Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
China Medical Equipment ; (12): 7-10,11, 2016.
Article in Chinese | WPRIM | ID: wpr-603555

ABSTRACT

Objective:To analyze the relationship between the concentration of glucose and the impedance of human blood, and study the relationship between human blood glucose detection and human blood impedance.Methods:The system adopts the AD5933 digital frequency synthesizer (DDS) in the excitation signal is produced, imposed on the impedance under test, the ADC acquisition signal and sent to the corresponding chip DFT digital processing module, measurement results through the I2C sent to the microcontroller, again by the single-chip microcomputer and PC computer communication, the computer shows that the impedance values. Results:The instrument can realize the resistor, capacitor, inductance, glucose solution impedance measuring rapidly and accurately, through experimental verify that resistive impedance deviation from the mean is 0.04, phase deviation from the mean is 0.15°.Conclusion:The glucose concentration of aqueous solution was linearly correlated with the impedance, the correlation coefficient greater than 0.99.

2.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-587331

ABSTRACT

The research procedure of dynamic data acquisition and analysis system for body temperature(the body temperature HOLTER) is introduced in this paper.Some aspects of software and hardware technology related to the body temperature HOLTER are discussed emphatically.The system presents a good result through the preliminary application to the clinical practice.

3.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-583359

ABSTRACT

The basic principle,characters and applications of I 2 C bus protocol are introduced in this paper.Its application to implantable e lectrical stimulator is also described based on MAX5630,a DAC chip produced by M AXIM Corporation.

4.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-590887

ABSTRACT

The principle and characteristics of I2C BUS are introduced as well as its application in multi physiological parameters measurement system.The hardware and software design of I2C BUS of multi physiological parameters measurement system are discussed.The system achieves the purpose of the design and the technology of I2C BUS meets the requirement in multi physiological parameters measurement system,including the acquisition of low frequency physiological parameters.I2C BUS predigests the design of hardware and software,thus reducing the cost of system.[Chinese Medical Equipment Journal,2008,29(2):91-93]

5.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-584584

ABSTRACT

The control system of radiating therapeutic instrument, powerful and reliable, is designed with the new chips of P89LPC669 and MAX669. Its hardware organization, system function and software framework are introduced in this paper.