Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article | IMSEAR | ID: sea-214725

ABSTRACT

Labour analgesia improving the maternal and neonatal outcome is time proven. Primary objective was to compare the quality of analgesia using visual analogue scale and secondary objectives were to assess the progress of labour, incidence of instrument assisted delivery, total dose of drug used in each technique, neonatal outcome and the incidence of maternal side effects.METHODSA prospective interventional study was done in 40 willing Primigravida (20 in each group) with uncomplicated singleton term gestation admitted to labour room during the period of 1 year after obtaining ethical clearance. Sample size calculated was 25 using the formula 4pq/d2 with 80 % power. Statistical analysis was done by SPSS v16 software. Association was tested using chi square test for qualitative variables and quantitative variables was tested using independent sample t test. Statistical significance between the VAS scores was tested using Mann Whitney test.RESULTSDemographic variables, pain scores, motor block and neonatal outcome were comparable in both the groups. The total drug requirement (p-0.5) and duration of second stage (p-0.08) were less and incidence of hypotension (p - 0.29) and rescue dose requirement (p-0.6) was more in intermittent bolus group. Instrumental delivery was higher in continuous infusion group. All parturients developed urinary retention.CONCLUSIONSLow volume of 0.2% ropivacaine with 2 mcg/mL fentanyl was effective in alleviating labour pain. Both techniques were equally effective and can be recommended for labour analgesia.

2.
Pesqui. vet. bras ; 39(4): 271-277, Apr. 2019. tab, graf
Article in English | VETINDEX, LILACS | ID: biblio-1002810

ABSTRACT

Dissociative anesthesia results in stressful and long recovery periods in monkeys and use of injectable anesthetics in medical research has to be refined. Propofol has promoted more pleasure wake up from anesthesia. The objectives of this study were to investigate the use of intravenous anesthetic propofol, establishing the required infusion rate to maintain surgical anesthetic level and comparing it to tiletamine-zolazepam anesthesia in Sapajus apella. Eight healthy capuchin monkeys, premedicated with midazolam and meperidine, were anesthetized with propofol (PRO) or tiletamine-zolazepam (TZ) during 60 minutes. Propofol was infused continually and rate was titrated to effect and tiletamine-zolazepam was given at 5mg/kg IV bolus initially and repeated at 2.5mg/kg IV bolus as required. Cardiopulmonary parameters, arterial blood gases, cortisol, lactate and quality and times to recovery were determined. Recovery quality was superior in PRO. Ventral recumbency (PRO = 43.0±21.4 vs TZ = 219.3±139.7 min) and normal ambulation (PRO = 93±27.1 vs TZ = 493.7±47.8 min) were faster in PRO (p<0.05). Cardiopulmonary effects did not have marked differences between groups. Median for induction doses of propofol was 5.9mg/kg, varying from 4.7 to 6.7mg/kg, Mean infusion rate was 0.37±0.11mg/kg/min, varying during the one-hour period. In TZ, two animals required three and five extra doses. Compared to tiletamine-zolazepam, minor post-anesthetic adverse events should be expected with propofol anesthesia due to the faster and superior anesthetic recovery. (AU)


A anestesia dissociativa em primatas resulta em recuperação anestésica lenta e estressante, e, portanto, o uso de anestesia injetável em pesquisas médicas precisa ser refinado. Por outro lado, o propofol promove recuperação mais suave. Os objetivos desse estudo foram investigar o uso do anestésico intravenoso propofol, estabelecer a taxa de infusão contínua necessária para manter anestesia cirúrgica, e comparar tal técnica com a dissociativa tiletamina-zolazepam em Sapajus apella. Oito macacos-prego saudáveis foram pré-medicados com midazolam e meperidina, e posteriormente anestesiados com propofol (PRO) ou tiletamina-zolazepam (TZ) durante 60 minutos. O propofol foi administrado em infusão contínua, e a taxa foi titulada ao efeito, já a tiletamina-zolazepam foi administrada em 5mg/kg IV como bolus inicial, e repiques de 2,5mg/kg IV conforme necessário. Os parâmetros cardiopulmonares, hemogasometria arterial, cortisol, e lactato, além da qualidade e duração da recuperação anestésica foram determinados. A qualidade da recuperação anestésica foi superior em PRO. O tempo para atingir decúbito ventral (PRO = 43,0±21,4 vs TZ = 219,3±139,7 min) e ambulação normal (PRO = 93±27,1 vs TZ = 493,7±47,8 min) foram mais rápidos em PRO (p<0,05). As variáveis cardiopulmonares não diferiram entre os grupos. A mediana para dose de indução com propofol foi de 5,9mg/kg, variando de 4,7 a 6,7mg/kg. A taxa de infusão contínua média de propofol foi de 0,37±0,11mg/kg/min, variando ao longo dos 60 minutos. Em TZ, dois animais necessitaram de três e cinco repiques. Comparado à tiletamina-zolazepam, menos efeitos adversos pós-anestésicos devem ser esperados com o propofol, devido à recuperação mais suave e rápida.(AU)


Subject(s)
Animals , Male , Female , Anesthesia Recovery Period , Cebus/surgery , Anesthesia, Intravenous/methods , Anesthesia, Intravenous/veterinary , Tiletamine/administration & dosage , Zolazepam/administration & dosage , Propofol/administration & dosage
3.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3193-3196, 2018.
Article in Chinese | WPRIM | ID: wpr-733887

ABSTRACT

Objective To compare the efficacy of programmed intermittent epidural bolus and continuous epidural infusion of ropivacaine in labor analgesia.Methods From May 2014 to May 2017,170 patients,24 -32 years,for full-term primipara in the Maternal and Child Health Care Hospital of Quzhou were selected as study objects,and they were randomly divided into intermittent epidural injection group (T group) and continuous epidural pump group(C group) by computer random software,with 85 cases in each group.All patients were epidurally injected 2%lidocaine 3mL and 0.2% ropivacaine 2mL at the opening of the uterus,less than 3cm.T group was given programmed intermittent epidural bolus 0.1% ropivacaine 6mL/h.C group was given continuous epidural infusion 0.1%ropivacaine 6mL/h.The pain of maternal(NRS score) and motor block situation of maternal (Bromage score) were monitored.The number of PCEA,PCEA pressure times,the rate of instrumental delivery and APGAR score were also recorded.Results The number of Bromage score≥2 in C group was higher than that of T group at 4-10h after labor analgesia (3 cases vs.11 cases,3 cases vs.15 cases,4 cases vs.17 cases,4 cases vs.18 cases,6 cases vs. 19 cases,6 cases vs.21 cases,7 cases vs.22 cases;χ2=4.982,8.947,9.182,10.230,7.926,9.907,9.354,all P<0.05).There was no statistically significant difference in NRS score between the two groups (P>0.05).The number of PCEA,PCEA pressure times and the rate of instrumental delivery in T group were lower than those in C group [8 cases vs.18 cases,22 cases vs.41 cases,(3.5 ±1.5) times vs.(4.9 ±2.2) times;χ2=4.541,9.104;t=2.666,all P<0.05].There was no statistically significant difference in Apgar score between the two groups (P>0.05).Conclusion Compared with continuous epidural infusion,programmed intermittent bolus of ropivacaine for labor analgesia exerts good analgesic effect,it has minor effects on exercise function and can decrease the rate of instrumental delivery .

4.
Rev. bras. anestesiol ; 66(5): 439-444, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: lil-794803

ABSTRACT

Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83). We found a higher caesarean delivery rate in group A (56.7%; p = 0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.


Resumo Justificativa: Há evidências de que a administração de um bolus epidural intermitente programado (BEIP) comparada com a infusão epidural contínua (IEC) resulta em maior eficácia da analgesia e da satisfação materna, com redução das intervenções anestésicas. Métodos: Neste estudo, 166 mulheres com gravidezes viáveis foram incluídas. Após uma dose epidural de 10 mL de ropivacaína a 0,16% e adição de 10 µg de sufentanil, as parturientes foram aleatoriamente designadas para um dos três regimes: A - ropivacaína a 0,15% mais solução de sufentanil (0,2 µg/mL) como infusão peridural contínua (5 mL/h, imediatamente após o bolus inicial); B - ropivacaína a 0,1% mais sufentanil (0,2 µg/mL) como bolus epidural intermitente programado; C - solução idêntica à do Grupo A com bolus epidural intermitente programado. Os regimes BEIP foram programados como 10 mL por hora, começaram 60 minutos após o bolus inicial. Bolus de resgate de 5 mL da mesma solução foi administrado com bomba de infusão. A satisfação materna foi avaliada com uma escala numérica verbal de 0 a 10. Também avaliamos os resultados adversos maternais e neonatais. Resultados: Foram avaliadas 130 gestantes (A = 60, B = 33; C = 37). A mediana na escala numérica verbal para a satisfação materna foi de 8,8 no grupo A; 8,6 no grupo B e 8,6 no grupo C (p = 0,83). Encontramos uma taxa mais elevada para parto cesário no grupo A (56,7%; p = 0,02). Não observamos diferenças no bloqueio motor, taxa de parto instrumental e resultados neonatais. Conclusões: A manutenção da analgesia peridural com bolus epidural intermitente programado está associada a uma redução da incidência de parto cesariano com satisfação materna igualmente elevada e sem resultados adversos.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Adult , Analgesia, Epidural/methods , Analgesia, Obstetrical/methods , Infusion Pumps , Cesarean Section/statistics & numerical data , Double-Blind Method , Prospective Studies , Analgesia, Patient-Controlled , Patient Satisfaction , Endpoint Determination , Anesthetics, Local/administration & dosage
5.
Korean Journal of Anesthesiology ; : 603-608, 2008.
Article in Korean | WPRIM | ID: wpr-165084

ABSTRACT

BACKGROUND: Off-pump coronary artery bypass (OPCAB) patients often require fluid, vasopressor, or inotropic support.It is therefore important that vigilant monitoring be undertaken to guide intervention and monitor the effects of therapy.Continuous monitoring of cardiac output (CO) is advisable.The aim of this study was to compare continuous cardiac index (CCI) and stat cardiac index (SCI) with intermittent bolus cardiac index (ICI) in patients undergoing OPCAB surgery. METHODS: Matched sets of CI measurements among CCI, SCI, and ICI were collected in 35 patients undergoing elective OPCAB at specific time periods.Bland-Altman analysis was used to compare the agreement among the different methods. RESULTS: Bland-Altman analysis of CI measurements yielded a bias, precision, and percent error of 0.09 +/- 0.63 L/min/m(2) (46.2%) for CCI and 0.09 +/- 0.60 L/min/m(2) (44.0%) for SCI, compared with ICI measurements. CONCLUSIONS: We found that the agreement of CCI, SCI, and ICI was poor.This disagreement increased during periods of open thorax and open pericardium when compared to the period of closed thorax.Continuous CO measurements through pulmonary artery catheter should be interpreted with caution during OPCAB.


Subject(s)
Humans , Bias , Cardiac Output , Catheters , Coronary Artery Bypass, Off-Pump , Organothiophosphorus Compounds , Pericardium , Pulmonary Artery , Thoracic Surgery , Thorax
SELECTION OF CITATIONS
SEARCH DETAIL