Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. bras. oftalmol ; 72(5): 307-311, set.-out. 2013. ilus, graf, tab
Article in English | LILACS | ID: lil-690700

ABSTRACT

PURPOSE: To determine linear regression models between Alpins descriptive indices and Thibos astigmatic power vectors (APV), assessing the validity and strength of such correlations. METHODS: This case series prospectively assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted among two phacoemulsification groups: one assigned to receive AcrySof®Toric intraocular lens (IOL) in both eyes and another assigned to have AcrySof Natural IOL associated with limbal relaxing incisions, also in both eyes. All patients were reevaluated postoperatively at 6 months, when refractive astigmatism analysis was performed using both Alpins and Thibos methods. The ratio between Thibos postoperative APV and preoperative APV (APVratio) and its linear regression to Alpins percentage of success of astigmatic surgery, percentage of astigmatism corrected and percentage of astigmatism reduction at the intended axis were assessed. RESULTS: Significant negative correlation between the ratio of post- and preoperative Thibos APVratio and Alpins percentage of success (%Success) was found (Spearman's ρ=-0.93); linear regression is given by the following equation: %Success = (-APVratio + 1.00)x100. CONCLUSION: The linear regression we found between APVratio and %Success permits a validated mathematical inference concerning the overall success of astigmatic surgery.


OBJETIVO: Estabelecer modelos de regressão linear entre os índices propostos por Alpins com os vetores astigmáticos de Thibos, avaliando a validade e a força dessas correlações. MÉTODOS: Série de casos na qual foram avaliados prospectivamente 62 olhos de 31 pacientes de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: um submetido a implante de lente intraocular (LIO) AcrySof ToricTM em ambos os olhos e outro grupo, no qual seriam implantadas LIO AcrySof NaturalTM complementada por incisões relaxantes limbares, também em ambos os olhos. Todos os pacientes foram reavaliados aos 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional tanto pelo método vetorial proposto por Alpins, quanto pelo proposto por Thibos. A razão entre os vetores astigmáticos pós e pré-operatórios de Thibos (VApós/pré), bem como a correlação linear com o percentual de sucesso da cirurgia do astigmatismo, o percentual de astigmatismo corrigido e o percentual de redução do astigmatismo no eixo pretendido, propostos por Alpins, foram avaliados. RESULTADOS: Foi encontrada correlação negativa significativa entre a VApós/pré de Thibos e o percentual de sucesso da cirurgia do astigmatismo (%Successo), de Alpins (ρ de Spearman=-0.93); regressão linear dada pela seguinte equação: %Successo = (-VApós/pré + 1,00)x100. CONCLUSÃO: A regressão linear encontrada entre VApós/pré e %Successo permite uma inferência matemática validada a respeito do sucesso de cirurgia do astigmatismo em termos gerais.


Subject(s)
Humans , Adult , Astigmatism , Diagnostic Techniques, Ophthalmological , Lens Implantation, Intraocular , Linear Models , Limbus Corneae/surgery , Phacoemulsification , Prospective Studies
2.
Rev. bras. oftalmol ; 70(5): 296-299, out. 2011. ilus
Article in English | LILACS | ID: lil-606739

ABSTRACT

This is a case report of a 45-year-old anisometropic woman with stage 2 keratoconus submitted to refractive lens exchange employing SN60T5 AcrySof Toric intraocluar lens on her left eye. Phacoemulsification followed by proper lens implantation was accomplished successfully. On postoperative period, favorable refractive and visual outcomes were obtained. The use of toric intraocular lenses may be an option in the refractive treatment of stage 2 keratoconus in selected cases.


Relatamos o caso de uma senhora de 45 anos de idade, portadora de ceratocone grau 2 e consequente anisometropia, submetida à extração do cristalino transparente, e uso da lente intraocular modelo SN60T5 AcrySof Toric para o olho esquerdo. Facoemulsificação seguida pelo implante da lente intraocular tórica no olho esquerdo. No pós-operatório, resultados refracionais e visuais satisfatórios foram alcançados. O uso de lentes intraoculares tóricas pode se constituir em opção terapêutica para casos selecionados de ceratocone grau 2.


Subject(s)
Humans , Female , Middle Aged , Phacoemulsification/methods , Lens Implantation, Intraocular , Keratoconus/surgery , Lens, Crystalline/surgery , Lenses, Intraocular , Refraction, Ocular , Visual Acuity , Anisometropia , Corneal Pachymetry , Keratoconus/diagnosis , Keratoconus/physiopathology
3.
Arq. bras. oftalmol ; 72(6): 755-759, Nov.-Dec. 2009. ilus
Article in English | LILACS | ID: lil-536766

