticular screw fixations, 9 halifax clamp applications were performed. Three of Halifax fixation and 2 of wiring failed in long term follow up. Among of them, bony fusion was failed in 3 patients which consequently required reoperation. All transarticular screw procedures resulted in successful fusions. CONCLUSIONS: Transarticular screw fixatioin has several potential advantages compare to other procedures as a technique for C1/2 posterior arthrodesis.


Subject(s)
Humans , Arthrodesis , Follow-Up Studies , Pathology , Reoperation , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL