Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 205
Filter
1.
Radiol. bras ; 56(3): 150-156, May-June 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1449031

ABSTRACT

Abstract Vacuum-assisted excision of breast lesions has come to be widely used in clinical practice. Increased acceptance and availability of the procedure, together with the use of larger needles, has allowed the removal of a greater amount of sample, substantially reducing the surgical upgrade rate and thus increasing the reliability of the results of the procedure. These characteristics result in the potential for surgical de-escalation in selected cases and gain strength in a scenario in which the aim is to reduce costs, as well as the rates of underestimation and overtreatment, without compromising the quality of patient care. The objective of this article is to review the technical parameters and current clinical indications for performing vacuum-assisted excision of breast lesions.


Resumo A excisão assistida a vácuo de lesões mamárias tem sido cada vez mais utilizada na prática clínica. A sua maior aceitação e disponibilidade, em associação ao uso de agulhas mais calibrosas, permitiu a retirada de quantidade maior de amostra, reduzindo substancialmente a taxa de subestimação diagnóstica e aumentando, assim, a confiabilidade final dos resultados do procedimento. Essas características resultam em potencial descalonamento cirúrgico, em casos selecionados, e ganham força em um cenário em que se visa a redução de custos, taxa de subestimação e tratamento excessivo, porém, sem comprometer a qualidade no cuidado com o paciente. O objetivo deste trabalho é revisar os parâmetros técnicos e as indicações clínicas atuais para realização de excisão assistida a vácuo em lesões mamárias.

2.
Philippine Journal of Obstetrics and Gynecology ; : 320-324, 2023.
Article in English | WPRIM | ID: wpr-1003749

ABSTRACT

@#Performing external beam radiotherapy alone without chemotherapy or brachytherapy for locally advanced cervical cancer with multiple lymph node metastases is challenging. The purpose of this case report is to present the efficacy of high‑dose adaptive extended‑field intensity‑modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB) in treating locally advanced cervical cancer with multiple lymph node metastases. A 67‑year‑old woman with locally advanced squamous cell carcinoma of the uterine cervix was treated by external beam radiotherapy alone due to the refusal of chemotherapy and intracavitary brachytherapy. In order to maximize the efficacy of treatment, extended‑field radiotherapy that includes the paraaortic lymph nodes as well as an adaptive IMRT‑SIB plan, was applied. The treatment was successful, resulting in complete tumor disappearance without severe adverse events. In conclusion, high‑dose adaptive IMRT‑SIB may be an alternative treatment option for locally advanced cervical cancer with multiple lymph node metastases.


Subject(s)
Radiation Dosage , Uterine Cervical Neoplasms
3.
Cancer Research and Clinic ; (6): 419-423, 2023.
Article in Chinese | WPRIM | ID: wpr-996250

ABSTRACT

Objective:To explore the efficacy and adverse reactions of image-guided hypofractionated intensity-modulated radiotherapy (Ig-HypoRT) conbined with contralateral esophageal protection in treatment of patients with unresectable stage Ⅲ non-small cell lung cancer (NSCLC).Methods:The clinical data of 45 patients with unresectable stage Ⅲ NSCLC who were admitted to Xuzhou Cancer Hospital from January 2016 to January 2019 were retrospectively analyzed. Patients received induction chemotherapy with a platinum-based dual-drug combination regimen, followed by Ig-HypoRT with a total dose of tumor of 60-63 Gy/12- 18 times at 3.5-5.0 Gy/time. Contralateral esophagus was delineated as an organ at risk during radiotherapy, limiting V 45 Gy≤1.8 cc and V 55 Gy ≤0.4 cc. Patients' efficacy, survival and the occurrence of adverse reactions were observed. Results:Among 45 patients, there were 9 cases of complete remission, 31 cases of partial remission, 4 cases of stable disease and 1 case of disease progression, and the effective rate was 88.8% (40/45). The median follow-up time was 34 months, 45 patients had a median overall survival (OS) time of 25.0 months (95% CI 21.7-28.8 months), with 1-, 2-, and 3-year OS rates of 78.9%, 56.8% and 47.7%, respectively; the median progression-free survival (PFS) time was 18.5 months (95% CI 15.0-22.0 months), with 1-, 2- and 3-year PFS rates of 59.8%, 32.6% and 18.6%, respectively. The 3-year local recurrence rate was 9% (4/45). The incidence of grade 1-2 radioactive esophagitis was 80% (36/45); the incidence of grade 1-2 chest pain was 20% (9/45). The incidence of grade 3-4 adverse reactions were 13% (6/45), including 7% (3/45) of grade 3 pulmonary atelectasis, 4% (2/45) of grade 3 radioactive pneumonia, and 2% (1/45) of grade 4 hemoptysis. Conclusions:Ig-HypoRT combined with contralateral esophageal protection for unresectable stage Ⅲ NSCLC can improve survival rate and reduce esophageal adverse reactions of patients.

4.
Cancer Research and Clinic ; (6): 271-277, 2023.
Article in Chinese | WPRIM | ID: wpr-996225

ABSTRACT

Objective:To evaluate the effect of image-guided with cone-beam computed tomography (CBCT) based on volumetric modulated arc therapy (VMAT)-flattening filter free (FFF) on the setup errors of stereotactic body radiotherapy (SBRT) in patients with spinal metastatic tumors.Methods:The clinical data of 15 patients with spinal metastatic tumors who underwent SBRT in Jilin Cancer Hospital from August 2020 to January 2022 were retrospectively analyzed. The radiotherapy dose of bone metastasis was 32 Gy per 4 times and CBCT scanning was performed before and after radiotherapy. Every patient received radiotherapy 4 times; all 15 patients underwent SBRT 60 times in total and 120 CBCT volume images were finally obtained and analyzed. The systematic error (Σ) and random error (σ) were calculated at different correction threshold levels. The translational setup error and rotational setup error at the left-right (X axis), head-foot (Y axis) and front-back (Z axis) directions before and after radiotherapy were compared, which were expressed as Σ ± σ.Results:The pre-SBRT and post-SBRT translational setup errors were (0.14±0.27) cm and (0.07±0.19) cm, respectively ( P<0.001) in the X direction, (-0.05±0.33) cm and (0.00±0.19) cm, respectively ( P = 0.001) in the Y direction, (-0.13±0.19) cm and (-0.02±0.14) cm, respectively ( P = 0.012) in the Z direction. The pre-SBRT and post-SBRT rotational setup errors were (-0.31±0.76)° and (-0.09±0.34)°, respectively ( P < 0.001) in the X direction, (-0.13±0.88)° and (-0.07±0.36) °, respectively ( P < 0.001) in the Y direction, (0.10±0.51)° and (0.16±0.38)°, respectively ( P < 0.001) in the Z direction. Conclusions:CBCT correction could reduce Σ and σof the translational setup and rotational setup, increase the accuracy of SBRT based on VMAT-FFF for patients with spinal metastatic tumors.

5.
Cancer Research and Clinic ; (6): 23-28, 2023.
Article in Chinese | WPRIM | ID: wpr-996181

ABSTRACT

Objective:To investigate the differences between the mental clips placed intraoperatively and the tumor bed's target volume delineation of seroma based on CT scanning during radiotherapy for breast cancer patients who received breast-conserving surgery in the persuit of a better solution to determine the tumor bed position.Methods:The clinical data of 13 patients with early breast cancer who received postoperative radiotherapy after breast-conserving surgery at Beijing Shijingshan Hospital and Beijing Shijitan Hospital of Capital Medical University from December 2020 to January 2022 were retrospectively analyzed. They all had surgical clips implanted during the surgery. The following methods were used to delineate the target volume of tumor bed, including gross target volume delineation of tumor bed based on the mental clips (GTVtb-Clip), the tumor bed's gross target volume delineation of seroma based on CT scanning (GTVtb-Seroma), and the combination of both (GTVtb-C+S). The volume, diameter on three coordinate axis, neutral point displacement and conformability of these delineation methods were compared.Results:The volume of GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S was (25±10) cm 3, (38±17) cm 3, (49±20) cm 3, and the differences were statistically significant (all P<0.05). The diameter on X axis was (4.7±1.2) cm, (5.3±1.4) cm, (5.7±1.6) cm, respectively in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S; the diameter on Y axis was (4.6±1.7) cm, (5.0±1.6) cm, (5.7±1.7) cm, respectively in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S; the diameter on Z axis was (4.4±1.5) cm, (5.2±1.4) cm, (5.6±1.4) cm in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S. The differences in the diameter of GTVtb-Clip and GTVtb-C+S on X,Y, Z axis were statistically significant (all P<0.05); the differences in the diameter of GTVtb-Seroma and GTVtb-C+S on X, Z axis were statistically significant (all P<0.05); the difference in the diameter of GTVtb-Clip and GTVtb-Seroma on X axis was statistically significant ( P<0.05) .Neutral point displacement was (5.8±1.6) cm, (5.5±1.9) cm, (6.0±1.7) cm, respectively of GTVtb-Clip, GTVtb-Seroma, GTVtb-C+S, and the difference was not statistically significant ( P>0.05). Conformability of GTVtb-Clip and GTVtb-Seroma, GTVtb-Clip and GTVtb-C+S, GTVtb-Seroma and GTVtb-C+S was 0.412±0.112, 0.525±0.095, 0.774±0.112,respectively, and the differences were statistically significant (all P<0.05). Conclusions:During radiotherapy after breast-conserving surgery for breast cancer, compared with the single method, the combination of GTVtb-Clip and GTVtb-Seroma can better cover the real tumor bed, thus reducing the omission of tumor bed and recurrence rate. CT position should better take place at 4 to 8 weeks for patients receiving radiotherapy after breast-conserving surgery, and target volume of tumor bed will be delineated based on the postoperative changes of both mental clips and seroma.

6.
Chinese Journal of Radiation Oncology ; (6): 464-469, 2023.
Article in Chinese | WPRIM | ID: wpr-993215

ABSTRACT

Magnetic resonance-guided radiotherapy (MRgRT) not only offers real time magnetic resonance (MR) imags with high-resolution and good soft tissue contrast to guide the delineation of the target volume during simulation and daily radiotherapy, but also reveals the position and shape changes of the target volumes and organs at risk (OAR) during treatment dynamically, which provides the evidence for the individual-adptive planning revision. Thus, MRgRT has the potential to dramatically impact cancer research and treatment. And this treatment mode is theoretically more suitable for the disease with obvious tissue deformation, such as breast. In this review, application of MR scanner with a linear accelerator (MR-linac) in radiotherapy workflows for breast cancer patients was summarized, and its implications and opportunities on breast cancer irradiation were highlighted.

7.
Chinese Journal of Radiological Medicine and Protection ; (12): 36-41, 2023.
Article in Chinese | WPRIM | ID: wpr-993048

ABSTRACT

Objective:To preliminarily investigate the effects of tumor treating field (TTF) arrays on the positioning accuracy of radiotherapy setup in the treatment of glioblastoma.Methods:The kilovolt cone-beam CT (CBCT) and an X-ray volumetric imaging (XVI) system were used to verify the radiotherapy setup of 29 patients treated with conventional radiotherapy and 12 patients treated with TTF concurrent radiotherapy, respectively. The errors of radiotherapy position isocenter and treatment plan isocenter were evaluated in six directions, namely lateral (Lat), head pin (Lng), dorsoventral (Vrt), roll, pitch, and rotation (Rtn). Then, the plan isocenter was redetermined according to the setup error data. Moreover, the dose distribution was recalculated without changing the radiation field parameters. Finally, the V40, Dmean, D98% and D2% of both PTV and CTV and the Dmean, D20 cm 3, and D30 cm 3 of scalp tissue were evaluated. Results:When patients were treated with TTF concurrent radiotherapy wearing TTF arrays, the setup errors increased by 2 mm and 1.3 mm on average (maximum: 3.5 mm and 2.7 mm) toward the foot and dorsal directions, respectively. In addition, the setup errors in both Roll and Rtn directions increased by about 1.1° toward one side. The V40 and D98% of PTV decreased by up to 4.78% and 6%, respectively. The Dmean, D20 cm 3, and D30 cm 3 to scalp tissue increased by up to 2.6%, 3.2%, and 3.5%, respectively. The errors of other dose parameters for both CTV and PTV were within 2%. Conclusions:TTF arrays have significant effects on the setup errors of patients in the Lng and Vrt directions and increase the setup difficulty in the Roll and Rtn directions, while there is no significant error in the Lat and Pitch directions. Moreover, too large setup errors can significantly reduce the dose to PTV.