ABSTRACT

PURPOSE: To compare the effect of an apodized diffractive intraocular lens (IOL) (Acrysof ReSTOR NaturalTM) and its yellow counterpart (Natural IQ TM) on frequency doubling technology (FDT) perimetry results. METHODS: This study included 37 eyes from 22 patients at the "Centro Oftalmológico Tranjan" who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM) performed by the same surgeon, at least three months prior to the study. Patients were subject to frequency doubling technology Matrix Perimeter testing. RESULTS: The patients were between 41 to 79 years old (mean, 70.78 ± 9.83) in the Natural IQ TM and 49 to 81 years old (mean, 67.11± 11.48) in the Acrysof ReSTOR NaturalTM group, and the mean IOP was 13.64 ± 2.02 mmHg in the Natural IQ TM 12.94 ± 1.39 mmHg in the Acrysof ReSTOR NaturalTM group. The mean pupillary diameter under scotopic conditions was 6.63 ± 1.16 mm in the Natural IQ TM group and 7.20 ± 1.8 mm in the Acrysof ReSTOR NaturalTM group (p=0.20). The mean deviation was -1.83 ± 3.46 dB in the Natural IQ TM group and -1.77 ± 3.94 dB in the Acrysof ReSTOR NaturalTM group (p=0.28). The pattern standard deviation was 3.49 ± 0.79 dB in the Natural IQ TM group and 3.20 ± 0.86 dB in the Acrysof ReSTOR NaturalTM group (p=0.27). CONCLUSION: There was no difference in the results of FDT Matrix perimetry in eyes that received apodized diffractive IOLs implant or eyes that received monofocal intraocular lens implant.


OBJETIVO: Comparar o efeito da lente difrativa apodizada (Acrysof ReSTOR NaturalTM) e da lente de mesma plataforma amarela (Natural IQ TM) sobre os resultados da perimetria de dupla frequência (FDT). MÉTODOS: O estudo incluiu 37 olhos de 22 pacientes do Centro Oftalmológico Tranjan que foram submetidos a cirurgia de facoemulsificação e implante de lentes intraoculares (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM) sem complicações, realizadas pelo mesmo cirurgião, pelo menos três meses antes do estudo. Pacientes foram submetidos à perimetria FDT Matrix. RESULTADOS: A idade dos pacientes variou de 41 a 79 anos (média, 70,78 ± 9,83) no grupo Natural IQ TM e 49 a 81 anos (média, 67,11± 11,48) no grupo Acrysof ReSTOR NaturalTM , a PIO média foi 13,64 ± 2,02 mmHg no grupo Natural IQ TM e 12,94 ± 1,39 mmHg no grupo Acrysof ReSTOR NaturalTM. O diâmetro pupilar sobre condições escotópicas foi 6,63 ± 1,16 mm no grupo Natural IQ TM e 7,20 ± 1,8 mm no grupo Acrysof ReSTOR NaturalTM (p=0,20). O MD foi de -1,83 ± 3,46 dB no grupo Natural IQ TM e -1,77 ± 3,94 dB no grupo Acrysof ReSTOR NaturalTM (p=0,28). O PSD foi de 3,49 ± 0,79 dB no grupo Natural IQ TM e 3,20 ± 0,86 dB no grupo Acrysof ReSTOR NaturalTM (p=0,27). CONCLUSÃO: Não houve diferenças nos resultados da perimetria com FDT Matrix em olhos que receberam implante de lentes intraoculares difrativas apodizadas ou olhos que receberam LIOs monofocais.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Lens Implantation, Intraocular , Lenses, Intraocular/adverse effects , Phacoemulsification , Visual Field Tests , Visual Fields/physiology , Contrast Sensitivity/physiology , Pupil/physiology , Treatment Outcome
4.
Arq. bras. oftalmol ; 69(6): 875-880, nov.-dez. 2006. graf
Article in Portuguese | LILACS | ID: lil-440427

ABSTRACT

OBJETIVO: Comparar os achados clínicos ecobiométricos das medidas dos métodos de imersão e contato. MÉTODOS: O comprimento axial foi medido em 120 ecobiometrias por onda "A" em 60 pacientes com catarata, usando o método de imersão (não-contato) e de contato, em amostra pareada. RESULTADOS: A média do comprimento axial encontrada foi de 23,19 mm (DP 1,32) com o método de imersão e 22,93 mm (DP 1,32) com o método de contato, usando a mesma sonda ultra-sônica. A diferença de 0,255 mm (DP 0,3) foi estatisticamente significativa para o nível de 0,01. A diferença deve ser levada em conta quando se estima precisão no cálculo de lente intra-ocular. A média do desvio padrão entre as repetidas medidas no mesmo olho foi de 0,04 com o método de imersão e 0,19 com o método de contato. A diferença de 0,15 foi estatisticamente significativa para o nível de 0,01. A diferença deve ser levada em conta quando se estima precisão na reprodutibilidade da técnica de exame. CONCLUSÃO: Esses dados fornecem parâmetros que podem ser usados para monitorar a prática clínica e para realizar outros estudos.


PURPOSE: To compare clinical biometric findings between measurements of immersion technique and contact technique. METHODS: Axial length was measured by A-scan in 120 medical examinations in 60 patients with cataract using a non-contact (immersion) and a contact technique in paired-samples by ultrasound. RESULTS: The mean axial length was found to be 23.19 mm (SD 1.32) with the immersion technique and 22.93 mm (SD 1.32) with the contact technique, using the same transducer probe. The difference of 0.255 mm (SD 0.3) was significant at the 0.01 level. The difference should be taken into account when evaluating the accuracy of IOL calculation. The mean standard deviation between recurrent measures in same eye was found to be 0.04 with the immersion technique and 0.19 with the contact technique. The difference of 0.15 was significant at the 0.01 level. The difference should be taken into account when evaluating the accuracy of reproductivity of technique examination. CONCLUSION: These data provide benchmark information that can be used to monitor clinical practice and to perform others studies.


Subject(s)
Humans , Biometry/methods , Cataract , Eye/anatomy & histology , Eye , Epidemiologic Methods , Preoperative Care , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL