Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Braz. j. pharm. sci ; 52(1): 87-94, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-789079

ABSTRACT

ABSTRACT The present work describes the development of a new high performance liquid chromatographic (HPLC) method for the determination of Cefixime trihydrate under different stress conditons as specified by ICH. For the analysis, a Phenomenex (250 x 4.6 mm, 5 µm particle size) ODS column and a SPD 20 A UV detector at 289 nm was used. The selected mobile phase was 10 mM disodium hydrogen phosphate (with 0.5% TEA, pH adjusted to 6.3 with OPA) and methanol in the ratio of 75:25 (v/v) in isocratic mode at a flow rate of 1 mL.min-1.The linear regression analysis data for the calibration plots showed good linear relationship with r2 = 0.9997 in the concentration range of 5-100 μg.mL-1. The stress degradation was performed using acid, alkali, water, hydrogen peroxide and uv light.


RESUMO O presente trabalho descreve o desenvolvimento de um novo alta performance cromatografia líquida (HPLC) método para a determinação de cefixima tri-estresse sob diferentes condições, conforme especificado pelo ICH. Para a análise, a Phenomenex (250 x 4,6 mm, 5 µm de granulometria) ODS coluna e a SPD 20 um detector de UV em 289 nm foi utilizado. A fase móvel selecionado foi de 10 mM hidrogenofosfato dissódico (com 0,5% TEA, o pH ajustado para 6,3 com OPA) e de metanol em razão de 75:25 (v/v) no modo isocrático com uma taxa de fluxo de 1 mL.min-1. A análise de regressão linear para dados da calibração parcelas apresentaram boa relação linear com r2 = 0,9997 no intervalo de concentração de cerca de 5 100 µg.mL-1. Degradação do estresse foi realizado utilizando um ácido, alcalino, a água, o peróxido de hidrogênio e luz uv.


Subject(s)
Chromatography, High Pressure Liquid/methods , Cefixime/analysis , Metabolism , /methods , Microscopy, Ultraviolet/methods
2.
Braz. j. pharm. sci ; 51(2): 349-360, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755049

ABSTRACT

Three methods are proposed for the quantitative determination of raloxifene hydrochloride in pharmaceutical dosage form: ultraviolet method (UV) high performance liquid chromatography (HPLC) and micellar capillary electrophoresis (MEKC). These methods were developed and validated and showed good linearity, precision and accuracy. Also they demonstrated to be specific and robust. The HPLC and MEKC methods were tested in regards to be stability indicating methods and they showed to have this attribute. The UV method used methanol as solvent and optimal wavelength at 284 nm, obeying Lambert-Beer law in these conditions. The chromatographic conditions for the HPLC method included: NST column C18 (250 x 4.6 mm x 5 µm), mobile phase water:acetonitrile:triethylamine (67:33:0,3 v/v), pH 3.5, flow rate 1.0 mL min-1, injection volume 20.0 µl, UV detection 287 nm and analysis temperature 30 °C. The MEKC method was performed on a fused-silica capillary (40 cm effective length x 50 µm i.d.) using as background electrolyte 35.0 mmol L-1 borate buffer and 50.0 mmol L-1 anionic detergent sodium dodecyl sulfate (SDS) at pH 8.8. The capillary temperature was 32°C, applied voltage 25 kV, UV detection at 280 nm and injection was perfomed at 45 mBar for 4 s, hydrodimanic mode. In this MEKC method, potassium diclofenac (200.0 µg mL-1) was used as internal standard. All these methods were statistically analyzed and demonstrated to be equivalent for quantitative analysis of RLX in tablets and were successfully applied for the determination of the drug...


Três métodos são propostos para a quantificação de cloridrato de raloxifeno em sua forma farmacêutica de comprimidos: espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (HPLC) e eletroforese capilar micelar (MEKC). Estes métodos desenvolvidos e validados demonstraram linearidade, precisão e exatidão. Também foram específicos e robustos. Os métodos HPLC e MEKC foram desenvolvidos para indicar a estabilidade do fármaco e demonstraram ter este atributo. O método UV usou metanol como solvente e comprimento de onda de 284nm, obedecendo a Lei de Lambert-Beer nestas condições. Os parâmetros cromatográficos para o método HPLC foram: coluna NST C18 (250 x 4,6 mm x 5 µm), fase móvel composta de água:acetonitrila:trietilamina (67:33:0,3 v/v), pH 3,5, vazão da fase móvel de 1,0 mL min-1, volume de injeção de 20 µl, detecção no comprimento de onda de 287 nm e temperatura de análise de 30°C. O método MEKC foi realizado utilizando capilar de sílica fundida (40 cm de comprimento efetivo x 50 µm de diâmetro interno) usando como fase móvel solução tampão borato 35.0 mmol L-1 e solução de dodecil sulfato de sódio (SDS) 50.0 mmol L-1 pH 8,8. A temperatura de análise foi de 32 °C, com voltagem aplicada de 25 kV, detecção no comprimento de onda de 280 nm e injeção da amostra realizada a 45 mBar por 4 s em modo hidrodinâmico. Para este método MEKC, foi utilizado diclofenaco de potássio (200.0 µg mL-1) como padrão interno. Todos os métodos foram analisados estatisticamente e demostraram ser equivalentes para a análise quantitativa de raloxifeno em comprimidos e foram aplicados com sucesso na determinação do fármaco...