8.
Chinese Journal of Practical Nursing ; (36): 1027-1030, 2023.
Article in Chinese | WPRIM | ID: wpr-990290

ABSTRACT

Objective:To report the first aid and nursing care of a case of intracranial air embolism after CT-guided percutaneous lung biopsy.Methods:The 1 case with intracranial air embolism after CT-guided percutaneous lung biopsy was given a series of treatment and nursing measures, including on-site first aid, hyperbaric oxygen therapy, sequential oxygen therapy and phased rehabilitation in Zhujiang Hospital, Southern Medical University in November 2022.Results:By giving timely and effective treatment and nursing measures, the patient recovered well and was discharged after 12 days of hospitalization.Conclusions:Intracranial air embolism is a critical disease, which should be mainly prevented, recognized, diagnosed and treated with hyperbaric oxygen as soon as possible.

9.
Chinese Journal of Medical Instrumentation ; (6): 608-611, 2023.
Article in Chinese | WPRIM | ID: wpr-1010248

ABSTRACT

This article briefly describes the imaging performance standards of the kilovolt X-ray image guidance system used in radiotherapy, analyzes the main aspects that should be considered in the image quality of X-IGRT system, and focuses on parameters that should be considered in the imaging performance evaluation criteria of the CBCT X-IGRT. The purpose is to sort out the imaging performance evaluation standards of kilovolt X-IGRT system, clarify the image quality requirements of X-IGRT equipment, and reach a consensus when evaluating the imaging performance of X-IGRT system.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Cone-Beam Computed Tomography/methods , Spiral Cone-Beam Computed Tomography , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Image-Guided/methods
10.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 131-137, 2023.
Article in English | WPRIM | ID: wpr-961839

ABSTRACT

ObjectiveThis study aimed to analyze the difference in setup error before and after correction of systematic error. To determine the most appropriate image-guided strategy during HT treatment, we use different scanning ranges and image-guidance frequencies in patients with nasopharyngeal carcinoma (NPC) treated with helical tomotherapy (HT). MethodsFifteen patients with NPC who received HT treatment in Sun Yat-sen University Cancer Center from October 2019 to February 2020 were selected. Megavoltage computed tomography (MVCT) scanning was performed before each treatment. After five times of radiotherapy, system-error correction was performed to adjust the setup center. The setup errors before and after the correction of systematic errors, as well as the setup errors of different scanning ranges and different scanning frequencies, were collected for analysis and comparison. ResultsWhen comparing the setup errors before and after the correction of systematic error, the differences in setup errors in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions were statistically significant (P<0.05).The different scanning ranges of "nasopharynx + neck" and "nasopharynx" were compared, and a statistically significant difference was found in yaw rotational errors (P<0.05). In the comparison of daily and weekly scan frequency after system-error correction, a significant difference was found in AP direction (P<0.05). ConclusionDuring radiotherapy for NPC, the systematic error can be corrected according to the first five setup errors, and then small-scale scanning was selected for image-guided radiotherapy every day.

11.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 326-330, 2023.
Article in Chinese | WPRIM | ID: wpr-991747

ABSTRACT

Objective:To investigate the efficacy of radiofrequency ablation combined with ozone therapy under CT guidance in the treatment of lumbar disc herniation.Methods:A total of 93 patients with lumbar disc herniation who were admitted to The First Hospital of Jiaxing from January 2019 to May 2022 were included in this study. They were randomly divided into an observation group ( n = 47) and a control group ( n = 46). The control group was treated with radiofrequency ablation and the observation group was treated with radiofrequency ablation combined with ozone therapy. Efficacy was compared between the two groups at 3 months after surgery. The pain was compared between the two groups before and 7 days and 3 months after surgery. Inflammatory factors were compared between the two groups before and 7 days after surgery. The lumbar spine function was compared between the two groups before and 3 months after surgery. Results:At 3 months after surgery, the excellent and good rate in the observation group was significantly higher than that in the control group [89.36% (42/47) vs. 71.74% (33/47), χ2 = 4.63, P < 0.05). At 7 days and 3 months after surgery, Visual Analogue Scale scores in the observation group were (2.91 ± 0.54) points and (1.32 ± 0.31) points, respectively, which were significantly lower than (3.76 ± 0.62) points and (2.08 ± 0.47) points in the control group ( t = 7.06, 9.22, both P < 0.001). At 7 days after surgery, serum interleukin-1β, interleukin-6, and tumor necrosis factor-α in the observation group were (0.24 ± 0.05) μg/L, (18.49 ± 3.47) ng/L, and (97.94 ± 17.43) ng/L, respectively, which were significantly lower than (0.37 ± 0.09) μg/L, (24.31 ± 4.12) ng/L, and (148.87 ± 20.13) ng/L, respectively in the control group ( t = 8.63, 7.37, 13.05, all P < 0.05). At 3 months after surgery, the Japanese Orthopedic Association score in the observation group was significantly higher than that in the control group [(25.68 ± 2.28) points vs. (21.17 ± 3.24) points, t = -7.78, P < 0.001], and the Oswestry Disability Index in the observation group was significantly lower than that in the control group [(9.84 ± 1.43) points vs. (13.46 ± 2.18) points, t = 9.49, P < 0.001]. Conclusion:Radiofrequency ablation combined with ozone therapy under CT guidance is highly effective on lumbar disc herniation. The combined therapy can reduce pain and inflammatory reactions in patients and improve lumbar function.

