Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 72(4): 1241-1247, July-Aug. 2020. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1131504

ABSTRACT

The aim of this study was to test the accuracy of a new automated computer software tool for the assessment of passive hip laxity. The hip laxity was estimated using the dedicated computer software by two blinded evaluators, one previously trained and one without specific training for distraction index measurement, in two independent sessions using 230 hip joints from 115 dogs that underwent screening for passive hip laxity using the distraction view. Previously, all of these radiographs were sent to PennHIP Analysis Center for an official distraction index record. The measurement repeatability of the two sessions was adequate for both evaluators. The reproducibility of the official distraction index measurement, mean distraction index±standard deviation 0.44±0.15, was adequate (P>0.05) for the trained evaluator, 0.44±0.15, and non-adequate (P<0.05), for the non-trained evaluator 0.47±0.17. The distraction index measurement tool proposed can be used with confidence for hip laxity evaluation by trained evaluators, as it provided good repeatability and reproducibility of official reports. The simplicity of the process described leads to a less time-consuming and more affordable procedure.(AU)


O objetivo deste estudo foi testar a viabilidade de uma nova ferramenta de software informático para avaliação da lassitude articular passiva da articulação coxofemoral. A lassitude articular da articulação coxofemoral foi estimada usando-se um programa informático especial, desenvolvido para o efeito, por dois avaliadores, um com treino prévio e outro não treinado, na medição do índice de distração, em duas sessões independentes, utilizando-se 230 articulações coxofemorais de 115 cães, as quais efetuaram o rastreio de displasia coxofemoral realizando a projeção de distração da articulação coxofemoral. Previamente, todas as radiografias foram enviadas para o PennHIP Analysis Center, para se obter uma medida oficial do índice de distração. A repetibilidade das medições das duas sessões foi adequada para ambos os avaliadores. A reprodutibilidade do índice de distração oficial, média±desvio-padrão 0,44±0,15, foi adequada (P>0,05) para o avaliador treinado, 0,44±0,15, e não adequada (P>0,05) para o avaliador não treinado, 0,47±0,17. A ferramenta de medição do índice de distração proposta pode ser usada com segurança na medição do índice de distração por avaliadores treinados, uma vez que mostra uma adequada repetibilidade e reprodutibilidade das medições oficiais do índice de distração. A simplicidade do processo apresentado torna-o menos demorado e mais econômico.(AU)


Subject(s)
Animals , Dogs , Software , Osteoarthritis, Hip/veterinary , Hip Dysplasia, Canine/diagnosis , Hip Joint/anatomy & histology , Joints/anatomy & histology
2.
Arq. bras. med. vet. zootec ; 68(4): 894-900, jul.-ago. 2016. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: lil-792458

ABSTRACT

We evaluated 160 hip joint radiographs of 40 dogs of different large breeds (25 females and 15 males) from the metropolitan area of Belo Horizonte, Minas Gerais, Brazil. The radiographs of each dog were obtained at two different stages: stage 1 (mean 7.23 months) and stage 2 (mean 14.25). The conventional radiographic method (CRM) and the radiographic distraction method (RDM) were used, carried out in both stages. CRM measured the Norberg angle (NA), the angle of inclination (AI) and evaluated the presence of degenerative joint disease (DJD). The MRD was performed to establish the distraction index (DI). The aims were to evaluate the presence of the Morgan line and other signs of DJD and correlate them with the degree of canine hip dysplasia (CHD) and also check if the DI greater than 0.3 (first stage) was associated with the presence of ML (second stage). It was found that DI, AI and changes of femoral neck and the formation of osteophytes were associated with the presence of ML. It was observed that if the DI is greater than 0.3 at the first stage, the chance of a positive outcome of ML in the second stage increases by 7.2 times. Thus, 49 joints showed DI > 0.3 at the first stage, in which 31 (63.3 %) presented ML at the second stage. Of the 31 animals that showed DI ≤ 0.3 at first, six (19.4%) had LM at the second stage. There has been a significant association between the presence of ML and the degree of CHD. The more severe the CHD, the higher the percentage of positive ML results. Thus, among the 24 (60 %) animals that showed ML, 11 (45.83 %) were classified as severe dysplastics, 5 (20.83%) as moderate and 8 (33.33 %) as mild. None of the animals classified as normal or borderline presented ML. Among the 8 animals classified as mild dysplastics, 5 showed only ML as DJD.(AU)