Subject(s)
Humans , Raloxifene Hydrochloride/analysis , Raloxifene Hydrochloride/pharmacology , Drug Compounding/methods , Drug Stability , Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary/methods , Spectrum Analysis/methods
3.
Braz. j. pharm. sci ; 49(2): 359-366, Apr.-June 2013. ilus, graf, tab
Article in English | LILACS | ID: lil-680647

ABSTRACT

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


Rivaroxabana, fármaco anticoagulante, atua em um ponto crucial no processo de coagulação do sangue e impede a formação de coágulos sanguíneos. Neste estudo, desenvolveu-se método de RP-HPLC para a determinação de rivaroxabana em comprimidos (Xarelto ® (10 mg)). Utilizou-se coluna LC (250 x 4,6 mm) Phenomenex Luna C18 5 mm 100 Å a 40 ºC. Realizou-se eluição isocrática com ACN: água (55:45 v/v). O fluxo foi de 1,2 mL min-1 e a detecção de UV foi a 249 nm. Padrão interno (cafeína) e rivaroxabana eluíram em 2,21 e 3,37 minutos, respectivamente. O método desenvolvido foi validado de acordo com as diretrizes do ICH e mostrou-se linear na faixa 0,005-40,0 mg mL-1. O método foi exato, preciso, robusto e rápido. Assim, foi aplicado com êxito para o ensaio de controle de qualidade da Rivaroxabana na forma de comprimidos.


Subject(s)
Chromatography, High Pressure Liquid/methods , Validation Study , Dosage Forms/standards , Indicators (Statistics) , Rivaroxaban/pharmacokinetics
4.
Braz. j. pharm. sci ; 49(3): 475-490, July-Sept. 2013. ilus, tab
Article in English | LILACS | ID: lil-689901

ABSTRACT

A novel, simple, accurate and precise RP-HPLC method for simultaneous determination of levosalbutamol sulfate and theophylline has been developed and validated. Separation was achieved on a Phenomenex; C18 column (250 mm × 4.6 mm i.d., 5 µm) using methanol: 10 mM TBAHS(tetrabutyl ammonium hydrogen sulfate) (50:50, v/v) as mobile phase at flow rate of 1.0 mL.min-1. The UV detection wavelength was 274 nm. The linearity is obeyed over a concentration range of 0.5-150 µg.mL-1 with correlation coefficient of 0.999 for both the drugs. The proposed method was validated by determining accuracy, precision, stability and system suitability parameters. The method was found to be robust. Specificity of the method was determined by subjecting the drugs to various stress conditions like acid, alkali, oxidation, thermal and photolytic degradation. The method was used successfully for the simultaneous determination of levosalbutamol sulfate and theophylline in syrup dosage form.


Desenvolveu-se e validou-se método de RP-HPLC novo, simples, exato e preciso de determinação simultânea do sulfato de levossalbutamol e teofilina.. A separação foi efetuada em uma coluna Phenomenex; C18 (250 mm x 4,6 mm d.i., 5 µm) utilizando metanol: TBAHS (hidrogenossulfato de tetrabutilamônio) 10 mM (50:50, v/v) como fase móvel, com fluxo de 1,0 mL.min-1. O comprimento de onda de detecção no UV foi 274 nm. Observou-se linearidade na faixa de concentração de 0,5-150 µg mL-1, com coeficiente de correlação de 0,999 para ambos os fármacos. O método proposto foi validado determinando-se exatidão, precisão, estabilidade e parâmetros de adequação do sistema. O método mostrou-se robusto. A especificidade do método foi determinada submetendo os fármacos a várias condições de estresse, como ácido, álcali, oxidação, degradação térmica e fotolítica. O método foi usado com sucesso para a determinação simultânea do sulfato de levossalbutamol e teofilina na forma de xarope.


Subject(s)
Theophylline/analysis , Chromatography, High Pressure Liquid/methods , Levalbuterol/analysis , Dosage Forms
5.
São Paulo; s.n; 2012. 156 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-691541

ABSTRACT

O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de...


Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than...


Subject(s)
Diabetes Mellitus , Drug Stability , Chemistry, Pharmaceutical/methods , Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary/methods
SELECTION OF CITATIONS
SEARCH DETAIL