Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Journal of the Korean Shoulder and Elbow Society ; : 222-229, 2017.
Article in English | WPRIM | ID: wpr-770819

ABSTRACT

BACKGROUND: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. METHODS: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. RESULTS: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were 156.7°, 152.2°, 61.1°, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. CONCLUSIONS: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.


Subject(s)
Humans , California , Elbow , Follow-Up Studies , Humerus , Joint Capsule Release , Methods , Postoperative Complications , Shoulder , Surgeons , Suture Anchors , Sutures
2.
Clinics in Shoulder and Elbow ; : 222-229, 2017.
Article in English | WPRIM | ID: wpr-75356

ABSTRACT

BACKGROUND: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. METHODS: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. RESULTS: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were 156.7°, 152.2°, 61.1°, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. CONCLUSIONS: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.


Subject(s)
Humans , California , Elbow , Follow-Up Studies , Humerus , Joint Capsule Release , Methods , Postoperative Complications , Shoulder , Surgeons , Suture Anchors , Sutures
3.
Journal of the Korean Fracture Society ; : 55-59, 2011.
Article in Korean | WPRIM | ID: wpr-223235

ABSTRACT

PURPOSE: To compare the clinical and radiological outcomes of two surgical methods with tension band wire and Hook plate for unstable distal clavicle fractures. MATERIALS AND METHODS: Thirty patients with type II distal clavicle fractures were evaluated, who were operated with tension band wire (Group I) and Hook plate (Group II) fixation, from June 2005 to June 2009, and could be followed-up for more than 1 year after operation. The reduction and union were evaluated by the immediate post-operative and final radiographs. The functional outcome was evaluated by Kona's system and Constant-Murley scoring system. RESULTS: All 30 cases showed bony union. By Kona's functional evaluation, there were 16 cases with excellent and good results in Group I and 14 cases in Group II. The average Constant score was 88.3 (71~100) in Group I and 89.6 (72~100) in Group II, but there was no significant difference in both groups. As complications, there were 2 case with subacromial impingement, and 1 case showed subacromial erosion. There was no K-wire migration, deep infection and acromioclavicular joint arthritis. CONCLUSION: Tension band and Hook plate fixation technique gave satisfactory clinical and radiological results in patients with type II distal clavicle fractures. These results suggest that tension band wire and Hook plate fixation technique seems to be an effective method for type II distal clavicle fracture. But we think thal early removal of plate is necessary due to risks for subacromial impingement and erosion in Hook plate fixation.


Subject(s)
Humans , Acromioclavicular Joint , Clavicle
SELECTION OF CITATIONS
SEARCH DETAIL