Avaliaram-se 160 radiografias das articulações coxofemorais de 40 cães de diferentes raças de grande porte, provenientes de Belo Horizonte, Brasil. As radiografias de cada animal foram obtidas em dois momentos: um (média de 7,23 meses de idade) e dois (média de 14,25 meses). Utilizaram-se o método radiográfico convencional (MRC) e o método radiográfico em distração (MRD), ambos realizados nos dois momentos. No MRC, mensurou-se o ângulo de Norberg (AN), o ângulo de inclinação (AI) e avaliou-se a presença de doença articular degenerativa (DAD). O MRD foi realizado para se estabelecer o índice de distração (ID). Os objetivos foram avaliar a presença da linha Morgan (LM) e de outros sinais de DAD, correlacionando-os com o grau de displasia coxofemoral (DCF); além de se verificar se o ID maior que 0,3 (primeiro momento) possui associação com a presença de LM (segundo momento). Verificou-se que ID, AI e encurtamento e/ou espessamento do colo femoral e formação de osteófitos foram associados à presença da LM. Observou-se que, quando o ID era maior que 0,3 no primeiro momento, a chance de um resultado positivo da LM no segundo momento aumentava em 7,2 vezes. No primeiro momento, 49 articulações apresentaram ID > 0,3. Destas, 31 (63,3%) apresentaram LM no segundo momento. Dos 31 animais que apresentaram ID ≤ 0,3 no primeiro momento, seis (19,4%) desenvolveram LM no segundo momento. Houve associação significativa entre presença de LM com o grau de DCF, e quanto mais grave a DCF, maior foi o percentual de resultados positivos da LM. Dos 24 (60%) animais que apresentaram LM, 11 (45,83%) foram classificados como displásicos graves, cinco (20,83%) como médios e oito (33,33%) como leves. Nenhum dos animais considerados suspeitos ou normais apresentou LM. Dos oito animais classificados como displásicos leves, cinco apresentaram apenas LM como sinal de DAD.(AU)


Subject(s)
Animals , Male , Female , Dogs , Hip Dysplasia, Canine , Osteoarthritis/veterinary , Joint Instability/veterinary , Radiography/veterinary
3.
Arq. bras. med. vet. zootec ; 66(6): 1735-1741, 12/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-735773

ABSTRACT

O objetivo deste estudo foi comparar a eficiência dos métodos radiográficos convencional e em distração de cães da raça Pastor Alemão adultos. Foram utilizados 16 animais, sendo onze fêmeas e oito machos, com idade média de quatro anos e dez meses. Todos os cães participantes foram avaliados clinicamente para se detectar a presença de alterações relacionadas ao aparelho locomotor e/ou sistema nervoso que afetariam a locomoção normal do cão, excluindo-se as alterações clínicas decorrentes do quadro de displasia coxofemoral (DCF). Para avaliação radiográfica das articulações coxofemorais, foram realizadas duas técnicas de avaliação, o Método Radiográfico Convencional (MRC), adotado pela Fédération Cynologique Internationale, e o Método Radiográfico em Distração (MRD). Dos animais avaliados, 62,5% foram classificados com algum grau de DCF. A correlação entre o MRC e o MRD foi moderada e a utilização isolada do MRD, pouco eficaz, com sensibilidade de 75% e especificidade de 44%. Nas condições em que este experimento foi conduzido, pode-se concluir que o MRC é um exame eficaz no diagnóstico quando comparado ao MRD em cães da raça Pastor Alemão adultos...


The aim of this study was to compare the efficacy of conventional and distraction radiographic methods in adult German Shepherd dogs. Sixteen animals were tested, eleven females and eight males, with a mean age of 4.8 years. All dogs were clinically evaluated to detect locomotor and/or nervous system changes that could affect normal locomotion, but clinical hip dysplasia (HD) alterations were excluded. Two techniques were used for radiographic evaluation of hip joints, the Conventional Radiographic Method (CRM), adopted by Fédération Cynologique Internationale and the Distraction Radiographic Method (DRM). 62.5% of the evaluated animals were classified as having some degree of HD. The correlation between CRM and DRM was moderate. When DRM was used alone, it was considered an ineffective method, with 75% sensitivity and 44% specificity. From this study, it can be concluded that CRM is an effective diagnostic method for hip dysplasia when compared to DRM in adult German Shepherd dogs...


Subject(s)
Animals , Adult , Dogs , Hip Dysplasia, Canine , Radiography/methods , Radiography/veterinary , Locomotion , Motor Activity , Nervous System
SELECTION OF CITATIONS
SEARCH DETAIL