Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Regional Anatomy and Operative Surgery ; (6): 458-460, 2017.
Article in Chinese | WPRIM | ID: wpr-619123

ABSTRACT

Objective To analyze the application effect of disposable surgery retractor which made of high polymer medical plastic.Methods From January 2016 to October 2016,80 patients of HCC who were treated with hepatectomy under general anesthesia in our hospital were randomly divided into the control group and the observation group according to different retractor during surgery.The control group used the traditional abdominal retractor during the sugery.Meanwhile,the observation group used disposable surgery retractor.The application effect between the two groups were compared.Results The satisfaction rate of surgical exposure and effect in surgeon of the observation group were higher than those of the control group.The wound pain time of patients in perioperative period and 1 month after surgery and chronic pain incidence in postoperative 6 months between the two groups were evaluated.It turned out that the difference in average pain score was statistically significant (P<0.05).Conclusion The disposable surgical retractor can improve the satisfaction rate of surgeons with better surgical exposure,and it can significantly reduce the damage of wound tissue,which effectively relieves the postoperative pain,shortens the time of postoperative pain,and reduces the incidence of chronic pain.

2.
International Journal of Biomedical Engineering ; (6): 247-250, 2009.
Article in Chinese | WPRIM | ID: wpr-393087

ABSTRACT

With the improvement of living standard, the requirement of artificial joint material is ever increasing. The development of meted artificial joint, high polymer artificial joint and ceramic-made artificial joint, which are widely used in joint replacement, are introduced. Advantages and disadvantages of these materials are discussed, as well as the required improvement to these three materials. Development on metal-to-metal hip resurfacing arthroplasty and its clinical application is introduced. Now that no material with good biocompatibility, good biomechanical compatibility, good biological aasociativity and satisfied life-span has yet been found, compound material artificial joint may be the focus of the research in future.

3.
Journal of Practical Stomatology ; (6)1996.
Article in Chinese | WPRIM | ID: wpr-544740

ABSTRACT

Objective:To measure the effect of disinfection on dimension stability of four high polymer impression materials which were separately immersed in 20 ml/L glutaraldehyde solution.Methods:Fifteen plaster replication models of four high polymer impression materials(Impregum Penta polyether, Express-Putty silicone, Silagum-Putty silicone, GC EXAFINE silicone) were made on the same metal master cast respectively. Vertical and horizontal dimensions between landmarks on the masters and plaster casts were measured with an optical microscope,one-way ANOVA was used to compare the measurements among the materials.Results:The difference between the masters and Casts in horizontal distances measured on Express-Putty silicone impression material produced models was longer than those on other high polymer impression materials produced ones after disinfection for 20 minutes and beyond clinical requirement. Compared with metal master cast, the difference became significant when these four silicone impression materials were disinfected for 40 minutes. Conclusion: Among the four kinds of impression materials, the Express-Putty silicone material is relatively the most accurate one after disinfection for 20 minutes.

SELECTION OF CITATIONS
SEARCH DETAIL