12.
Cancer Research on Prevention and Treatment ; (12): 1097-1102, 2023.
Article in Chinese | WPRIM | ID: wpr-998957

ABSTRACT

Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT. Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement. Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (P=0.212). Conclusion The quantitative setup-error data can be obtained using linear accelerator on-board FBCT, and the non-isocenter IGRT induced set-up error cannot be negligible.

13.
Journal of Zhejiang University. Medical sciences ; (6): 162-168, 2023.
Article in English | WPRIM | ID: wpr-982031

ABSTRACT

Benign prostatic hyperplasia (BPH) is the most common cause of lower urinary tract symptoms in men. When drug treatment is ineffective or conventional surgery is not suitable, novel minimally invasive therapies can be considered. These include prostatic urethral lift, prostatic artery embolisation, water vapor thermal therapy, Aquablation-image guided robotic waterjet ablation, temporary implantable nitinol device and prostatic stents. These novel therapies can be performed in outpatient setting under local anesthesia, with shorter operative and recovery times, and better protection of ejaculatory function and erectile function. General conditions of the patient and advantages and disadvantages of the each of these therapies should be fully considered to make individualized plans.


Subject(s)
Male , Humans , Prostatic Hyperplasia/complications , Stents/adverse effects , Embolization, Therapeutic/adverse effects , Lower Urinary Tract Symptoms/surgery , Treatment Outcome , Minimally Invasive Surgical Procedures
14.
Article | IMSEAR | ID: sea-218415

ABSTRACT

Aims: Image-guided systems are the gold standard for determining toric intraocular lens (IOL) axis alignment. However, their high cost prevents widespread use of these systems. As an alternative, a simpler and affordable method could be performed manually using a slit-lamp biomicroscope. This study aims to compare the accuracy of manual toric IOL axis marking using a slit-lamp compared to the CALLISTO eye image-guided system.Study Design: Prospective comparativeMethods: In this prospective study, toric IOL axis alignment of 42 eyes with cataract and coexisting corneal astigmatism were evaluated using manual slitlamp method and CALLISTO eye image-guided method. Preoperative and postoperative uncorrected visual acuity, best corrected visual acuity, amount of spherical and astigmatic refractive errors, and postoperative IOL axis alignment were evaluated. Intraclass correlation of the manual method was calculated and the difference of IOL axis alignment to the image-guided method was compared.Results: Toric IOL implantation reduced the amount of astigmatic refractive error from -1.63 � 0.65 D to -0.50 � 0.19 D in the image-guided group and from -1.93 � -0.90 D to -0.87 � 0.26 D in the manual slitlamp group. As many as 90.5% of eyes in the image-guided group and 81.0% of eyes in the manual slitlamp group reached the target induced astigmatism (p=0.38). Manual axis marking showed intraclass correlation of 99.3%. However, when the manual method was compared to the image-guided method a mean difference in axis alignment of 10.98o (95% confidence interval: 9.32o - 12.63o) was observed.Conclusions: Alignment of toric IOL axis using the manual method demonstrated a consistent result; yet producing a considerable difference to the result of the image-guided method.

