ABSTRACT
@#Objective To prepare a national reference standard for the quantification of HEK293 cell DNA content,so as to provide a support for the determination of residual DNA in HEK293 cells in the industry.Methods HEK293 cell DNA prepared using Genomic-tip 500/G and genomic DNA purification reagents was used as source materials,and the purity and content were assessed using ultraviolet spectrophotometry and agarose gel electrophoresis.After dilution to approximately 100 ng/μL,the DNA was aliquoted at 160 μL/tube.Five different laboratories were organized for collaborative calibration by using ultraviolet spectrophotometry, and the stability and applicability were evaluated.Results The HEK293 cell DNA national reference standard exhibited A_(260)/A_(280) ratios between 1.8 and 2.0 and displayed a single band on electrophoresis,meeting the specified criteria.Collaborative calibration across five laboratories yielded 78 valid data points with an average content of 104.8 ng/μL,a relative standard deviation(RSD) of 4.2%.The 95% confidence interval for the mean was 103.8—105.8 ng/μL,and the 95% reference range for single measurements was 96.0—113.6 ng/μL.The average confidence limit rate was 1.0%,and the recommended storage condition was-80 ℃.Applicability studies were conducted using two different models of fluorescence quantitative PCR instruments.The reference standard exhibited good applicability within the range of 0.3—3 000 pg/reaction,with amplification efficiencies of 101% and 95%,and R~2 values of 0.999 2 and 0.999 5 for the standard curves,respectively.Conclusion This batch of HEK293 cell DNA national reference standard meets all required specifications and can be utilized as a national reference standard for fluorescence quantitative PCR detection,with a certified content of 104.8 ng/μL,assigned batch number 270039-202301.
ABSTRACT
@#Objective To prepare a national reference standard for the quantification of HEK293 cell DNA content,so as to provide a support for the determination of residual DNA in HEK293 cells in the industry.Methods HEK293 cell DNA prepared using Genomic-tip 500/G and genomic DNA purification reagents was used as source materials,and the purity and content were assessed using ultraviolet spectrophotometry and agarose gel electrophoresis.After dilution to approximately 100 ng/μL,the DNA was aliquoted at 160 μL/tube.Five different laboratories were organized for collaborative calibration by using ultraviolet spectrophotometry, and the stability and applicability were evaluated.Results The HEK293 cell DNA national reference standard exhibited A_(260)/A_(280) ratios between 1.8 and 2.0 and displayed a single band on electrophoresis,meeting the specified criteria.Collaborative calibration across five laboratories yielded 78 valid data points with an average content of 104.8 ng/μL,a relative standard deviation(RSD) of 4.2%.The 95% confidence interval for the mean was 103.8—105.8 ng/μL,and the 95% reference range for single measurements was 96.0—113.6 ng/μL.The average confidence limit rate was 1.0%,and the recommended storage condition was-80 ℃.Applicability studies were conducted using two different models of fluorescence quantitative PCR instruments.The reference standard exhibited good applicability within the range of 0.3—3 000 pg/reaction,with amplification efficiencies of 101% and 95%,and R~2 values of 0.999 2 and 0.999 5 for the standard curves,respectively.Conclusion This batch of HEK293 cell DNA national reference standard meets all required specifications and can be utilized as a national reference standard for fluorescence quantitative PCR detection,with a certified content of 104.8 ng/μL,assigned batch number 270039-202301.