Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 73(4): 771-780, Jul.-Aug. 2021. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1285281

ABSTRACT

The objective of this study was to evaluate follicular growth and ovulatory rates in mares treated with an intravaginal progesterone device (P4) during the 10-day period, associated with the use of estradiol benzoate (EB). The results were compared during the transition period (ET) in the spring and the breeding season in the summer (ER). The variables were submitted to ANOVA (Tukey's test), considering P<0.05. No ovulation occurred during the permanence of the P4 implant in both experimental periods. The ovulatory rate in the ER was 100% (n = 8) and in the ET 62.5% (n = 5; P = 0.0547). Significant differences were observed (<0.001), in both periods, comparing follicular growth rates during the permanence of P4 device (ER: 1.33 ± 0.89mm/d; ET: 1.00 ± 0.81mm/d) to the period without P4 (ER: 3.63 ± 1.33 mm/d; ET: 3.31 ± 1.66 mm/d). The present study demonstrated applicability and efficiency of a hormonal protocol using P4 intravaginal device and EB for follicular control in mares, both during ET and ER.


O objetivo deste trabalho foi avaliar a taxa de crescimento folicular e a taxa ovulatória em éguas tratadas com dispositivo intravaginal de progesterona (P4) durante o período de 10 dias, associado à utilização de benzoato de estradiol (BE). Os resultados foram comparados durante o período de transição (ET) da primavera com a época de reprodução no verão (ER). As variáveis foram submetidas à ANOVA (teste de Tukey), considerando-se P<0,05. Nenhuma ovulação ocorreu durante a permanência do dispositivo de P4 em ambos os períodos experimentais. A taxa ovulatória na ER foi de 100% (n = 8) e na ET, de 62,5% (n=5; P=0,0547). Diferença significativas (<0,001) foram observadas, em ambos os períodos experimentais, comparando as taxas de crescimento folicular durante a permanência da P4 (ER: 1,33 ± 0,89mm/d; ET: 1,00 ± 0,81mm/d) com o período sem P4 (ER: 3,63 ± 1,33mm/d; ET: 3,31 ± 1,66mm/d). O presente estudo demonstrou aplicabilidade e eficiência do protocolo hormonal utilizando dispositivo intravaginal de P4 e BE para controle folicular de éguas, tanto na ET quanto na ER.


Subject(s)
Animals , Female , Progesterone/administration & dosage , Benzoates , Estradiol , Horses/physiology , Ovulation , Seasons , Administration, Intravaginal , Analysis of Variance , Ovarian Follicle/physiology
2.
Arq. ciênc. vet. zool. UNIPAR ; 13(2): 99-104, jul.-dez. 2010. tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-621386

ABSTRACT

Para se avaliar a dinâmica ovariana, concentração de progesterona e taxa de gestação, 74 vacas Nelore foram inseridas ao acaso em dois Grupos para sincronização de estro. No GI (37 animais) utilizou-se para sincronização do estro, uma esponja artesanal impregnada com 200 mg de medoxiprogesterona e oxitetraciclina (ESTRO FORTE) e no GII, um implante de progesterona comercial (CIDR®). No dia do implante (D0) administrou-se benzoato de estradiol intramuscular (IM) (2mg - Estrogin®), na retirada (D7) administrou-se 300 µg de análogo de prostaglandina IM (Veteglan®), no D8 administrou-se IM indutor da ovulação (1000 UI hCG - Vetecor®) e no D9 realizou-se a inseminação artificial em tempo fixo (IATF), com sêmen de touro de eficiência e qualidade comprovada. Escolheram-se ao acaso 15 animais, para dosagem de progesterona sérica, nos dias: implante (D0), retirada (D7), D9, D17, D22, D25 e D30, e para avaliação transretal ultrassonográfica ovariana, a fim de se determinar o número e diâmetro do maior folículo em cada ovário. O diagnóstico de gestação foi realizado 35 dias da IATF e confirmado 25 dias após. O diâmetro médio diário do maior folículo foi semelhante entre os grupos e ovários (p>0,05), e também se observou efeito de interação entre o dispositivo de preparação artesanal (ESTRO FORTE) e o ovário esquerdo, que apresentou maior diâmetro folicular médio total. A concentração média de progesterona e a taxa de gestação de 27,03% (10/37) e 32,43% (12/37), foram semelhantes entre os grupos I e II, respectivamente. Concluiu-se que a sincronização de estro em vacas Nelore utilizando-se esponja intravaginal de progesterona de preparação artesanal (ESTRO FORTE) e comercial (CIDR®) apresenta desempenho semelhante em relação a dinâmica ovariana, ao perfil de progesterona e a taxa de gestação.


In order to evaluate the ovarian dynamics, concentration of progesterone and pregnancy rate, 74 Nelore cows were randomly subjected to two protocols of synchronization of estrus using in the Group I a device intravaginal of craft progesterone (ESTRO FORTE) and in the Group II, a commercial (CIDR®). It was chosen at random 15 animals, for determination of serum progesterone, on the day of implantation (D0), in the withdrawal (D7), on day nine, 17, 22, 25 and 30, and for evaluation to transrectal ovarian ultrasonography, to determination of the number and diameter of the largest follicle in each ovary. The diagnosis of pregnancy was performed 35 days after the FTAI and confirmed 25 days after. The daily average diameter of the largest follicle was similar between groups and ovaries (p> 0.05), and also revealed an interaction effect between the device of craft preparing (ESTRO FORTE) and the left ovary, that had showed higher medium total follicular diameter. The average concentration of progesterone and the pregnancy rate, 27.03% (10/37) e 32.43% (12/37), were similar between experimental groups. It was concluded that the synchronization of estrus in Nellore cows using a progesterone intravaginal device of craft preparing (ESTRO FORTE) and commercial (CIDR®) shows similar performance in relation to ovarian dynamics, to profile of progesterone and to pregnancy rate.


Para evaluar la dinámica de ovario, concentración de progesterona y índice de preñez, 74 vacas Nelore fueron inseridas al ocaso en dos grupos para sincronización de estro. En el GI (37 animales) se utilizó para sincronización de estro, una esponja artesanal impregnada con 200 mg de medoxiprogesterona y oxitetraciclina (ESTRO FUERTE) y en el GII, un implante de progesterona comercial (CIDR®). En el día del implante (D0) se administró benzoato de estradiol intramuscular (IM) (2mg - Estrogin®), en la retirada (D7) se administró 300 µg de análogo de prostaglandina IM (Veteglan®), en el D8 se administró inductor de ovulación (1000 UI hCG - Vetecor®) y en el D9 se realizó la inseminación artificial en tiempo fijo (IATF), con semen de toro de eficiencia y calidad comprobada. Eligieron al ocaso 15 animales, para dosificación de progesterona sérica, en los días: implante (D0), retirada (D7), (D9), D17, D22, D25 y D30, y para evaluación transrectal ultrasonográfica de ovario, para determinar el número y diámetro del mayor folículo en cada ovario. El diagnóstico de preñez se realizó 35 días de IATF y se confirmó 25 días después. El diámetro medio diario del mayor folículo fue semejante entre los grupos y ovarios (p>0,05), y también se pudo observar efecto de interacción entre el dispositivo de preparación artesanal (ESTRO FUERTE) y el ovario izquierdo, que presentó mayor diámetro folicular medio total. La concentración media de progesterona y el índice de preñez de 27,03% (10/37) y 32,43% (12/37), fueron semejantes entre los grupos I y II, respectivamente. Se concluyó que la sincronización de estro en vacas Nelore utilizando esponja intravaginal de progesterona de preparación artesanal (ESTRO FUERTE) y comercial (CIDR®) presenta desempeño semejante en relación a la dinámica de ovario, al perfil de progesterona y el índice de preñez.

SELECTION OF CITATIONS
SEARCH DETAIL