15.
Rev. bras. ginecol. obstet ; 44(1): 67-73, Jan. 2022. tab, graf
Article in English | LILACS | ID: biblio-1365666

ABSTRACT

Abstract Objective To evaluate the underestimation rate in breast surgical biopsy after the diagnosis of radial scar/complex sclerosing lesion through percutaneous biopsy. Data Sources A systematic review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations. The PubMed, SciELO, Cochrane, and Embase databases were consulted, with searches conducted through November 2020, using specific keywords (radial scar OR complex sclerosing lesion, breast cancer, anatomopathological percutaneous biopsy AND/OR surgical biopsy). Data collection Study selection was conducted by two researchers experienced in preparing systematic reviews. The eight selected articles were fully read, and a comparative analysis was performed. Study selection A total of 584 studies was extracted, 8 of which were selected. One of them included women who had undergone a percutaneous biopsy with a histological diagnosis of radial scar/complex sclerosing lesion and subsequently underwent surgical excision; the results were used to assess the underestimation rate of atypical and malignant lesions. Data synthesis The overall underestimation rate in the 8 studies ranged from 1.3 to 40% and the invasive lesion underestimation rate varied from 0 to 10.5%. Conclusion The histopathological diagnosis of a radial scar/complex sclerosing lesion on the breast is not definitive, and it may underestimate atypical andmalignant lesions, which require a different treatment, making surgical excision an important step in diagnostic evaluation.


Resumo Objetivo Avaliar o grau de discordância entre biópsia percutânea e cirúrgica da mama em pacientes com diagnóstico de cicatriz radiada/lesão esclerosante complexa (CR/LEC) por meio de uma revisão sistemática. Fontes dos dados Foi realizada uma revisão sistemática segundo as recomendações do Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA, na sigla em inglês). As bases de dados primárias consultadas foram PubMed, SciELO, Cochrane e Embase, combuscas conduzidas até novembro de 2020, utilizando palavras chaves específicas (cicatriz radiada OU lesão esclerosante complexa, câncer de mama, anatomopatológico de biópsia percutânea E/OU biópsia cirúrgica). Seleção dos estudos A busca dos artigos resultou em um total de 584 estudos, sendo 8 selecionados, os quais incluíam mulheres submetidas a biópsia com diagnóstico histológico de CR/LEC e posteriormente submetidas a exérese cirúrgica para avaliar como desfecho o grau de subestimação de lesões atípicas e malignas. Coleta de dados A seleção dos estudos foi conduzida por dois pesquisadores, com experiência na elaboração de revisão sistemática. Os oito artigos selecionados foram lidos na íntegra e submetidos a uma análise comparativa. Síntese dos dados Cicatrizes radiadas/lesões esclerosante complexas foram associadas com lesões atípicas e malignas após a exérese cirúrgica. O grau de subestimação geral foi calculado pela porcentagem de lesões atípicas e malignas no anatomopatológico após a exérese cirúrgica dentre o total de CR/LEC diagnosticadas, enquanto o grau de subestimação de lesões invasoras foi calculado considerando-se apenas os carcinomas invasivos. O grau de subestimação geral dos estudos selecionados variou de 1,3 a 40%, e o de lesões invasoras de 0 a 10,5%. Conclusão O diagnóstico histopatológico de CR/LEC na mama não é definitivo, podendo subestimar lesões atípicas e malignas, cujo tratamento é distinto, tornando a exérese cirúrgica etapa fundamental na investigação diagnóstica.


Subject(s)
Humans , Female , Breast Diseases/diagnosis , Breast Neoplasms/diagnostic imaging , Image-Guided Biopsy
16.
Chinese Journal of Hepatobiliary Surgery ; (12): 761-765, 2022.
Article in Chinese | WPRIM | ID: wpr-957040

ABSTRACT

Objective:To compare the safety and clinical value of percutaneous computed tomography (CT)-guided fine-needle aspiration biopsy (CT-FNA) with CT-guided core-needle biopsy (CT-CNB) in diagnosis of pancreatic lesions.Methods:We retrospectively analyzed the clinical data of patients with pancreatic lesions who underwent percutaneous CT-guided biopsy from January 2017 to January 2022 at the First Affiliated Hospital of Zhengzhou University. A total of 454 patients (251 men, 203 women) were enrolled in this study with age of (60.5±11.6) years old. They were divided into the CT-FNA group ( n=300) and the CT-CNB group ( n=154) according to the biopsy method. The one-time diagnosis rate, accuracy, sensitivity, false negative rate and incidence rate of complications of the two groups were compared. Results:The one-time diagnosis rate and accuracy rate in the CT-CNB group were slightly higher than those in the CT-FNA group, but the differences were not statistically significant [92.2%(142/154) vs. 86.0%(258/300), χ 2=3.74, P=0.053; 97.4%(150/154) vs. 92.0%(276/300), χ 2=0.16, P=0.690]. Compared with the CT-FNA group, the CT-CNB group had a higher sensitivity and a lower false negative rate, and the differences were statistically significant [97.2%(138/142) vs. 91.5%(260/284), χ 2=4.89, P=0.036; 2.8%(4/142) vs. 8.5%(24/284), χ 2=4.89, P=0.036]. Common complications in the two groups were pain, hematoma and pancreatitis, and there was no statistically significant difference in the incidences of complication [9.0%(27/300) vs. 9.1%(14/154), χ 2<0.01, P=0.975]. Conclusions:Both CT-FNA and CT-CNB were safe for diagnosis of pancreatic lesions, with high diagnostic yields and with similar safety and accuracy. When compared with CT-FNA, CT-CNB has a higher sensitivity and a lower false negative rate.

17.
International Eye Science ; (12): 875-879, 2022.
Article in Chinese | WPRIM | ID: wpr-923431

ABSTRACT

@#AIM:To compare the accuracy of Toric intraocular lens(IOL)alignment using the Verion image guided system and conventional manual marker. <p>METHODS:Prospective randomized controlled study. A total of 56 eyes of 47 age-related cataract patients who underwent phacoemulsification combined with Toric IOL implantation in our hospital from June 2016 to December 2019 were randomly divided into two groups:In the image-guided group, Verion navigation system collected anterior segmental images before surgery, and Toric target was set to 27 eyes in axial direction. In the marker group, Toric target was marked at 0° and 180° levels before surgery, and Toric target was marked in 29 eyes in axial direction according to the labeling ring. At 1h, 1wk, 1 and 3mo postoperatively, the anterior segment of patients with dilated pupil was photographed. Photoshop software was used to analyze the deviation between the actual axial direction and the target axial direction of the two groups, and the patients' naked eye visual acuity(UCDVA), best corrected visual acuity(BCDVA)and residual astigmatism were recorded. <p>RESULTS: At 1h and 3mo postoperatively, the deviation between the actual axis and the target axis of IOL in the navigation group was less than that in the marker group(1.5°±1.8° <i>vs</i> 3.1°±2.1°; 1.9°±1.6° <i>vs</i> 3.3°±2.4°, all <i>P</i><0.05). There was no difference in UCDVA(LogMAR)between the navigation group and the marker group(0.04±0.08 <i>vs</i> 0.06±0.07, <i>P</i>=0.338)and there was no difference in residual divergence(-0.39±0.32 <i>vs</i> -0.45±0.31D, <i>P</i>=0.491)between two groups at 3mo after operation.<p>CONCLUSION:Verion digital marking and manual marking showed high accuracy in marking Toric IOL axial direction. Although the navigation group showed no advantage in UCDVA and residual astigmatism, the IOL misalignment in navigation group was significantly smaller than the marker group, and Toric IOL axial direction was implanted more accurately under Verion digital marking.

18.
Chinese Journal of Radiation Oncology ; (6): 365-369, 2022.
Article in Chinese | WPRIM | ID: wpr-932677

ABSTRACT

Objective:To compare the comprehensive performance of three Varian on-board image (OBI) image systems (KV-CBCT, KV-planar and MV-EPID) and to explore the value of the combined application of these three systems in daily image-guided radiotherapy for nasopharyngeal cancer.Methods:KV-CBCT, KV-planar and MV-EPID scanning and registration were carried out in the left and right/abdominal and back/head and foot direction on human head and neck phantom. The set-up error, registration time, additional radiation dose and image quality of the three systems were compared by F-test.Results:KV-CBCT, kV-planar and MV-EPID were scanned for 55 times, respectively, and the set-up errors in the left and right/abdominal and back/head and foot direction of the three image-guided systems were (0.00±5.43)/(-0.02±5.49)/(0.02±5.58) mm, (0.04±5.49)/(0.02±5.56)/(0.02±5.54) mm, (0.02±5.22)/(0.11±5.34)/(-0.04±5.33) mm, respectively ( P=0.999, 1.000, 0.989). The average time consuming was (200±45) s, (120±36) s and (115±42) s; the additional radiation dose from low to high was kV-planar, KV-CBCT and MV-EPID; the image quality from low to high was MV-EPID, kV-planar and KV-CBCT. Conclusions:Three image-guided systems can meet the requirements of image-guided radiotherapy for nasopharyngeal cancer. Based on the overall performance of the three systems, 1 CBCT+ 4 kV planar per week is recommended and EPID should be used as a backup system in daily image-guided radiotherapy for nasopharyngeal cancer. This scheme makes full use of the high image quality of CBCT and the low radiation of kV planar to realize the regular detection of nasopharyngeal cancer volume change and the implementation of high-precision radiotherapy.

19.
Chinese Journal of Radiological Medicine and Protection ; (12): 269-276, 2022.
Article in Chinese | WPRIM | ID: wpr-932597

ABSTRACT

Objective:To analyze the effects of two decomposition algorithms of dual-energy cone beam CT (DECBCT) (direct decomposition and iterative decomposition) on the image quality and material decomposition accuracy of different sizes of phantoms.Methods:Different sizes of imaging parts of patients were simulated using the combination of CatPhan604 phantoms and customized annuluses. CBCT with high energy of 140 kVp and low energy of 100 kVp were acquired using the Varian Edge CBCT system. Then the material decomposition of DECBCT images was performed using the two algorithms. The electron density (ED) and contrast-to-noise ratio (CNR) of each material in the CTP682 module were calculated. They were used to assess the decomposition accuracy and image quality of the two algorithms.Results:Based on the values in the Catphan604 manual, both algorithms have high ED accuracy. Only the ED accuracy of four materials of the smallest sized phantom showed statistical difference ( z = -4.21, 4.30, 2.87, 5.45, P < 0.05), but the average relative error was less than 1%. The CNR of the iterative decomposition algorithm was significantly higher than that of the direct decomposition, increasing by 51.8%-703.47%. The increase in the phantom size significantly reduced the accuracy of ED, and the increased amplitude of the relative error was up to a maximum of 2.52%. The large phantom size also reduced the image quality of iterative decomposition, and the decreased amplitude of CNR was up to a maximum of 39.71. Conclusions:Compared with the direct decomposition, the iterative decomposition algorithm can significantly reduce the image noise and improve the contrast without losing the accuracy of electron density in the DECBCT construction of different sizes of phantoms.

20.
Acta ortop. bras ; 30(spe1): e248982, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383439

ABSTRACT

ABSTRACT Objective: To evaluate the effect of 3d printed models on surgical pre-operative planning of complex spinal deformities. Methods: In our study, five orthopedic surgeons made surgical planning of 5 patients with severe spinal deformity in three conditions: X-ray with computer tomography (X-ray-CT), 3D-computed tomography (3dCT), and 3d printed spine models. Operation plans were examined according to the level and number of instrumentations, osteotomy level, and time required for decision-making. Results: X-ray-CT, 3dCT, and 3d modeling methods were compared, and no statistically significant difference was observed in the number of screws and osteotomy score to be used in operation. The time required for decision ranking is 3d Model, 3d CT, and Xray-CT. Conclusions: 3d printed models do not influence the operative plan significantly; however, it reduces surgical planning time at pre-op duration, and those models gave some opportunities to practice with implants on a patient's 3d spine model. Level of Evidence III; Diagnostic Studies - Investigating a Diagnostic Test .


RESUMO Objetivo: Avaliar o efeito de modelos 3D impressos no planejamento pré-operatório cirúrgico de deformidades complexas da coluna vertebral. Métodos: Em nosso estudo, 5 cirurgiões ortopédicos fizeram o planejamento cirúrgico de 5 pacientes com deformidade espinhal grave em três condições: raio-X com tomografia computadorizada (raio X-CT), tomografia computadorizada com reconstrução 3D (3dCT) e modelo de coluna vertebral impressa (modelo 3d). Os planos de operação foram examinados de acordo com o nível e número de instrumentos, nível de osteotomia e tempo necessário para a tomada de decisão. Resultados: Foram comparados os métodos de modelagem de raio X-CT, 3dCT e modelo 3d e nenhuma diferença estatisticamente significativa foi observada no número de parafusos e escore de osteotomia a serem utilizados na operação. O ranking do tempo necessário para a tomada de decisão foi de modelo 3d, 3d CT e raio X-CT. Conclusões: Os modelos impressos em 3d não influenciam significativamente o plano operatório, porém reduzem o tempo de planejamento cirúrgico no pré-operatório e esses modelos deram algumas oportunidades de praticar com implantes no modelo de coluna 3d do paciente. Nível de evidência III; Estudos de Diagnóstico - Investigando um Teste de Diagnóstico .

SELECTION OF CITATIONS
SEARCH DETAIL