1.
The Journal of Korean Academy of Prosthodontics ; : 251-257, 2017.
Article in English | WPRIM | ID: wpr-90430

ABSTRACT

PURPOSE: The purpose of this study was to evaluate whether the internal abutment length affected screw stability in an internal connection implant. MATERIALS AND METHODS: Twenty long internal connection implants (Replus system, 4.7 × 11.5 mm) were selected for this investigation. Abutments were assigned to four groups depending on the length of the internal connection (abutments with internal lengths of 1, 2, 3, and 4 mm, respectively). Each implant fixture specimen was embedded in resin medium and connected to an abutment with an abutment screw. A load of 100 N, applied at an angle of 30° to the long axis of the implant, was repeated for 1.0 × 10⁶ cycles. Reverse torque values (RTV) were recorded before and after loading, and the change in RTV was calculated. Data were analyzed with the Kruskal-Wallis test. RESULTS: The change in RTV was not significantly different among the groups (P>.05). Screw loosening and fractures were not observed in any groups, and joint stability was maintained. CONCLUSION: The internal length of the abutment may not significantly affect the degree of screw loosening.


Subject(s)
Joints , Torque
2.
The Journal of Korean Academy of Prosthodontics ; : 370-378, 2016.
Article in Korean | WPRIM | ID: wpr-169358

ABSTRACT

PURPOSE: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. MATERIALS AND METHODS: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. RESULTS: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutmentscrew interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). CONCLUSION: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.


Subject(s)
Computer-Aided Design , Joints , Seoul , Torque
3.
The Journal of Korean Academy of Prosthodontics ; : 93-102, 2016.
Article in Korean | WPRIM | ID: wpr-75242

ABSTRACT

PURPOSE: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. MATERIALS AND METHODS: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, α=0.05). RESULTS: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. CONCLUSION: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.


Subject(s)
Statistics as Topic , Titanium , Torque
4.
The Journal of Korean Academy of Prosthodontics ; : 119-127, 2012.
Article in Korean | WPRIM | ID: wpr-229220

ABSTRACT

PURPOSE: This study was performed to compare the stress distribution pattern of abutment-fixture connection area using 3-dimensional finite element model analysis when 5 different implant systems which have internal connection. MATERIALS AND METHODS: For the analysis, a finite element model of implant was designed to locate at first molar area. Stress distribution was observed when vertical load of 200 N was applied at several points on the occlusal surfaces of the implants, including center, points 1.5 mm, 3.0 mm away from center and oblique load of 200 N was applied 30degrees inclined to the implant axis. The finite element model was analyzed by using of 3G. Author (PlassoTech, California, USA). RESULTS: The DAS tech implant (internal step with no taper) showed more favorable stress distribution than other internally connected implants. AS compare to the situations when the loading was applied within the boundary of implants and an oblique loading was applied, it showed higher equivalent stress and equivalent elastic strain when the loading was applied beyond the boundary of implants. Regardless of loading condition, the abutments showed higher equivalent stress and equivalent elastic strain than the fixtures. CONCLUSION: When the occlusal contact is afforded, the distribution of stress varies depending on the design of connection area and the location of loading. More favorable stress distribution is expected when the contact load was applied within the diameter of fixtures and the DAS tech implant (internal step with no tapering) has more benefits than the other design of internally connected implants.


Subject(s)
4-Acetamido-4'-isothiocyanatostilbene-2,2'-disulfonic Acid , Axis, Cervical Vertebra , Bite Force , California , Dental Implants , Finite Element Analysis , Molar , Sprains and Strains
5.
The Journal of Korean Academy of Prosthodontics ; : 653-664, 2007.
Article in Korean | WPRIM | ID: wpr-179756

ABSTRACT

STATEMENT OF PROBLEM: The screw detorque value is a measure of the preload remaining in the screw just before detorquing. PURPOSE: This study evaluated the effect of different screw tightening sequences and tightening methods on detorque values for a well-fitting implant superstructure. MATERIAL AND METHOD: An implant superstructure that connected directly to four implants (Astra Tech) was fabricated on a fully edentulous mandibular acrylic resin model. Six wellfitting dental stone casts were made with a pickup impression of the superstructure from the acrylic resin model. To evaluate the effect of three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and two tightening methods (2-step and 1-step) on the stability of screw joint, the detorque values for a well-fitting implant superstructure were measured twice after screw tightening using 20 Ncm. Detorque values were analyzed using multi-way analysis of variance and two-way analysis of variance at a .05 level of significance. RESULTS: 1. The mean detorque values for three screw tightening sequences were 12.3 Ncm, 12.6 Ncm, and 12.0 Ncm, respectively. 2. The mean detorque values for two screw tightening methods were 12.0 Ncm, and 12.2 Ncm, respectively. 3. The mean of mimimum detorque values for three screw tightening sequences and for two tightening methods were 10.6 Ncm, 11.1 Ncm, 10.5 Ncm, and 9.8 Ncm, respectively. 4. No statistically significant differences among the variables of screw tightening sequence and tightening method were found (p>.05) for detorque values and for mimimum detorque values. CONCLUSION: Within the limitations of this study, the screw tightening sequence and tightening method did not have a significant effect on the detorque values for a well-fitting implant superstructure.


Subject(s)
Joints
6.
The Journal of Korean Academy of Prosthodontics ; : 338-351, 2005.
Article in English | WPRIM | ID: wpr-112953

ABSTRACT

STATEMENT OF PROBLEM: Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. PURPOSE: This study is to evaluate the machining accuracy and consistency of the implant fixture/abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) MATERIALS AND METHODS: The implant systems selected in this study were internal connection type implants from AVANA(Osstem(R)), Bioplant(Cowell-Medi(R)), Dio(DIO(R)), Neoplant(Neobiotech (R)), Implantium(Dentium(R))systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and CONCLUSIONS: 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.


Subject(s)
Korea , Osseointegration , Polyesters